• Title/Summary/Keyword: thermal extraction

Search Result 264, Processing Time 0.028 seconds

Development of Precise Measuring System for Hot Strip Mill's Rolls (열간압연용 롤 정밀 측정시스템 개발)

  • 이성진;이영진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.614-618
    • /
    • 2002
  • In hot strip mills, Portable Roll Scanner (the portable roll surface temperature and profile measuring device) can be used to calibrate on-line Process models for strip crown and flatness by measuring the thermal expansion and wear profile of the rolls. And the surface temperature measurement can be used to optimize the roll cooling system. Portable Roll Scanner consists of the measuring device, which has two contact inductive distance transducers for roll profile measurement and one infrared Pyrometer for surface temperature measurement, and computer-based controller that is equipped with the measuring device. By the wireless data communication, the data is transferred to the memory of notebook for further analysis. After roll extraction from mills, Portable Roll Scanner measure the roll profile and surface temperature simultaneously along the work roll face and display the results in the TFT color monitor of notebook. Portable Roll Scanner is useful at mill-side and roll grinding shop.

  • PDF

Development of Composite Bipolar Plate for PEMFC (고분자 전해질 연료전지용 복합수지 분리판 개발)

  • Kang, Hyun-Min;Han, In-Su;Lim, Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.3-7
    • /
    • 2007
  • Graphite/polymer composite bipolar plates for PEMFC are successfully developed, and their typical properties are superior to commercially available ones. Thermal property of the developed bipolar plate was evaluated by dynamic mechanical analyzer, and the results were compared to commercial ones. The specimens were immersed into the deionized water bath at $80^{\circ}$... for 1500hrs to evaluate dimensional stability and durability. Dimension, weight of the specimens as well as extraction conductivity was measured as each 500hrs. Fully molded bipolar plates without any machining or milling were also prepared using a specially developed mold, and they were applied to the fuel cell performance test. Results were compared to the machined commercial bipolar plate.

  • PDF

Phase-extraction using Zero-Crossing detection in fiber-optic laser interferometry (영점검출을 이용한 광섬유형 레이저 간섭계의 위상추출)

  • Park, Hyoung-Jun;Lee, Jun-Ho;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.426-430
    • /
    • 2005
  • The fiber-optic interferometer which is a powerful application for nondestructive measurement techniques has many advantages such as capability of making portable system, easy optical arrangement, low optical loss. In spite of these advantages, this system has an environmental sensitivity of thermal drifts and vibrations. Against environmental perturbations and nonlinear characteristic of phase modulator, the accurate and fast ${\pi}/2$ phase stepping has been achieved by using zero-crossing detection. CCD camera trigger signal is generated at the 4 zero-crossing points. Our System has achieved up to 100 Hz of image capture speed and 0.6 mrad of accuracy of phase stepping, accuracy.

  • PDF

Recovery of Petroleum Hydrocarbons from Oily Sludge Landfilled Soil

  • Shin, Su-Yeon;Park, Sang-Min;Ko, Sung-Hwan;Jung, Hong-Bae;Baek, Kitae
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.5
    • /
    • pp.41-46
    • /
    • 2015
  • Three types of experiments, based on the physical properties of oily sludge landfilled soil, were conducted to recover total petroleum hydrocarbons (TPH) from the soil. These experiments included gravity separation, solvent extraction using water, and air floatation. The oil portion was not easily separated from the wet (raw) soil because water molecules aggregate the soil particles, despite the fact that the soil was sandy. However, the drying and grinding processes destroyed the aggregates, causing the TPH recovery to increase to approximately 60% when air floatation was used. The drying process decreased the specific gravity of the soil sample, thereby enhancing the overall recovery of TPH from the soil. Although thermal desorption and/or incineration are common choices for heavily dumped sites, physical separation can recover the oil portion instead of simply removing it.

Implementation of LED BLU Using Metal core PCB with Anodizing Oxide Layer and Reflection Cup Structure (에노다이징 절연층과 반사컵 구조를 보유한 COB타입 LED BLU 광원구현)

  • Cho, Jae-Hyun;Lee, Min-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.8-13
    • /
    • 2009
  • LED BLU(Back Light Unit), based on MCPCB(Metal Core Printed Circuit Board) with anodizing oxide dielectric layer and improved thermal dissipation property, are presented. Reflecting cups were also formed on the surface of the MCPCB such that optical coupling between neighboring chips were minimized for improving the photon extraction efficiency. LED chips were directly attached on the MCPCB by using the COB (Chip On Board) scheme.

