• 제목/요약/키워드: thermal humidity

검색결과 644건 처리시간 0.027초

하계 남성복의 온열쾌적감에 관한 연구 - 실내 환경조건을 중심으로 - (A Study on Thermal Comfort of Korea Men감s Wear in Summer - Based on Indoor Environment conditions -)

  • 정상열;고경태
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 1997년도 추계총회 및 학술발표회 논문집
    • /
    • pp.364-368
    • /
    • 1997
  • The purpose of this Study was to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate Variability(HRV), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at 50% R.H., 24C, and the difference of skin temperature was found at the calf area as air temperature changes. At low air temperature and low humidity, heart rate was decreased, but there was no change at brain wave, keeping a-wave.

  • PDF

비열플라즈마에 의한 수소발생에 미치는 캐리어가스의 영향 (A study on the hydrogen generation's characteristics via non-thermal plasma and carrier gas)

  • 김종석;박재윤;정장근;김태용;고희석;이현우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.215-219
    • /
    • 2004
  • This paper is investigated about the effect of carrier gas and humidity for generating hydrogen gas. In the experimental result of generating hydrogen gas by non-thermal plasma reactor, the rate of generating hydrogen gas is different with what kind of carrier gas is. We used two types of carrier gas, such as $N_2$ and He. $N_2$ as carrier gas is more efficient to generate hydrogen gas than He because $N_2$ is reacted with $O_2$, which is made from water dissociation. In comparison with no humidity and humidity 45[%], the generation of hydrogen gas is decreased with increasing the humidity. That is the result that the energy for water dissociation is reduced on water surface because a part of plasma energy is absorbed at the small particle produced from humidifier.

  • PDF

PMV, TS 기준 건물 열 환경 제어법의 성능 및 적용성 분석 (Performance and Applicability of PMV-based and TS-based Building Thermal Controls)

  • 문진우
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.430-440
    • /
    • 2011
  • The purpose of this study was to investigate the interactions between the thermal factors in existing thermal control methods and to find out the control logic that can create more comfortable thermal conditions. For it, four thermal control logics were developed:conventional temperature-based control; temperature-based and humidity-based control; PMV-based control; and TS-based control. Their performance was comparatively tested in the U.S. typical 5-story office building in two climate zones (Detroit, Michigan and Miami, Florida) for two seasons (winter and summer) incorporating IBPT (International Building Physics Toolbox) and Matlab/Simulink. Analysis on the thermal conditions and energy efficiency revealed that each control logic created comfortable conditions for their respective target, i.e., temperature, humidity, PMV or TS, but uncomfortable for others (e.g., temperature-based control logic maintained PMV or TS uncomfortably or vise versa). In addition, energy efficiency was significantly different by logics. In conclusion, it can be said that the overall thermal comfort can be improved by the adoption of the PMV and TS as a target variable and their economical benefits are expected in the hotter climate zones with the reduced cooling and dehumidifying energy consumptions.

Polyethylene Glycol 처리한 아크릴 운동용 양말의 축열 . 방열성과 수분전달 특성이 착용 성능에 미치는 영향 (The Effect of Thermal Storage/Release and Moisture Transport Properties of Polyethylene Glycol-Treated Acrylic Athletic Socks on the Wear Performance)

  • 조길수;이은주
    • 한국의류학회지
    • /
    • 제19권1호
    • /
    • pp.36-50
    • /
    • 1995
  • The purpose of this study was 1) to estimate the improvement of thermal storage/release and moisture transport properties of PEG-treated acrylic athletic socks and suggest the optimum add-on for PEG treatment, 2) to investigate wear performance of untreated cocks and two kinds of socks treated with PEG of minimum and optimum add-on respectively, and 3) to consider the effect of thermal storage/release and moisture transport properties of PEG- treated socks on the wear performance and the subjective comfort zone. Thermal activities of specimens treated by PDC were evaluated on a DSC by measuring the heat of fusion on heating and the heat of crystallization on cooling. Moisture regain, absorption speed, wickability, water retenti on value, and water-vapor permeability were measured. In the wear trials that the subjects performed a subsequent exercise protocol wearing three differently treated socks in a conditioned environment ($14\pm2^{\circ}C$, 65$\pm$2% R.H.), microclimate temperature and humidity, and subjective wear sensations including thermal sensation, wettedness, softness, fit, and overall comfort were obtained. PEC-treated specimens with more than 20% add-on showed thermal storage on heating and thermal release on cooling by a DSC and the heat contents of treated ones were generally proportional to the add-ons. Moisture transport properties were highly improved after PEG treatment and increased rapidly with increasing add-on. The tendencies were, however, relaxed above 50% add-on and the treated knits were much stiffer above that add-on. In the wear trials of untreated, PEG add-on 20%, and 50% acrylic socks, the changes of microclimate temperature of 50% socks were significantly less than that of 20% socks. PEG add-on 50% socks showed significantly less changes of microclimate humidity than other two kinds of socks. Three kinds of socks showed significant differences in overall comfort and add-on 50% socks were accepted more comfortable than other two kinds of socks. Comfort zone of foot was extended after PEG treatment on socks and it implied that the subjects wearing PEG- treated socks felt comfortable in wider ranges of microclimate temperature and humidity.

