• Title/Summary/Keyword: thermal camera

Search Result 520, Processing Time 0.026 seconds

A Study on the Establishment of Urban Life Safety Abnormalities Detection Service Using Multi-Type Complex Sensor Information (다종 복합센서 정보를 활용한 도심 생활안전 이상감지 서비스 구축방안 연구)

  • Woochul Choi;Bong-Joo Jang
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.315-328
    • /
    • 2024
  • Purpose: The purpose of this paper is to present a service construction plan using multiple complex sensor information to detect abnormal situations in urban life safety that are difficult to identify on CCTV. Method: This study selected service scenarios based on actual testbed data and analyzed service importance for local government control center operators, which are main users. Result: Service scenarios were selected as detection of day and night dynamic object, Detection of sudden temperature changes, and Detection of time-series temperature changes. As a result of AHP analysis, walking and mobility collision risk situation services and fire foreshadowing detection services leading to immediate major disasters were highly evaluated. Conclusion: This study is significant in proposing a plan to build an anomaly detection service that can be used in local governments based on real data. This study is significant in proposing a plan to build an anomaly detection service that can be used by local governments based on testbed data.

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

투명 면상 발열체 응용을 위한 하이브리드 스퍼터 ITO / Ag / ITO 박막의 물성평가

  • Kim, Jae-Yeon;Park, So-Yun;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.252-252
    • /
    • 2016
  • 최근 학계나 산업계에서 indium tin oxide (ITO)의 높은 전기 전도도 및 광투과율을 이용하여 줄 발열을 기초로 하는 투명 면상 발열체에 대한 연구가 활발히 진행 되고 있다. 하지만 단일 ITO 박막으로 제작한 투명 면상 발열체는 온도가 상승함에 따라 균일하게 발열 되지 않으며, 글라스의 곡면 부분에서 유연성이 부족하여 크랙이 발생하는 다양한 문제점들을 가지고 있다. 이를 해결하기 위해 ITO의 결정화 온도 $160^{\circ}C$ 이상의 고온공정 또는 증착 후 열처리가 필요 하는 추가적인 공정이 필요하다. 따라서 본 연구에서는 단일 ITO 박막의 단점을 개선하는 ITO/Ag/ITO 하이브리드 구조의 투명 면상 발열체를 제작하여 전기적, 광학적 특성을 비교하고 발열량, 온도 균일성, 발열 유지 안정도를 조사하였다. 본 연구에서는 $50{\times}50mm$ 크기의 non-alkali glass (Corning E-2000) 기판 상에 마그네트론 스퍼터링 공정으로 상온에서 ITO/Ag/ITO 박막을 연속적으로 증착 하여 다층구조의 하이브리드 형 투명 면상 발열체를 제조하였다. 박막 증착 파워는 DC (Ag) power 100 W, RF (ITO) power 200 W로 하였으며 ITO박막두께는 40 nm로 고정 시키고 Ag박막 두께는 10 ~ 20 nm로 변화를 주었다. 증착원은 3인치 ITO 단일 타깃(SnO2, 10 wt.%)과 Ag 금속 타깃 (순도 99.99%)을 사용하였으며, 고순도 Ar을 이용하여 방전하였으며 총 주입량은 20 sccm, working pressure는 1.0 Pa을 유지하였다. 증착전 타깃 표면의 불순물 제거와 방전의 안정성을 유지하기 위해 10분간 pre-sputtering을 진행하고 증착하였다. 증착한 박막의 전기적, 광학적 특성은 각각 Hall-effect measurements system (ECOPIA, HMS3000), UV-Vis spectrophotometer (UV-1800, SHIMADZU)으로 측정하였으며, 하이브리드 표면의 구조 및 형상은 field emission-scanning electron microscopy (FE-SEM, Hitachi S-4800)으로 관찰하였다. 또한 투명 면상 발열체의 성능은 0.5 ~ 3 V/cm의 다양한 전압을 power supply (Keithly 2400, USA)를 통해서 시편 양 끝단에 인가한 후 시간에 따른 투명면상 발열체의 표면 온도변화를 infrared thermal imager (IR camera, Nikon)를 이용하여 관찰하였다. 하이브리드 구조를 가진 ITO박막의 두께는 40 nm로 고정 시키고 Ag박막의 두께는 10, 15, 20 nm로 변화를 주었다. 이들 박막의 면저항 값은 각각 5.3, 3.2, $2.1{\Omega}/{\Box}$였으며, 투과도는 각각 86.9, 81.7, 66.5 %였다. 이에 비해 두께 95 nm의 단일 ITO박막의 면저항 값은 $59.5{\Omega}/{\Box}$였으며, 투과도는 89.1 %였다. 하이브리드 구조의 전기적특성은 금속층의 두께가 증가할수록 캐리어 농도 값이 증가함에 따라 비저항 값이 감소되어 면저항 값도 감소된 것이며, 금속 삽입층의 전도특성이 비저항에 큰 영향을 주고 있음을 보여준다. 하지만 금속 층의 두께가 증가할수록 Ag층이 연속적인 막을 형성하여 반사율이 증가함에 따라 투과도가 감소하였다. 따라서 하이브리드 구조를 가진 투명 면상 발열체에 금속 삽입층의 두께 조절은 매우 중요한 인자임을 확인 할 수 있었다. 또한 발열성능을 평가 하기 위해 시편 양 끝단에 3 V전압을 인가한 결과, 금속 삽입층의 두께가 10 nm에서 5 nm씩 증가한 하이브리드 구조를 가진 투명면상 발열체의 최고 온도는 각각 98, 150, $167^{\circ}C$ 였으며, 단일 ITO의 최고 온도는 $32^{\circ}C$였다. 이 것은 동일한 두께 (95 nm)의 단일 ITO 박막과 비교하여 면저항이 낮은 하이브리드 박막의 발열량은 약 $120^{\circ}C$로 발열효율이 매우 우수한 것을 확인 할 수 있었다.

