• 제목/요약/키워드: thermal history

검색결과 284건 처리시간 0.042초

숭례문 기와의 물리적 특성 연구 (A Study of the Physical Properties of Sungnyemun Tile)

  • 정광용
    • 건축역사연구
    • /
    • 제20권1호
    • /
    • pp.23-39
    • /
    • 2011
  • The Sungnyemun roofing tiles were twice disassembled for maintenance work, in 1963 and 1997, and modern tiles were applied in 1997. However, besides differing in visual appearance, the modern tiles had distinctly different physical properties. A study has been carried out on 22 different tiles, including original Sungnyemun tiles, modern tiles applied during maintenance, traditional tiles made by tile-makers, and others, to examine their physical properties, such as bending strength, frost resistance, absorption, whole-rock magnetic susceptibility, chromaticity, differential thermal analysis, and other characteristics. Since the method of making modern tiles involves compressing clay in a vacuum, modern tiles showed relatively greater bending strength and specific gravity, while Sungnyemun tiles and those made by tile-makers, in comparison, demonstrated less bending strength and specific gravity owing to their production method of 'treading,' in which clay is mixed by having someone tread upon it repeatedly. Over time, the absorption rate of the original tile used for Sungyemun gradually decreased from 21% to 14.7%; traditional tiles from tile-makers showed absorption rates of 17%, while the absorption rate of modern tiles was just 1%, which is significantly low. As for frost resistance, Sungnyemun tiles and traditional tiles from tile-makers showed cracking and exfoliation after being subjected to testing 4 or 5 times, while slight cracking was seen on the surface for modern tiles after 1ngy, or 3 times. In other words, no significant difference from influence by frost was found. According to the results of differential thermal analysis, the plastic temperature was shown to have been no less than 1, $on^{\circ}C$ for all types of tile, and cristobalite was measuredthrough XRD analysis from a Sungnyemun female tile applied during maintenance in 1963, which appeared to have been plasticized at between $1,200^{\circ}C{\sim}1,300^{\circ}C$. Based on these research results on the physical properties of tiles from the Sungnyemun roof, a fundamental production method for tiles to be applied in the restoration of Sungnyemun has been identified.

슈퍼 듀플렉스 다층용접부의 미세조직 및 공식(Pitting Corrosion)에 미치는 용접열사이클의 영향 (Effect of Welding Thermal Cycle on Microstructure and Pitting Corrosion Property of Multi-pass Weldment of Super-duplex Stainless Steel)

  • 남성길;박세진;나혜성;강정윤
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.37-37
    • /
    • 2009
  • Due to their high corrosion resistance and improved mechanical properties super-duplex stainless steel (SDSS) are extensively used in petrochemical plants such as facilities in modern oil platform and off-shore process equipment. It is well known that the best mechanical and corrosion resistance properties of super-duplex stainless steel are obtained with a microstructure having approximately equal amounts of austenite and ferrite. And it is also known that sigma($\sigma$), chi($\chi$), secondary austenite(${\gamma}2$), chromium carbides and nitride affected adversely their properties. Therefore these phases must be avoided. However, effects of succeeding weld thermal cycle on the change of microstructure of weldment at multi-pass weld were not seldom experimentally researched. Therefore in the present work, the change of weldmetal microstructure and the effect of microstructure on pitting corrosion property at $40^{\circ}C$ by succeeding each weld thermal cycle were researched. The thermal history of root side was measured experimentally and the change of microstructure of root weld according to thermal cycle of each weld layer was evaluated. And the relationship between microstructure of root weld and pitting corrosion property at $40^{\circ}C$ was also investigated. Results of the present work are show as below. 1. The ferrite contents of root weld are gradually reduced by succeeding weld thermal cycle. 2. The 2nd phases such as sigma($\sigma$), chi($\chi$), secondary austenite(${\gamma}2$), chromium carbides and nitride are increased gradually by succeeding weld thermal cycle. 3. The pitting corrosion was detected in root weld part and weight loss by pitting corrosion is increased in proportional to the time exposed over $600^{\circ}C$ of the root weld. 4. The succeeding weld thermal cycles affect the microstructure of the former weldments and promote the formation of 2nd phases. That is, the more succeeding welds are added, the more 2nd phases are gradually increased. Consequently, it is thougth that this adversely affects pitting corrosion property.

