• Title/Summary/Keyword: thermal index

Search Result 855, Processing Time 0.029 seconds

Thermal stability of functionally graded sandwich plates using a simple shear deformation theory

  • Bouderba, Bachir;Houari, Mohammed Sid Ahmed;Tounsi, Abdelouahed;Mahmoud, S.R.
    • Structural Engineering and Mechanics
    • /
    • v.58 no.3
    • /
    • pp.397-422
    • /
    • 2016
  • In the present work, a simple first-order shear deformation theory is developed and validated for a variety of numerical examples of the thermal buckling response of functionally graded sandwich plates with various boundary conditions. Contrary to the conventional first-order shear deformation theory, the present first-order shear deformation theory involves only four unknowns and has strong similarities with the classical plate theory in many aspects such as governing equations of motion, and stress resultant expressions. Material properties and thermal expansion coefficient of the sandwich plate faces are assumed to be graded in the thickness direction according to a simple power-law distribution in terms of the volume fractions of the constituents. The core layer is still homogeneous and made of an isotropic material. The thermal loads are considered as uniform, linear and non-linear temperature rises within the thickness direction. The results reveal that the volume fraction index, loading type and functionally graded layers thickness have significant influence on the thermal buckling of functionally graded sandwich plates. Moreover, numerical results prove that the present simple first-order shear deformation theory can achieve the same accuracy of the existing conventional first-order shear deformation theory which has more number of unknowns.

Thermal buckling of functionally graded sandwich plates using a new hyperbolic shear displacement model

  • Kettaf, Fatima Zohra;Houari, Mohammed Sid Ahmed;Benguediab, Mohamed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.15 no.4
    • /
    • pp.399-423
    • /
    • 2013
  • In the present study, the thermal buckling behavior of functionally graded sandwich plates is studied using a new hyperbolic displacement model. Unlike any other theory, the theory is variationally consistent and gives four governing equations. Number of unknown functions involved in displacement field is only four, as against five in case of other shear deformation theories. This present model takes into account the parabolic distribution of transverse shear stresses and satisfies the condition of zero shear stresses on the top and bottom surfaces without using shear correction factor. Material properties and thermal expansion coefficient of the sandwich plate faces are assumed to be graded in the thickness direction according to a simple power-law distribution in terms of the volume fractions of the constituents. The core layer is still homogeneous and made of an isotropic material. The thermal loads are assumed as uniform, linear and non-linear temperature rises across the thickness direction. The results reveal that the volume fraction index, loading type and functionally graded layers thickness have significant influence on the thermal buckling of functionally graded sandwich plates.

Spatiotemporal Changes of the Thermal Environment by the Restoration of an Inner-city Stream (도시 내부 하천 복원에 의한 열 환경의 시공간적 변화)

  • Kwon, Tae Heon;Kim, Kyu Rang;Byon, Jae-Young;Choi, Young-Jean
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.321-330
    • /
    • 2009
  • Spatiotemporal changes in the thermal environment in a large city, Seoul, Korea were analyzed using a thermal index, perceived temperature (PT), to standardize the weather conditions. PT is a standard index for the thermal balance of human beings in thermophysiological environment. For the analysis of PT, the data from long-term monitoring and intensive observations in and around the inner-city stream called 'Cheonggye' in Seoul, were compared with a reference data from the Seoul weather station. Long-term data were monitored by installing two automatic weather stations at 66m (S1) and 173m (S2) away from the center of the stream. Through the analysis of the data during the summer of 2006 and intensive observation periods, it was revealed that the stream's effects on the PT extended up to the distance of the S1 site. In winter, the increase of the PT between pre- and post-restoration was stronger at S1, which was nearer than S2 from the stream. These results suggest that PT can be used as an effective model in analyzing the changes of the thermal environment in relation with the changes of water surface areas.

