• Title/Summary/Keyword: the w-operation

Search Result 2,469, Processing Time 0.03 seconds

Evaluation of Long Term Operation of Cross-flow Molten Carbonate Fuel Cell Stack (교차류형 100W급 용융탄산염 연료전지 스택 장기운전평가)

  • Lim, H.C.;Seol, J.H.;Ryu, C.S.;Lee, C.W.;Hong, S.A.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.2
    • /
    • pp.53-63
    • /
    • 1995
  • A 100kW class stack consisting of 10 molten carbonate fuel cells has been fabricated. Internally manifold stack has been tested for endurance. Each cell in the stack had an electrode area of $100cm^2$ and reactant gases were distributed in each cells in a cross-flow configuration. Initial and long term operation performance of the stack was investgated as a function of gas utilization using a specially designed small scale stack test facility. It was possible to have a stack with an output of more than 100W using an anode gas of 72% $H_2/18%$ $CO_2/10%H_2O$ and cathode gas of 33% $O_2/67%$ $CO_2$ and 70% Air 30% $CO_2$. The output and voltage of the stack at a current 15A($150mA/cm^2$) and gas utilization of 0.4 showed 125.8W and 8.39V respectively by elapsed time of 310 hours operation. In long term operation characteristics, the voltage drop of 52.4mV/1000hour was observed after more than 1,840 hours operation. Among the voltage drop, the OCV loss was highest than other voltage loss such as internal resistance and electrode polarization. Non uniformity of 2voltages and degradation of cell voltage in the stack was observed in according to changing the utilization rate after a long term operation. Further work for increasing the performance prolonging the life of the stack are required.

  • PDF

TWO GENERALIZATIONS OF LCM-STABLE EXTENSIONS

  • Chang, Gyu Whan;Kim, Hwankoo;Lim, Jung Wook
    • Journal of the Korean Mathematical Society
    • /
    • v.50 no.2
    • /
    • pp.393-410
    • /
    • 2013
  • Let $R{\subseteq}T$ be an extension of integral domains, X be an indeterminate over T, and R[X] and T[X] be polynomial rings. Then $R{\subseteq}T$ is said to be LCM-stable if $(aR{\cap}bR)T=aT{\cap}bT$ for all $0{\neq}a,b{\in}R$. Let $w_A$ be the so-called $w$-operation on an integral domain A. In this paper, we introduce the notions of $w(e)$- and $w$-LCM-stable extensions: (i) $R{\subseteq}T$ is $w(e)$-LCM-stable if $((aR{\cap}bR)T)_{w_T}=aT{\cap}bT$ for all $0{\neq}a,b{\in}R$ and (ii) $R{\subseteq}T$ is $w$-LCM-stable if $((aR{\cap}bR)T)_{w_R}=(aT{\cap}bT)_{w_R}$ for all $0{\neq}a,b{\in}R$. We prove that LCM-stable extensions are both $w(e)$-LCM-stable and $w$-LCM-stable. We also generalize some results on LCM-stable extensions. Among other things, we show that if R is a Krull domain (resp., $P{\upsilon}MD$), then $R{\subseteq}T$ is $w(e)$-LCM-stable (resp., $w$-LCM-stable) if and only if $R[X]{\subseteq}T[X]$ is $w(e)$-LCM-stable (resp., $w$-LCM-stable).

High Power Continuous-Wave and Graphene Q-switched Operation of Er:YAG Ceramic Lasers at ~1.6 ㎛

  • Wang, Yong;Chen, Hao;Shen, Deyuan;Zhang, Jian;Tang, Dingyuan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.5-9
    • /
    • 2013
  • We report on high-power continuous-wave operations of an Er:YAG ceramic laser in-band pumped by a cladding-pumped Er,Yb fiber laser at 1532 nm. With an output coupler of 10% transmission, the ceramic laser yielded 16.7 W of continuous-wave output at 1645 nm for 28.8 W of incident pump power, corresponding to a slope efficiency of 61.0% with respect to the incident pump power. The lasing wavelength switched to 1617 nm when output couplers of > 20% transmission were used. Up to 16.2 W of 1617 nm output was generated for 33.0 W of incident pump power, corresponding to a slope efficiency of 51.8%. Graphene Q-switched operation of Er:YAG cermic laser at 1645 nm was also demonstrated with stable pulses of 30-74 kHz repetition rates and 1.5-6.4 ${\mu}s$ pulse widths.

A Study on the Characteristic of Field Operation of Wind farm at Hangwon, Cheju (제주 행원 풍력 단지 실부하 운전 특성 연구)

  • Oh, Si-Doek;Cha, Jong-Hwan;Lee, Hyun-Joo;Huh, Jong-Cheul
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.744-750
    • /
    • 2001
  • In now a days, the concern to environment and energy saving problem is increased worldly. So many countries are developing the wind power system as clean energy system. In our country, Cheju local government has the plan of the Cheju Island wind farm and 600kW class 2 wind turbines, 660kW class 2 turbines, 225kW class 1 turbine and 750kW class 2 turbines has been operated at Hangwon. In this paper the field operation data of the wind turbines was analyzed and was compared with the characteristics & performance of each turbines. As the results, we would find the possibility of wind turbine in domestic and suggest the direction of developing technology.

