• 제목/요약/키워드: thermal insulating materials

검색결과 171건 처리시간 0.034초

대형 터빈 발전기용 고정자 권선의 1000 thermal cycle 후 전기적 특성 변화 (Electrical Degradation of Stator Bars for Large Turbine Generator after 1000 Thermal Cycles)

  • 강명국;김태희;이재권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.975-976
    • /
    • 2007
  • Thermal and mechanical stresses, caused by repetitive start and stop and load fluctuation during long time operation, on winding stator bars are one of the main causes for electrical degradation of insulating materials. To understand the degradation process, we manufactured bar specimens with the same processes that make generator winding stator bars and the specimens were subjected to various degrees of thermal cycling. Measurements of the insulation properties, such as dissipation factor, tip-up and partial discharge, for un-aged specimens and for specimens aged by thermal cycling at 50, 100, 250, 500 and 1000 thermal cycles were performed. Finally all specimens were tested to obtain electrical breakdown voltages. In this paper we present the data and electrical degradation analysis results obtained during this program.

  • PDF

고압절연용 Epoxy/Organoclay Nanocomposites의 열적, 전기적 특성에 관한 연구 (Thermal, Electrical Characteristics according to Contents Variation of Epoxy/Organoclay Nanocomposites for High Voltage Insulation)

  • 박재준;안준오
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.226-227
    • /
    • 2007
  • Nanostructured materials are attracting increased interest and application. Exciting perspectives may be offered by electrical insulation. Epoxy/Organoclay nanocomposites may find new and upgraded applications in the electrical industry, replacing conventional insulation to provide improved performances in electric power apparatus, e.g, high voltage motor/generator stator winding insulation, dry mold transformer, etc. This paper shows that electrical and thermal properties of epoxy/organoclay nanocomposites insulating materials for dsc, dielectric constant, I-V characteristics, breakdown volatge, can improve significantly with respect to the basic, virgin materials.

  • PDF

무기질 충진재와 폴리우레탄을 활용한 유·무기 복합 단열소재의 특성 평가 (Evaluation of Organic-Inorganic Hybrid Insulation Material Using Inorganic Filler and Polyurethane)

  • 이종규;소정섭;노현경
    • 한국재료학회지
    • /
    • 제22권11호
    • /
    • pp.604-608
    • /
    • 2012
  • Recently, inorganic-organic hybrid materials have attracted much attention not only for their excellent thermal conductivity but also for their flame retardant properties. In this study, the properties of organic-inorganic hybrid insulating materials using inorganic fillers and polyurethane foam with different foaming conditions have been investigated. The addition of 1.5 wt% water to polyurethane as foaming agent shows the best foaming properties. The pore size was decreased in the foaming body with increasing of the $CaCO_3$ addition. The apparent density and thermal conductivity were increased by increasing the $CaCO_3$ addition. With an increasing amount of $CaCO_3$ powder, the flame retardant property is improved, but the properties of thermal conductivity and apparent density tend to decrease. When the addition of fine particles of $CaCO_3$, the apparent density and thermal conductivity were increased and, also, with the addition of coarse particles over $45{\mu}m$ in size, the apparent density and thermal conductivity were increased as well. In this study, the adding of $CaCO_3$ with average particle size of $27{\mu}m$ led to the lowest thermal conductivity and apparent density. After evaluation with different inorganic fillers, $Mg(OH)_2$ showed the highest thermal conductivity; on the other hand, $CaCO_3$ showed the lowest thermal conductivity.

발포유리 원료로서 폐 유리의 물리 화학적 특성 (Physical and Chemical Properties of Waste Glass as Feed Materials for the Production of Foamed Glass)

  • 이철태
    • 공업화학
    • /
    • 제16권3호
    • /
    • pp.440-448
    • /
    • 2005
  • 폐 유리병을 비롯한 폐 유리들을 대상으로 이들을 세척 또는 불순물의 분리 등 전처리를 하지 않고 건축용 단열재로서 발포유리 제조를 위한 원료로서의 적용 가능성 여부를 타진하기 위하여 폐 병유리, 폐판유리 및 LCD 유리 등의 물리화학적 특성을 조사하였다. 이를 위해서 폐 유리의 화학적 성분 분석, 열분석, 결정학적 분석, 점성, 유변학적 분석을 시행하였으며 이 결과를 바탕으로 정성적인 발포유리 제조도 시도하였다. 모든 분석 및 검토의 결과 및 폐 유리병 및 판유리는 발포유리의 제조 원료로서 충분한 사용가능성을 보여 주었다.

