• Title/Summary/Keyword: theoretical mode

Search Result 941, Processing Time 0.025 seconds

Interpretation Applied Dynamic Symmetry and Module for the Structure Analysis in Art-Work Space (해체적 작품공간의 구조 분석을 위한 다이내믹 시미트리와 모듈 개념의 적용 및 그 해석)

  • 신연호
    • Archives of design research
    • /
    • v.13 no.3
    • /
    • pp.221-234
    • /
    • 2000
  • This thesis aims to study the space concept of the constructive mode in the work space of the postmodernism artists since 1970s. According to the changing view of the world artists, they are searching for the characteristics of having the parameter of formative organization on how they are related to the constructive system which represents the work styles. First, this study searches for the theoretical approaches of the constructive system and parameters that were studied by Le Corbusier - the module concept as the meaning of order system being used for the basic formative construction Second, when it is regarded as a formative construction in making art as the'principles of organization'(the law of living form), which was defined by Suzanne Langer in the formative theory as the organized structure shown in growth structure in mu and ecological system, the principles governing the module rules were arthmetically analysed art-work space through the dynamic symmetry of Jay Hambidge. Therefore, this study shows the principles working on the parameters for new formative organization as follows: First, the module in the work space should be designed and built from the dynamic symmetry. Second, the module should satisfy the human needs that it must be acceptable, efficient, flexible, which are the necessary and sufficient condition for the dynamic symmetry. Third, the dynamic symmetry which has the principle of Reciprocity and the principle of Complement as its primary construction principle has the common properties and the reciprocity in the construction of the work space and when it has the self similarity, it segments organically the total space without damaging the continuum.

  • PDF

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.

A Study on Characteristic Analysis of Single-Stage High Frequency Resonant Inverter Link Type DC-DC Converter (단일 전력단 고주파 공진 인버터 링크형 DC-DC 컨버터의 특성해석에 관한 연구)

  • Won, Jae-Sun;Park, Jae-Wook;Seo, Cheol-Sik;Cho, Gyu-Pan;Jung, Do-Young;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.16-23
    • /
    • 2006
  • This paper presents a novel single-stage high frequency resonant inverter link type DC-DC converter using zero voltage switching with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant converter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant converter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, fluorescent lamp and DC-DC converter etc.

Dispersion of Particle Pulse in Human Lung Airway (인체기관지내의 입자펄스 확산 실험)

  • 이진원;이동엽;추경호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.511-518
    • /
    • 1998
  • In order to develop the aerosol bolus technique which is thought to be a potential tool for probing geometries or abnormalities of small airways, an experimental system of measuring fast time variations of particle concentration in the inhaled and exhaled breathing air was developed. The system generates monodisperse sebacic acrid particles of 1 micron size and 1.2 of geometric standard deviation in high concentration of $10^8$ particles/cc, delivers a short pulse of particles at the controlled instant during inhalation using a solenoid valve, and measures the fast change of particle concentration in using the laser light scattering. Successful operation of the generator and the measuring system was confirmed by smooth concentration profiles in inhalation. It was also confirmed that maintaining a constant breathing rate is essential to stable outputs and any disturbance in flow rate near the mode (maximum concentration) induces a large number of spurious peaks in the exhalation. Experimental data without strict control of breathing flow rate showed a substantial amount of scatter. The measured results showed an improvement in scatter over the existing results. When compared with theoretical predictions from 1-D convective diffusion equation and other experiments, general characteristics of dispersion for several penetration depths showed a good agreement, but there exists some difference in absolute values, which is attributed to the difference in body conditions. Improvements are needed in the theory, especially in relation to correcting for the effect of breathing flow rate.

  • PDF

Theory of efficient array observations of microtremors with special reference to the SPAC method (SPAC 방법에 근거한 상시진동의 효과적 배열 관측 이론)

  • Okada, Hiroshi
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.73-85
    • /
    • 2006
  • Array observations of the vertical component of microtremors are frequently conducted to estimate a subsurface layered-earth structure on the assumption that microtremors consist predominantly of the fundamental mode Rayleigh waves. As a useful tool in the data collection, processing and analysis, the spatial autocorrelation (SPAC) method is widely used, which in practice requires a circle array consisting of M circumferential stations and one centre station (called "M-station circle array", where M is the number of stations). The present paper considers the minimum number of stations required for a circle array for efficient data collection in terms of analytical efficacy and field effort. This study first rearranges the theoretical background of the SPAC algorithm, in which the SPAC coefficient for a circle array with M infinite is solely expressed as the Bessel function, $J_0(rk)$ (r is the radius and k the wavenumber). Secondly, the SPAC coefficient including error terms independent of the microtremor energy field for an M-station circle array is analytically derived within a constraint for the wave direction across the array, and is numerically evaluated in respect of these error terms. The main results of the evaluation are: 1) that the 3-station circle array when compared with other 4-, 5-, and 9-station arrays is the most efficient and favourable for observation of microtremors if the SPAC coefficients are used up to a frequency at which the coefficient takes the first minimum value, and 2) that the Nyquist wavenumber is the most influential factor that determines the upper limit of the frequency range up to which the valid SPAC coefficient can be estimated.

