• 제목/요약/키워드: thermal impedance

검색결과 171건 처리시간 0.029초

Preparation of New Polyelectrolyte/ Silver Nanocomposites and Their Humidity-Sensitive Properties

  • Park, Min-Su;Lim, Tae-Ho;Jeon, Young-Min;Kim, Jong-Gyu;Gong, Myoung-Seon;Joo, Sang-Woo
    • Macromolecular Research
    • /
    • 제16권4호
    • /
    • pp.308-313
    • /
    • 2008
  • A simple strategy was developed based on polyelectrolyte/silver nanocomposite to obtain humidity-sensitive membranes. The major component of a humid membrane is the polyTEAMPS/silver nanocomposite obtained by thermal heating the mixture of a polyelectrolyte and silver isopropylcarbamate complex. Humidity sensors prepared from polyTEAMPS/silver (w/w=100/0 and 100/6) nanocomposites had an average impedance of 292, 8.83 and $0.86\;k{\Omega}$, and 5,327, 140 and $0.93\;k{\Omega}$ at 30,60 and 95% relative humidity (RH), respectively. Hysteresis, temperature dependence and response time were also measured. Activation energies and complex impedance spectroscopy of the various components of the polyelectrolyte/silver nanocomposite films were examined for the humidity-sensing membrane.

IDENTIFICATION OF TWO-DIMENSIONAL VOID PROFILE IN A LARGE SLAB GEOMETRY USING AN IMPEDANCE MEASUREMENT METHOD

  • Euh, D.J.;Kim, S.;Kim, B.D.;Park, W.M.;Kim, K.D.;Bae, J.H.;Lee, J.Y.;Yun, B.J.
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.613-624
    • /
    • 2013
  • Multi-dimensional two-phase phenomena occur in many industrial applications, particularly in a nuclear reactor during steady operation or a transient period. Appropriate modeling of complicated behavior induced by a multi-dimensional flow is important for the reactor safety analysis results. SPACE, a safety analysis code for thermal hydraulic systems which is currently being developed, was designed to have the capacity of multi-dimensional two-phase thermo-dynamic phenomena induced in the various phases of a nuclear system. To validate the performance of SPACE, a two-dimensional two-phase flow test was performed with slab geometry of the test section having a scale of $1.43m{\times}1.43m{\times}0.11m$. The test section has three inlet and three outlet nozzles on the bottom and top gap walls, respectively, and two outlet nozzles installed directly on the surface of the slab. Various kinds of two-dimensional air/water flows were simulated by selecting combinations of the inlet and outlet nozzles. In this study, two-dimensional two-phase void fraction profiles were quantified by measuring the local gap impedance at 225 points. The flow conditions cover various flow regimes by controlling the flow rate at the inlet boundary. For each selected inlet and outlet nozzle combination, the water flow rate ranged from 2 to 20 kg/s, and the air flow rate ranged from 2.0 to 20 g/s, which corresponds to 0.4 to 4 m/s and 0.2 to 2.3 m/s of the superficial liquid and gas velocities based on the inlet port area, respectively.

유량평형시험을 통한 환경제어계통 설계 검증 (Design Verification of Environmental Control System by Flow Balance Test)

  • 박동명;정용인;문우용;박성순
    • 한국항공우주학회지
    • /
    • 제40권7호
    • /
    • pp.608-615
    • /
    • 2012
  • 본 연구는 무인항공기의 항전베이와 환경제어계통이 가지고 있는 시스템 특성을 분석하여 항전장비에 공급되는 적정 유량을 예측하였다. 예측된 결과를 바탕으로, 각 토출구에서 토출되는 유량과 유량 분포를 분석하여 환경제어계통에 대한 성능을 분석함과 동시에 항전베이에 대한 열해석을 수행하여 유량 분포의 적절성을 입증하였다. 분석된 결과에 대한 타당성을 검증하기 위해 실제 환경제어계통을 이용하여 유량평형 시험장비를 구축하고, 유량평형시험을 수행하였으며, 항전장비의 시스템 요구조건에 부합되는 유량을 최종 도출하였다. 또한, 중고도 운용환경에서 시스템 요구조건의 충족여부를 검증하고 환경제어계통에 대한 열교환 성능을 입증하였다.

