• 제목/요약/키워드: the standard of reference

검색결과 2,150건 처리시간 0.033초

H.264/AVC용 고속 다중 참조영상 움직임 예측 알고리즘 (Fast Multi-Frame Motion Estimation Algorithm for H.264 Video Coding)

  • 변주원;최진하;김재석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.795-796
    • /
    • 2008
  • H.264/AVC standard adopts multiple reference frames for motion estimation. This method improves coding efficiency, but it increases complexity of encoder. In this paper, we propose a algorithm that reduces the search range by using the correlation of motion vector. Consequently, motion estimation processing time is 47.5% when compared with standard of five reference frames, and SNR and bitrate are better than that of standard of three multi reference frames.

  • PDF

Measurements of the rheological properties of standard reference material 2490 using an in-line micro-Fourier rheometer

  • Smith R. S.;Glasscock J. A.
    • Korea-Australia Rheology Journal
    • /
    • 제16권4호
    • /
    • pp.169-173
    • /
    • 2004
  • The control of the rheological properties of a fluid during processing is important and can determine the efficiency of the production in addition to the performance of the final product. The vast majority of process fluids are viscoelastic, hence an instrument that measures both the viscous and elastic properties of the material during processing would be of great practical use. However, most in-line instruments commercially available to date are only capable of measuring viscosity at a single shear rate. An in-line rheometer that measures both the viscous and elastic properties of fluids over a wide range of shear rates simultaneously has been described in a previous publication (Glasscock et at., 2003) in which the results of measurements on flowing sunflower oil were presented. Before this instrument can be used in an industrial situation, it must be demonstrated that the generated results are the same as, or bear some fixed relationship to, the results obtained by conventional off-line rheometers. To this end, the present investigation describes the measurements of a standard reference fluid, polyisobutylene dissolved in 2,6,10,14-tetramethylpentadecane, labelled SRM2490 by the National Institute of Standards and Technology (NIST) in the USA. The results obtained using the in-line rheometer show remarkably good correlation for viscosity, using a modified Cox­Merz rule, with the results supplied with the reference material from NIST.

약물검사 키트의 분석 민감도에 대한 연구 (A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry)

  • 장상우;김남용;이희경;김현정;이윤정;진옥배;김미경
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

참조표준 등록을 위한 천문역법 자료 분석 (ANALYSIS OF ASTRONOMICAL ALMANAC DATA FOR NATIONAL STANDARD REFERENCE DATA)

  • 양홍진;안영숙;이기원
    • 천문학논총
    • /
    • 제23권2호
    • /
    • pp.53-63
    • /
    • 2008
  • Korea Astronomy and Space Science Institute (KASI), direct decendant of Korea National Astronomy Observatory, has been publishing Korean Astronomical Almanac since in 1976. The almanac contains essential data in our daily lives such as the times of sunrise, sunset, moonrise, and moonset, conversion tables between luni-solar and solar calendars, and so forth. So, we are planning to register Korean astronomical almanac data for national Standard Reference Data(SRD), which is a scientific/technical data whose the reliablity and the accuracy are authorized by scientific analysis and evalution. To be certificated as national SRD, reference data has to satisfy several criteria such as traceability, consistency, uncertainty, and so on. Based on similarity among calculation processes, we classified astronomical almanac data into three groups: Class I, II, and III. We are planning to register them for national SRD in consecutive order. In this study, we analyzed Class I data which is aimed to register in 2009, and presented the results. Firstly, we found that the traceability and the consistency can be ensured by the usage of NASA/JPL DE405 ephemeris and by the comparsion with international data, respectively. To evaluate uncertainty in Class I data, we solved the mathematical model and determined the factors influencing the calculations. As a result, we found that the atmospheric refraction is the main factor and leads to a variation of ${\pm}16$ seconds in the times of sunrise and sunset. We also briefly review the histories of astronomical almanac data and of standard reference data in Korea.