  • PDF

크리이프를 고려한 매스콘크리트의 수화열에 대한 온도응력 해석 (Thermal Stress Analysis of the Heat Generation for Mass Concrete Considering Creep Effect)

  • 김진근;이종대
    • 대한토목학회논문집
    • /
    • 제14권4호
    • /
    • pp.771-781
    • /
    • 1994
  • 매스콘크리트에서 시멘트의 수화반응에 의해 발생되는 열은 약재령 콘크리트(young concrete)에서 내부온도의 증가와 체적변화를 초래하므로 외적인 구속이 존재하면 구조물에는 인장응력이 발생하고 이는 구조물에 균열을 일으킬 수 있다. 따라서 매스콘크리트의 설계와 시공단계에서 균열을 제어하기 위해서는 온도응력을 정확하게 예측하는 것이 매우 중요하다. 또한 약재령 콘크리트에서는 크리이프 효과가 노재령 콘크리트(old concrete)의 경우에 비하여 현저하게 크므로 이를 반드시 고려하여야 할 것이다. 이 논문은 매스콘크리트에서의 온도에 관한 시간이력을 구하고 크리이프와 각 요소의 온도를 고려한 탄성계수를 적용하여 온도응력을 구하는 유한요소 프로그램을 개발하는데 그 목적이 있다. 개발된 프로그램의 해석결과를 문헌의 자료들과 비교해 볼 때 온도균열의 제어에 가장 중요한 내부에서의 온도이력과 응력이 실험결과와 잘 부합되고 있다. 따라서, 이 논문의 해석방법은 매스콘크리트 구조물의 설계와 시공단계에서 균열의 제어를 위해 유용하게 사용될 수 있을 것이다.

  • PDF

TV 유리의 반복 성형공정에서 3차원 금형 열사이클 해석 (Three Dimensional Thermal Cycle Analysis of Mold in Repeated Forming Process of TV Glass)

  • 황정해;최주호;김준범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.192-198
    • /
    • 2000
  • Three dimensional thermal cycle analysis of the plunger is carried out in repeated forming process of the TV glass, which is continued work of two dimensional analysis where an efficient method has been proposed. The plunger undergoes temperature fluctuation during a cycle due to the repeated contact and separation from the glass, which attains a cyclic steady state having same temperature history at every cycle. Straightforward analysis of this problem brings about more than 90 cycles to get reasonable solution. An exponential function fitting method is proposed, which finds exponential function to best approximate temperature values of 3 consecutive cycles, and new cycle is restarted with the fitted value at infinite time. Number of cases are analyzed using the proposed method and compared to the result of straightforward repetition, from which one finds that the method always reaches nearly convergent solution within $9{\sim}12$ cycles, but turns around afterwards without further convergence. Two step use is found most efficient, in which the exponential fitting is carried out fer the first 12 cycles, followed by simple repetition, which shows fast convergence expending only 6 additional cycles to get the accuracy within 2 error. This reduces the computation cycle remarkably from 90 to 18, which is 80% reduction. From the parametric studies, one reveals that the overall thermal behavior of the plunger in terms of cooling parameters and time is similar to that of 2 dimensional analysis.

  • PDF

개에서 제3안검 제거 후 전기소작법을 이용한 누점폐쇄 효과 (The Effect of Punctal Occlusion with Thermal Cautery after Third Eyelid Resection in Dogs)