A Study on Evaluation of Thermal Environment using Heat Stress Indices for Deep Coal Mine in Korea (열적지표를 적용한 국내 고심도 석탄광산의 열환경 평가 연구)

  • Park, Seon-Oh;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.166-175
    • /
    • 2014
  • In this study, the thermal environment in a large scale coal mine located in Taebaek, Gangwondo was assessed by a field survey. In order to estimate the thermal environment, various heat stress indices such as WBGT, HSI, ESI, KATA index and effective temperature were investigated. Correlation analysis was also conducted. It was found that the thermal environment in most workplace was high. In particular, the correlation coefficient between HSI reflected in physiological fatigue characteristic and the maximum sweat evaporation heat was -0.834. This shows that the correlation coefficient have the most influence on HSI index. The factor which has the most influence on the maximum sweat evaporation heat is velocity of air. The thermal environment of high-depth coal mines is likely to be improved by installing a structure that enables the maximum prevention of extended digging, air doors, or the leakage of the inflow of air in the first shaft.

Body Composition Analysis Study of Postpartum Women With Cold-Hypersensitivity (수부냉증이 있는 산모의 체성분학적 특성 분석)

  • Lee, Mi-Joo;Lee, Chang-Hoon;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.9 no.1
    • /
    • pp.22-28
    • /
    • 2011
  • Purpose :To analyze body composition in postpartum women with cold-hypersensitivity, their edema index, skelectal muscle's weight and body fat were measured and analyzed with cold hypersensitive postpartum women compared with those of non-cold hypersensitivity. Methods : We studied 38 postpartum women visiting Gangnam Kyung-Hee Korean Hospital from 1 st October 2010 to 30th september 2011. they were subjected to Digital Infrared Thermal Imaging and those with thermal difference greater than $0.3^{\circ}C$ between anterior forearm and center of hand were diagnosed with cold hypersensitivity. Cold hypersensitivity group were consisted of 11 women, the other were consisted of 26 women. All of them were measured Edema index, skelectal muscle's weight and body fat by Inbody720(body composition scanner). We studied the difference of Body composition factor between two groups and relationship between cold-hypersensitivity, Edema index, skelectal muscle's weight and body fat by Independent Samples T-test and Spearman Correlation. Results : No significant differences were observed in edema index, skelectal muscle's weight and body fat between two groups. Conclusion : There was no significant relationship among the Cold-hypersensitivity and Body composition factor(Edema index, skelectal muscle's weight. body fat). But furthemore large scale study is required.

  • PDF

Analyzing Change of Discomfort Index for Transpiration of Street Tree (도시 가로수의 증산 작용으로 인한 불쾌지수 변화 분석)

  • Yun, Seok-Hwan;Lee, Dong-Kun;Park, Chae-Yeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.29-43
    • /
    • 2020
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. The cooling effect of street tree is regarded as a effective way to ameliorate the urban heat environment. The effect is largely made up of shadow formation and transpiration. This study aims to identify how the transpiration affects the discomfort index by analyzing comprehensive impact of the transpiration on the air temperature and relative humidity. The changes in the amount of transpiration, air temperature, and relative humidity were estimated for Seogyo-dong area which has a lot of floating population in Seoul, at 2 p.m. in dry day in July and August. On average, the transpiration of the street tree decreased the temperature 0.3℃ and increased the relative humidity 2.6% in an hour. As a result of these changes in temperature and humidity, the discomfort index rose mostly(0.036 on average). It was always get rise especially on the day when the discomfort index was above 80(0.05 on average). However, compared with the significant change in temperature and humidity, the variation of the discomfort index itself was very slight(up to 0.107). Therefore, the effect of transpiration by the street trees might not be effective in the planning to improve the thermal environment(especially on the day when the discomfort index is high). It is necessary to select the species of trees and planting location considering the cooling effect of shade formation synthetically.