  • PDF

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.

The Safety Assessment of Fire needling (화침의 안전성 평가에 관한 고찰)

  • Yeon, Sun-Hee;Lee, Sae-Bhom;Kwon, O-Sang;Cho, Seong-Jin;Choi, Kwang-Ho;Lee, Sang-Hun;Choi, Sun-Mi;Ryu, Yeon-Hee
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.3
    • /
    • pp.103-110
    • /
    • 2012
  • Objectives : Fire needling has been applied as the treatment for various diseases and been getting much attention from Oriental medicine due to its excellent effectiveness as the results of clinical studies have reported. However, the research findings on the safety of treatment method, materials for the Fire needling needle materials and the possibility of burn injury during the procedure are still insufficient. Methods : A thermo imaging camera was used to confirm the temperature distribution on acupuncture needle and the treatment area during the fire needling therapy. Then the degree of thermal injury was observed by H&E stain and TUNEL assay. In addition, in order to assess the safety of acupuncture materials, we conducted MTT assay using a L6 cell line. Results : The average temperature of the skin surface was observed at $47{\sim}51^{\circ}C$ after classic fire needling and $30^{\circ}C$ after warming fire needling. Warming fire needling therapy does not induce a burn on the tissue and a third degree burn was observed locally in the muscle and skin layers after classic fire needling treatment. This confirms that hwa-acupuncture therapies do not cause major burns. According to the safety assessment test result, no cytotoxicity was detected in the warming fire needling materials. This confirms the safety of the acupuncture materials Conclusions : Various research results on the biological safety of fire needling. Since fire needling therapy induces a burn locally without leaving any scar, and as other results indicate, it is considered a safe treatment method.

