• Title/Summary/Keyword: thermal change

Search Result 3,136, Processing Time 0.028 seconds

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

The Effects of Additives on the Thermal Properties of a Clathrate Compound (II) -The Case of Ethylene Glycol- (포접화합물의 열물성에 미치는 첨가제의 효과 (II) -TMA 물계 포접화합물에 Ethylene Glycol을 첨가한 경우-)

  • 정낙규;김진흥;김창오;김광일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.499-505
    • /
    • 2004
  • The objective of this study is to investigate the effect of supercooling repression on the TMA clathrate by adding ethylene glycol. For this purpose, phase change temperature, supercooling, specific heat, latent heat and rate of volume change were measured and evaluated experimentally for heat source temperatures of -6$^{\circ}C$, -7$^{\circ}C$, -8$^{\circ}C$. The results show that supercooling was decreased. Thus the experimental results are expected to be used for the increase of coefficient of performance of low temperature thermal storage system in the building.

A Study on the Place of Break Chair Thermal Environment Change with the Introduction of the Indoor Water Space (실내 수공간으로 인한 온열환경 변화와 휴식의자 배치 방안)

  • Kang, Yujin;Song, Junhee;Chung, Okyoung;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.3
    • /
    • pp.239-246
    • /
    • 2013
  • Recently the building is introducing the indoor water space. Thermal environment change with the introduction. Consequently, this study shows how water space in the public facility affects the indoor environment. We had put our experiment to measure the humidity and temperature differences in different distances of water space. The result of this study is as follows. First, We found that even though there's a water space, it makes no big change in temperature by different distance. The temperature was only maintained by a cooler. Second, As there's a water space, the humidity was affected by within 1.5 m of it. Through our experimental result, we have started our study to make a water space effective.

  • PDF

A Study on the Surface Degradation Phenomena and Electrical Properties of Polymer Composite Materials (고분자 복합재료의 표면 열화 현상과 전기적 특성에 관한 연구)

  • Park, Jae-Sae;Lim, Kyung-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.75-78
    • /
    • 2002
  • In this paper, we investigated the change of wettability, surface potential decay and surface resistivity caused by thermal-treated and plasma-treated FRP respectively for finding out the influence of electrical characteristics on the surface of polymer composites. For the change of wettability, the contact angle of thermal-treated specimen with the high temperature of 200$^{\circ}C$ increased. But that of plasma-treated specimen decreased. The characteristic of surface potential decay shows the tendency of the remarkable decrease on plasma-treated specimens, but no difference on thermal-treated specimen compared with untreated one. Also, for the surface resistivity, it shows the same trend compared with the change of contact angle. We can conclude that the degradation phenomena of epoxy surface are dominated by the induction of hydrophilicity and hydrophobicity.

  • PDF

Hardness Distribution and Dimensional Change after Partial- Hardened Hot Stamping of Automotive Body Part (국부 연화 핫스탬핑 차체 부품의 경도 분포 및 열 변형 거동)

  • Jeong, Woo Chang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.2
    • /
    • pp.66-73
    • /
    • 2022
  • Partial-hardened hot stamping has been well known to be very effective to absorb more energy in automotive lateral crash. Hardness distribution and dimensional change after partial-hardened hot stamping have been studied to find out effect of thermal deformation of the heated hot stamping die on dimensional accuracy of automotive center pillar. Soft zone of commercial center pillar showed 275~345 in Vickers hardness, indicating bigger non-uniformity which resulted from thermal deformation of heated die. Dimensional changes in soft zone of the commercial center pillar measured by three dimensional scanner were much bigger than that in hard zone. It has been found that hot stamping die compensation considering thermal deformation in soft zone causes a significant decrease in hardness deviation in the soft zone, corresponding to 20 percent of commercial center pillar and subsequently leads to much higher dimensional accuracy.

Study for Effect of Changes in Thermal Properties on Cooling Process in Running Hot Steel Strip After Hot Rolling (열간압연 이후 주행하는 고온 강재의 냉각해석에서 소재의 물성변화 효과 연구)

  • Park, Il Seouk;Park, Jung Eun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.459-465
    • /
    • 2013
  • In the manufacturing process of steel plates, materials at high temperatures above $800^{\circ}C$ are rapidly cooled by using a circular impinging water jet to determine their strength and toughness. In this study, the basic heat and fluid flow is solved by using the existing numerical model for boiling heat transfer. Actually, steel undergoes a phase change from austenite to ferrite or bainite during the cooling process. The phase change induces changes in its thermal properties. Instead of directly solving the phase change and the material cooling together, we solve the heat transfer only by applying the thermal properties that vary with temperature, which is already known from other studies. The effects of the changes in the thermal properties on the cooling of steel and the necessity of calculating the phase change are discussed.

