• Title/Summary/Keyword: thermal factor

Search Result 1,559, Processing Time 0.035 seconds

A Study on Structural Safety Evaluation of let Vane under very High Temperature and Dynamic Pressure (초고온 동압을 밭는 제트 베인의 구조 안전성 평가에 대한 연구)

  • Park Sunghan;Lee Sangyeon;Park Jongkyoo;Kim Wonhoon;Moon Soonil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.3
    • /
    • pp.18-24
    • /
    • 2005
  • To evaluate structural safety factor of the jet vane for the thrust deflection system under the dynamic pressure and very high temperature(2700$^{\circ}C$ ) of the combustion gas flow, the high temperature tension tests of refractory metals and 3-D nonlinear numerical simulations are performed. Through the analysis of high temperature structure behavior for jet vane, the structure safety of jet vane is evaluated, and numerical results are compared with static ground tests of jet vanes. It has been found that most of structural and thermal loading is concentrated on the vane shaft which worked as safe under 1400$^{\circ}C$. From the comparison of static ground tests and numerical results, the evaluation criterion using the vane load and shaft displacement is more useful to estimate the structural safety than using the equivalent stress.

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF

Viscoelastic and Acoustic Characterization of Coatings for Stringed Instruments (현악기용 음향기능성 도료의 점탄성적 성질과 음향적 성질)

  • Choi, Jae-Hoon;Lee, Byoung-Hoo;Kim, Hyun-Joong;Chung, Woo-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.4 s.132
    • /
    • pp.15-22
    • /
    • 2005
  • The acoustic properties of various coatings for stringed musical instruments made were investigated. The applied coatings were urethane topcoat, oil stain, natural varnish, cashew and UV-curable epoxy coating. Acoustic properties of coatings inferred from a resonance frequency and a damping measured by FFT analyzer and tan ${\delta}$ measured by DMTA. Acoustic properties from resonance frequency and damping were analyzed. Optimum coating for stringed instruments was determined by viscoelastic properties and acoustic properties of coating.

Reliability assessment of mica high voltage capacitor through environmental test and accelerated life test (마이카 고전압 커패시터의 환경시험과 가속 수명시험을 통한 신뢰성 평가)

  • Park, Seong Hwan;Ham, Young Jae;Kim, Jeong Seok;Kim, Kyoung Hun;So, Seong Min;Jeon, Min Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.270-275
    • /
    • 2019
  • Mica capacitor is being adopted for high voltage firing unit of guided weapon system because of its superior impact enduring property relative to ceramic capacitor. Reliability of localized mica high voltage capacitors was verified through environmental test like terminal strength test, humidity test, thermal shock test and accelerated life test for application to high voltage firing unit. Failure mode of mica capacitor is a decrease of insulation resistance and its final dielectric breakdown. Main constants of accelerated life model were derived experimentally and voltage constant and activation energy were 5.28 and 0.805 eV respectively. Lifetime of mica capacitor at normal use condition was calculated to be 38.5 years by acceleration factor, 496, and lifetime at accelerated condition and this long lifetime confirmed that mica high voltage capacitor could be applied for firing unit.

VOC Emission Characteristics of Dry Cleaned Wool Scarfs through Small Chamber Test (소형챔버를 이용한 드라이클리닝 모직물 목도리의 휘발성유기화합물 방출 특성)

  • Shin, Jin-ho;Kwon, Seung-mi;Kim, Hyun-soo;Roh, Bang-Sik;Kim, Kwang-rae;Eo, Soo-mi;Jung, Kweon;Lee, Young-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.95-102
    • /
    • 2017
  • Objectives: This study was conducted to evaluate the emission of VOCs from clothing that had been dry cleaned. Methods: In order to ensure the same conditions, f100% wool scarves were selected as the fabric type. Four identical tests were conducted on the option of either removing the plastic bags which came from the dry cleaning shop or not. The scarf was located inside a closet or room for one or two days. Small chamber tests were conducted to determine the VOC emission characteristics under the same conditions such as temperature, humidity, loading factor, and air exchange rates. Air from the chamber for VOCs was sampled by Tenax TA tube and analyzed by thermal desorption and GC/MSD. Results: Assuming that test represented dry cleaning and consumer's conditions well enough, we can conclude that immediate emissions after the dry cleaning of the scarfs caused elevated levels of TVOC, five VOCs (benzene, toluene, ethylbenzene, xylene, stylene), and decane group compounds. Conclusions: By removing the plastic bags which came from the dry cleaning shop or not, the storage conditions of dry cleaned scarfs by consumers during the storage time periods (one to three days) would be significant for reducing VOC emissions.