A Motor-Driven Focusing Mechanism for Small Satellite (소형위성용 모터 구동형 포커싱 메커니즘)

  • Jung, Jinwon;Choi, Junwoo;Lee, Dongkyu;Hwang, Jaehyuck;Kim, Byungkyu
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.75-80
    • /
    • 2018
  • The working principle of a satellite camera involves a focusing mechanism for controlling the focus of the optical system, which is essential for proper functioning. However, research on focusing mechanisms of satellite optical systems in Korea is in the beginning stage and developed technology is limited to a thermal control type. Therefore, in this paper, we propose a motor-driven focusing mechanism applicable to small satellite optical systems. The proposed mechanism is designed to generate z-axis displacement in the secondary mirror by a motor. In addition, three flexure hinges have been installed on the supporter for application of preload on the mechanism resulting in minimization of the alignment error arising due to manufacturing tolerance and assembly tolerance within the mechanism. After fabrication of the mechanism, the alignment errors (de-space, de-center, and tilt) were measured with LVDT sensors and laser displacement meters. Conclusively, the proposed focusing mechanism could achieve proper alignment degree, which can be applicable to small satellite optical system.

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Survey on the Ratio of Kitchen to Total Space and Ventilation System Capacity of Kitchens through Case Studies in Korean Foods Restaurants (사례 조사를 통한 한식 음식점의 주방면적 비율과 환기시설의 적정성 조사)

  • Chang, Hyeja;Choi, Gyunggi;Wang, Taehwan;Kwak, Tongkyung
    • Korean journal of food and cookery science
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 2015
  • For the globalization of Korean food restaurants, the kitchens should be equipped with proper ventilation systems and space to keep clean and ensure food safety. This study aimed to examine the ratio of kitchen to total space of restaurant and the suitability of the ventilation systems employed at Korean food restaurants. Data were collected by on-site survey of 12 Korean foods restaurants in Seoul. Length and width of the restaurants were measured with scale. Temperatures and air velocity around the heating equipment, working area, and hood were measured with a thermal imaging camera anemometer and thermometer. Statistical analyses were conducted with the SPSS program. The average space of the restaurants was $25.7m^2$. The ratio of kitchen to space was 0.22 for restaurants sized $32m^2$, 0.28 for $33-66m^2$, 0.21 for $66.1-99m^2$, 0.16 for $99.1-148.5m^2$, and 0.35 for those above $148.5m^2$. Average maximum and minimum air velocity around the hood were 0.28 m/sec and 0.22 m/sec, respectively. Under these conditions, the temperature of the working area was $41^{\circ}C$, presenting an uncomfortable indoor temperature for kitchen employees to work. When classifying 3 groups based on the minimum and maximum air velocity, the temperatures near the cooking area and in the hood of the restaurants showed significant differences among the three groups. When the maximum air velocity was over 0.3 m/sec, the temperature of the cooking area was as $30.1^{\circ}C$, showing a significantly lower temperature (p<0.01). Based on these results, the kitchen space rate of 0.25 to the total space and a ventilation system maintaining a maximum air velocity over 0.3 m/sec were recommended for ensuring the food safety of Korean foods restaurants sized 66 to $99m^2$.

A Development of Active Monitoring and Approach Alarm System for Marine Buoy Protection and Ship Accident Prevention based on Trail Cameras and AIS (해상 부이 보호 및 선박 사고 예방을 위한 트레일 카메라-AIS 연계형 능동감시 및 접근경보 시스템 개발)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Kim, Hyen-Woo;Gang, Yong-Soo;Kim, Dae-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1021-1029
    • /
    • 2018
  • The marine buoys are operated in various domains, which are navigation route and danger maker, weather and environment monitoring, military strategical element, etc. If the marine buoy is damaged, there consumes many cost and time for recovery or replacement, because of severe environmental condition, and causes a risk possibility of secondary accident. In this paper, we developed an active monitoring and approach alarm providing system using trail cameras and AIS for protection for the marine buoys. To do this, we analyzed existing researches and similar systems, extracted requirements for enhancement, and designed the system architecture that applied the enhanced elements. The main considerations of system enhancement are: integration of AIS and trail cameras, adopting of phased alarm technique by approaching ships, applying of selective communication module, conducting the image processing of ships for providing alarm, and applying thermal cameras. After that, we developed the system using designed architecture and verified effectiveness of the system based on laboratory or field-level tests.