  • 최장윤;박현정;이주명
    • 한국임상수의학회지
    • /
    • 제23권1호
    • /
    • pp.50-54
    • /
    • 2006
  • To evaluate the effect of punctal occlusion on tear preservation after third eyelid resection, 10 eyes were operated in dogs and observed changes in tear preservation using Schirmer tear test (STT). Punctal occlusion was performed on five healthy dogs with no clinical sings of ocular irritation and no history of dry eye syndrome. The STT was performed for 10 days before surgery, and on the day 0, 1, 3, 5, 7, 9, 11, 13, 17, 21, 25, and 30 after third eyelid resection. The mean STT was $17.4{\pm}0.15$ mm/min($mean{\pm}SEM$) for 10 days before surgery. And, it was $11.5{\pm}0.55$mm/min for 30 days after surgery in puntal occlusion(PO) group. The mean STT was $17.3{\pm}0.32$ mm/min for 10 days before surgery. And, it was more decreased to $6.5{\pm}0.60$ mm/min for 30 days after surgery in control group. The paired t-test was performed. Mean STT after the third eyelid resection was higher in PO group than that of control throughout experimental period (p<0.05). In summary, the effect of thermal punctal occlusion significantly increased on the tear preservation by $28.86{\pm}7.96%$. These results suggest that application of thermal punctal occulsion in dry eye syndrome will promote tear preservation.

남한의 옥천습곡대에 분포되어 있는 제천화강암체의 열역사 (Thermal history of the Jecheon granite pluton in the Ogcheon Fold Belt, South Korea)

  • 진명식;김성재;신성천;주승환;지세정
    • 암석학회지
    • /
    • 제1권1호
    • /
    • pp.49-57
    • /
    • 1992
  • 제천습곡대의 제천화강암에 대하여 Rb-Sr, K-Ar 그러고 휫션트랙 등 세 가지 방법으로 다음과 같은 열역사를 규명하였다. 3개의 전암시료와 7개의 광물시료의 Rb과 Sr의 동위원소를 측정하여 얻은 등시선연령은 202.7$\pm$1.9Ma이고, Sr 초생치는 0.7140였다. 12개의 광물시료를 K-Ar 및 휫션트랙법으로 연령측정한 결과 각각의 연령보존온도에 거의 상응하는 광물연령을 얻었다. 연령측정자료로 이 암석의 성인과 암체의 열역사를 해석한 결과는 다음과 같다. 제천화강암은 쥬라기초(약 203 Ma)에 지각물질이 부분용융을 받아서 만들어진 'S-형'의 마그마가, 또는 맨틀기원의 'I-型'마그마와 지각물질의 심한 혼화작용에 의해 만들어진 마그마가 지각 심부 (mesozone 또는 katazone; 약 7~9km)에 관입하였으며, 관입체와 주변암석괴의 온도차 때문에 30$0^{\circ}C$까지는 매우 빨리 냉각되었다. 쥬라기말까지는 주위 암석들과 열적인 평형을 유지하므로써 냉각이 거의 중지되었다가, 백악기초부터 말까지 (140~70 Ma)는 화성활동을 수반한 심한 지구조운동과 활발한 풍화작용 때문에 평균 약 40~60 m/Ma의 상승률과 약 1.4$^{\circ}C$/Ma의 냉각률로 3~7 km 상승하였다. 백악기말부터 삼기초(70~50 Ma)까지는 펀균 약 100~120m/Ma의 상승률과 5$^{\circ}C$/Ma의 냉각률을, 그리고 삼기초 (50 Ma)부터 현재까지는 평균 약 50~60m/Ma의 상승률과 2$^{\circ}C$/Ma의 냉각률을 가지고 각각 상승 및 냉각된 것으로 해석된다.

  • PDF

적외선체열촬영을 통한 편측 경항상지통환자의 임상적 고찰 (Analysis about DITI of the Patients having a Neck and Upper Extremity Pain on One Side)

  • 박민정;이경윤;조원영;박쾌환
    • Journal of Acupuncture Research
    • /
    • 제21권2호
    • /
    • pp.301-314
    • /
    • 2004
  • Objectives : We studied to discover the patterns of DITI of the patients having a both neck and upper extremity pain on one side without any nerve root compression sign and the history of cervical disc herniation. Method : We selected 26 patients as an experimental group, who had visited for a both neck and upper extremity pain on one side without any nerve root compression sign, at the department of acupunture and moxibustion in Conmaul oriental medical hospital, during 2001. 01. - 2003. 09. And 31 normal adults were selected as a control group, not having any neck or arm pain and any history of cervical disease. We analyzed the segmental temperature statistically with t-test. Results & Conclusion : There was a significant change of temperatures in the scapula, posterior brachium, lateral forearm and dorsal hand area. And the experimental group showed cold spot and disruption of normal thermographic shape that were usually shown on the cervical sprain.

