• Title/Summary/Keyword: the w-operation

Search Result 2,473, Processing Time 0.032 seconds

Optimum Size Selection and Machinery Costs Analysis for Farm Machinery Systems - Programming for Personal Computer - (농기계(農機械) 투입모형(投入模型) 설정(設定) 및 기계이용(機械利用) 비용(費用) 분석연구(分析硏究) - PC용(用) 프로그램 개발(開發) -)

  • Lee, W.Y.;Kim, S.R.;Jung, D.H.;Chang, D.I.;Lee, D.H.;Kim, Y.H.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.4
    • /
    • pp.384-398
    • /
    • 1991
  • A computer program was developed to select the optimum size of farm machine and analyze its operation costs according to various farming conditions. It was written in FORTRAN 77 and BASIC languages and can be run on any personal computer having Korean Standard Complete Type and Korean Language Code. The program was developed as a user-friendly type so that users can carry out easily the costs analysis for the whole farm work or respective operation in rice production, and for plowing, rotarying and pest controlling in upland. The program can analyze simultaneously three different machines in plowing & rotarying and two machines in transplanting, pest controlling and harvesting operations. The input data are the sizes of arable lands, possible working days and number of laborers during the opimum working period, and custom rates varying depending on regions and individual farming conditions. We can find out the results such as the selected optimum combination farm machines, the overs and shorts of working days relative to the planned working period, capacities of the machines, break-even points by custom rate, fixed costs for a month, and utilization costs in a hectare.

  • PDF

Fabrication and Performance of Anode-Supported Flat Tubular Solid Oxide Fuel Cell Unit Bundle (연료극 지지체식 평관형 고체산화물 연료전지 단위 번들의 제조 및 성능)

  • Lim, Tak-Hyoung;Kim, Gwan-Yeong;Park, Jae-Layng;Lee, Seung-Bok;Shin, Dong-Ryul;Song, Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.283-287
    • /
    • 2007
  • KIER has been developing the anode-supported flat tubular solid oxide fuel cell unit bundle for the intermediate temperature($700{\sim}800^{\circ}C$) operation. Anode-supported flat tubular cells have Ni/YSZ cermet anode support, 8 moi.% $Y_2O_3$ stabilized $ZrO_2(YSZ)$ thin electrolyte, and cathode multi-layer composed of Sr-doped $LaSrMnO_3(LSM)$, LSM-YSZ composite, and $LaSrCoFeO_3(LSCF)$. The prepared anode-supported flat tubular cell was joined with ferritic stainless steel cap by induction brazing process. Current collection for the cathode was achieved by winding Ag wire and $La_{0.6}Sr_{0.4}CoO_3(LSCo)$ paste, while current collection for the anode was achieved by using Ni wire and felt. For making stack, the prepared anode-supported flat tubular cells with effective electrode area of $90\;cm^2$ connected in series with 12 unit bundles, in which unit bundle consists of two cells connected in parallel. The performance of unit bundle in 3% humidified $H_2$ and air at $800^{\circ}C$ shows maximum power density of $0.39\;W/cm^2$ (@ 0.7V). Through these experiments, we obtained basic technology of the anode-supported flat tubular cell and established the proprietary concept of the anode-supported flat tubular cell unit bundle.

DO concentration assessment on the micro-bubble generator operation in agricultural lake (농업용 호소의 마이크로버블 현장적용에 따른 DO 농도 평가)

