• 제목/요약/키워드: thermal index

검색결과 853건 처리시간 0.025초

Evaluation of Thermal Comfort on Protective Clothing Worn in an Radiation Power Plant

  • Kim, Eun-Joo;Han, Myung-Sook;Lee, Won-Ja
    • The International Journal of Costume Culture
    • /
    • 제3권1호
    • /
    • pp.30-40
    • /
    • 2000
  • The purpose of this research was to device thermal comfort model for radiation power plant workers in protective clothing. Three fabrics commonly used in protective workwear were made into coveralls of identical design and were evaluated by adult healthy males in four simulated work environment. It was investigated between the physiological response and subjects comfort according to environmental variance and clothing types. The of simulated work enviro mensent was controlled under four different humidity and temperature of each type. (Temperature 20±1℃, RH 40∼70%±5%, Temperature 30±1℃, RH 40∼70%±5%) An index of physiological response was connected with the thermal comfort designed. Mean skin temperature, skim temperature, Axillasy temperature ear canal temperature, clothing climate, total sweat, blood pressure, and R-R interval were be evaluated. Skin temperature difference ocurring during exercise and rest were significant only with respect to time and regions of the body, This despite physical differences in the three coveralls, particulary mass statistically experiment. Also, an index of subject wearing sensation was designed for thermal comfort after investigation determined the kind of clothes and the type of environment. As a result of this research, two types of multiple regressions was deviced to estimate thermal comfort of the protective clothing.

  • PDF

파이프쿨링을 실시한 대형 프리스트레스트 콘크리트 슬래브의 수화열 해석 (Numerical analysis of temperature and stress distributions in a prestressed concrete slab with pipe cooling)

  • 주영춘;김은겸;신치범;조규영;박용남
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.275-280
    • /
    • 1999
  • It was analysed the effect of pipe cooling as a measure to avoid thermal cracks due to the heat of hydration during the curing process of a massive prestressed concrete (PSC) slab. PSC slab has a complex three-dimensional shape of which the maximal and minimal thicknesses of cross-section were 2.8 and 0.95m, respectively. Steel pipes of which the diameter was 1 inch were employed for cooling. The horizontal and vertical distances between the contiguous pipes were 0.5 and 0.6m, respectively. One the four layers of cooling pipe were arranged according to the thickness of cross-section. Temperature distribution was calculated by the program developed by the authors, of which the accuracy was verified on a few published papers by the authors. Based on the temperature analysis of the cross-section which had four layers of cooing pipe, the maximum temperature of concrete interior was 54.2$^{\circ}C$ and the maximum differenced between the interior and surface temperatures of concrete was 14.$0^{\circ}C$ and, thereby, the thermal cracking index was 1.1. Upon the stress analysis, the thermal cracking index was 0.92 and the probability of thermal-crack development was 52%. Therefore, it was expected to make it possible to reduce the probability of thermal-crack development in a massive PSC slab by adopting pipe cooling.

  • PDF

대수층 계간 축열시스템 적용을 위한 지하수의 화학적 특성 변화 (The Influences of Aquifer Thermal Energy Storage (ATES) System on Geochemical Properties of Groundwater)

  • 최한나;이홍진;심병완
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권3호
    • /
    • pp.14-24
    • /
    • 2021
  • Aquifer thermal energy storage (ATES) system uses groundwater thermal energy for cooling and heating of buildings, and it is also often utilized to provide warm water to crops and plants for the purpose of enhancing agricultural yields. This study investigated the potential influences of a ATES system on the geochemical properties of groundwater by simulating the variation of hydrochemistry and saturation index of groundwater during ATES operation. The test bed was installed at an agricultural field, which is mainly composed of an groundwater-rich alluvial plain. The simulation results showed no significant precipitation of mineral phases such as manganese-iron oxide, carbonate and sulfate around the ATES test bed, as well as no debasement of other important water quality parameters. The implementation of ATES system in the study area was appropriate and effective for utilizing the thermal energy of groundwater for agricultural use.

공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석 (Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened -)

  • 최동호
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

한국 난온대 식생분포대의 식물기후학적 재검토 (A Phytoclimatic Review of Warm-temperate Vegetation Zone of Korea)

  • 엄병철;김종원
    • 생태와환경
    • /
    • 제53권2호
    • /
    • pp.195-207
    • /
    • 2020
  • 난온대 동백나무군강의 한국 내 분포 북한계는 연평균 기온 13℃와 14℃, 한랭지수 -10℃로 제안된 바 있다. 본 연구는 이들 기후요소의 지리적 공간분포 실체를 검토하였다. 세 기후요소의 공간분포 양상은 티센망법과 크리깅법으로 분석하였으며, 세 가지 기후도를 생산하여 난온대 주요 상록활엽수종의 현존분포와 그 대응성을 비교·분석하였다. 결과로 난온대 식생의 분포 북한계는 한랭지수 -10℃가 연평균기온 14℃보다 일치하였으나, 연평균기온 13℃가 더욱 정교한 일치를 보여주었다. 한반도에서 연평균기온 13℃를 북한계로 한 난온대 식생역의 잠재 분포 면적은 20,334 ㎢로 다른 두 온도요소의 경우보다 넓었다. 본 연구는 가공하지 않은 직접 기후요소인 연평균기온 13℃가 가공으로부터 생겨난 간접 기후요소인 한랭지수 -10℃보다 난온대 식생 분포 북한계에 대응하는 특정 온도 요소인 것으로 밝혀졌다. 더불어 식물구계학적 특정종의 평가 기준으로 사용되는 난온대 경계선에 대한 학술적 재고의 필요성이 대두되었다.