Forecast and verification of perceived temperature using a mesoscale model over the Korean Peninsula during 2007 summer (중규모 수치 모델 자료를 이용한 2007년 여름철 한반도 인지온도 예보와 검증)

  • Byon, Jae-Young;Kim, Jiyoung;Choi, Byoung-Cheol;Choi, Young-Jean
    • Atmosphere
    • /
    • v.18 no.3
    • /
    • pp.237-248
    • /
    • 2008
  • A thermal index which considers metabolic heat generation of human body is proposed for operational forecasting. The new thermal index, Perceived Temperature (PT), is forecasted using Weather Research and Forecasting (WRF) mesoscale model and validated. Forecasted PT shows the characteristics of diurnal variation and topographic and latitudinal effect. Statistical skill scores such as correlation, bias, and RMSE are employed for objective verification of PT and input meteorological variables which are used for calculating PT. Verification result indicates that the accuracy of air temperature and wind forecast is higher in the initial forecast time, while relative humidity is improved as the forecast time increases. The forecasted PT during 2007 summer is lower than PT calculated by observation data. The predicted PT has a minimum Root-Mean-Square-Error (RMSE) of $7-8^{\circ}C$ at 9-18 hour forecast. Spatial distribution of PT shows that it is overestimated in western region, while PT in middle-eastern region is underestimated due to strong wind and low temperature forecast. Underestimation of wind speed and overestimation of relative humidity have caused higher PT than observation in southern region. The predicted PT from the mesoscale model gives appropriate information as a thermal index forecast. This study suggests that forecasted PT is applicable to the prediction of health warning based on the relationship between PT and mortality.

Identifying Process Capability Index for Electricity Distribution System through Thermal Image Analysis (열화상 이미지 분석을 통한 배전 설비 공정능력지수 감지 시스템 개발)

  • Lee, Hyung-Geun;Hong, Yong-Min;Kang, Sung-Woo
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.3
    • /
    • pp.327-340
    • /
    • 2021
  • Purpose: The purpose of this study is to propose a system predicting whether an electricity distribution system is abnormal by analyzing the temperature of the deteriorated system. Traditional electricity distribution system abnormality diagnosis was mainly limited to post-inspection. This research presents a remote monitoring system for detecting thermal images of the deteriorated electricity distribution system efficiently hereby providing safe and efficient abnormal diagnosis to electricians. Methods: In this study, an object detection algorithm (YOLOv5) is performed using 16,866 thermal images of electricity distribution systems provided by KEPCO(Korea Electric Power Corporation). Abnormality/Normality of the extracted system images from the algorithm are classified via the limit temperature. Each classification model, Random Forest, Support Vector Machine, XGBOOST is performed to explore 463,053 temperature datasets. The process capability index is employed to indicate the quality of the electricity distribution system. Results: This research performs case study with transformers representing the electricity distribution systems. The case study shows the following states: accuracy 100%, precision 100%, recall 100%, F1-score 100%. Also the case study shows the process capability index of the transformers with the following states: steady state 99.47%, caution state 0.16%, and risk state 0.37%. Conclusion: The sum of caution and risk state is 0.53%, which is higher than the actual failure rate. Also most transformer abnormalities can be detected through this monitoring system.

Rheological Properties of Rice Starches Gelatinized with Thermal or Alkali Solutions (가열 및 알칼리 호화에 의한 쌀 전분의 리올로지 특성)

  • Park, Yang-Kyun;Kim, Sung-Kon;Lee, Shin-Young;Kim, Kwan
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.57-61
    • /
    • 1991
  • Rheological properties of Tongjinbyeo(Japonica) and Samgangbyeo($J{\times}Indica$) rice starches gelatinized with thermal or alkali solutions were investigated with rotational viscometer(Brabender Viscotron). The two starches showed Bingham pseudoplastics behavior in $4{\sim}8%$ thermal or alkali gelatinized starch solutions. Rheological properties of thermal gelatinized starch solutions were similar between the two varieties. However, alkali gelatinized Samgangbyeo starch solutions showed higher values of yield stress and consistency index than that of Tongjinbyeo starch. The values of pseudoplasticity, yield stress and consistency index were higher in the thermal gelatinized samples than those of in the alkali gelatinized ones.

  • PDF