열차폐코팅의 비파괴적 손상 평가를 위한 고감도 와전류 센서 설계 (Designing a Highly Sensitive Eddy Current Sensor for Evaluating Damage on Thermal Barrier Coating)

  • 김종민;이슬기;김학준;송성진;석창성;이영제
    • 비파괴검사학회지
    • /
    • 제36권3호
    • /
    • pp.202-210
    • /
    • 2016
  • 열차폐코팅은 극한의 열환경에서 사용되는 기계요소를 고온으로부터 보호하기 위하여 널리 이용하는 코팅으로, 관련 산업의 경제적 이윤과 사용자 안전에 관련한 중요한 기술이다. 따라서 이런 열차폐코팅의 비파괴적 손상 평가는 그 중요성이 높이 평가되어 왔으나, 코팅 파쇄의 원인이 되는 내부의 미세한 조성 변화를 감지하기 위한 기술적 난제를 안고 있는 연구 주제이다. 본 논문은 열차폐코팅의 비파괴적 손상 평가를 위한 유한요소해석 기반 고감도 와전류 센서 설계 과정을 소개하고, 설계한 센서를 제작하여 진행한 성능 평가를 통해 설계 과정을 검증하였다. 와전류 센서의 성능을 예측하기 위하여 유한요소해석을 수행한 결과, 열차폐코팅의 손상 정도에 따른 센서의 임피던스가 증가와, 마그네틱 쉴드를 적용하였을 때 자속집속에 의한 검출능 향상을 관찰할 수 있었다. 또한 실제 실험결과와 비교를 통해 유한요소해석 결과를 검증하였다.

Hot Firing Test of a Quadrature NEA SSD9103S1 Configuration

  • Ja-Chun, Koo;Hee-Sung, Park;Max, Guba
    • International Journal of Aerospace System Engineering
    • /
    • 제9권2호
    • /
    • pp.1-9
    • /
    • 2022
  • The NEA release mechanism is used to provide restraint and release functions with low shock for critical deployment operations on solar arrays after launch. The GK3 solar array consists of 2 wings and 6 hold down points per panel. The NEA SSD9103S1 is a part of the GK3 solar array hold-down and release mechanism. Each NEA unit is equipped with two Z-diodes which provide power to a NEA unit connected in series after actuation of the fuse wire. This paper presents the hot firing test results of a quadrature NEA SSD9103S1 configuration. One output powers a maximum of 4 NEA SSD9103S1 units simultaneously. The necessary actuation pulse duration has been determined to meet margin requirement for thermal energy of minimum 4. Actuation thermal energy difference is about 6.6% between each half of two fired serial NEAs. Thermal energy margin at worst case is minimum 5.9 in case of an actuation pulse duration of 500 ms. Two series Zener impedance depend on current applied has been characterized by an additional actuation after all fuse wires are open circuit. Total number of actuation commands to the GK3 NEA unit reduce drastically from 24 in case of single NEA configuration down to 8 in case of parallel and quadrature NEA configurations. It can be accommodated by the existing HP2U Pyro design without any impact.

Comparison of Ablation Performance between Octopus Multipurpose Electrode and Conventional Octopus Electrode

  • Sae-Jin Park;Jae Hyun Kim;Jeong Hee Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • 제24권2호
    • /
    • pp.86-94
    • /
    • 2023
  • Objective: To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo. Materials and Methods: Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60℃ in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. Results: In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3, p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all). Conclusion: RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.

