• 제목/요약/키워드: the standard of reference

검색결과 2,159건 처리시간 0.029초

일본(日本) 수산계(水產系) 고등학교교육(高等學校敎育)의 현황(現況)과 전망(展望) -I. 학교(學校)의 분포(分布)와 교육과정(敎育課程)의 편제(編制) (The Present Status and Future Prospect on Education of Fisheries High School in Japan -I. Distribution of Schools and Arrangement of Curriculum)

  • 이병기
    • 수산해양교육연구
    • /
    • 제4권1호
    • /
    • pp.75-87
    • /
    • 1992
  • Cultivation of competent manpower is recognized as one of the important factors in the development of fisheries as well as of other industries. For reference to the development of education of fisheries high schools in the Republic of Korea, the author carried out a study on the education in Japan. The reason is why the education on fisheries had been initiated in Japan and her educational system has played the role of a model for neighboring countries. Even though the education on fisheries tends to shrink a little in recent years by diffusing the unwilling tendency to engage in 3D (dirty, difficult and dangerous) jobs, there are fifty-one high schools educating fisheries in Japan. Thirty-eight of them are specialized fisheries high schools and the others are comprehensive high schools to put common course and fisheries course together. In the first step of study, the goal of education on fisheries, organization of department and arrangement of curriculum are analysed. 1. In the newly arranged curriculum which will come into effect from 1994, the goal of education on fisheries is set up as "By educating fundamental knowledge and technology on the production and circulation in the field of fisheries, have students understand the significance and role of fisheries, and so cultivate ability and active attitude to the development of fisheries". The goal means that the circulation of fishery products are regarded as important as the production itself, and active attitude to the development of fisheries is also stressed, different from the present goal. 2. Standard departments directed by the Government are set up as five-Departments of Marine Fishing, of Fisheries Engineering, of Information Communication, of Fish Culture, of Sea Foods. But they are actually organized and named by the founders of schools-local government. Then there are many unique-named departments and the management of schools are somewhat flexible according to the situation of local district. 3. Special subjects are revised to twenty-four in the new curriculum from twenty-two in the present curriculum. Among them the contents are widely revised in the subjects such as Introduction to Fisheries, Fisheries Engineering, Communication Engineering, Communication Technology, Fish Culture. On the other hand, five subjects such as Information Treatment on Fisheries, Information Technology on Fisheries, Subjective Study, Fisheries Economics, Circulation of Sea Foods are newly set up to meet the changing phase of the time.

  • PDF

Reliability of mortar filling layer void length in in-service ballastless track-bridge system of HSR

  • Binbin He;Sheng Wen;Yulin Feng;Lizhong Jiang;Wangbao Zhou
    • Steel and Composite Structures
    • /
    • 제47권1호
    • /
    • pp.91-102
    • /
    • 2023
  • To study the evaluation standard and control limit of mortar filling layer void length, in this paper, the train sub-model was developed by MATLAB and the track-bridge sub-model considering the mortar filling layer void was established by ANSYS. The two sub-models were assembled into a train-track-bridge coupling dynamic model through the wheel-rail contact relationship, and the validity was corroborated by the coupling dynamic model with the literature model. Considering the randomness of fastening stiffness, mortar elastic modulus, length of mortar filling layer void, and pier settlement, the test points were designed by the Box-Behnken method based on Design-Expert software. The coupled dynamic model was calculated, and the support vector regression (SVR) nonlinear mapping model of the wheel-rail system was established. The learning, prediction, and verification were carried out. Finally, the reliable probability of the amplification coefficient distribution of the response index of the train and structure in different ranges was obtained based on the SVR nonlinear mapping model and Latin hypercube sampling method. The limit of the length of the mortar filling layer void was, thus, obtained. The results show that the SVR nonlinear mapping model developed in this paper has a high fitting accuracy of 0.993, and the computational efficiency is significantly improved by 99.86%. It can be used to calculate the dynamic response of the wheel-rail system. The length of the mortar filling layer void significantly affects the wheel-rail vertical force, wheel weight load reduction ratio, rail vertical displacement, and track plate vertical displacement. The dynamic response of the track structure has a more significant effect on the limit value of the length of the mortar filling layer void than the dynamic response of the vehicle, and the rail vertical displacement is the most obvious. At 250 km/h - 350 km/h train running speed, the limit values of grade I, II, and III of the lengths of the mortar filling layer void are 3.932 m, 4.337 m, and 4.766 m, respectively. The results can provide some reference for the long-term service performance reliability of the ballastless track-bridge system of HRS.

