• 제목/요약/키워드: thermal distribution

검색결과 3,042건 처리시간 0.03초

실리콘에 MaV로 이온주입된 인의 결함분포와 profile에 관한 연구 (A Study of defect distribution and profiles of MeV implanted phosphorus in silicon)

  • 정원채
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권9호
    • /
    • pp.881-888
    • /
    • 1997
  • This study demonstrats the profiles of phosphorus ions in silicon by MeV implantation(1∼3 MeV). Implanted profiles could be measured by SIMS(Cameca 4f) and compared with simulation results(TRIM program and analytical description method only using on Pearson function). The experimental result in the peak concentration region has a little bit deviation from simulation data. By RBS and Channeling measurements the defect distribution of implanted samples could be measured and spectrum are calibrated depth with RUMP simulation By XTEM measurement the thickness of defect zone also could be measured. Finally thermal annealing for the electrical activation of implanted ions carried out by RTA(rapid thermal annealing). The concentration-depth profiles after heat treatment was measured by SR(spreading resistance)-method.

  • PDF

FPGA implementation using a CLAHE contrast enhancement technique in the termal equipment for real time processing

  • Jung, Jin-Hyun
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권11호
    • /
    • pp.39-47
    • /
    • 2016
  • In this paper, we propose an approach for real time computation of rayleigh CLAHE using a FPGA. The contrast enhancement technique should be applied in thermal equipment having a low contrast image. And thermal equipment must be processed in real time. The CLAHE is an improved algorithm based Histogram Equalization, but the HW design is complex. A value greater than a given threshold in CLAHE should be equally distributed on the other histogram bin, this process requires iterations for the distribution. But implementation of this processing in the FPGA is constrained, so this section was implemented on the assumption of the histogram distribution or modified the operation process or implemented separately in the CPU. In this paper, we designed a distinct redistribution operation in two stages. So FPGA was designed for easy, this was designed to be distributed evenly without the assumptions and constraints. In addition, we have designed a CLAHE with the rayleigh distribution to the FPGA. The simulation shows that the proposed method provides a better image quality in the thermal image.

CORE AND SUB-CHANNEL EVALUATION OF A THERMAL SCWR

  • Liu, Xiao-Jing;Cheng, Xu
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.677-690
    • /
    • 2009
  • A previous study demonstrated that the two-row fuel assembly has much more favorable neutron-physical and thermal-hydraulic behavior than the conventional one-row fuel assemblies. Based on the newly developed two-row fuel assembly, an SCWR core is proposed and analyzed. The performance of the proposed core is investigated with 3-D coupled neutron-physical and thermal-hydraulic calculations. During the coupling procedure, the thermal-hydraulic behavior is analyzed using a sub-channel analysis code and the neutron-physical performance is computed with a 3-D diffusion code. This paper presents the main results achieved thus far related to the distribution of some neutronic and thermal-hydraulic parameters. It shows that with adjustment of the coolant and moderator mass flow in different assemblies, promising neutron-physical and thermal-hydraulic behavior of the SCWR core is achieved. A sensitivity study of the heat transfer correlation is also performed. Since the pin power in fuel assemblies can be non-uniform, a sub-channel analysis is necessary in order to investigate the detailed distribution of thermal-hydraulic parameters in the hottest fuel assembly. The sub-channel analysis is performed based on the bundle averaged parameters obtained with the core analysis. With the sub-channel analysis approach, more precise evaluation of the hot channel factor and maximum cladding surface temperature can be achieved. The difference in the results obtained with both the sub-channel analysis and the fuel assembly homogenized method confirms the importance of the sub-channel analysis.

Experimental and finite element parametric investigations of the thermal behavior of CBGB

  • Numan, Hesham A.;Taysi, Nildim;Ozakca, Mustafa
    • Steel and Composite Structures
    • /
    • 제20권4호
    • /
    • pp.813-832
    • /
    • 2016
  • This research deals with the behavior of Composite Box Girder Bridges (CBGBs) subjected to environmental effects such as solar radiation, atmospheric temperature, and wind speed. It is based on temperature and thermal stress results, which were recorded hourly from a full-scale experimental CBGB segment and Finite Element (FE) thermal analysis. The Hemi-cube method was adopted to achieve the accuracy in temperature distributions and variations in a composition system during the daily environmental variations. Analytical findings were compared with the experimental measurements, and a good agreement was found. On the other hand, parametric investigations are carried out to investigate the effect of the cross-section geometry and orientation of the longitudinal axis of CBGB on the thermal response and stress distributions. Based upon individual parametric investigations, some remarks related to the thermal loading parameters were submitted. Additionally, some observations about the CBGB configurations were identified, which must be taken into account in the design process. Finally, this research indicates that the design temperature distribution with a uniform differential between the concrete slab and the steel girder is inappropriate for describing the thermal impacts in design objective.

마이크로 리포머의 열 및 역학적 거동 분석 (A Study on Thermal and Mechanical Behaviors of Micro Reformer)

  • 황원재;장재혁;길재형;김상진;이로운;김성한;정기호;오용수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.235-239
    • /
    • 2005
  • We analyzed the thermal and mechanical behaviors of micro reformer for the purpose of design verifications and modification of micro channels. The reformer designed for hydrogen generation from methanol is essential to PEM(Proton Exchange Membrane) type fuel cell. For the mobile applications, the size and the simplicity would be the most critical issues. We utilized silicon process for micro reformer to obtain the thickness thinner than 2 mm thick. We have used commercial simulation software, IDEAS, to analyze the thermal and mechanical characteristics of micro reformer structure. The heat generation rates of heaters, heat transfer rates, and fluid temperatures are derived from thermal equilibrium relation and these values were used for thermal boundary conditions. We also analyzed the thermal stresses, thermal deformations to examine the possibility of failure.

