• Title/Summary/Keyword: the w-operation

Search Result 2,469, Processing Time 0.029 seconds

The operation algorithm of the 1kW fuel cell-battery hybrid power system (1kW급 연료전지-배터리 복합 전원 시스템의 운용 알고리즘 구현)

  • Park, Jinju;Chae, Suyong;Song, Yujin;Han, Soobin
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.95-96
    • /
    • 2013
  • In this paper, an operation algorithm for the fuel cell-battery hybrid power system is proposed. As the output current slope of the fuel cell is normally limited to protect the fuel cells' defection, efficient power distribution algorithm between the fuel cell and battery is very important for the successful hybrid control operation. For the experimentation, a 1kW dc-dc converter with 500W fuel cell stack and 1kWh Li-polymer battery is implemented.

  • PDF

Development of 50W Solid Oxide Fuel Cell system (50W 고체 산화물 연료전지 시스템 구축)

  • Jee, Young-Seok;Lah, Se-Yun;Cho, Goo-Young;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.311-314
    • /
    • 2009
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells, We evaluated hydrogen fed SOFC 50W system theoretically and got the results about the operating condition range from the comparison of the power efficiency, exhaust gas temperature, required heat for maintaining the operation temperature and operation time.

  • PDF

Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater (심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석)

  • JUNG, H.;HWANG, S.W.;LEE, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

The development of High efficiency fuel processor for technical independence 5kW class fuel cell system (기술자립형 5kW 연료전지 시스템 구축을 위한 고효율 연료변환기 개발)

  • Lee, Soojae;Choi, Daehyun;Jun, Heekwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.123.2-123.2
    • /
    • 2010
  • Fuel Cell cogeneration system is a promising technology for generating electricity and heat with high efficiency of low pollutant emission. We have been developed 5kW class fuel cell cogeneration system for commercial and residential application. The fuel processor is a crucial part of producing hydrogen from the fossil fuels such as LNG and LPG. The 5kW class high efficiency fuel processor consists of steam reformer, CO shift converter, CO preferential oxidation(PrOx) reactor, burner and heat exchanger. The one-stage CO shift converter process using a metal oxide catalyst was adopted. The efficiency of 5 kW class fuel processor shows 75% based on LHV. In addition, for the purpose of continuous operation with load fluctuations in the commercial system for residential use, load change of fuel processor was tested. Efficiency of 30%, 50%, 70% and 100% load shows 75%, 75%, 73% and 72%(LHV), respectively. Also, during the load change conditions, the product gas composition was stable and the outlet CO concentration was below 5 ppm. The Fuel processor operation was carried out in residential fuel cell cogeneration system with fuel cell stack under dynamic conditions. The 5kW class fuel processor have been evaluated for long-term durability and reliability test including with improvement in optimal operation logic.

  • PDF

Research on the Actual Condition of Rotary Tilling & Rotary Power Requirement in the Central Area (중부지방에서의 로터리 경운작업 실태조사 및 경운부하)

  • Myung, Byung-Su;Lee, Hyun-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.2
    • /
    • pp.79-83
    • /
    • 2009
  • In this study, actual state of operation of rotary tillage was surveyed in the central part of Korea which includes 29 rural community around Asan city, Choongnam principal. 29 heads of the village and 44 farmers were surveyed at the field with a questionnaire on the operation of rotary tillage with farm tractors. Power requirement of rotary tillage operation was measured at the field of each farmers during rotary tilling operation in the central part of Korea. Summaries of this study are summarized as follows. 1) Operations of tillage and land preparation were found to be carried out with farm tractors by 98 percents which are results of the survey on 29 heads of the village and 44 farmers. 2) More than half of the farms had tractors with horsepower more than 38 kW which states that most tractors were supplied in middle and large size. 3) The case of applying secondary tillage after the first primary tillage were 79 percent among the most of operations of tillage and field preparation. Rotary tillage were carried out on the most of wet paddy fields and only 14 percent of dry fields were cultivated with rotary tillage. 4) 63.6 percent of farm tractors were surveyed to meet the recommended field capacity on tillage operation by the government which were ranged from 15.1 to 34.9 ha. And the field capacity of these farm tractors were greater than that of annual total area of operation field, 13.2ha (data from Information of agricultural machinery, National agricultural products quality service, Korea), which states the utilization of agricultural machinery was high in the area surveyed. 5) 46 percent of farmers changed the blade of rotary implement when they used it over the field capacity of rotary blade of 33 ha which is the area of field for rotary operation per a blade change. 55 percent of farmers changed the rotary blade more than once per two years. 6) The required power for rotary operation of each farm tractors were measured as 17.206 kW at untilled paddy field and 34.989 kW at untilled dry field on the average, respectively. The required power for rotary operation was measured as 28.248 kW on the average at the paddy field which had been plowed once and 28.015 at the paddy field that had rotary tillage operation. Untilled dry field showed the highest value of the required power for rotary operation.