생석회와 실리카퓸을 활용한 경량기포콘크리트(ALC)의 강도특성 개선을 위한 실험적 연구 (An Experimental Study on the Strength Characteristic Improvement of the Autoclaved Lightweight Concrete(ALC) containing Quicklime and Silica Fume)

  • 김영호;송훈
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권4호
    • /
    • pp.21-27
    • /
    • 2011
  • These materials in architecturally glass or metal have weaknesses such as inadequate insulating quality, combustibility and toxic gases in fires substance. However, Autoclaved Lightweight Concrete(ALC) has excellent thermal insulation properties and seem to possess the superb insulating quality as substitute of existing exterior materials. This research is to compare experimentally to the kind of the strength properties of ALC materials which mixed with blast furnace slag pounder and silica fume. For the purpose of increasing the strength, the plastic states of ALC evaluate the physical characteristics as microstructure and strength according to various specific gravity. According to the quicklime quantity the compressive strength is proportionate depend on the absolute dried specific gravity. When not putting in 10% quicklime, the compressive strength appeared most lowly with 14.0MPa. When putting in the quicklime, the strength appeared higher with 15.1MPa. And strength of specimen containing 2.25% silica fume is 15.6MPa increased 10.3% than reference specimen 14.0MPa.

건식 유리섬유 심재를 사용한 진공단열재의 단열특성에 관한 연구 (A Study on the Thermal Insulation Performance of Vacuum Insulation Panel Using Dry Processing Glass Fiber Core)

  • 유채중;김민철;고성석
    • 대한건축학회논문집:구조계
    • /
    • 제35권6호
    • /
    • pp.121-128
    • /
    • 2019
  • There is a big move to build zero-energy buildings in the form of passive houses that reduce energy waste worldwide. Korea has set a goal of reducing its greenhouse gas emissions by 37% by 2030 through the activation of green buildings, such as strengthening the energy levels of new buildings and improving the energy efficiency of existing buildings. The use of insulation with high insulation performance is one of the key technologies to realize this, and vacuum insulation is the next generation insulation that blocks the energy flow of the building. In this study, we measured the bonding structure of dry and wet processing glass fiber core materials and compared the insulation performance of vacuum insulation panel. In addition, the insulation performance of vacuum insulation panel was measured according to the thickness of the laminated core. It can be confirmed that the lamination structure of the core and the lamination thickness are important factors for the heat insulating performance of the vacuum insulating panel.

HVDC용 나노복합 절연재료의 DC절연파괴특성 연구

  • 정의환;윤재훈;이승수;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.155-155
    • /
    • 2009
  • This paper introduces the findings of a detailed study on breakdown voltage strength under DC voltage and the development of HVDC cable. Recently, Nano-fillers are attracting attentions of many researchers and engineers, since they seem to bring higher potentials for advancement of electrical insulating properties as nano-composites. Additives and fillers are often adopted to polymeric materials for improving insulating and machanical properties. We have improved the polymer composition and developed a new insulation material for HVDC cable. Each specimen blended at LDPE1 to antioxidant, LDPE2 to antioxidant, pure XLPE was manufactured respectively. The insulation performances of the proposed insulator were compared with specimens blended at nano powders. DC breakdown strength of LDPE1 specimen at 90[$^{\circ}C$] was higher than other specimens. The experimental results show that polar groups intorduced in moleculars chains of blended specimen plays an important role in enhancement of thermal conductivity.

  • PDF

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

친환경 건축물 단열재 최근 연구 동향 (Recent Research Trends for Green Building Thermal Insulation Materials)

  • 박종문;김동환;서동진
    • 청정기술
    • /
    • 제18권1호
    • /
    • pp.14-21
    • /
    • 2012
  • 친환경 건축물에 사용되는 미네랄울, 폴리우레탄 등 전통적인 단열재로부터 최근에 주목받고 있는 VIP (Vacuum Insulation Panel), 에어로젤, 그리고 미래기술로 연구되고 있는 VIM (Vacuum Insulation Material), DIM (Dynamic Insulation Material) 등 단열재 및 단열 시스템의 특성과 장단점을 비교하였다. 매우 낮은 열전도율을 지닌 VIP 및 에어로젤은 기존 단열재에 비해 에너지 소모를 줄일 수 있으므로 주거면적을 크게 확대할 수 있는 장점이 있으며, 특히 에어로젤은 반투명 및 투명재질로 만들 수 있어 건물에 응용될 수 있는 가능성이 매우 크다. 단열재는 낮은 열전도율뿐만 아니라, 건설현장 응용성, 기계적강도, 내화성, 비용 및 환경영향 등을 고려하여야 하므로, 전통적인 단열재 및 최신 단열재를 활용하고 지속적으로 개선시키는 노력을 해야 할 것이다.

액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성 (Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen)

  • 이상화;신우주;;오석호;성재규;이방욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF