• Title/Summary/Keyword: thermal change

검색결과 3,136건 처리시간 0.037초

산화물이 Doping된 YSZ의 고온 열처리에 따른 Monoclinic 상변화 및 미세구조 분석 (Analysis of Monoclinic Phase Change and Microstructure According to High-temperature Heat Treatment of Oxide-doped YSZ)

  • 이계원;최용석;전창우;이인환;오윤석
    • 한국분말재료학회지
    • /
    • 제29권6호
    • /
    • pp.468-476
    • /
    • 2022
  • Yttria-stabilized zirconia (YSZ) has a low thermal conductivity, high thermal expansion coefficient, and excellent mechanical properties; thus, it is used as a thermal barrier coating material for gas turbines. However, during long-time exposure of YSZ to temperatures of 1200℃ or higher, a phase transformation accompanied by a volume change occurs, causing the YSZ coating layer to peel off. To solve this problem, YSZ has been doped with trivalent and tetravalent oxides to obtain coating materials with low thermal conductivity and suppressed phase transformation of zirconia. In this study, YSZ is doped with trivalent oxides, Nd2O3, Yb2O3, Al2O3, and tetravalent oxide, TiO2, and the thermal conductivity of the obtained materials is analyzed according to the composition; furthermore, the relative density change, microstructure change, and m-phase formation behavior are analyzed during long-time heat treatment at high temperatures.

냉장고 가스켓 주위 형상 및 물성치 변화에 의한 열손실 영향 연구 (The Effect of Gasket Shape and Material Properties on Heat Losses in a Refrigerator)

  • 하지수;정광수;김태권;심재성
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.413-418
    • /
    • 2010
  • The amount of heat loss of a refrigerator through the gasket is nearly 30% of total refrigerator heat loss. In this paper, quantitative evaluation for the effects of various effort to reduce heat losses through the gasket. The first trial is to extend the inner gasket to prevent the heat loss flowing from the inner of refrigerator. The effects of thermal conductivity changes of gasket and magnet are investigated by the numerical heat transfer analysis. The position change of hot line is also examined in the present research. From the present result of the numerical simulation of heat transfer, we are able to reduce the heat loss about 20~40% by using inner gasket extension. The reducing of thermal conductivity of gasket is considerable in the heat loss reduction. On the other hand, the thermal conductivity change of magnet has no apparent effect in heat loss reduction. The position change of hot line has considerable positive effect in the reduction of heat loss near gasket region.

남극 및 시베리아 흙의 동토공학적 특성 분석 (Engineering Characteristics of Antarctic and Siberian Frozen Soils)

  • 김영진;신재원;김현기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.894-904
    • /
    • 2008
  • In this study, soil samples from the Antarctic and Vladivostok, Siberia were tested in the laboratory, and specific gravity, compaction curve and grain size distribution were determined. The effect of temperature change on the thermal conductivity, unfrozen water content and compressive strength were investigated. Samples for the compressive strength test were prepared in a mold with a fixed volume to prevent swelling and the effect of temperature and water content change on the strength were compared. Results from the thermal conductivity test showed that thermal conductivity values for both soils were larger at temperatures below freezing than above freezing. The unfrozen water content dropped sharply within a temperature range of $0{\sim}-5^{\circ}C$ and then gradually decreased further up to $-20^{\circ}C$. Compressive strength test results showed various stress/deformation curves with a change in water content. Sandy soil had much larger strength than pure ice at an identical temperature, while clayey soil had a smaller strength than ice near the freezing point, but showed a larger strength at temperatures belows $-15^{\circ}C$.

  • PDF

진동형 히트 파이프에서 튜브의 지름과 개수에 따른 전산 열유동해석 (COMPUTATIONAL ANALYSIS OF THERMAL FLOW WITH VARYING THE DIAMETER AND THE NUMBER OF TUBES IN PULSATING HEAT PIPES)

  • 한성현;최종욱;김성초
    • 한국전산유체공학회지
    • /
    • 제21권1호
    • /
    • pp.86-93
    • /
    • 2016
  • In this paper, heat transfer characteristics of pulsating heat pipes are investigated with the diameter and the number of tubes through the computational analysis of thermal flow. The numerical simulation includes the phase change precess with VOF model using OpenFOAM software. The numerical code is modified for the phase change to occur with saturation temperature. The numerical results are compared with the previous ones to validate the present code. The resonable results have been obtained based on the mass transfer time relaxation parameter considering the density ratio. When the ratio of length to diameter and the number of tubes are on the decrease, the thermal resistances also tends to decrease in the pulsating heat pipes. These numerical results will supply the base line data to design and to manufacture the pulsating heat pipe.

자외선 조사에 따른 게르마늄 함유 다성분계 산화물 유리의 광흑화와 열표백화 현상 (Photodarkening and Thermal Bleaching Effect in Ge-doped Multicomponent Oxide Glasses by UV Irradiation)

  • 이회관;오영석;강원호
    • 한국산학기술학회논문지
    • /
    • 제3권3호
    • /
    • pp.161-165
    • /
    • 2002
  • 게르마늄첨가 다성분계 산화물 유리를 제조하여 자외선(UV) 조사에 따른 유리의 미세 구조변화를 PL(photo-luminescence)과 ESR(electron spin resonance)을 이용하여 관찰하였다. 게르마늄 첨가량이 증가함에 따라 PL방사량은 증가하였으며, UV 조사 후에는 처음과 반대되는 광혹화 현상으로 감소하는 현상을 나타냈다. UV조사로 변화된 특성은 열처리를 통하여 회복이 가능하였으며, ESR 측정에서도 PL결과와 같은 광혹화 현상(phodarkenine effect)과 열표백화 현상(thermal bleaching effect)이 확인되었다. 또한, XRD 분석을 통하여 이러한 현상이 비정질 상은 그대로 유지하는 미세구조 변화임을 알 수 있었다.