  • PDF

Development of a Collecting System for Jujube Harvester (대추수확기의 집과시스템 개발에 관한 연구)

  • Lee, S.W.;Kim, D.H.;Lee, C.K.;Seo, S.W.;Huh, Y.K.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.500-505
    • /
    • 2006
  • Jujube is one of korean most favorite fruits. Harvesting operations of the jujube farming, however, completely depend on hand labor. Especially, collecting operation requires about three times of hand labor compared with separate operation by impacting or shaking of twigs in the hand-harvesting system of jujube fruits. Consequently, jujube farmers sincerely demand the mechanization of the collecting operation of jujube fruits in the harvesting operation. A new collecting system was designed and constructed five parts-collecting pad, guide ring system, sorting system, frame with driving system, and handle with operation levers, which performed collecting operation of jujube fruits without missing fruits in five part functions, however, an extra future more deliberate study would need how to handle conveniently the collecting pad of the prototype in the narrow space of row of the jujube farm.

A Design of Advanced Distribution Management System Based on IT/OT Convergence (IT/OT Convergence 기반의 Advanced Distribution Management System의 설계)

  • Lim, Il-Hyung;Lee, Seung-Joo;Park, Jong-Ho;Shin, Yong-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.753-759
    • /
    • 2016
  • Power automation system to operate power distribution systems can be distinguished by distribution SCADA with remote monitoring and control; and distribution automation system with basic functions such as service restoration to the distribution SCADA; and distribution management system which is operated by various applications in order to enhance distribution system operation performance based on the distribution automation system. In the technological change, a technical boundary of information technology (IT) and operation technology (OT) is being blurred by that new concepts such as interoperability. In addtion, IT/OT convergence has been proposed by the improvement of ICT and power system technology. At the viewpoint, advanced distribution management system (ADMS) to have the new concepts and to increase distribution system operation efficiency through global information and functions from the other systems has been proposed. In order to implement the ADMS, IT and OT have to be employed together on the ADMS; and the concept-based IT/OT convergence concept has been presented. Therefore, this paper introduces ADMS and IT/OT convergence and proposes a design of IT/OT convergence based ADMS system design with configurations and functions.

System Development of a 100 kW Molten Carbonate Fuel Cell III (System Control and Operation Mode) (100 kW급 용융탄산염 연료전지 시스템 개발 III (시스템 제어 및 운전모드))

  • Lim, Hee-Chun;Ahn, Kyo-Sang;Seo, Hai-Kyung;Eom, Yeong-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1350-1352
    • /
    • 2003
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately two substacks with 90 cells are required to generate 100 kW at a current density of $125\;mA/cm^2$ with $6000\;cm^2$ of cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. To operate and evaluate the MCFC system, control and measurement system and operation mode are designed before 100 MCFC system construction. In system control schematics, OS, PLC and MMI were consisted and have roles for MCFC system control. For operation of 100 kW MCFC system, NS, PS PR mode were considerated step by step and simulated.

  • PDF

1.5 V Sub-mW CMOS Interface Circuit for Capacitive Sensor Applications in Ubiquitous Sensor Networks

  • Lee, Sung-Sik;Lee, Ah-Ra;Je, Chang-Han;Lee, Myung-Lae;Hwang, Gunn;Choi, Chang-Auck
    • ETRI Journal
    • /
    • v.30 no.5
    • /
    • pp.644-652
    • /
    • 2008
  • In this paper, a low-power CMOS interface circuit is designed and demonstrated for capacitive sensor applications, which is implemented using a standard 0.35-${\mu}m$ CMOS logic technology. To achieve low-power performance, the low-voltage capacitance-to-pulse-width converter based on a self-reset operation at a supply voltage of 1.5 V is designed and incorporated into a new interface circuit. Moreover, the external pulse signal for the reset operation is made unnecessary by the employment of the self-reset operation. At a low supply voltage of 1.5 V, the new circuit requires a total power consumption of 0.47 mW with ultra-low power dissipation of 157 ${\mu}W$ of the interface-circuit core. These results demonstrate that the new interface circuit with self-reset operation successfully reduces power consumption. In addition, a prototype wireless sensor-module with the proposed circuit is successfully implemented for practical applications. Consequently, the new CMOS interface circuit can be used for the sensor applications in ubiquitous sensor networks, where low-power performance is essential.

  • PDF

Real operation of 2 kW class reverse-Brayton refrigeration system with using scroll compressor package

  • Kim, Hyobong;Yeom, Hankil;Choo, Sangyoon;Kim, Jongwoo;Park, Jiho;In, Sehwan;Hong, Yong-Ju;Park, Seong-Je;Ko, Junseok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.40-44
    • /
    • 2020
  • This paper describes the real operation of 2 kW class reverse-Brayton refrigeration system with neon as a working fluid. The refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa at low and high pressure side, respectively. Compressor package consists of several helium scroll compressors witch are originally used for driving GM cryocooler. Three segments of plate heat exchanger are adopted to cover the wide temperature range and the refrigeration power is produced by turbo expander. The developed refrigeration system is successfully operated at its target temperature of 77 K. In experiments, all parameters such as pressure, temperature, mass flow rate and valve opening are measured to investigate characteristics during cool-down process and normal state. The difference between design and real operation is discussed with measured experimental data. At normal state of 77 K operation, the developed reverse-Brayton refrigeration system shows 1.83 kW at 68.2 K of cold-end temperature.