WHO/WPRO 표준 경혈 위치의 이해 : 일반기준을 중심으로 (Understanding of the WHO Standard Acupuncture Point Locations in the Western Pacific Region : General Guidelines)

  • 구성태;김용석;임윤경;최선미;강성길
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.1-11
    • /
    • 2010
  • Objectives : The aim of the study is to explain the general guidelines of the WHO standard acupuncture point locations (APLs). Understanding the general guidelines will enable experts to make the clear use of the standard APL for education, research and practice. Methods : In the beginning of development of the standard APL, experts made general guidelines to draw mutual agreements of the three nations (Korea, China, and Japan) on the standard APL. The guidelines include point locating methods, syntax of descriptive sentences, landmarks on body surface, reference acupuncture points, usage of anatomical terminology, and proportional bone measurements. Results : We found that there are some considerable problems in practical use of the APLs due to the strict application of anatomical terms, even on accessory phrases such as region of body in the sentence of each description. Conclusions : We hope that the study helps readers expand the understanding of the newly developed standard APLs resulting from increased application of acupuncture points. Also, it would be a reference to revise the WHO standard APLs in the future.

Nondestructive Prediction of Fatty Acid Composition in Sesame Seeds by Near Infrared Reflectance Spectroscopy

  • Kim, Kwan-Su;Park, Si-Hyung;Choung, Myoung-Gun;Kim, Sun-Lim
    • 한국작물학회지
    • /
    • 제51권spc1호
    • /
    • pp.304-309
    • /
    • 2006
  • Near infrared reflectance spectroscopy (NIRS) was used to develop a rapid and nondestructive method for the determination of fatty acid composition in sesame (Sesamum indicum L.) seed oil. A total of ninety-three samples of intact seeds were scanned in the reflectance mode of a scanning monochromator, and reference values for fatty acid composition were measured by gas-liquid chromatography. Calibration equations were developed using modified partial least square regression with internal cross validation (n=63). The equations obtained had low standard errors of cross-validation and moderate $R^2$ (coefficient of determination in calibration). Prediction of an external validation set (n=30) showed significant correlation between reference values and NIRS estimated values based on the SEP (standard error of prediction), $r^2$ (coefficient of determination in prediction) and the ratio of standard deviation (SD) of reference data to SEP. The models developed in this study had relatively higher values (more than 2.0) of SD/SEP(C) for oleic and linoleic acid, having good correlation between reference and NIRS estimate. The results indicated that NIRS, a nondestructive screening method could be used to rapidly determine fatty acid composition in sesame seeds in the breeding programs for high quality sesame oil.

Standard Implementation for Privacy Framework and Privacy Reference Architecture for Protecting Personally Identifiable Information

  • Shin, Yong-Nyuo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제11권3호
    • /
    • pp.197-203
    • /
    • 2011
  • Personal Identifiable Information (PII) is considered information that identifies or can be used to identify, contact, or locate a person to whom such information pertains or that is or might be linked to a natural person directly or indirectly. In order to recognize such data processed within information and communication technologies such as PII, it should be determined at which stage the information identifies, or can be associated with, an individual. For this, there has been ongoing research for privacy protection mechanism to protect PII, which now becomes one of hot issues in the International Standard as privacy framework and privacy reference architecture. Data processing flow models should be developed as an integral component of privacy risk assessments. Such diagrams are also the basis for categorizing PII. The data processing flow may not only show areas where the PII has a certain level of sensitivity or importance and, as a consequence, requires the implementation of stronger safeguarding measures. This paper propose a standard format for satisfying the ISO/IEC 29100 "Privacy Framework" and shows an implementation example for privacy reference architecture implementing privacy controls for the processing of PII in information and communication technology.

