• 제목/요약/키워드: thermal humidity

검색결과 646건 처리시간 0.033초

대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태 (The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students)

  • 최윤정;김운학
    • 한국생활과학회지
    • /
    • 제19권4호
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.

Adsorption properties of MgO protective layer in AC PDP

  • Manakhov, Anton;Nikishin, Nikolay;Hur, Min;Heo, Eun--Gi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.384-387
    • /
    • 2008
  • We have studied the adsorption of contaminations on the MgO protective layer by Thermal Desorption Spectrometry (TDS). The result shows that the increase in exposure time, MgO thickness and humidity multiply the quantity of adsorbed contaminations. It is also found that the desorption activation energy and contamination quantity is decreased by the additional firing process of MgO layer under oxygen environment.

  • PDF

저상버스 탑승객의 온열 쾌적성에 관한 수치연구 (Numerical Study on Human Thermal Comfort in a Low Floor Bus)

  • 박원구;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.645-651
    • /
    • 2015
  • Numerical study on human thermal comfort in a low floor bus has been conducted. Human thermal comfort in a bus depends mainly on air temperature, air velocity, mean radiant temperature, humidity, and direct solar flux, as well as the level of activity and thermal properties of clothing. The paper presents the velocity and temperature distribution, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) indices for the driver and passengers.

소형아파트의 방위에 따른 실내온열환경 실태와 평가 (Thermal Environment of Small-size Apartments Facing in Two Different Directions)

  • 최윤정
    • 대한가정학회지
    • /
    • 제31권3호
    • /
    • pp.213-222
    • /
    • 1993
  • The purpose of this study was to investigate the present conditions of thermal environment in small-size apartments. The research methods used were measuring of environmental elements and personal self-administration for the residents' thermal comfort responses. The house subjected were 25 peung apartments facing southeast and southwest directions. The results of this study were summarized as follow ; The indoor temperature and humidity of houses subjected were 25.0∼27.3℃, 37.1∼42.5%. Compared with the distribution of indoor temperature and globe temperature of houses subjected, those of southeast house were more stable. And in the residents' thermal sensation responses, the residents of southeast houses checked more often neutral zone. Therefore the thermal environment of southeast houses were more comfortable condition than southwest houses.

  • PDF

샌드위치 패널의 열적 손상에 의한 부식 형상에 관한 연구 (A study on the shapes of thermal corrosion in sandwich panel)

  • 김현동
    • 한국화재조사학회지
    • /
    • 제3권1호
    • /
    • pp.43-46
    • /
    • 2003
  • In this experimental report, We introduce an idea of thermal corrosion in sandwich panel. In brief, Because the structures of sandwich panel are easily collapsed by thermal damage caused by a fire, it is very difficult to investigate a point and origin of fire. Therefore, If the shapes of thermal corrosion are reconstructed according to change of temperature and lapse time by experiment in sandwich panel, it is very simple task that fire scene investigators search for a point and origin of fire. As a result, we present the difference of thermal corrosion between samples which are applied heat by many-sided variable, such as temperature, heating time, lapse time, humidity, and others.

  • PDF

Nonlocal strain gradient model for thermal stability of FG nanoplates integrated with piezoelectric layers

  • Karami, Behrouz;Shahsavari, Davood
    • Smart Structures and Systems
    • /
    • 제23권3호
    • /
    • pp.215-225
    • /
    • 2019
  • In the present paper, the nonlocal strain gradient refined model is used to study the thermal stability of sandwich nanoplates integrated with piezoelectric layers for the first time. The influence of Kerr elastic foundation is also studied. The present model incorporates two small-scale coefficients to examine the size-dependent thermal stability response. Elastic properties of nanoplate made of functionally graded materials (FGMs) are supposed to vary through the thickness direction and are estimated employing a modified power-law rule in which the porosity with even type of distribution is approximated. The governing differential equations of embedded sandwich piezoelectric porous nanoplates under hygrothermal loading are derived through Hamilton's principle where the Galerkin method is applied to solve the stability problem of the nanoplates with simply-supported edges. It is indicated that the thermal stability characteristics of the porous nanoplates are obviously influenced by the porosity volume fraction and material variation, nonlocal parameter, strain gradient parameter, geometry of the nanoplate, external voltage, temperature and humidity variations, and elastic foundation parameters.