촉매 화학 기상 증착법의 제조 조건에 따른 탄소 나노튜브의 특성 (Characteristics of Carbon Nanotube with Synthetic Conditions in Catalytic Chemical Vapor Deposition)

  • 김현진;이임렬
    • 한국재료학회지
    • /
    • 제12권6호
    • /
    • pp.458-463
    • /
    • 2002
  • Carbon nanotubes were synthesized at various conditions using Ni-catalytic thermal chemical vapor deposition method and their characteristic properties were investigated by SEM, TEM and Raman spectroscopy. Carbon nanotubes were formed on very fine Ni-catalytic particles. The carbon nanotubes synthesized by thermal decomposition of acetylene at $700^{\circ}C$ had a coiled shape, while those synthesized at $850^{\circ}C$ showed a curved and Y-shape having a bamboo-like morphology. It was found that the carbon nanotube was also made on the fine Ni-catalytic particles formed on the surface of 100~400nm sized large ones after pretreatment with $NH_3$.ber composites show the high dielectric constant and large conduction loss which is increased with anisotropy of fiber arrangement. It is, therefore, proposed that the glass and carbon fiber composites can be used as the impedance transformer (surface layer) and microwave reflector, respectively. By inserting the foam core or honeycomb core (which can be treated as an air layer) between glass and carbon fiber composites, microwave absorption above 10 dB (90% absorbance) in 4-12 GHz can be obtained. The proposed fiber composites laminates with sandwitch structure have high potential as lightweight and high strength microwave absorbers.

열음향 냉장시스템 (I) : 음향학적 해석 및 설계 (Thermoacoustic Refrigerating System, Part I : Acoustic Analysis and Design Procedure)

  • 하재규;안철용;성굉모
    • 한국음향학회지
    • /
    • 제14권6호
    • /
    • pp.5-12
    • /
    • 1995
  • 본 논문에서는 열음향 냉장시스템을 음향적으로 해석하고 주어진 조건을 만족시키는 열음향냉장시스템의 설계방법을 제시하였다. 열음향 냉장시스템은 음파의 에너지를 단열팽창, 수축의 원리를 이용하여 열에너지로 변환시키는 열음향변환기이다. 열음향 냉장시스템은 일반 가정용 스피커 유닛을 사용하는 구동부, 실제의 온도 구배가 생기게 되는 스택 부분, 그리고 정상파를 생성시키는 본체 부분인 공명기 등으로 구성된다. 음향학적인 해석을 통해 주어진 조건을 만족시키도록 전체 공명기의 크기를 결정하고 스택의 크기와 위치를 설정하여 이에 따라 실제의 시스템을 설계하였다. 끝으로 설계된 공명기의 기계적 임피던스를 모의실험을 통해 구하였다.

  • PDF

저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구 (The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma)

  • 정종한;정현주;김휘영;정용호;송금영;김근용;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

Electrical properties and thermal stability of oxygen incorporated GeSbTe films

  • 장문형;박승종;임동혁;박성진;조만호;조윤호;이종흔
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.155-155
    • /
    • 2010
  • Oxygen incorporated $Ge_2Sb_2Te_5$ (GST) films were prepared by an ion beam sputtering deposition (IBSD) method. From the I-V curves, the $V_{th}$ value varies with the oxygen content. Ge-deficient hexagonal phases are responsible for the observed unstability and decrease in $V_h$ values. In the case of a GST film with an elevated oxygen content of 30.8 %, the GST layer melted at 9.02 V due to the instability conferred by the high oxygen content. The formation of Ge-deficient hexagonal phases such as $GeSb_2Te_4$ and $Sb_2Te_3$ appear to be responsible for the $V_{th}$ variation. Impedance analyses indicated that the resistance in GST films with oxygen contentsof 16.7 % and 21.7 % had different origins. Thermal desorption spectroscopy (TDS)data indicate that moisture and hydrocarbons were more readily desorbed at higher oxygen content because the oxygen incorporated GST films are more hydrophilic than undoped GST films.

  • PDF