IoT 어플리케이션에서 활용하는 참조 전압을 같이 생성할 수 있는 표준 편차가 낮은 온도 센서 (A temperature sensor with low standard deviation with generating reference voltage for use in IoT applications)

  • 오주원;부영건;정연재;이강윤
    • 반도체공학회 논문지
    • /
    • 제2권2호
    • /
    • pp.10-14
    • /
    • 2024
  • 본 논문은 BJT 소자의 온도 특성에 의해 생성되는 전류를 활용하여 ADC 와 함께 센서의 정보를 변환하는 과정에서 필요한 참조 전압(Reference Voltage)과 온도센서 전압을 하나의 증폭기에서 생성하고자 하는 목적에 따라 설계하는 회로를 제안한다. 이와 함께 회로의 표준 편차를 줄이기 위한 두개의 컨트롤 방식이 추가되어 10 배 이상의 표준 편차를 감소시키는 결과를 얻게 된다. 제안하는 회로의 면적은 0.057mm2 이며 55nm RF 공정을 활용하였다.

자기 공명 영상법에서 Agarose 표준 물질을 사용한 유체 포화도의 계산 (Estimation of Fluid Saturations Using Agarose Standard in NMR Imaging)

  • 김경회
    • 공업화학
    • /
    • 제10권1호
    • /
    • pp.160-165
    • /
    • 1999
  • Gel 표준 물질의 핵자기 공명적 완화 성질들이 다공성 매체내 유체의 핵자기 공명적 완화 성질들과 잘 부합될 수 있기 때문에, agarose gel은 다공성 매체내 유체의 성질을 측정하기 위한 표준 물질로 사용될 수 있다. 다공성 매체의 세공도(porosity)와 포화도(saturation)를 결정하기 위한 표준물질의 사용을 논의하였고, gel의 핵자기 공명적 성질에 대한 필요조건들도 제시하였다. 2.0 Tesla에서 측정된 agarose gel의 완화시간은 agarose 농도와 상자기성 불순물의 ($CuSO_4$) 농도 함수로 표시하였고, agarose gel 조성과 완화시간 사이의 실험적 결과를 나타내었다. 세공도 분포에 대한 평균값은 17.7%이고, 이 값은 중량 분석법에 의해 계산된 값과 잘 일치한다. 끝으로, agarose gel을 표준 물질로 사용한 비혼화성 2상 유체실험을 수행하였다. 포화 profile들은 균일한 다공성 매체내에서 일차원 치환실험을 했을 때 계산된 결과와 잘 일치하고 있다.

  • PDF

Ecotoxicity Assessment of Potassium Hydrogen Phthalate and Verification of Standard Reference Toxicity Test Method Using Potassium Hydrogen Phthalate

  • Dong Jin Choi
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • 제4권1호
    • /
    • pp.49-62
    • /
    • 2023
  • Phthalates are animal carcinogens. Potassium hydrogen phthalate (KHP), which has the least complicated structure among phthalates, is used for the analysis of total organic carbon and formaldehyde. However, its toxicity has not been confirmed. A 24-hour acute toxicity test was performed using Daphnia magna, a water flea used to evaluate aquatic toxicity owing to its high sensitivity. The lowest observed effect concentration of KHP was found to be 240 mg/L. The effects of phosphorus, nitrogen, and Cr(6+), which are able to be discharged along with KHP, were also confirmed using tests. At 240 mg/L KHP, toxicity increased as phosphorus, nitrogen, and Cr(6+) increased. In addition, tests were performed to confirm the half maximal effective concentration of KHP. Through 10 test repetitions, the average ecotoxicity value was found to be 0.3, the average half maximal effective concentration was 327.75 mg/L, and the coefficient of variation (%) was 3.16%; because the latter value is lower than 25%, which is what is generally suggested for the water pollution standard method, the reproducibility of the tests is sufficient to replace the existing standard reference toxicity test that uses potassium dichromate. In addition, the half maximum effective concentration of potassium hydrogen phthalate is approximately 218 times more than that of potassium dichromate; therefore, toxicity is relatively low. In conclusion, KHP is a feasible alternative to the highly toxic potassium dichromate for performing the standard reference toxicity test.