Solubillzation and Extraction Of Antioxidant Astaxanthin by Micelle Formation from Phaffia rhodozyma Cell Homogenate (Phaffia rhodozyma 세포파쇄액으로부터 항산화제 Astaxanthin의 미셀 형성을 통한 가용화 및 추출)

  • Kim, Young-Beom;Ryu, Kang;Lim, Gio-Bin;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.17 no.2
    • /
    • pp.176-181
    • /
    • 2002
  • Astaxanthin (3,3'-dihydroxy-${\beta}$, ${\beta}$-carotene-4-4'-dione), a natural pigment of pink to red color, is widely distributed in nature particularly in the skin layer of salmonoids and the crust of shrimp, lobster, etc. Recently, it was produced from the yeast culture of Phaffia rhodozyma. Because of its high thermal stability and antioxidant functionality, its applications can be extended into food, cosmetics, and pharmaceutical ingredient beyond the traditional feed additive. Because of its very high lipophilicity, astaxanthin has been extracted traditionally by strong organic solvents such as chloroform, petroleum ether, acetone, etc. In this study, we developed a surfactant-based solubillization system for astaxanthin, and used it to extract astaxanthin from disrupted yeast cells. Among Tween 20, Triton X-100 and SDS, Tween 20 was identified as the most suitable surfactant in terms of extraction capacity and safety. The ethylene oxide group of Tween 20 was identified as the most significant factor to increase the HLB value that determined the extraction capacity. The effects of micelle formation condition, such as the molar ratio of astaxanthin and Tween 20, pH, and ionic strength were also investigated. pH and ionic strength showed no significant effects. The optimal molar ratio between astaxanthin and Tween 20 was 1 : 12. Antioxidant activity of astaxanthin was higher than ${\beta}$-carotene and ${\alpha}$-tocopherol. Astaxanthin in the crude extract from the yeast cell was more resistant to air and/or light degradation than pure astaxanthin, probably because of the presence of other carotenoids and lipids.

Structure of laser ablated $Ba_{0.8}Sr_{0.2}TiO_3$ thin films grown on MgO (레이저 증착법으로 MgO 기판에 성장한 $Ba_{0.8}Sr_{0.2}TiO_3$ 박막의 구조 연구)

  • Kim, Won-Jeong;Kim, Sang-Su;Hahn, Chang-Hee;Song, Tae-Kwon;Moon, Seung-Eon;Kwak, Min-Hwan;Kim, Young-Tae;Ryu, Han-Cheol;Lee, Su-Jae;Kang, Kwang-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.157-160
    • /
    • 2004
  • Ferroelectric $(Ba_xSr_{1-x})TiO_3$ (BST) thin films have been deposited on (001) MgO single crystals by a pulsed laser deposition (PLD) method. The structure of deposited BST thin films were investigated by an x-ray diffractometer. Calculated c-axis lattice parameters of the BST films exhibit a strong lattice distortion, which was not observed in ceramic BST at room temperature. This lattice distortion of BST has been attributed to strains caused by lattice constant difference between film and substrate, oxygen vacancies in BST film, and thermal expansion difference between film and substrate. Ferroelectric properties at 10 GHz have been measured using a HP 8510C vector network analyzer. Dielectric properties, capacitance tunability and quality factor, of the interdigitaed capacitors fabricated on BST films were calculated from the measured s-parameters. Two distinct behaviors in structural, opitical, and microwave properties of BST films were observed; below and above 200 mTorr of oxygen pressure in the deposition chmber.