Characteristics of Electron Beam Extraction in Large Area Electron Beam Generator

  • Woo, Sung-Hun;Lee, Hong-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.1
    • /
    • pp.10-14
    • /
    • 2004
  • A large area electron beam generator has been developed for industrial applications, for example, waste water cleaning, flue gas treatment, and food pasteurization. The operational principle is based on the emission of secondary electrons from the cathode when ions in the plasma contact the cathode, which are accelerated toward the exit window by the gradient of the electric potential. Conventional electron beam generators require an electron beam scanning mechanism because a small area thermal electron emitter is used. The electron beam of the large area electron beam generator does not need to be scanned over target material because the beam area is considerable. We have fabricated a large area electron beam generator with peak energy of 200keV, and a beam diameter of 200mm. The electron beam current has been investigated as a function of accelerating voltage and distance from the extracting window while its radial distribution in front of the extracting window has been also measured.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube

  • Hong Hiki;Kang Chaedong;Peck Jong Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.206-213
    • /
    • 2004
  • Cycle test for developed phase change material (PCM) is necessary in order to assess the variation of latent heat, which decreases with time by deterioration. T-history method and measurement using heat-flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different to the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtained rea-sonable values for heat of fusion.

Synthesis and Properties of Calix[4]crown-6 Functionalized Polymers

  • Kim Su-Han;Lee Chil-Won;Jeon Young-Min;Gong Myoung-Seon
    • Macromolecular Research
    • /
    • v.13 no.2
    • /
    • pp.141-146
    • /
    • 2005
  • Calix[4]crown-6-2,4-bis(4-aminobutyl ether), which has a crown-6 moiety at the 1,3-position and amino function at the 2,4-position, was prepared as an intermediate for the subsequent synthesis of calix[4]crown-6-containing polyamide and polyimide using adipoyl chloride and 1,2,4,5-benzenetetracarboxylic dianhydride. The chemical structures were characterized by IR, $^{1}H NMR$ spectroscopy and elemental analysis, and some of their physical properties, including their thermal behavior, were examined. The ion binding characteristics of the monomer and polymers for alkali metal and alkali earth metal ions were measured by liquid-liquid extraction from the aqueous phase into the organic phase. It has been observed that polyamide has a high binding ability towards various metal cations as compared to polyimide, which showed cesium ion selectivity.

Fabrication of a Large LCD Backlight Unit with Red, Green, and Blue LED Lamps

  • Kim, Hee-Tae;Noh, Seung-Jeong;Choi, Yong-Seok;Yu, Soon-Jae
    • Journal of Information Display
    • /
    • v.10 no.3
    • /
    • pp.97-100
    • /
    • 2009
  • A backlight unit for a 42-inch LCD TV was manufactured with red, green, and blue LED lamps. The luminous and light extraction efficiencies of the LED lamps were increased by improving their light reflection structures and thermal properties. The blue, green, and red LED lamps showed different luminous efficiencies as a function of the input current. Compared to the conventional red LED lamp, however, the developed red LED lamp showed very high luminous efficiency in a low drive current. Taking these luminous efficiencies into account, the fabricated backlight unit showed high energy efficiency, low power consumption, and a wide color gamut.

Development of Composite Bipolar Plate for PEMFC (고분자 전해질 연료전지용 복합수지 분리판 개발)

  • Kang, Hyun-Min;Han, In-Su;Lim, Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.5-7
    • /
    • 2007
  • Graphite/polymer composite bipolar plates for PEMFC are successfully developed, and their typical properties are superior to commercially available ones. Thermal property of the developed bipolar plate was evaluated by dynamic mechanical analyzer, and the results were compared to commercial ones. The specimens were immersed into the deionized water bath at $80^{\circ}C$ for 1500hrs to evaluate dimensional stability and durability. Dimension, weight of the specimens as well as extraction conductivity was measured as each 500hrs. Fully molded bipolar plates without any machining or milling were also prepared using a specially developed mold, and they were applied to the fuel cell performance test. Results were compared to the machined commercial bipolar plate.

  • PDF