  • Choi, Sunhwa;Lee, Seungheon;Jang, Kyusang;Lee, Jinkyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.431-431
    • /
    • 2016
  • J 호소는 1942년도에 충청남도 아산시 선장면에 설치된 농업용 저수지로서, 현재 COD, TN, TP 모두 등급외의 수질상태를 보이고 있다. J 호소 상류 유역은 축산농가가 다수 위치하고 있으며, 설치된 지 70년이 지난 노후화된 저수지로 고농도의 오염물질 유입뿐만 아니라 호소 바닥의 오염 퇴적물에 의한 내부 부하가 중요한 수질오염원이 되고 있다. 호소의 수질은 현재 COD 10.6~16.5 mg/L, Chl-a $75mg/m^3$ 이상으로 수질오염도가 매우 높으며, 특히 늦봄에서 초가을까지 외기온도 상승 및 저수율 저하와 함께 부영양화 증가, 녹조 대발생 등으로 호 내 물고기 대량 폐사 및 악취발생 등으로 민원이 다수 발생하고 있다. 이러한 현상의 직접적인 원인은 수중의 DO 농도 결핍이며, 따라서 수중의 DO 농도를 일정수준 이상으로 유지시켜 주는 것은 호소 수질관리를 위해 매우 필요하다고 판단된다. 본 연구에서는 공기 중의 산소를 호소 수체에 포기시켜 주는 마이크로버블 발생장치를 J 저수지에 설치하여 수체의 DO 농도 변화 등을 분석하였고, 본 연구결과는 농업용 호소의 수질개선을 위한 기술개발 및 계획수립의 기초자료로 활용하고자 하였다. 마이크로버블 포기장치는 수심이 약 4m 되는 저수지 제방 근처에 100m 간격으로 총 3지점에 설치하였다. 버블 발생기는 기액 2상류 선회형 마이크로 버블 발생장치로 3지점에 각 1set(1set에 3기로 구성)씩 구성하여 저수지 바닥 층에서 상부로 1m 떨어진 지점에 고정식으로 설치하였다. 총 공기흡입량은 380 LPM이며, 사용동력은 12.2kW를 사용하였다. 마이크로 버블 포기장치 설치 후 호 내 DO 농도 변화를 평가하기 위하여 호소 전체에 18개 지점을 선정하여 수심 50cm 간격으로 DO 농도를 측정하였다. 가동 전에는 DO 평균농도가 표층에서는 약 7.7mg/L로 나타났고, 수심에 따라 거의 수직적으로 감소하여 바닥층에서는 약 0.2mg/L로 거의 무산소 상태를 보이고 있었다. 마이크로 버블 가동 2주 후에는 수심 3m까지의 모든 수층에서 DO 농도가 약 6.0mg/L 이상을 보였고, 바닥층에서는 DO 약 3.4mg/의 농도를 나타내었다. 가동 3주 후에도 2주 후와 비슷한 수치를 보이고 있었으나 가동 4주가 지나면서부터는 호소 바닥층(수심 3.5m)에서도 DO 농도가 7.0mg/L 이상의 높은 농도를 유지하는 것으로 조사되었다. 호소 저층에서 호기성 상태의 지속적 유지는 퇴적 오염물질이 수층으로 용출되는 것을 예방할 수 있으므로 마이크로버블을 잘 활용하면 호소의 악취제거 및 수질개선에 많은 도움이 될 것으로 판단된다.

  • PDF

Biliary Atresia in Korea - A Survey by the Korean Association of Pediatric Surgeons - (담도폐색증 - 대한소아외과학회회원 대상 전국조사 -)

