Comparisons of Thermal-moisture Properties in Combination of 3D spacer and Polyurethane(PU) Foam for Mold Brassiere Cups (몰드 브래지어 컵의 제작을 위한 3D 스페이서 패브릭과 폴리우레탄(PU) 폼 조합에 따른 열·수분 전달 특성 비교)

  • Lee, Hyun Young;Park, Huiju
    • Korean Journal of Human Ecology
    • /
    • v.24 no.2
    • /
    • pp.285-295
    • /
    • 2015
  • To identify optimized thermal properties of mold brassiere cup for improved thermal comfort during summer, we compared the thermal resistance and the water vapor permeability of Polyurethane (PU) foam, 3D spacer fabric and the two combined materials of the PU foam and the 3D spacer fabric. Four experimental mold brassieres were made of the materials for wearing test. Six women in their twenties evaluated the wearing sensation in the hot and humid environment. The changes in microclimate temperature and humidity while wearing test brassiere cups were measured. Results indicate that thermal resistance increased as more PU foam were combined, while the water vapor permeability was higher as the content of the 3D spacer fabric increased at thickness of 18mm and over. However, in the wear test, the PU foam brassiere was the most preferred in all ambient conditions due to its soft, flexible and smooth texture, despite its high thermal resistance and low water vapor permeability. This indicates that the textures of mold foams are more dominant properties than thermal properties for mold foams in determining the wear comfort of mold brassieres.

Evaluation of Indoor Thermal Comfort for Ceiling Type System Air-Conditioner with Various Discharge Angles (천장형 시스템 에어컨의 토출방향 변화에 따른 실내 열쾌적성 평가)

  • Lee, Jin-Hyung;Kim, You-Jae;Choi, Weon-Seok;Park, Sung-Kwan;Youn, Baek;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1180-1185
    • /
    • 2006
  • Modern people spend most of time at indoor space, such as office or classroom. Especially, occupants are exposed to the airtight indoor air quality (IAQ) for a long time, At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. There are several factors which are influenced thermal comfort, such as temperature, humidity, convection and air movement, etc. Also, the individual factor, such as age, gender, Physical constitution and habit, should be considered. The 4-way cassette type air conditioner is known to bring out better performance about thermal comfort than the traditional one. This study is performed on the higher ceiling environment than the common buildings or classrooms. Also, this study analyzed on the Indoor thermal comfort by diffusing direction of 4-way cassette air conditioner with various discharge angles, $45^{\circ},\;50^{\circ},\;55^{\circ}$ and $60^{\circ}$. Using a commercial code, FLUENT, three-dimensional transient air thermal flow fields are calculated with appropriate wall boundary conditions and standard $k-{\epsilon}$ turbulence model. Results of velocity and temperature distributions are graphically depicted with various discharge angles.

  • PDF

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • v.25 no.4
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

Thermal Properties and Water Sorption Behaviors of Epoxy and Bismaleimide Composites

  • Seo, Jong-Chul;Jang, Won-Bong;Han, Hak-Soo
    • Macromolecular Research
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2007
  • In this work, we prepared epoxy/BMI composites by using N,N'-bismaleimide-4,4'-diphenylmethane (BMI), epoxy resin (diglycidyl ether of bisphenol-A (DGEBA)), and 4,4'-diamino diphenyl methane (DDM). The thermal properties and water sorption behaviors of the epoxy and BMI composites were investigated. For the epoxy/BMI composites, the glass transition and decomposition temperatures both increased with increasing BMI addition, which indicates the effect of BMI addition on improved thermal stability. The water sorption behaviors were gravi-metrically measured as a function of humidity, temperature, and composition. The diffusion coefficient and water uptake decreased and the activation energy for water diffusion increased with increasing BMI content, indicating that the water sorption in epoxy resin, which causes reliability problems in electronic devices, can be diminished by BMI addition. The water sorption behaviors in the epoxy/BMI composites were interpreted in terms of their chemical and morphological structures.

Thermal environment evaluation of KBS open hall with mixing ventilation and downward displacement ventilation systems (혼합환기와 하향 압출환기시스템이 동반된 KBS공개홀의 온열환경 평가)

  • 권용일;권순석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.147-154
    • /
    • 1998
  • This study was carried out for evaluating the interior thermal environment in KBS Open hall with large ceiling height and large space. Ventilation systems of KBS Open hall have combined mixing ventilation and downward displacement ventilation system. Temperature and velocity was measured 130 locations with low level(0.1m), mid level(0.6m) and high level(1.1m). But relative humidity was measured at 15 locations. The subjective thermal sensation was made an inquiry of occupancy at the location measured physical elements.