국가기록원의 기록물 정리기술의 현황과 개선방안 (The Present State and Solutions for Archival Arrangement and Description of National Archives & Records Service of Korea)

  • 윤주범
    • 한국기록관리학회지
    • /
    • 제4권2호
    • /
    • pp.118-162
    • /
    • 2004
  • 기록물 보존기관에서의 정리와 기술은 기록물 관리와 열람제공에 중요한 역할을 한다. 국가기록원(NRAS; National Records & Archinves Service)에서도 역시 정리와 기술에 대해 노력을 기울이고 있다. 하지만, 기록보존 선진국과 비교하면 이론 및 실제 처리과정에서 많은 차이와 문제점을 가지고 있다. 이론에 있어서 큰 차이는, 기록물의 기능분류와 원질서의 유지나 다계층기술이 정리 기술의 실제 업무처리에 반영되고 있지 않다. 즉, 기록물이 도서의 정리방식과 같이 낱권 단위로 등록순서에 따라 정리된 후 서가에 배열되고 있다. 이 외에도, 기록물 생산기관의 변천내력이나 색인어의 관리 등의 문제점을 가지고 있다. 이런 이유로 기록물의 이용이 매우 불편하다. 이들 문제점을 개선하기 위해서, 본 연구에서는 정리와 기술의 의의와 중요성, 국가기록원의 정리와 기술의 현황과 문제점, 그리고 외국의 국립기록보존소 기술지침을 소개하였다. 다음은 ISAD(G)를 적용한 사례를 소개하였다. 논문은 총 8장으로 구성하였는데, 제1장 서론, 제2장 정리 기술의 의의와 중요성 및 제8장 결론을 제외한 제3장부터 제7장의 내용은 다음과 같다. 제3장에서는 국가기록원의 정리 기술 현황으로, 현재 사용하고 있는 기록물관리 시스템(Govt) 운영현황과 사용하는 기술항목을 설명하였다. 제4장에서는 미국, 영국 및 호주의 국립기록보존소 기술지침 소개로 첫째, 미국의 국립기록관리청(NARA)의 기록물 생명주기 데이터 준수사항 지침(Lifecycle Data Requirements Guide)을 소개하였으며, 기술 항목중 타이틀요소 1개에 대한 기술요령을 소개하였다. 둘째, 영국국립기록보존소(Public Records Office)의 기술지침을 소개하였다. 기술지침의 명칭은 영국국립기록보존소 편목지침(National Archives Cataloguing Guidelines Introduction)이다. 이 지침에서 사용하는 "PROCAT"라는 전산목록시스템을 소개하였다. 이 시스템에서 사용하는 7단계 기술에 대해 설명하였다. 셋째, 호주 국립기록보존소(NAA; National Archives of Australia)의 기록물 시스템은 CRS(Commonwealth Record Series)이다. 이 시스템을 위한 기록물 등록과 기술절차(Registration &description procedures for CRS system)에 대해 연구하였다. 제5장에서는 ISAD(G)를 적용한 사례로, 국가기록원이 과거 총무처 소청심사위원회에서 생산한 기록물의 기술서를 소개하였다. 제6장, 7장에서는, ISAD(G)의 사용결과 문제점, 각 기관 처리과에서 문서제목 부여, 기술항목 부족, 기록물 종류나 유형분류, 관리번호, 상세한 기술규칙의 부재, 기능분류나 계층기술, 입력포맷, 서가배열, 전거통제 등의 문제점을 지적하였다. 개선 방안으로는 계층분류 체계의 마련, 관리번호 및 배열순서의 개선, 전거제어시스템 개발, 기술 입력항목의 증가, 기술규칙 제정 및 입력포맷개선 마련 등이다. 현재 국가기록원의 정리 기술 개선의 가장 좋은 방법은 기록물관리 선진국 국립기록보존소의 표준, 지침, 매뉴얼의 상세한 검토이다. 따라서 학계에서 이 분야의 많은 연구가 있어야 한다는 것을 제안하였다.