  • Choi, Kum-Ja;Kim, S.C.;Kim, S.K.;Kim, W.K.;Kim, I.K.;Kim, J.E.;Kim, J.C.;Kim, H.Y.;Kim, H.H.;Park, K.W.;Park, W.H.;Song, Y.T.;Oh, S.M.;Lee, D.S.;Lee, M.D.;Lee, S.K.;Lee, S.C.;Jhung, S.Y.;Jhung, S.E.;P.M., Jung;S.O., Choi;Choi, S.H.;Han, S.J.;Huh, Y.S.;Hong, C.;Hwbang, E.H.
    • Advances in pediatric surgery
    • /
    • v.8 no.2
    • /
    • pp.143-155
    • /
    • 2002
  • A survey on biliary atresia was made among 26 members of the Korean Association of Pediatric Surgeons. The members were required to complete a questionnaire and a case registration form for each patient during the twentyone-year period of 1980-2000. Three hundred and eighty patients were registered from 18 institutions. The average number of patients per surgeon was one to two every year. The male to female ratio was 1:1.3. The age of patients on diagnosis with biliary atresia was on average $65.4{\pm} 36.2$ days old. The national distribution was 32.8% in Seoul, 25.3% in Gyoungki-Do, 21.6% in Gyoungsang-Do, 9.27% in Choongchung-Do, etc. in order. The most common clinical presentation was jaundice (98.4%) and change of stool color (86.2%) was second. Two hundred eighty (74.7%) of 375 patients were operated by 80 days of age. Three hundred thirty six (9 1.9%) of 366 patients were operated on by the original Kasai procedure, and 305 (84.3%) of 362 patients were observed by bile-drainage postoperatively. The overall postoperative complication rate was 18.5% and the overall postoperative mortality rate was 6.8%. The associated anomalies were observed in 72 cases (22.5%). One hundred ninty five (64.7%) of 302 patients have been alive in follow-up and 49 (25.1%) have survived over 5 years without problem after operation. Ascending cholangitis, varices and ascites affected survival significantly, and the important long-term prognostic factor was the occurrence of complications.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

A Study on the Relationship of Learning, Innovation Capability and Innovation Outcome (학습, 혁신역량과 혁신성과 간의 관계에 관한 연구)

  • Kim, Kui-Won
    • Journal of Korea Technology Innovation Society
    • /
    • v.17 no.2
    • /
    • pp.380-420
    • /
    • 2014
  • We increasingly see the importance of employees acquiring enough expert capability or innovation capability to prepare for ever growing uncertainties in their operation domains. However, despite the above circumstances, there have not been an enough number of researches on how operational input components for employees' innovation outcome, innovation activities such as acquisition, exercise and promotion effort of employee's innovation capability, and their resulting innovation outcome interact with each other. This trend is believed to have been resulted because most of the current researches on innovation focus on the units of country, industry and corporate entity levels but not on an individual corporation's innovation input components, innovation outcome and innovation activities themselves. Therefore, this study intends to avoid the currently prevalent study frames and views on innovation and focus more on the strategic policies required for the enhancement of an organization's innovation capabilities by quantitatively analyzing employees' innovation outcomes and their most suggested relevant innovation activities. The research model that this study deploys offers both linear and structural model on the trio of learning, innovation capability and innovation outcome, and then suggests the 4 relevant hypotheses which are quantitatively tested and analyzed as follows: Hypothesis 1] The different levels of innovation capability produce different innovation outcomes (accepted, p-value = 0.000<0.05). Hypothesis 2] The different amounts of learning time produce different innovation capabilities (rejected, p-value = 0.199, 0.220>0.05). Hypothesis 3] The different amounts of learning time produce different innovation outcomes. (accepted, p-value = 0.000<0.05). Hypothesis 4] the innovation capability acts as a significant parameter in the relationship of the amount of learning time and innovation outcome (structural modeling test). This structural model after the t-tests on Hypotheses 1 through 4 proves that irregular on-the-job training and e-learning directly affects the learning time factor while job experience level, employment period and capability level measurement also directly impacts on the innovation capability factor. Also this hypothesis gets further supported by the fact that the patent time absolutely and directly affects the innovation capability factor rather than the learning time factor. Through the 4 hypotheses, this study proposes as measures to maximize an organization's innovation outcome. firstly, frequent irregular on-the-job training that is based on an e-learning system, secondly, efficient innovation management of employment period, job skill levels, etc through active sponsorship and energization community of practice (CoP) as a form of irregular learning, and thirdly a model of Yί=f(e, i, s, t, w)+${\varepsilon}$ as an innovation outcome function that is soundly based on a smart system of capability level measurement. The innovation outcome function is what this study considers the most appropriate and important reference model.