전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구 (An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province)

  • 이태강;최은석;김항;김형렬;기노갑;김선우
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.

공조기가 설치된 고분 내에서의 열 및 음 환경 평가 (Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System)

  • 박진양;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

도시근린공원의 열환경 개선을 위한 열쾌적성 평가 (An Evaluation of Thermal Comfort on Urban Neighborhood Park for Improving Thermal Environment)

  • 임은나;이우성;최철현;송봉근;정성관
    • 한국지리정보학회지
    • /
    • 제16권4호
    • /
    • pp.153-170
    • /
    • 2013
  • 본 연구는 도시 근린공원의 열쾌적성을 평가하고 이에 따른 열환경 개선방안을 도출하고자 연구를 진행하였다. 먼저 공원의 주요 열환경 인자의 분포특성 및 공간 유형별 차이를 평가한 결과, 기온, 상대습도, 풍속의 경우 공간적으로 뚜렷한 차이를 보이지 않았다. 그러나 평균복사온도는 공간의 개방정도 및 포장재질에 따라 큰 차이를 나타내는 것으로 확인되었다. 추출된 열환경 인자를 토대로 공간 유형에 따른 열쾌적성을 평가한 결과, 광장의 PMV(Predicted Mean Vote, 예상온열감) 지수가 4.39로 가장 높게 나타났으며, 동선의 경우 2.58, 녹지 1.90 그리고 휴게공간은 0.42로 평가되었다. 이러한 열쾌적성을 결정하는 열환경 요인에 대한 중요도를 평가해보기 위하여 PMV 회귀모형을 구축한 결과, 평균복사온도(1.084), 풍속(-0.280), 기온(0.013), 상대습도(-0.009)의 순으로 PMV에 대한 상대적인 중요도가 높게 나타났다. 열환경적 측면에서 개선이 필요한 지역을 대상으로 시나리오 분석을 실시한 결과, 반사율, 색상, 포장재질의 물리적 특성 변화를 통해 인체가 체감하는 열쾌적성을 향상시킬 수 있으며, 실제 공원에 이를 적용하여 개선안을 마련할 수 있을 것으로 판단된다.

파카의 보온성에 따른 착용감에 관한 연구 (The Effects of Parka on Subject Wear Sensation as to Thermal Resistance)

  • 이윤정;이순원
    • 한국의류학회지
    • /
    • 제13권3호
    • /
    • pp.295-303
    • /
    • 1989
  • This study is to measure the thermal resistance of 7 types of Parka of different materials with thermal manikin and to compare their effects on physiological responses & subjective wear sensations. Following are the results obtained from the experiments 1) From the thermal manikin experiment, i) As an outer layer, although not significant, water proof fabric was warmer than water proof-vapor permeable fabric. ii) In case of insulating material, down was better for thermal resistance than polyester wadding of the same thickness. Moreover, as the down was thicker, it had more efficiency in thermal resistance. However, the marginal efficiency of thickness was found to be decreasing. 2) From the male-subject experiments, i) Chest temperature, mean skin temperature & microclimate temperature showed the same results on thermal resistance as those of the thermal manikin experiment. ii) Only during rest periods, there was a significant difference among 5 insulating materials in the sense of microclimate humidity. The almost same conclusion was obtained from the above experiments. Even the outer layer did not significantly affect thermal resistance & subjective wear sensation, insulating materials had a significant influence upon them. But in case of 3.5 cm down, it gave less comfortable than that of the thinner. Therefore the optional one for the best comfort & thermal resistance among 7 combinatins is the outer layer of water proff-vapor permeable & insulating material of 2.1 cm down.

  • PDF