  • PDF

Evaluation of Indoor Thermal Environment of Houses using for heating in winter (도시가스 사용 주택의 동절기 실내온열환경 평가)

  • Park, Seok-Bong;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.125-131
    • /
    • 2005
  • This study identified satisfaction with gas heating and indoor thermal environment, targeting houses using gases for heating. 1) Thermal environment is relatively satisfactory except that indoor humidity is low. 2) A question that indoor temperature has to be decreased for saving energy was given and about two thirds of the respondents answered that temperature has to be lowered. When they were asked how to save energy 57% answered that they put on more clothes and 27% answered that they lower indoor temperature If consistent promotion on energy saving is implementer it's believed that energy can be effectively saved. 3) People wear simple clothes when they stay indoor because they think it is comfortable. However, for energy saving. they gave to wear warm clothes though they stay indoor.

Decomposition of Odor Pollutant Acetaldehyde Using Mn Loaded Microporous Zeolites (Mn 담지 미세기공 제올라이트를 이용한 악취오염물질인 아세트알데히드의 분해반응)

  • Lee, Hyung Won;Lee, Heejin;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.57-60
    • /
    • 2020
  • An acetaldehyde, a representative food waste odor, was decomposed using a hybrid system comprised of a non-thermal plasma and catalyst at an ambient temperature under high humidity. A five wt.% Mn was impregnated on two differently structured microporous zeolites, namely Beta and ZSM-5, with a different molar ratio of SiO2/Al2O3. Under high humidity conditions, the acetaldehyde degradation was higher in zeolites with the high ratio of SiO2/Al2O3. Among studied catalysts, a five wt.% Mn/Beta (SiO2/Al2O3 = 300) showed the highest acetaldehyde removal activity owing to its high hydrophobicity and reducibility. During long term stability test using the same catalyst for 110 hours, the acetaldehyde removal activity was relatively well-maintained.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

A Study on Thermal Comfort Comparison between Tencel and Polyester Indoor Cothing

  • Chung, Sham-Ho;Yoo, Eun-Ok;Hwang, Soo-Kyung;Lee, Han-Seop
    • International Journal of Costume and Fashion
    • /
    • v.9 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • This study compared the thermal comfort of indoor clothing from Tencel material that is getting higher in demand due to being eco-friendly with superior wettability, with that from Polyester material that despite being most widely used for indoor clothing, rapidly discharges body sweat due to low wettability. The experiments were performed in the two manners, objective evaluation under the conditions of an artificial climate chamber and subjective evaluation of wearing the given clothes at home followed by filling in the questionnaire. Subjects were 8 healthy elderly women in their 60's who spend majority of their time at home rather than in social activities, and comparison was made on skin temperature and humidity inside clothing at exercise and relaxation states under early summer environment. Based on these results, wearing Tencel material clothing maintained cooler temperatures under warm environment rather than when wearing Polyester material clothing, thus enabling activities under more comfortable state. Regarding humidity inside clothing, parts with twofold clothing did not show difference between Tencel and Polyester, but the onefold arm showed lower when wearing Tencel. With this results, Tencel is regarded as more comfortable and nicer than Polyester.

A Study on Reliability Assessment of Ag-free Solder (무은 솔더의 신뢰성 평가에 관한 연구)

  • Kim, Jong-Min;Kim, Gi-Young;Kim, Kang-Dong;Kim, Seon-Jin;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.109-116
    • /
    • 2013
  • The solder is any of various fusible alloys, usually tin and lead, used to join metallic parts that provide the contact between the chip package and the printed circuit board. Solder plays an important role of electrical signals to communicate between the two components. In this study, two kinds of Ag-free solder as sample is made to conduct the thermal shock test and the high humidity temperature test. Low resistance is measured to estimate crack size of solder, using daisy chain. The low speed shear test is also performed to analyze strength of solder. The appropriate degradation model is estimated using the result data. Depending on the composition of solder, lifetime estimation is conducted by adopted degradation model. The lifetime estimated two kinds of Ag-free solder is compared with expected lifetime of Sn-Ag-Cu solder. The result is that both Ag-free composition are more reliable than Sn-Ag-Cu solder.