The Simulation for the Organization of Fishing Vessel Control System in Fishing Ground (어장에 있어서의 어선관제시스템 구축을 위한 모의실험)

  • 배문기;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.175-185
    • /
    • 2000
  • This paper described on a basic study to organize fishing vessel control system in order to control efficiently fishing vessel in Korean offshore. It was digitalized ARPA image on the fishing processing of a fleet of purse seiner in conducting fishing operation at Cheju offshore in Korea as a digital camera and then simulated by used VTMS. Futhermore, it was investigated on the application of FVTMS which can control efficiently fishing vessels in fishing ground. The results obtained were as follows ; (1) It was taken 16 minutes and 35 minutes to casting and hauling net in fishing processing respectively. The length of rope pulled by scout boat was 200m, tactical diameter in casting net was 340.8m, turning speed was 6kts as well. (2) The processing of casting and hauling net was moved to SW, NE as results of simulation when the current direction and speed set into NE, 2kts and SW, 2kts respectively. Such as these results suggest that can predict to control the fishing vessel previously with information of fishing ground, fishery and ship's maneuvering, etc. (3) The control range of VTMS radar used in simulation was about 16 miles. Although converting from a radar of the control vessel to another one, it was continuously acquired for the vector and the target data. The optimum control position could be determined by measuring and analyzing to distance and direction between the control vessel and the fleet of fishing vessel. (4) The FVTMS(fishing vessel traffic management services) model was suggested that fishing vessels received fishing conditions and safety navigation information can operate safely and efficiently.

  • PDF

A Comparison on the Characteristics of Cerebrovascular Disease Patients Admitted to Some Western and Oriental Hospitals (일부 양·한방 병원에 입원한 뇌혈관질환 환자의 특성 비교)

  • Yu, Dae-Jin;Ryu, So-Yeon;Park, Jong;Kim, Ki-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.1
    • /
    • pp.65-79
    • /
    • 2001
  • Cerebrovascular disease(CVD) is one of the major causes of death in Korea as well as most countries in the world and the disease gives great burden to humans socio-economically due to its high fatality and common occurrence of disability as the sequelae. This study was performed to investigate the utilization of western hospital(WH) or oriental hospital(OH) due to CVD and compare the type and the clinical characteristics of patients with CVD between WH and OH located in Kwangju City, Chonnam Province and Chonbuk Province. We reviewed the medical records of 1,070 patients who were discharged from 12 WIT and 6 OH from January to March, 2000 and confirmed for the diagnosis of CVD. Fifty-one percent of the subjects were treated at WH and forty-nine percent at OH. Females were more prevalent than males. As well, the most common age group among these subjects was found to be 70 years and older. About 92% in W~H and 80% in OH received brain imaging diagnostic procedures such as CT or MRI. The cerebral infarction was the most common type of CVD when compared by the kind of utilized hospitals, sex, age group except patient Group who was treated at WH and whose age was lower than 50 years old. The cerebral hemorrhage was more frequent than cerebral infarction among this group. The proportion of cerebral hemorrhage was decreasing and that of cerebral infarction was increasing with age. The most common clinical manifestations of undetermined type of CVD was paralysis of lower extremity in WIT and paralysis of upper extremity in OH. In cerebral hemorrhage loss of consciousness in WIT and dysarthria in OH were most frequently manifested, while in the case of cerebral infarction hemiplegia in WIT and dysarthria in OH were the most common complaints. The interval from the onset of disease to admission to the hospital was 5.5 days in WH arid 31.4 days in OH and the difference was statistically significant. Average admission duration of patients at OH was longer than WH, but it was not statistically significant. In conclusion these results suggest that the effort for systematic and efficient management of CVD patients was necessary for close co-operation and role arrangement between WH and OH considering the positive and negative points of western and oriental medicines.

