• Title/Summary/Keyword: thermal insulation of clothing

Search Result 98, Processing Time 0.024 seconds

Development and Commercialization of Warm Covers Using Natural Fabric (천연 소재를 이용한 보온덮개 개발 및 사업화 방안)

  • Choi, Ju-Hyun;Beak, Hyun-Kuk;Cho, Yun-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.227-233
    • /
    • 2018
  • The purpose of this study was to develop a warm cover for greenhouse with excellent thermal insulation and to propose ways of commercialization of the product. Feathers were used as filling materials because they formed the air layer to enhance insulation. Instead of downs for clothing or other textile products, we used disposed feathers. The developed product covers the outside of the greenhouse to keep the crops warm. It has multiple layers including feathers as filling materials, padding, inside fabric, heat insulation materials and outer fabric. It has proven to improve the insulation ratio. We developed other kinds of warm covers that are applicable to the inside of the greenhouse or the small houses in the greenhouse. Also, R&D system of educational industrial complex enables us to commercialize the products and building marketing strategies for them. This technology contributes to the expansion of energy-saving facilities for farmers, and it can serve the development and spread of various products utilizing feather.

Actual Condition Survey for Thermal Functionality Improvement of Female Student's Winter Uniforms (여고생 동복의 보온기능성 개선을 위한 실태조사)

  • Kim, Yu Mi;Lee, Jeong Ran
    • Fashion & Textile Research Journal
    • /
    • v.16 no.6
    • /
    • pp.954-960
    • /
    • 2014
  • This study surveyed high school girls in the Busan, Ulsan, and Gyeongnam areas to study how they wear school uniforms along with their satisfaction levels and demands in regards to functional school uniforms. This study presents data on the requirements for the development of winter school uniforms for high school girls with improved warmth functions. The findings are: First, high school girls purchased school uniforms of different brands and the purchase rates for three brands were 25% to 30% approximately. Most of them spent more than 300,000 KRW and less than 400,000 KRW on school uniforms purchases. Second, the greatest complaints by students about winter school uniforms were the ability to conduct routine activities and poor thermal insulation. The most popular bottom underwear for girls was underpants and leggings. The most popular top underwear was half-sleeved round neck t-shirts and running shirts. Third, a survey about uniform functionality showed that most students used and 'arm pit sweat absorbing pad', 'Waist size adjusting function, and 'inside pockets with zippers'. Satisfaction with functional uniforms was low: less than 3.5 in all questions. Fourth, students were favorable to develop functional uniforms to keep warm in the winter. The bottom needs to be warmer than the top and it is necessary to keep legs warm, especially the thighs and calves.

Physiological Responses and Subjective Sensations by Clo Values at -10℃ (환경온도 -10℃에서 Clo값에 따른 인체 생리반응 및 주관적 감각)

  • Kim, Ji-Yeun;Song, Min-Kyu;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.12 no.4
    • /
    • pp.531-537
    • /
    • 2010
  • The purpose of this study was to review physiological responses and subjective sensations in the cold environment when the subjects wore ensemble with different clo values. Seven healthy male subjects participated in this experiment. This experiment was conducted in a climatic chamber with $-10^sC$ and 50%RH. Subjects wore five different kinds of ensemble[C1 (4.453 clo), C2 (3.452 clo), C3 (2.865 clo), C4 (2.387 clo), and C5 (2.280 clo)]. The experiment was composed of 20 min of rest period, 20min of treadmill exercise(6 km/h) period, 30 min of recovery period. We monitored skin temperature on 7 sites, clothing microclimate and subjective sensations. The clo value had positive correlations with mean skin temperature and clothing microclimate. The subjects feel more warm and humid as the clo value goes up. The subjects reported comfort when they wore C1 and C2 ensemble having over 3 clo value. However, they felt less comfortable during the exercise period since there was high humidity. Skin temperature on the extremities were more dramatically changed by the exercise rather than clo value. Thus it seems that in the cold environment, heat balance can mostly be controlled by the choice of clothing, and the clothes with high clo values can provide higher insulation. In conclusion, our findings suggest that it would be more effective to control clo value depending on the activity level for maintaining comfort level in the cold environment.

