• Title/Summary/Keyword: thermal link

Search Result 69, Processing Time 0.032 seconds

The Investigation on Thermal Aging Characteristics of Oil-Paper Insulation in Bushing

  • Liao, Rui-jin;Hu, En-de;Yang, Li-jun;Xu, Zuo-ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1114-1123
    • /
    • 2015
  • Bushing is the key link to connect outer and inner insulating systems and also the essential electric accessory in electric power system, especially in the high voltage engineering (AC 1000kV, DC 800kV). This paper presented the experimental research of thermal aging characteristic of oil-paper insulation used in bushing. A thermally accelerated aging experiment at 90℃ was performed. The bushing models containing five layers of paper were sealed into the aging vessels and further aged for 250 days. Then several important parameters associated with the aging were observed and evaluated. The results showed that the degree of polymerization (DP) of papers gradually decreased. The DP values of outermost layer and middle layer fit well into the second-order kinematic model and first-order kinematic model, respectively. Less deterioration speed of the inter-layer paper than outer layer was confirmed by the variation of DP. Hydrolysis was considered as the main cause to this phenomenon. In addition, the logarithm of the furfural concentrations in insulation oil was found to have good linear relationship with DP of papers. Interestingly, when the aging time is about 250 days and DP is 419, the aging process reaches an inflection point at which the DP approaches the leveling off degree of polymerization (LODP) value. Both tanδ and acid number of oils increased, while surface and volume resistivity of papers decreased. The obtained results demonstrated that thermal aging and moisture absorbed in papers brought great influence to the degradation of insulating paper, leading to rapid decrease of DP and increase of the tanδ. Thus, the bushing should be avoided from damp and real-time monitoring to the variation of tanδ and DP values of paper is an effective way to evaluate the insulation status of bushing.

Study on Mechanical and Thermal Properties of Tio2/Epoxy Resin Nanocomposites

  • Kim, Bu-Ahn;Moon, Chang-Kwon
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.2
    • /
    • pp.102-110
    • /
    • 2013
  • The purpose of this study was to improve the properties of epoxy resin using titanium oxide nanoparticles. The effects of particle weight fraction, dispersion agent, and curing agents with different molecular weights on the thermal and mechanical properties of titanium-oxide-reinforced epoxy resin were investigated. In addition, the effect of the particle dispersion condition on the mechanical properties of nanocomposites was studied. As a result, it was found that the glass transition temperature of film-shaped nanocomposites decreased with an in-crease in the nanoparticle content. Because nanoparticles interrupted the cross linkage between the epoxy resin and the amine curing agent, the cross-link density of the epoxy became lower and led to a decrease in $T_g$ in the nanocompo-sites. The tensile strength and modulus in film-shaped nanocomposites also increased with the particles content. But in the case of dog-bone-shaped nanocomposites, the values were not similar to the trend for the film-shaped nanocompo-sites. This was probably a result of the different nanoparticles dispersions in the epoxy resins resulting from the respective-thicknesses of the film and dog-bone-shaped samples.

Evaluation of the Closed-type Sprinkler Head Activation Time (밀폐형 스프링클러 헤드의 동작시간 평가)

  • Moon-Hak, Jee;Sung-Yull, Hong
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2004
  • As a predominant active fire suppression method, closed-type sprinkler systems are used for the purpose of fire control and suppression at the nuclear power plants as well as the industrial facilities. It goes without saying that the proper selection of the system guarantees the adequate actuation of the thermal device. Consequently, the appropriate evaluation should be executed for the thermal behavior with the theoretical and empirical approach. For this purpose, the comparison of activation time for the fusible-link type sprinkler head with the simplified fire case and t-square fire growth case was evaluated. At this paper, the comparison output was presented with the tendency of thermal behavior. In addition, we issued some technical comments for the most appropriate equation in case of the estimation of the sprinkler head activation time. We also raised some idea that should be incorporated for the usage of the t-square equation for the realistic application in the field of the performance-base fire protection approach.

CFD/RELAP5 coupling analysis of the ISP No. 43 boron dilution experiment

  • Ye, Linrong;Yu, Hao;Wang, Mingjun;Wang, Qianglong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.97-109
    • /
    • 2022
  • Multi-dimensional coupling analysis is a research hot spot in nuclear reactor thermal hydraulic study and both the full-scale system transient response and local key three-dimensional thermal hydraulic phenomenon could be obtained simultaneously, which can achieve the balance between efficiency and accuracy in the numerical simulation of nuclear reactor. A one-dimensional to three-dimensional (1D-3D) coupling platform for the nuclear reactor multi-dimensional analysis is developed by XJTU-NuTheL (Nuclear Thermal-hydraulic Laboratory at Xi'an Jiaotong University) based on the CFD code Fluent and system code RELAP5 through the Dynamic Link Library (DLL) technology and Fluent user-defined functions (UDF). In this paper, the International Standard Problem (ISP) No. 43 is selected as the benchmark and the rapid boron dilution transient in the nuclear reactor is studied with the coupling code. The code validation is conducted first and the numerical simulation results show good agreement with the experimental data. The three-dimensional flow and temperature fields in the downcomer are analyzed in detail during the transient scenarios. The strong reverse flow is observed beneath the inlet cold leg, causing the de-borated water slug to mainly diffuse in the circumferential direction. The deviations between the experimental data and the transients predicted by the coupling code are also discussed.