Feasibility Study of Cold Storage System to Maintaining Cooling Performance for ISG Vehicle (공회전 제한장치 차량에서 냉방 성능 유지를 위한 축냉 시스템 적용에 대한 연구)

  • Lee, Daewoong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • This study explores the feasibility of a cold storage system to provide thermal comfort for idle stop and go (ISG) vehicles. ISG function is the most valuable and environmental friendly technology in the current automobile industry. However, when an ISG vehicle stops, meaning when the engine standstill, the air-conditioning system does not work, because the compressor also stops. Therefore, passenger thermal comfort is not maintained, as cold air is not provided in the cabin. Consequently, many automakers have studied electric air-conditioning systems based on electrically-driven compressors or cold storage systems using phase-change materials. The experiments herein were conducted for the feasibility testing of different types of cold storage heat-exchangers, cold storage mediums, and thermo-expansion valves with current air-conditioners. The auxiliary cold storage system, filled with phase-change materials, was located behind the evaporator and almost stacked on top of it. In the experimental results, the air discharge temperature rate of increase was better than the conventional air-conditioning system when the compressor stopped and thermal comfort was maintained with $1.9{\sim}4.3^{\circ}C$ decreases within 60 seconds. The #1 cold storage heat-exchanger (CSH), #2 thermo-expansion valve (TXV) and #2 phase change material (PCM) were chosen because of the best temperature rise delay. It was concluded that a cold storage system is an effective solution for ISG vehicles to maintain thermal comfort during short engine stops.

Measurement of CTE Change in a Composite Laminate with Aging under Space Environment using Fiber Optic Sensors (광섬유센서를 이용한 우주환경하에서 복합재료 적층시편의 노화에 따른 열팽창계수변화 측정)

  • Gang,Sang-Guk;Gang,Dong-Hun;Kim,Cheon-Gon;Hong,Chang-Seon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.21-26
    • /
    • 2003
  • In this research, the change of coefficient of thermal expansion (CTE) of graphite/epoxy composite laminate under space environment was measured using fiber optic sensors. Two fiber Bragg grating (FBG) sensors have been adopted for the simultaneous measurement of thermal strain and temperature. Low Earth Orbit (LEO) conditions with high vacuum, ultraviolet and thermal cycling environments were simulated in a thermal vacuum chamber. As a pre-test, a FBG temperature sensor was calibrated and a FBG strain sensor was verified through the comparison with the electric strain gauge (ESG) attached on an aluminun specimen at high and low temperature respectively. The change of the CTE in a composite laminate exposed to space environment was measured for intervals of aging cycles in real time. As a whole, there was no abrupt change of the CTE after 1000 aging cycles. After aging, however, the CTE decreased a Little all over the test temperature range. These changes are caused by outgassing, moisture desorption, matrix cracking etc.

Numerical Study on the Thermal Control Device for Satellite Components Using the Phase Change Material Combined with Heat Pipe in Parallel (상변화물질과 열관을 병렬 조합한 위성부품 열제어장치의 수치해석적 연구)

  • Shin, Yoon Sub;Kim, Tae Su;Kim, Taig Young;Seo, Young Bae;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.4
    • /
    • pp.373-379
    • /
    • 2016
  • The thermal control device for the periodic working component combined solid-liquid phase change material (PCM) with heat pipes is designed and numerically studied. Due to high latent heat and retaining constant temperature during melting process the component peak temperature, not withstanding small radiator size, is reduced. The warm-up heater power consumption to keep the minimum allowed temperature is also cut down since the accumulated thermal energy is released through the solidification. The thermal buffer mass (TBM) made of Al can give the similar effect but the mass and power consumption of warm-up heater should increase compared to PCM. The amount of PCM can be optimized depending on the component heat dissipation and on/off duty time.

An Experimental Study on the Thermal Properties of High Strength Concrete in the Range of $40{\sim}100MPa$ at High Temperature (고온시 $40{\sim}100MPa$ 범위의 콘크리트 열적특성에 관한 실험적 연구)

  • Kim, Heung-Youl;Jeon, Hyun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.425-428
    • /
    • 2006
  • In order to estimate the reduction of laodbearing capacity, followed by the attributive change of heat while high strength concrete structure is revealed on fire it is necessary to evaluate, it is necessary to evaluate the property of material under high temperature such as thermal conductivity, specific heat, compressive strength, modulus of rigidity and diminution figure. Therefore, this study is for the purpose of presenting evaluation data for the analysis of thermal behavior about the high strength concrete material under high temperature, through the experiment by manufacturing concrete(40, 50, 60, 80, 100 MPa) commonly used in the construction field. As a result of the study, in the case of physical attribute, it demonstrates a greater fluctuation of change than the one of 30 MPa concrete. In case of specific heat, the high strength concrete, shown the serious diminution between $500{\sim}600^{\circ}C$, presents the thermal change area corresponding to the change of high strength concrete. In compressive strength, regardless of intensity of concrete, all of them show the first intensity loss between normal temperature and $100^{\circ}C$, the dramatic loss beyond $400^{\circ}C$. The concrete weighing above 50 MPa shows a twice lower dramatic intensity loss than the one weighing $30{\sim}40MPa$. The concrete ranging from $60{\sim}80MPa$, shows the biggest diminution of modulus of elasticity under $400^{\circ}C$, which implies the structural unstability of temperature.

  • PDF