  • PDF

태양광패널 온도제어를 위한 PCM시스템 최적화에 관한 실험적 연구 (Experimental study for optimizing the thermal regulating system with phase change material on the photovoltaic panel)

  • 이효진;전종한
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.273-278
    • /
    • 2009
  • The experimental study is performed to investigate the optimum design of the system dissipating properly heat from the in-situ solar panel installed on site. For this purpose, six 12-Watts panels, which are set at the different conditions of the solar panels contained phase change material, changing the array of the aluminum fin and honeycomb at the back of the panel, are tested. PCM, which has $44^{\circ}C$ melting point, is chosen in this study. In order to enhance the thermal heat from the absorbed heat in PCM, finned aluminum plate is placed. Furthermore, Aluminum honeycomb is imbedded in the back container to find if it would improve the thermal conductivity of PCM. As a result, the solar panel, which is combined with honeycomb and outward fins with PCM instead of placing the fine inward, is showing the best performance in terms of controling panel temperature and efficiency.

  • PDF

하절기 차열성능을 갖는 방수재의 적용에 따른 건축물 표면온도 변화추이 연구 (A Study on the Surface Temperature Change of Building Applied with Thermal Insulation Waterproofing Material During Summer)

  • 김동범;박진상;최수영;박재홍;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2017
  • As the environment and energy problems such as global climate change (global warming, urban heat island phenomenon) and energy depletion have come to the fore, the construction and waterproofing industry are responding more critically to the demands of global green technology and are employing more eco-friendly technologies as of recent. In this study, the application of the waterproofing material with thermal response performance in construction buildings was investigated to confirm whether the thermal performance is being properly secured by the change of the surface temperature. Experimental results showed that the surface temperature difference between before and after the application is at least 19.8℃ at the maximum 26.3℃. When the degradation rate is converted, the degradation effect of about 40% on average was confirmed.

  • PDF

탄성에폭시의 열적.기계적 특성에 관한 연구 (Study on the Thermal and Mechanical Properties of Elastic Epoxies)

  • 민지영;이관우;이경용;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.248-251
    • /
    • 2003
  • In this paper, it was experimented about thermal and mechanical insulation properties of a elastic epoxy specimen. We made elastic epoxy specimen adding a ratio of 0[phr], 20[phr], 35[phr] and 53[phr] with modifier to existing epoxy. Each specimen was absorbed by 25h, 196h, 361h 484h with water. In water-absorption state, it was experimented a change of heat flows by temperature of elastic epoxy and changes of thermal expansion coefficient. Also, a hardness-change of each specimen was experimented by change of water-absorption time. In this experiment DSC (Differential Scanning Calorimetry) and TMA (Thermomechanical Analysis) were used. A temperature range of DSC was changed from -0[$^{\circ}C$] to 200[$^{\circ}C$], TMA was changed from -0[$^{\circ}C$] to 350[$^{\circ}C$]. In addition, we investigated structural analysis of water absorbed specimen using SEM (Scanning electron microscope).

  • PDF

시효 열처리 된 Al-Si-Mg-Cu-(Ti) 합금의 고온 열팽창 계수 변화 (Changes in High-temperature Coefficient of Thermal Expansion of Artificial Aging Heat-treated Al-Si-Mg-Cu-(Ti) Alloys)

  • 최세원
    • 열처리공학회지
    • /
    • 제34권5호
    • /
    • pp.226-232
    • /
    • 2021
  • The relationship between precipitation and coefficient of thermal expansion of Al-6%Si-0.4%Mg-0.9%Cu-(Ti) alloy (in wt.%) after various heat treatments were studied by the thermodynamic analyzer (TMA) and differential scanning calorimetry (DSC). Solution heat treatment of the alloy was carried out at 535℃ for 6 h followed by water quenching, and the samples were artificially aged in the air at 180℃ and 220℃ for 5 h. The coefficient of thermal expansion (CTE) curve showed some residual strain and decreased with increasing aging temperature. The CTE curves changed sharply in the temperature range of 200℃ to 400℃, and the corresponding peak shifted for the aged samples due to the change in the precipitation behavior of the secondary phase. These transformation peaks in the aged sample are related to the volume of the precipitation of the Si phase as determined by DSC analysis. The change in CTE is mainly caused by the precipitation of the Si phase in the Al-Si alloy, and the size of the change occurs simultaneously with the size of the precipitate.

공기구동밸브의 열노화에 따른 성능평가 (Performance Analysis of Air Operated Valve by Thermal Aging)

  • 이선기
    • 동력기계공학회지
    • /
    • 제19권5호
    • /
    • pp.93-98
    • /
    • 2015
  • Nuclear power plants has a number of valves, which are operating at a high temperature-high pressure and radiation environment conditions. Nevertheless, it is important to maintain the reliability of the valves to ensure safe operation of the nuclear power plant. However, the aging of the valves by increasing of years of plant operation and the system transients due to the sudden load change are working the failures of the reliability of the valve. In this paper, we evaluate experimentally the performance change according to the thermal aging of the valve. Results show that the valve stem and the actuator leakages were enlarged by the thermal aging.