Fuel Cell as an Alternative Distributed Generation Source under Deregulated Power System (규제가 없는 전력계통에서 대체분산형전원으로서의 연료전지)

  • Lee, Kwang-Y.;Kim, Se-Ho;Kim, Eel-Whan;Kim, Ho-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.331-332
    • /
    • 2006
  • This paper proposes the fuel cell power plants as alternative energy sources for distributed generation in Jeju Island, Korea. This will help to increase the fuel efficiency, at least double the current thermal power plants, decrease environmental pollution, virtually to none, increase the reliability of power supply, reducing the dependency of the HVDC link, and provide quality power to the growing infrastructure in meeting the requirements for the free-trade international island.

  • PDF

Design of a cycler system for large capacity lithium-polymer battery (중대형 리튬폴리머 2차전지용 충방전기 개발)

  • Oh Dong-Seob;Oh Sung-Up;Lee Jong-Yun;Park Min-Ho;Seong Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.82-86
    • /
    • 2004
  • In this paper, a cycler system for the Lithium-Polymer battery with the large capacity of 120Ah is presented. This system is constituted as the two units for the charging and discharging. The Lithium-Polymer battery should be charged in CC and CV mode, and it is required a very high precision control of the voltage and current for the charging unit. To decrease the switching noises and harmonics, parallel operation method is adopted and utilized in the power conversion module. The discharging unit has a link AC system function to return the discharging energy of battery to AC line and has comparatively less thermal loss. These units are designed to be controlled and monitored by personal computer. The total system for the battery charging and discharging is described and presented.

  • PDF

The Study of the method of calculating Maximum voltage in Flux-Weakening Region (약계자 영역에서 최대전압 설정에 관한 연구)

  • 김장목;임익헌;류홍우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.26-30
    • /
    • 1999
  • The constraint condition is the stator voltage and the stator current to operate the motor in the flux weakening region. The maximum current is limited by the inverter current rating and the machine thermal rating. Given DC link voltage to control the motor in the flux weakening the maximum voltage is determined by considering PWM strategy, dead time, voltage drop of the inverter switching device, and the margin of the voltage for current forcing. In this paper, the new method to determine the available maximum voltage is derived by the analythic method and by considering the factors of the voltage drop. So Determining the maximum voltage is very useful to enlarge the speed operation region in the flux weakening operation, the utility of the maximum voltage is increased.

  • PDF

Recycling Natural Rubber Vulcanizates through Mechanochemical Devulcanization

  • Jang G. K.;Das C. K.
    • Macromolecular Research
    • /
    • v.13 no.1
    • /
    • pp.30-38
    • /
    • 2005
  • Sulfur-cured gum natural rubber vulcanizates were devulcanized using two different concentrations of diallyl disulfide. The devulcanization process was performed at $110^{\circ}C$ min in an open two-roll cracker-cum-mixing mill. Natural rubber vulcanizates having various sulfur/accelerator ratios were used to study the cleavage of monosulfide, disulfide, and polysulfide bonds. The properties of devulcanized natural rubber increased upon increasing the disulfide concentration and the mechanical properties of the revulcanized natural rubber increased upon decreasing the sulfur content in the original rubber vulcanizates. The scorch time and the maximum state of cure both increased when the ground vulcanizates were treated with higher amounts of disulfide. TGA and DMA were conducted to study the effects of the devulcanization on the thermal stability and the $T_g$ behavior of the vulcanizates. SEM analysis was conducted to study how the failure mechanism was affected by the devulcanization process. It was possible to recover $70-80\%$ of the original gum rubber properties by using this process. From IR spectroscopic analysis, we observed that the oxidation of the main chains did not occur during high-temperature milling.

FLIGHT SOFTWARE DEVELOPMENT FOR THE KODSAT

  • Choi Eun-Jung;Park Suk-June;Kang Suk-Joo;Seo Min-Suk;Chae Jang-Soo;Oh Tae-Sik
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.364-367
    • /
    • 2004
  • This paper presents the flight software of KoDSat (KSLV-l Demonstration Satellite) which performs demonstrating the KSLV-l (Korea Space Launch Vehicle-l)'s satellite launch capability. The KoDSat Flight Software executes in a single-processor, multi-function flight computer on the spacecraft, the OBC (On Board Computer). The flight software running on the single processor is responsible for all real-time processing associated with: processor startup and hardware initialization, task scheduling, RS422 handling function, command and data handling including uplink command and down-link telemetry, attitude determination and control, battery state of charge monitoring and control, thermal control processing.

  • PDF

The Effect Analysis for Rain Attenuation of VSAT

  • Tak, Hong-Sung;Wook, Shin-Gang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.65.4-65
    • /
    • 2001
  • In case of data transmission using the upper 10GHz frequency, rain results in attenuation of radio waves. And the most serious atmospheric effect in a satellite link is the rainfall. The attenuation of rainfall very seriously affects the quality of transmission line. Because the rain increases thermal noise and interference, and decreases the amplitude of the signal. KOWACO manages the VSAT system instead of VHF network for communication of rain and water-level data from 1998. The purpose of this system is to monitor the change of water-level and rain data during a flood duration. VHF system acquires the data by a call per a hour. But the satellite network obtains the data whenever event data occur. Thus the satellite network is more powerful than the VHF system. In study ...

  • PDF