  • PDF

보강 흙벽의 열전도 특성 (Property of Thermal Conduction of Reinforced Soil Wall)

  • 장병욱;서동욱;박영곤
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.638-644
    • /
    • 1999
  • The objectives of the study are to investigate thermal conductivity(TC) and coefficient of thermal transmission (CTT) according to the type of soils, the presence of reinforceemnt, temperature, relative humidity and to analyze experimentally the characteristics of thermal transfer of reinforced soil wall. Results are summarized as follows ; 1) Clayey soil has high value of TC and CTT than sandy soil. 2) TC and CTT of reinforced soil wall is about 6∼17% higher than those of reinforced one, 3) It is founded that the effect of relative humidity on the soil wall is important at the same temperature and 4) As the temperature is high, it is appeared that TC and CTT are high.

  • PDF

황토벽돌벽 주택의 실내온열환경에 관한 연구 (A Study on the Indoor Thermal Environment of House Using Earth Brick Wall)

  • 이재윤
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

광학엔진 렌즈의 고장 메커니즘에 대한 고찰 (Overview of Failure Mechanisms on Lens for Optical Engine)

  • 차종범;김광섭
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제6권2호
    • /
    • pp.173-186
    • /
    • 2006
  • This paper presents a study on the failure mechanism for optical engine of Projection TV. The lenses of which optical engine composes are failed by various environmental conditions, that is, thermal effect, moisture effect, mechanical shock or chemical effect. By surveying on actual TV working condition, the major factor of failure was turned out the thermal effect. Because the actual surface temperature of optical engine rose at max. $51^{\circ}C$ during it worked, the relative humidity around optical engine was kept at less than 20% that is difficult to do chemical reaction with humidity. Therefore we can make a conclusion that the major failure of optical engine resulted from thermal effect.

  • PDF

하계 인공환경실험에서의 온열쾌적특성 (Characteristics of thermal comfort for artificial environment experiment in summer)

  • 박종일;김경훈;홍희기;민병일;김창주
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.368-377
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate(Electrocardiogram), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at SE $T^{*}$ 24.7$^{\circ}C$, -0.82<PMV<0.93, subject's clothing(0.41c1o)and the difference of skin temperature was found at the calf area as air temperature changes. At low SE $T^{*}$, heart rate was decreased and at high SE $T^{*}$, heart rate was increased but there was no change EEG(keeping $\alpha$-wave).wave).

  • PDF

도시 가로수의 증산 작용으로 인한 불쾌지수 변화 분석 (Analyzing Change of Discomfort Index for Transpiration of Street Tree)

  • 윤석환;이동근;박채연
    • 한국환경복원기술학회지
    • /
    • 제23권5호
    • /
    • pp.29-43
    • /
    • 2020
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. The cooling effect of street tree is regarded as a effective way to ameliorate the urban heat environment. The effect is largely made up of shadow formation and transpiration. This study aims to identify how the transpiration affects the discomfort index by analyzing comprehensive impact of the transpiration on the air temperature and relative humidity. The changes in the amount of transpiration, air temperature, and relative humidity were estimated for Seogyo-dong area which has a lot of floating population in Seoul, at 2 p.m. in dry day in July and August. On average, the transpiration of the street tree decreased the temperature 0.3℃ and increased the relative humidity 2.6% in an hour. As a result of these changes in temperature and humidity, the discomfort index rose mostly(0.036 on average). It was always get rise especially on the day when the discomfort index was above 80(0.05 on average). However, compared with the significant change in temperature and humidity, the variation of the discomfort index itself was very slight(up to 0.107). Therefore, the effect of transpiration by the street trees might not be effective in the planning to improve the thermal environment(especially on the day when the discomfort index is high). It is necessary to select the species of trees and planting location considering the cooling effect of shade formation synthetically.

비타민 E 소재의 인체생리반응 및 쾌적성 평가 (Evaluation of Thermal Physiological Responses and Comfort in Vitamin E Fabric)

  • 임순;정명희
    • 복식문화연구
    • /
    • 제13권3호
    • /
    • pp.406-413
    • /
    • 2005
  • This study performed the evaluation of skin temperature, heart rate, temperature and relative humidity of microclimate, and subjective sensation, such as thermal sensation, wet sensation and comfort sensation to estimate physiological responses of the human body and its comfortable feeling to the vitamin E fabric. Experiments were performed on the five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $30{\pm}\;1^{\circ}C$, $50{\pm}\;15\%$ and 0.2m/s, respectively. Two kinds of clothes were used for experiments: unfinished sports clothes, with the same form and the same size, of short-sleeved knit shirt and long trousers made with $100\%$ cotton, and finished sports clothes printed with the vitamin E solution of the level of $0.88\%$. Exercises of walking (about 105 steps/minute) with the exercise intensity of 2.5 were performed for 20 minutes using treadmill. In result, the study showed significant difference (p<0.01) in average skin temperature between unfinished and finished sport clothes, and represented higher value with having unfinished sport clothes in wear than with finished one. The study also showed significant difference (p<0.01) in heart rate only during the period of exercise, and represented higher value generally with unfinished sport clothes than with finished one. There were significant differences not only in temperature of microclimate (p<0.01) but also in humidity of microclimate (p<0.05) between two sport clothes. As for the evaluation of subjective sensation, the study showed significant difference (p<0.05) in thermal sensation between the two kinds of sport clothes, significant difference in wet sensation only during the period of exercise, and significant difference (p<0.05) in comfort sensation only during the period of recovery.

  • PDF