An application to HVAC control system based on occupants' thermal response in office buildings (공조제어 적용을 위한 재실자 온열반응 데이터의 유효성 분석에 관한 연구)

  • Han, Hyesim;Kim, Jonghun;Jeong, Hakgeun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.111-117
    • /
    • 2014
  • In South Korea, the government has recently enforced regulations associated with buildings. Temperature restriction in indoor environment is one of the common ways of energy reduction in order not to dissipate heating and cooling energy; however the people who are in restricted temperature feels uncomfortable. Furthermore, occupants cannot feel the same thermal sensation even they are in the same place. For the reason, occupants should express their thermal sensation and HVAC system should be able to apply their demand. It is proved by an adaptive principle. The adaptive model means that people react in ways which tend to restore their comfort, when change occurs such as to produce discomfort. In order to design HVAC control strategies based on adaptive model, we designated an existing office building as a reference building to gather data from actual field. Furthermore, we gathered occupants' thermal sensation and clothing insulation in real-time. We filtered the data with Kalman's filter method. The data was reasonable when there is an alarm messages for asking questionnaire. The response ratio were different in occupants' thermal condition. In conclusion, the filtered occupants' thermal sensation can be used as a real time HVAC control and input value of HVAC control.

An Approach of Indoor thermal Environment Control and Energy Saving Using the PMV Index (PMV지표를 이용한 공동주택의 난방제어에 따른 온열환경 및 에너지소비량 시뮬레이션)

  • Seong, Nam-Chul;Yoon, Dong-Won
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • Thermal comfort provide satisfaction of thermal environment and affects productivity of occupants in residential building. However, temperature control can not provide the thermal comfort at all the time. because thermal comfort is influenced by many environmental variables such as temperature, relative humidity, air velocity, radiation temperature, activity level and clothing insulation. The purpose of this study is that predicted mean vote(PMV) index is used as control. And, Thermal comfort is evaluated both PMV control and temperature control by simulation. Each other cases were compared, in which set-point temperatures of $22^{\circ}C$ and $24^{\circ}C$ and, set-point PMV index through the respective heating season in the simulation. The results show that PMV control is better to maintain comfort state and save energy than temperature control.

A Study on the Mechanical and Comfort Performances of the Working Uniform for a Volunteer Fire Brigade Member (의용소방대용 근무복 소재의 역학적 특성 및 쾌적성에 관한 연구)

  • Kwon, Myoung-Sook;Shim, Huen-Sup;Kwon, Jin
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.3 s.112
    • /
    • pp.53-62
    • /
    • 2007
  • The purpose of this study was to investigate mechanical and comfort performances of the material for the improved working uniform for a volunteer fire brigade member, to get basic data for its evaluation and to help its material and design development. The results were as follows; The material of the newly developed working uniform was thinner and lighter than the material of the current used working uniform. It had better breathability, air permeability and heat transmission rate than the current one. It also had superior anti-flammability In all mechanical properties(tensile, bending, shearing, compression and surface properties), it showed better performances than the current one. It elongated and bended easier and more in both warp and weft directions. The elastic recovery and shape stability after elongation were also higher. The recovery and resistance to shearing and the resiliency and recovery after compression were also better than the current one. It was more flexible, softer and smoother in primary hand value, and was more suitable for the material for winter suit which needs softness and fullness in total hand value. The material of the improved working uniform showed lower thermal insulation value and higher evaporative resistance value compared to the material of the currently used working uniform from the sweating thermal manikin test. It was shown that the physical performances and the hand value of the textile material used in the newly developed working uniform for a volunteer fiber brigade member was improved compared to the one used in the currently used working uniform.

Development and Evaluation of Smart Foundation with Heating Devices (발열장치를 이용한 보온 기능성 스마트 파운데이션의 개발 및 평가)