An Explorative Study on Discourses of Adequate Validity Criterion in Qualitative Research (질적 연구의 타당도 담론에 관한 탐색적 연구 - 주관성과 사회성의 긴장을 중심으로 -)

  • Kim, Kyung-Hee;Kim, Gi-Duk;Park, Ji-Young
    • Korean Journal of Social Welfare
    • /
    • v.63 no.2
    • /
    • pp.155-177
    • /
    • 2011
  • This paper attempts to explore the universal foundation on which the discourses on the validity criteria in qualitative research should be based, and further discuss in depth the scope and direction of an adequate validity criterion in qualitative research by critical examination of previous discourses. To establish the foundation for qualitative research, first of all, the concept of quality and qualitative paradigm were examined in terms of ontology and epistemology, especially focused on the works carried out by Aristotle, Kenneth and Boyd. Secondly, the earlier studies on the validity of qualitative research were critically reviewed in terms of the theoretical findings on the concept of quality and qualitative paradigm. The major results include the following: First, the true content of quality is defined as the 'what-ness' or essence of things perceived by subjects, and qualitative paradigm as adequate framework for qualitative research is comprised of two intrinsic modes: one is the mode of awareness and the other is that of expression. Second, qualitative researchers are able to reach to the higher level of validity by considering not only the subjectivity and the originality but also the sociality in drawing a conclusion through qualitative perception. Third, the trend of previous validity discourses can be firmly summarized as the effort to overcome the effect of quantitative research and acquire the true identity for qualitative research, which is subjectivity, and as the quest to compromise the tension between subjectivity and sociality. Finally, based on the findings, several research topics are suggested. For example, the more attention should be paid to the area of the expression of qualitative awareness as a way of overcome the tension between subjectivity and publicness.

  • PDF

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

Rotor Position Sensorless Control of Optimal Lead Angle in Bifilar-Wound Hybrid Stepping Motor (복권형 하이브리드 스테핑 전동기의 회전차 위치 센서리스 최적 Lead Angle 제어)

  • Lee, Jong-Eon;Woo, Kwang-Joon
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.120-130
    • /
    • 1999
  • In this paper, we show that the instantaneous phase current of the bifiler-wound hybrid stepping motor is dependent of lead angle and that the information of motor position is obtained from the instantaneous phase current at ${\pi}/2$ by the theoretical formular and its computer simulation results. From the facts, we design the microcontroller-based motor position sensorless controller of optimal lead angle, which generates the excitation pulses for the closed-loop drives. The controller is consist of microcontroller which has the function of A/D converter, programmable input/output timer, and the transfer table which has the values of optimal lead angle depending on motor velocity, and ROM which has the transfer table of the values of lead angle depending on velocity of motor and the values of instantaneous phase current at ${\pi}/2$. From the design of microcontroller-based controller, we minimize the external interface circuit and obtain flexibility by changing the contents of ROM transfer tables and the control software. We confirm that the designed controller drives the bifilar-wound hybrid stepping motor is the mode of optimal lead angle by comparing the instananeous phase current experimental results and computer simulation results.

  • PDF

Lifetime test of batteries for BLE modules for site identification of vessel's crews and passengers (SIVCP) (SIVCP용 BLE 모듈의 배터리 수명시험)

  • Kwon, Hyuk-joo;Kim, Min-Gwon;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.754-759
    • /
    • 2015
  • Nowadays, short distance communication systems with low power energy (LPE) are developed for identification and monitoring of site identification of vessel crews and passengers (SIVCP). LPE communication modules, such as Bluetooth low energy (BLE) and Zigbee, are used for short distance communications with LPE. These modules enable 1:N communications and their popularity is growing since the modules can be mounted on movable objects, such as mobile devices and human body. When these modules are used, the important factor that affects their operation time and design are the capacity and size of battery. Therefore, they must be made as small as possible, and the battery should be selected to be slightly smaller than the module. In this study, we calculate the theoretical life of batteries used in SIVCP BLE modules using data sheet and discharge characteristic graph under the condition of a 1/250 transmission-ratio (TR). We thus calculate experimental life by measuring transmission current for the same TR, and low speed mode current for a 1/5000 TR and measure long-term experimental life using 1/25 TR for days. Through these experiments, we verify experimental methods for the prediction and extension of battery life that would enable us to select appropriate sizes of batteries based on vessel usage and passenger types. The selections of the module TR and battery size are important factors affecting the cost reduction of module design, the battery maintenance, and passenger convenience.

Modeling Study on a Circulatory Hollow-Fiber Membrane Absorber for $CO_{2}$ Separation (이산화탄소 분리를 위한 순환식 중공사 막흡수기에 관한 모델링 연구)

  • Chun, Myung-Suk;Lee, Kew-Ho
    • Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 1995
  • For several years lots of attempts have been made to establish the liquid membrane-based techniques for separations of gas mixtures especially containing carbon dioxide. A more effective system to separate $CO_{2}$ from flue gases, a circulatory hollow-fiber membrane absorber(HFMA) consisting of absorption and desorption modules with vacuum mode, has been considered in this study. Gas-liquid mass transfer has been modeled on a membrane module with non-wetted hollow-fibers in the laminar flow regime. The influence of an absorbent flow rate on the separation performance of the circulatory HFMA can be predicted quantitatively by obtaining the $CO_{2}$ concentration profile in a tube side. The system of $CO_{2}/N_{2}$ binary gas mixture has been studied using pure water as an(inert) absorbent. As the absorbent flow rate is increased, the permeation flux(i.e., defined as permeation rate/membrane contact area) also increases. The enhanced selectivity compared to the previous results, on the other hand, shows the decreasing behavior. It has been found obviously that the permeation flux depends on the variations of pressure in gas phase of desorption module. From an accurate comparison with the results of conventional flat sheet membrane module, the advantageous permeability of this circulatory HFMA can be clearly ascertained as expected. Our efforts to the theoretical model will provide the basic analysis on the circulatory HFMA technique for a better design and process.

  • PDF