  • PDF

대구 세계육상선수권대회 마라톤 구간의 열환경변화분석 (Analysis on Thermal Environment of Marathon Course in 2011 Daegu World Championship in Athletics)

  • 백상훈;오상학;정용훈;정응호
    • 한국환경과학회지
    • /
    • 제20권7호
    • /
    • pp.881-890
    • /
    • 2011
  • In this study, thermal environment changes for a marathon course of IAAF World Championship, Daegu 2011 were modeled to provide improvements of thermal environment, so that runners could have the maximum condition and citizens pleasant streets. The three biggest size of intersections were selected for the study. Envi-met, 3G microclimate model, were used for a thermal environment analysis and three different cases - present status, planting roadside tree scenario, and roof-garden scenario - were compared. The followings are the results of the study. 1. The highest thermal distribution were shown at 1 p.m., but there was no significant difference between a thermal distribution at 1 p.m. and that at 5 p.m. since a heat flux from buildings affects thermal distributions rather than insolation does. 2. Tree planting or adding environmental friendly factors might lead a temperature drop effect, but the effect was not significant for areas covered with impermeability packing materials such as concrete or asphalt (especally, for Site case 2) 3. The combination of tree planting and adding environmental friendly factors also brought a temperature drop effect (Site 1 and 2) and this case showed even better result if green spaces (especially, parks) were closed.

주택용 분전반에 설치되는 서지보호기의 열적 안전성 시험 및 분석 (A thermal stability testing and analysis for a surge protector installed in residential distribution board)

  • 김주철;박장범;기채옥
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.339-341
    • /
    • 2009
  • 개별세대 내 정보통신기기 및 홈네트워크 장비증가로 인하여 서지보호장치(SPD : Surge Protective Device)가 설치되고 있고 산업규격개정 및 등전위 접지시스템 강화에 따라 서지보호기 사용량은 점진적으로 증가하고 있다. 주택용 분전반에 설치되는 서지보호기의 부품은 전압제한형 소자인 $Z_nO$배리스터가 사용되고 있으나 일시적 과전압특성 (Temporary Overvoltage Characteristic) 위험에 노출되어있다. 본 논문은 일반주택에 사용되는 서지보호기의 열적 안전성 (Thermal Stability) 특성시험을 통하여 제품을 분석하였고 이를 토대로 개선안을 제시하였다. 분석결과 누설전류를 차단하기위한 가스 방전관(GDT) 사용 및 열폭주(Thermal Runaway) 현상을 막기 위한 안전장치가 2종 이상 필요하였다.

  • PDF

Active NPC 인버터의 손실 분배 제어를 위한 뉴턴의 냉각법칙 기반의 간단한 열 모델링 기법 (Convenient Thermal Modeling for Loss Distribution method of 3-Level Active NPC Inverter using Newton's Law of cooling)

  • 현승욱;이정효;원충연
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.71-80
    • /
    • 2015
  • This paper proposes a convenient thermal modeling method for loss distribution control method of 3-level Active NPC(Neutral Point Clamped) inverter. In the drawback of conventional 3-level NPC, the generated losses can occur unbalance in each switching device, as a result, thermal utilization of designed system has been decreased. In order to compensate unbalanced losses, Active NPC inverter performed loss balancing control with thermal modeling during operation of each switching device. Therefore, this paper deals with a convenient thermal modeling method based on newton's law of cooling rather than conventional thermal modeling method. Both simulation and experimental results based on 10kW 3-level Active NPC inverter confirm the validity of the analysis performed in the study.

세라믹 촉매 담체의 내구 설계 기준에 대한 실험 및 수치해석의 비교 (Comparison of Experimental and Numerical Analysis for Durability Design Criteria in Ceramic Catalyst Substrate)

  • 백석흠;조석수
    • 한국정밀공학회지
    • /
    • 제27권9호
    • /
    • pp.58-66
    • /
    • 2010
  • This study examines thermal safety on three-way catalyst that dominates 70 % among whole exhaust gas purification device in 2003. Three-way catalyst durability in the Korea requires 5 years/80,000 km in 1988 but require 10 years/120,000 km after 2002. Three-way catalyst durability in the USA requires 7 years/120,000 km but require 10 years/160,000 km after 2004. Three-way catalyst maintains high temperature in interior domain but maintains low temperature on outside surface. Therefore this device shows tensile stress on outside surface. Temperature distribution of three-way catalyst was acquired by thermal flow analysis for predicted thermal flow parameter. Thermal stress analysis for three-way catalysis was performed based on this temperature distribution. Thermal safety of three-way catalyst was estimated by power law dynamic fatigue life estimation and strength reduction methods for thermal stress.

예압과 냉각조건에 따른 고주파 모터 내장형 주축계의 열특성 (Thermal Characteristics of the High Frequency Motor Spindle according to the Bearing Preloads and Cooling Conditions)

  • 최대봉;김수태;정성훈;김진한;김용기
    • 한국공작기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.31-36
    • /
    • 2005
  • Use of the high frequency motor spindles are increasing for the high speed machine tools recently. The important problem in the high speed spindles is to reduce and minimize the thermal effect by the motor and ball hearings. Thermal characteristics according to the bearing preload and spindle cooling are studied for the spindle with the oil mist lubrication and high frequency motor. Temperature distribution and thermal displacement according to the spindle speed, preload and flow rate are measured. Temperature distribution and thermal displacement of the high speed spindle system can be estimated reasonably by using the three dimensional model through the finite element method. The results of analysis are compared with the measured data. This study supports thermal optimization and find out more effective cooling condition. This paper show that the suitable preload and spindle cooling are very effective to minimize the thermal effect by the motor and ball bearings.