  • PDF

적외선체열촬영을 통한 편측 경항상지통환자의 임상적 고찰 (Analysis about DITI of the Patients having a Neck and Upper Extremity Pain on One Side)

  • 이경윤;조원영;박쾌환;박민정
    • 대한한방체열의학회지
    • /
    • 제4권1호
    • /
    • pp.61-69
    • /
    • 2005
  • Objectives : We studied to discover the patterns of DITI of the patients having a both neck and upper extremity pain on one side without any nerve root compression sign and the history of cervical disc herniation. Method : We selected 26 patients as an experimental group, who had visited for a both neck and upper extremity pain on one side without any nerve root compression sign, at the department of acupunture and moxibustion in Conmaul oriental medical hospital, during 2001. 01. - 2003. 09. And 31 normal adults were selected as a control group, not having any neck or arm pain and any history of cervical disease. We analyzed the segmental temperature statistically with t-test. Results & Conclusion : There was a significant change of temperatures in the scapula, posterior brachium, lateral forearm and dorsal hand area. And the experimental group showed cold spot and disruption of normal thermographic shape that were usually shown on the cervical sprain.

  • PDF

수화열 해석 프로그램에 의한 저발열 콘크리트의 특성에 미치는 부재두께 및 양생온도의 영향에 관한 연구 (A Study on Effect of Specimen Thickness and Curing Temperature on Properties of Low Heat Concrete by Analysis Program for Heat of Hydration)

  • 이승민;노형남;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.31-36
    • /
    • 2008
  • This study aims to examine the effects of thickness of the concrete members and curing temperature on the properties of low heat concrete through heat of hydration analysis. Type of the members that was analyzed in the experiment is ternary mixture of ordinary portland cement, blast-furnace slag incorporating ratio(20%) and fly ash incorporating ratio(30%), which formed a mat foundation. Thicknesses of the concrete members were 1, 2 and 3(m) and three levels of curing temperatures were 10, 20 and 30(℃). They were applied to analyze the effects on the temperature and thermal cracking index. As a result, for temperature history, temperature difference between the central area and the surface tended to decrease as the thickness of the concrete members get thinner. For the temperature cracking index, on the other hand, the risk of cracking tended to decrease as the curing temperature gets higher and as the thickness gets thinner.

  • PDF

VERIFICATION OF COSMOS CODE USING IN-PILE DATA OF RE-INSTRUMENTED MOX FUELS

  • Lee, Byung-Ho;Koo, Yang-Hyun;Cheon, Jin-Sik;Oh, Je-Yong;Joo, Hyung-Kook;Sohn, Dong-Seong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2002년도 춘계공동학술발표회요약집
    • /
    • pp.242-242
    • /
    • 2002
  • Two MIMAS MaX fuel rods base-irradiated in a commercial PWR have been reinstrumented and irradiated at a test reactor. The fabrication data for two MOX roda are characterized together with base irradiation information. Both Rods were reinstrumented to be fitted with thermocouple to measure centerline temperature of fuel. One rod was equipped with pressure transducer for rod internal pressure whereas the other with cladding elongation detector. The post irradiation examinations for various items were performed to determine fuel and cladding in-pile behavior after base irradiation. By using well characterized fabrication and re-instrumentation data and power history, the fuel performance code, COSMOS, is verified with measured in-pile and PIE information. The COMaS code shows good agreement for the cladding oxidation and creep, and fission gas release when compared with PIE dad a after base irradiaton. Based on the re-instrumention information and power history measured in-pile, the COSMOS predicts re-instrumented in-pile thermal behaviour during power up-ramp and steady operation with acceptable accuracy. The rod internal pressure is also well simulated by COSMOS code. Therfore, with all the other verification by COSMOS code up to now, it can be concluded that COSMOS fuel performance code is applicable for the design and license for MaX fuel rods up to high burnup.

  • PDF