The preliminary study for three-dimensional alveolar bone morphologic characteristics for alveolar bone restoration

  • Cho, Hyun-Jae;Jeon, Jae-Yun;Ahn, Sung-Jin;Lee, Sung-Won;Chung, Joo-Ryun;Park, Chang-Joo;Hwang, Kyung-Gyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.33.1-33.7
    • /
    • 2019
  • Background: The concept of the ideal morphology for the alveolar bone form is an important element to reconstruct or restore the in maximizing esthetic profile and functional alveolar bone restoration. The purpose of this preliminary study is to evaluate the normal alveolar bone structure to provide the standard reference and guide template for use in diagnosing for implant placement, determining the correct amount of bone augmentation in actual clinical practice and producing prostheses based on three-dimensional imaging assessment of alveolar bone. Methods: This study was included 11 men and 11 women (average age, 22.6 and 24.5 years, respectively) selected from among 127 patients. The horizontal widths of alveolar bone of maxilla and mandible were measured at the crestal, mid-root, and root apex level on MDCT (multi-detector computed tomography) images reconstructed by medical imaging software. In addition, tooth dimensions of the central incisors, canines, second premolars, and first molars of maxilla and mandible, including the horizontal width of the interdental alveolar bone crest, were also measured and statistically analyzed. Results: The horizontal alveolar bone width of the palatal side of maxilla showed a distinct increment from the alveolar bone crest to the apical region in both anterior and posterior areas. The average widths of the maxillary alveolar ridge were as follows: central incisor, 7.43 mm; canine, 8.91 mm; second premolar, 9.57 mm; and first molar, 12.38 mm. The average widths of the mandibular alveolar ridge were as follows: central incisor, 6.21 mm; canine, 8.55 mm; second premolar, 8.45 mm; and first molar, 10.02 mm. In the buccal side, the alveolar bone width was not increased from the crest to the apical region. The horizontal alveolar bone width of an apical and mandibular border region was thinner than at the mid-root level. Conclusions: The results of the preliminary study are useful as a clinical guideline when determining dental implant diameter and position. And also, these measurements can also be useful during the production of prefabricated membranes and customized alveolar bone scaffolds.

나사형 임플란트 고정체의 길이, 직경, 플랫폼 형태에 따른 임플란트와 주위조직의 응력분포 (Influence of diameter, length, and platform shape of implant fixture on the stress distribution in and around the screw type implant)

  • 강지은;정현주;구철회;양홍서
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.277-288
    • /
    • 2002
  • Seven finite element models were constructed in mandible having single screw-type implant fixture connected to the premolar superstructure, in order to evaluate how the length, diameter and platform shape of a screw-type fixture influence the stress in the supporting tissue around fixtures. Each finite element model was varied in terms of length, diameter, and platform shape of the fixture. In each model, 250N of vertical load was placed on the central pit of an occlusal plane and 250N of oblique load placed on the buccal cusp. The stress distribution in the supporting tissue and the other components was analysed using 2-dimensional finite element analysis and the maximum von Mises stress in each reference area was compared. Under lateral loading, the stress was larger at the abutment/fixture interface, and in the crestal bone, compared to the stress pattern under vertical loading. The amount of stress at the superstructure was similar regardless of the length, diameter and platform shape of a fixture. Around the longer fixture, the stress was decreased at the bone crest and subjacent cancellous bone and increased in the cancellous bone area apical to the fixture. Around the wider fixture, the stress was decreased at the abutment/fixture interface, and the bone crest and increased in the cancellous bone area apical to the fixture. Around the fixture having wider platform, less stress was produced at the abutment/fixture interface and the upper part of the cortical bone, compared to the fixture having standard platform. In conclusion, the stress distribution of the supporting tissue was affected by length, diameter, and platform shape of a fixture, and the fixture which was larger in diameter and length could reduce the stress in the supporting tissues at the bone-fixture interface and bone crest area.