  • PDF

Design and Performance Prediction of Power System in a Solar Stirling Engine for 9 kW Output (9 kW 출력용 태양열 스털링엔진 발전시스템의 설계와 성능예측)

  • Bae, Myung-Whan;Kang, Sang-Yul
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2198-2204
    • /
    • 2003
  • In order to make a match of the insufficient direct solar radiation, in this study, the target output is lowered to 9 kW smaller than 25 kW in former studies. It is also necessary to match the collector/receiver with engine/generator systems to accomplish the power level of a system. The simulation analyses of a dish solar power system with stirling engine are totally carried out to predict the system performance with the designed values. In addition, an influence of direct solar radiation on system performance and operation control is discussed in simulation. It is found that the diameter of concentrator could be made small to 8 m regardless of slope errors with 2.5 and 5.0 mrad radiation, and the operation range of mean pressure control. is wide even if the direct solar radiation is a quit low.

  • PDF

Operation Mode Development and Evaluation for Grid-Tied PMSG Wind Power System Combined with Battery Energy Storage (배터리 에너지저장이 결합된 계통연계 풍력발전시스템의 운전모드 개발 및 평가)

  • Kim, Hyun-Jun;Kim, Do-Hyun;Kim, Kyung-Tae;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • This paper describes the operation mode development for the grid-tied PMSG(permanent magnet synchronous generator) wind power system combined with a battery energy storage. The development of operation modes was carried out through simulations with PSCAD/EMTDC software and experiments with a 10kW hardware prototype. The detailed simulation models for PMSG wind power system and battery energy storage were developed using user-defined models programed with C-code. A 10kW hardware simulator was built and tested in connection with the local load and the utility power. The simulation and experimental results confirm that the grid-tied PMSG wind power system combined with battery energy storage can supply highly reliable power to the local load in various operation modes.

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF

ON CHARACTERIZATIONS OF PRÜFER v-MULTIPLICATION DOMAINS

  • Chang, Gyu Whan
    • Korean Journal of Mathematics
    • /
    • v.18 no.4
    • /
    • pp.335-342
    • /
    • 2010
  • Let D be an integral domain with quotient field K,$\mathcal{I}(D)$ be the set of nonzero ideals of D, and $w$ be the star-operation on D defined by $I_w=\{x{\in}K{\mid}xJ{\subseteq}I$ for some $J{\in}\mathcal{I}(D)$ such that J is finitely generated and $J^{-1}=D\}$. The D is called a Pr$\ddot{u}$fer $v$-multiplication domain if $(II^{-1})_w=D$ for all nonzero finitely generated ideals I of D. In this paper, we show that D is a Pr$\ddot{u}$fer $v$-multiplication domain if and only if $(A{\cap}(B+C))_w=((A{\cap}B)+(A{\cap}C))_w$ for all $A,B,C{\in}\mathcal{I}(D)$, if and only if $(A(B{\cap}C))_w=(AB{\cap}AC)_w$ for all $A,B,C{\in}\mathcal{I}(D)$, if and only if $((A+B)(A{\cap}B))_w=(AB)_w$ for all $A,B{\in}\mathcal{I}(D)$, if and only if $((A+B):C)_w=((A:C)+(B:C))_w$ for all $A,B,C{\in}\mathcal{I}(D)$ with C finitely generated, if and only if $((a:b)+(b:a))_w=D$ for all nonzero $a,b{\in}D$, if and only if $(A:(B{\cap}C))_w=((A:B)+(A:C))_w$ for all $A,B,C{\in}\mathcal{I}(D)$ with B, C finitely generated.

Multiple Brillouin Stokes Generation Utilizing a Linear Cavity Erbium-Doped Fiber Laser

  • AL-Mansoori, Mohammed Haydar;Noordin, Nor Kamariah;Saripan, M. Iqbal;Mahdi, Mohd Adzir
    • Journal of Communications and Networks
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 2008
  • This paper reports the design of a multiwavelength fiber laser source that utilizes a linear cavity of hybrid Brillouin/Erbium fiber laser (BEFL). The output power, threshold power and free running cavity modes were investigated against the pump powers. The structure exhibited low threshold operation of 4 mW at 2.3 mW injected Brillouin pump power. The optimization of Brillouin pump wavelength, power and Erbium gain led to a maximum possible number of channels generated. Simultaneous and stable operation of 21 channels with 10.88 GHz channels spacing were obtained from this architecture at 1 mW injected Brillouin pump power and 90 m W Erbium doped fiber pump power in the 1555 nm region.

Operation Characteristics of 100W Class Molten Carbonate Fuel Cell Stack (100W 급 용융탄산염 연료전지 스택운전특성)

  • Lim, Hee-Chun;Lee, Chang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.94-96
    • /
    • 1994
  • To develop the 2kw class MCFC stack, preliminarly 3 cell and 10 cell stack having a $100cm^2$ effective electrode area were fabricated and tested. These stacks showed 30 W and 100 W of output respectively and average cell voltage of 0.734V at $150mA/cm^2$. The stack performance decreased with the increase of fuel utilization rate. In durability test of 10 cell stack, the performance was sharply decreased at the rate of 180mV/1000Hr during 720hours operation time.

  • PDF