하이브리드 로켓 연소에서의 경계층 진동 변화와 저주파수 연소불안정 (Oscillating Boundary Layer Flow and Low Frequency Instability in Hybrid Rocket Combustion)

  • 김진아;이창진
    • 한국항공우주학회지
    • /
    • 제47권10호
    • /
    • pp.720-727
    • /
    • 2019
  • 하이브리드 로켓 연소의 저주파수 연소불안정은 고체연료의 열적지연(Thermal Lag)과 경계층 유동 변화에 의한 열전달 진동의 공진에 의해 발생한다. 본 연구는 연료 표면 근처의 경계층 유동의 교란이 어떤 물리적 과정에 의해 발생하여 연소불안정으로 발달하는지를 실험적으로 확인하였다. 특히 산화제의 스월 분사는 연소 안정화에 매우 큰 기여를 하므로 스월 강도를 증가시키며 경계층의 변화와 연소불안정의 발생과정을 연구하였다. 경계층 섭동을 확인하기 위하여 연소 유동장을 가시화하였고 이미지에 대한 POD(Proper Orthogonal Decomposition) 분석을 시도하였다. 스월 강도가 증가할수록 500Hz 대역 고주파수 p', q'의 결합이 약해지며 열적지연과 유사한 주파수 특성을 갖는 Rayleigh Index의 섭동 발생도 약해져 경계층 진동의 발생이 점차 감소하는 것을 관찰하였다. 따라서 고주파수 p', q'의 주기적인 결합에 의한 축 방향 경계층 진동이 나타나면 열적지연 주파수와 공진에 의한 연소불안정이 발생함을 확인하였다.

Vibration and stability of initially stressed sandwich plates with FGM face sheets in thermal environments

  • Chen, Chun-Sheng;Liu, Fwu-Hsing;Chen, Wei-Ren
    • Steel and Composite Structures
    • /
    • 제23권3호
    • /
    • pp.251-261
    • /
    • 2017
  • In this paper, thermal effect on the vibration and stability of initially stressed sandwich plates with functionally graded material (FGM) face sheets is analyzed. Material properties of FGM face sheet are graded continuously in the thickness direction. The variation of FGM properties assumes a simple power law distribution in terms of the volume fractions of the constituents. The governing equations of arbitrarily initially-stressed sandwich plates including the effects of transverse shear deformation and rotary inertia are derived. The initial stress is taken to be a combination of a uniaxial extensional stress and a pure bending stress in the examples. The eigenvalue problems are formed to study the vibration and buckling characteristics of simple supported initially stressed FGM/metal/FGM plates. The effects of volume fraction index, temperature rise, initial stress and layer thickness of metal on the natural frequencies and buckling loads are investigated. The results reveal that the volume fraction index, initial stresses and layer thickness of metal have significant influence on the vibration and stability of sandwich plates with FGM face sheets.

FBG를 이용한 파장가변 형 전광 필터의 고온 특성에 관한 연구 (A Study on the High-Temperature Characteristics of a Tunable All-Optical Filter Using Fiber Bragg Grating)

  • 손용환;양세훈;김현승;한상국
    • 전기전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.263-269
    • /
    • 2010
  • 본 논문에서는 Germanium 및 Germanium과 Boron이 도핑 된 광섬유의 FBG를 이용한 파장가변 형 전광 필터의 고온 특성을 고찰하고, 온도 변화에 대한 파장가변 형 FBG 필터의 반사도, 선폭, 정규화 굴절률 차의 특성 변화를 수치해석을 통해 비교 고찰 하였다. 굴절률 차의 변화에 따른 FBG 필터의 반사 스펙트럼은 온도 안정성에 영향을 받으며, Germanium이 도핑 된 광섬유의 FBG 필터가 Germanium과 Boron이 도핑 된 광섬유의 FBG 필터보다 온도변화에 더 안정성을 가짐을 알 수 있다. 또한 $500^{\circ}C$ 까지의 온도에 대해서는 두 가지 모두 필터로서 온도변화에 안정성을 가짐을 알 수 있다.

Vibrations and thermal stability of functionally graded spherical caps

  • Prakash, T.;Singh, M.K.;Ganapathi, M.
    • Structural Engineering and Mechanics
    • /
    • 제24권4호
    • /
    • pp.447-461
    • /
    • 2006
  • Here, the axisymmetric free flexural vibrations and thermal stability behaviors of functionally graded spherical caps are investigated employing a three-noded axisymmetric curved shell element based on field consistency approach. The formulation is based on first-order shear deformation theory and it includes the in-plane and rotary inertia effects. The material properties are graded in the thickness direction according to the power-law distribution in terms of volume fractions of the constituents of the material. The effective material properties are evaluated using homogenization method. A detailed numerical study is carried out to bring out the effects of shell geometries, power law index of functionally graded material and base radius-to-thickness on the vibrations and buckling characteristics of spherical shells.

광 파이버 브래그 격자를 이용한 파장가변형 필터의 온도 특성에 관한 연구 (A Study on the Thermal Characteristics of Tunable Filter Using Fiber Bragg Grating)

  • 손용환;이종윤;허주옥;정진호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.635-638
    • /
    • 2005
  • In this paper, we present thermal characteristics of a fiber Bragg grating(FBG) filter, including peak reflectivity, FWHM bandwidth, and wavelength shift by various refractive index change. The reflection spectrum of a FBG filter with refractive index change is affected by its thermal stability.

  • PDF