  • Hwang, Young-Mi;Lee, Jeong-Ran
    • Fashion & Textile Research Journal
    • /
    • v.15 no.2
    • /
    • pp.231-239
    • /
    • 2013
  • This research developed a smart girdle for adult women in their 20's that has an inserted carbon weaving heater to help with relief from coldness and abdominal disease through the thermal insulation effect. A pocket of powernet fabric was attached to the inside of the girdle for the easy insertion and separation of the heating device, while the heating device was fixed to a mesh material by cotton yarn and was wrapped with elastic lining material to prevent the mechanical devices from being exposed. A set of 3 hooks was attached to the center of the back of the heating device in consideration of convenience and mobility. Whereas the switch was inserted into around the right waistband, and the battery into the inner pocket around the waist, to integrate the heating device with the girdle. The satisfaction and usability of the fabricated smart girdle was verified by having research participants wear it to evaluate the appearance change caused by the device, the inconvenience of wearing/unwearing, mobility, and the satisfactory functionality of the device. As a result, the grand mean was evaluated to be high, with appearance (4.19), mobility (4.17), and functionality (4.51) being higher than 4.00; which indicates that the heat generation function of the smart girdle is effective. It may be said that such collection and analysis of data that reflect users' opinions have value and significance in that they can be grafted onto future research on new technology as well as they contribute to taking a step forward in the rapidly increasing research of smart clothing, with the new-type clothing equipped with new function.

The Evaluation on Thermal Window High-Tight Composition of Sliding Door and Open Door (여닫이와 미닫이를 복합한 고기밀성 단열창호 성능평가)

  • Choi, Dong-Hyuk;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.724-729
    • /
    • 2009
  • Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. To reduce the loss of the energy which leads, to an air conditioning energy and an expense increase problem the color which the interior furniture and the clothing due to the augmentation and the corpse ultraviolet rays of the unpleasant feeling which is caused by with the transient one solar energy influx which leads the window will burn, it joins in the window and it confronts and the novel solution is demanded.

  • PDF

A Study on the Standard Test Method for Thermal Resistance of Military Textile Thermal Insulator for Winter Season (방한을 목적으로 하는 군용 섬유제품 충전재의 보온성 시험방법에 대한 표준화 연구)

  • Yeo, Yong-heon;Hong, Seong-don;Lee, Min-hee;Kim, Kyung-pil;Chung, Il-han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.492-500
    • /
    • 2018
  • The performance evaluation of cold weather clothing is mainly carried out with thermal resistance. However, the results of the revised test method regarding the same specimen were decreased compare to previous one. In addition, there were deviations of the results among the authorized testing institutes according to the different interpretation of the KS test method. This makes it a considerable difficulty to the quality assurance of combat supplies. The purpose of this study is to minimize the variation of the results before and after the revision by analyzing the cause of the decrease in the heat insulation rate according to the revised test method. For this purpose, the difference between the test conditions before and after the revision of KS is analyzed and the possible results are reviewed. In addition, we want to minimize the result deviation between testing laboratories by analyzing the cause of the result deviation between test laboratories according to arbitrary interpretation of the standard. Based on this, we propose a standardized test method to prevent the decrease of the heat insulation rate by checking the pre-revision test method and the condition with the least deviation.

Fatigue Phenomenon of Mechanical Properties in Tencel Fabrics by Repeated Washing & Shear and Tensile Deformation (반복세탁 및 전단·인정변형에 따른 텐셀직물의 피로도)

  • Kwon, Oh-Kyung;Yi, Chang-Mi;Kim, Myo-Hyang;Park, Hee-Ung
    • Fashion & Textile Research Journal
    • /
    • v.1 no.3
    • /
    • pp.288-295
    • /
    • 1999
  • This study was conducted to examine the fatigue phenomenon of mechanical properties in tencel fabrics by repeated washing & shear and tensile deformation. The obtained results are as follows. After performing repeated shear tensile deformation, RT of tencel showed higher increase rate than that of cotton and rayon, whereas its WT and EM was a smaller decrease rate than that of them. This means that tencel's resistance to tensile deformation was the greatest. In the repeated washing and shear tensile deformation, tencel's 2HB, 2HG and 2HG5 showed a remarkable increase rate. In terms of deformation frequency, the greatest change rate appeared at the time of 1000 cycles of repeated shear tensile deformation and 15 times of repeated washing. In the hand value and THV, KOSHI showed a higher increase rate for tencel than for cotton and rayon in both repeated washing and shear tensile deformation, and NUMERI showed a higher increase rate. In the THV the change rate of rayon and cotton could be rarely seen but for tencel, it decreased. tencel's change rate of thermal insulation value by materials was 1.08%, and it increased as the washing frequency increased, compared to the grey fabrics, whereas the change rates of cotton and rayon were 0.74% and 0.22%, respectively. The qmax decreased in the order of cotton>tencel>rayon as the washing frequency increased.

  • PDF