Comparative Performance of Susceptibility Map-Weighted MRI According to the Acquisition Planes in the Diagnosis of Neurodegenerative Parkinsonism

  • Suiji Lee;Chong Hyun Suh;Sungyang Jo;Sun Ju Chung;Hwon Heo;Woo Hyun Shim;Jongho Lee;Ho Sung Kim;Sang Joon Kim;Eung Yeop Kim
    • Korean Journal of Radiology
    • /
    • 제25권3호
    • /
    • pp.267-276
    • /
    • 2024
  • Objective: To evaluate the diagnostic performance of susceptibility map-weighted imaging (SMwI) taken in different acquisition planes for discriminating patients with neurodegenerative parkinsonism from those without. Materials and Methods: This retrospective, observational, single-institution study enrolled consecutive patients who visited movement disorder clinics and underwent brain MRI and 18F-FP-CIT PET between September 2021 and December 2021. SMwI images were acquired in both the oblique (perpendicular to the midbrain) and the anterior commissure-posterior commissure (AC-PC) planes. Hyperintensity in the substantia nigra was determined by two neuroradiologists. 18F-FP-CIT PET was used as the reference standard. Inter-rater agreement was assessed using Cohen;s kappa coefficient. The diagnostic performance of SMwI in the two planes was analyzed separately for the right and left substantia nigra. Multivariable logistic regression analysis with generalized estimating equations was applied to compare the diagnostic performance of the two planes. Results: In total, 194 patients were included, of whom 105 and 103 had positive results on 18F-FP-CIT PET in the left and right substantia nigra, respectively. Good inter-rater agreement in the oblique (κ = 0.772/0.658 for left/right) and AC-PC planes (0.730/0.741 for left/right) was confirmed. The pooled sensitivities for two readers were 86.4% (178/206, left) and 83.3% (175/210, right) in the oblique plane and 87.4% (180/206, left) and 87.6% (184/210, right) in the AC-PC plane. The pooled specificities for two readers were 83.5% (152/182, left) and 82.0% (146/178, right) in the oblique plane, and 83.5% (152/182, left) and 86.0% (153/178, right) in the AC-PC plane. There were no significant differences in the diagnostic performance between the two planes (P > 0.05). Conclusion: There are no significant difference in the diagnostic performance of SMwI performed in the oblique and AC-PC plane in discriminating patients with parkinsonism from those without. This finding affirms that each institution may choose the imaging plane for SMwI according to their clinical settings.

Shigella R Plasmid의 분자적 특성 (Molecular Characteristics of R Plasmids in Shigella)

  • 이유철;설성용;조동택;전도기
    • 대한미생물학회지
    • /
    • 제22권1호
    • /
    • pp.35-53
    • /
    • 1987
  • Multiply resistant Shigella strains isolated in Taegu area were subjected for the characterization of R plasmids. All strains isolated in 1984 and 1985 were susceptible to gentamicin, amikacin, and cephalothin, and most strains were susceptible to kanamycin (Km) and rifampin by agar dilution antimicrobial susceptibility test. The resistance frequency of S. flexneri against ampicillin (Ap) was higher than that of S. sonnei. The strains resistant to sulfisomidine (Su) and trimethoprim (Tp) were found at higher frequency in S. sonnei than in S. flexneri. The most prevalent resistance pattern of S. flexneri was chloramphenicol (Cm) tetracycline (Tc) streptomycin (Sm) Ap, followed by the pattern of CmTcSmSuApTp, CmTcSmSuApTp nalidixic acid, and CmTcSmSuAp in the decreasing order. The antibiogram of CmTcSmSuTp was found to be the most frequent pattern in S. sonnei. The ratio of conjugal transfer of S. flexneri was 47% and 75% of S. sonnei. The average number of plasmid harboring in Shigella was 4 and the size of plasmid ranged 1.3 to 134 megadalton (Mdal). Most S. flexneri carried plasmids of 2 to 3 Mdal and S. sonnei carried those of 3 to 4 Mdal size. The sizes of conjugative plasmids ranged 40-90 Mdal. The incompatibility group (Inc) F II plasmids (54-59 Mdal) were most frequent and rare Inc B plasmids (60 Mdal) of isolates in 1979 and 1980 and Inc FI (87 Mdal) of 1983 isolates were able to be classified by the colony test with standard reference plasmids. The R plasmids of known Inc group were tested for the restriction endonuclease analysis. The pattern of plasmids digested by EcoRl were apparently different by the Inc group but there was no significant difference between species or by the resistance patterns. Nonconjugative plasmids and their phenotypes were identified by transformation test. The transformants were resistant to less than two drugs. Colicin producing transformants carried the Col plasmid of 3.7 or 3.9 Mdal size. $Ap^r$ plasmids derived from S. sonnei were found to be mobilized by transfer factor RT641 to E. coli #CS100. $Ap^r$ plasm ids of same size shared by S. flexneri, S. sonnei, and E. coli were digested with Pstl. All of them showed two restriction fragments of 2.8 kilobase(kb) and 0.7kb. Other plasmids ($Sm^r\;Su^r$) derived from S. flexneri, S. boydii, and S. sonnei were digested with Pstl and they showed same restriction fragment patterns of 3.1kb and 2.9kb. The plasmid profiles of three strains of S. sonnei producing colicin and showing same resistance pattern of CmTcSmSuApTpKm appeared to be similar. Restriction patterns by EcoRl and the behavior of plasmids in conjugation or transformation process were also similar between those plasmids. The restriction patterns were significantly different between the plasmids of Inc FI group and those of unclassified Inc group.