  • PDF

Treatment of Garbage Leachate with Two-phase Anaerobic Digestion Coupled with Ultra Filtration (막결합형 2상 혐기성 소화 공정을 이용한 음식물 탈리액 처리)

  • Lee, Eun-Young;Kim, Hyung-Kuk;Giang, Luu Thi Thuy;Bae, Jae-Ho;Bae, Young-Shin;Won, Jong-Choul;Lee, Jae-Hoon;Park, Seung-Kyun;Cho, Yong-Wan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.997-1006
    • /
    • 2009
  • Organic removal efficiency and methane production rate, a feasibility of power generation from biogas, and the optimum conditions for membrane operation were evaluated for the pilot scale (5 tons/day) two-phase anaerobic digestion coupled with ultra filtration (TPADUF) system fed with garbage leachate. The TPADUF system is consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. When garbage leachate with 150 g/L of TCOD was fed to the TPADUF up to organic loading rate (OLR) of 11.1 g COD/L/d, the effluent TCOD was lower than 6 g/L and the average removal efficiencies of TCOD and SCOD were higher than 95%. The methane composition of the gas was 65%, and the methane yield was 39 $m^3/m^3$ garbage leachatefed, 260 $m^3$/tons $COD_{added}$, or 270 $m^3$/tons $COD_{removed}$, even there was some gas leak. The power production per consumed gas was 0.96 kWh/$m^3$ gas or 1.49 kWh/$m^3$ methane. This lower power production efficiency mainly due to the small capacity of gas engine (15 kW class). The membrane was operated at the average flux of 10 L/$m^2$/hr. When the flux decreased, washing with water and chemical (NaOCl) was conducted to restore the flux. In the TPADUF system, optimum pH could be maintained without alkali addition by recycling the membrane concentrate or mixed liquor of the methanogenic digester to the acidogenic reactor. Also, partial production of methane in the acidogenic reactor had a positive effect on lowering the OLR of the methanogenic reactor.

Experimental Study on the Effects of Ovariectomy and Estrogen on the Bone Pattern of Mandible in Rats (난소적출과 에스트로젠 투여가 백서의 하악골 구조에 미치는 영향)

  • Lee, Hyung-Soon;Hong, Sung-Gyu;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.83-94
    • /
    • 1999
  • The purpose of this study was to evaluate the changes of cancellous and cortical bone and the effect of estrogen in ovariectomized rats. Fifty female rats, 250gm in body weight, were divided into three groups : ovariectomized group(OVE), ovariectomized and estrogen-injected group(OVE-EST), and sham operated and estrogen-injected group(EST). Bilateral ovariectomy was performed at the onset of the experiment. In OVE-EST group and EST group, estrogen was injected $50{\mu}g/kg$ B.W. every other days from 3 weeks after surgery to sacrifice. Each five rats were sacrificed after 5, 6, 7 weeks. One side of mandibular body was radiographed with a soft x-ray apparatus(Hitex Co., Ltd., Japan). Thereafter the obtained microradiographs were used for the morphometric analysis using a Image analyzer. The morphometric analysis was perforrmed for parameters such as total bone area, cortex bone area and medullary bone area. The other side of the mandibular bone was decalcified and embedded in paraffin as using a general method. The specimens were sectioned and stained with Mallory's anilline blue and observed light microscopically. The results were as follows. 1 In all groups, the proportion of cortex to total bone area was not significantly different. 2. In ovariectomized(OVE) group, the proportion of marrow cavity to medullary bone area increased significantly from 5 to 7 weeks(p<0.05). In ovariectomized and estrogen-injected(OVE-EST) group, it decreased significantly at 7 weeks, and in estrogen-injected(EST) group, it decreased significantly from 6 weeks(p<0.05). 3. Microradiogram and histopathologic findings revealed that marrow cavity was enlarged and osteoclasts were observed around irregular bone surface in OVE group. In OVE-EST group, the size of marrow cavity at 7 weeks was similar to that of control group. In EST group, as dense trabecular bone increased from 5 to 7 weeks, marrow cavity decreased.

  • PDF