  • PDF

Optimization of Subcritical Water Hydrolysis of Rutin into Isoquercetin and Quercetin

  • Kim, Dong-Shin;Lim, Sang-Bin
    • Preventive Nutrition and Food Science
    • /
    • v.22 no.2
    • /
    • pp.131-137
    • /
    • 2017
  • Maximum production of isoquercetin and quercetin simultaneously from rutin by subcritical water hydrolysis (SWH) was optimized using the response surface methodology. Hydrolysis parameters such as temperature, time, and $CO_2$ pressure were selected as independent variables, and isoquercetin and quercetin yields were selected as dependent variables. The regression models of the yield of isoquercetin and quercetin were valid due to the high F-value and low P-value. Furthermore, the high regression coefficient indicated that the polynomial model equation provides a good approximation of experimental results. In maximum production of isoquercetin from rutin, the hydrolysis temperature was the major factor, and the temperature or time can be lower if the $CO_2$ pressure was increased high enough, thereby preventing the degradation of isoquercetin into quercetin. The yield of quercetin was considerably influenced by temperature instead of time and $CO_2$ pressure. The optimal condition for maximum production of isoquercetin and quercetin simultaneously was temperature of $171.4^{\circ}C$, time of 10.0 min, and $CO_2$ pressure of 11.0 MPa, where the predicted maximum yields of isoquercetin and quercetin were 13.7% and 53.3%, respectively. Hydrolysis temperature, time, and $CO_2$ pressure for maximum production of isoquercetin were lower than those of quercetin. Thermal degradation products such as protocatechuic acid and 2,5-dihydroxyacetophenone were observed due to pyrolysis at high temperature. It was concluded that rutin can be easily converted into isoquercetin and quercetin by SWH under $CO_2$ pressure, and this result can be applied for SWH of rutin-rich foodstuffs.

Establishment of Fatigue Life Evaluation and Management System for District Beating Pipes Considering Operating Temperature Transition Data (운전이력을 고려한 지역난방 열배관의 피로수명 평가 및 관리 체계 구축)

  • Chang Yoon-Suk;Jung Sung-Wook;Kim Hyeong-Keun;Choi Jae-Boong;Kim Sang-Ho;Kim Youn-Hong;Kim Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.9 s.240
    • /
    • pp.1235-1242
    • /
    • 2005
  • A district heating(DH) system supplies environmentally-friend heat and is appropriate for reduction of energy consumption and/or air pollutions. The DH transmission pipe, composed of supply and return pipes, has been used to transmit the heat and prevent heat loss during transportation. The two types of pipes are operated at a temperature of $75\~115^{\circ}C\;and\;40\~65^{\circ}C$, respectively, with an operating pressure of less than 1.568MPa. The objectives of this paper are to systematize data processing of transition temperature and investigate its effects on fatigue life of DH pipes. For the sake of this, about 5 millions temperature data were measured during one year at ten locations, and then available fatigue lift estimation schemes were examined and applied to quantify the specific thermal fatigue life of each pipe. As a result, a relational database management system as well as reliable fatigue lift evaluation procedures is established for Korean DH pipes. Also, since the prototypal evaluation results satisfied both cycle-based and stress-based fatigue criteria, those can be used as useful information in the future fer optimal design, operation and energy saving via setting of efficient condition and stabilization of water temperature.

NOx Formation and Emission Characteristics of Premixed Swirl Flame of Natural Gas (천연가스 선회 예혼합 화염의 NOx 생성 및 배출 특성)

  • You, Hyun-Seok;Lee, Joong-Seong;Han, Jeong-Ok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.788-794
    • /
    • 1999
  • The swirl flame is mostly used to stabilize the flame on the burner nozzle in the industrial combustor. In the case of the weak swirl flame(S<0.4), the recirculation zone could not be formed, but in the strong swirl(S>0.6) flame, it could be formed in the center of the swirl flame. In this study, the measurement and analysis of emission species, temperature, radicals of premixed swirl flame in the combustor were performed to understand the NO formation and emission characteristics of the swirl flame of natural gas. The result of NO emission in the swirl flame is that the amount of NO emission in the strong swirl flame decreased about 60% compared with that of the weak swirl flame. The main region of NO formation of the weak swirl flame is positioned in the down stream(z=100~200mm) of the flame, but that of the strong swirl flame is positioned in the up stream(z=40mm) where the recirculation zone seems to be formed. It is supposed that the increase of flame surface and the formation of inversed flame cause the reduction of the high temperature region on the production of NO in the strong swirl flame. The result of NO-temperature relation revealed that the factor of NO formation is not only temperature but also another parameters in the weak swirl flame, but in the strong swirl flame, NO is proportional to the temperature of higher than 1200K.