  • PDF

Comparisons between the KKU-Model and Conventional Rectal Tubes as Markers for Checking Rectal Doses during Intracavitary Brachytherapy of Cervical Cancer

  • Padoongcharoen, Prawat;Krusun, Srichai;Palusuk, Voranipit;Pesee, Montien;Supaadirek, Chunsri;Thamronganantasakul, Komsan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6115-6120
    • /
    • 2014
  • Background: To compare the KKU-model rectal tube (KKU-tube) and the conventional rectal tube (CRT) for checking rectal doses during high-dose-rate intracavitary brachytherapy (HDR-ICBT) of cervical cancer. Materials and Methods: Between February 2010 and January 2011, thirty -two patients with cervical cancer were enrolled and treated with external beam radiotherapy (EBRT) and intracavitary brachytherapy (ICBT). The KKU-tube and CRT were applied intrarectally in the same patients at alternate sessions as references for calculation of rectal doses during ICBT. The gold standard references of rectum anatomical markers which are most proximal to radiation sources were anterior rectal walls (ARW) adjacent to the uterine cervix demonstrated by barium sulfate suspension enema. The calculated rectal doses derived from actual anterior rectal walls, CRT and the anterior surfaces of the KKU-tubes were compared by using the paired t-test. The pain caused by insertion of each type of rectal tube was assessed by the visual analogue scale (VAS). Results: The mean dose of CRT was lower than the mean dose of ARW ($Dmean_0-Dmean_1$) by $80.55{\pm}47.33cGy$ (p-value <0.05). The mean dose of the KKU-tube was lower than the mean dose of ARW ($Dmean_0-Dmean_2$) by $30.82{\pm}24.20cGy$ (p-value <0.05). The mean dose difference [($Dmean_0-Dmean_1$)-($Dmean_0-Dmean_2$)] was $49.72{\pm}51.60cGy$, which was statistically significant between 42.32 cGy -57.13 cGy with the t-value of 13.24 (p-value <0.05). The maximum rectal dose by using CRT was higher than the KKU-tube as much as 75.26 cGy and statistically significant with the t-score of 7.55 (p-value <0.05). The mean doses at the anterior rectal wall while using the CRTs and the KKU-tubes were not significantly different (p-value=0.09). The mean pain score during insertion of the CRT was significantly higher than the KKU-tube by a t-score of 6.15 (p-value <0.05) Conclusions: The KKU-model rectal tube was found to be an easily producible, applicable and reliable instrument as a reference for evaluating the rectal dose during ICBT of cervical cancer without negative effects on the patients.

구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구 (Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height)

  • 정병준;이영후;홍성진;백장현;노관태;배아란;김형섭;권긍록
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.27-35
    • /
    • 2021
  • 목적: 현재 임상에서 스캔바디를 이용한 임플란트의 디지털 인상이 활용되고 있으나 스캔바디의 형태에 따른 스캔의 정확도에 대한 연구는 부족한 실정이다. 본 연구의 목적은 구내 스캔바디의 형태에 따른 스캔의 정확도를 비교하고, 구강 내 노출 높이에 따른 라이브러리 중첩 정확도를 비교하기 위함이다. 재료 및 방법: 덴티폼 상에서 36번 치아를 삭제 후 모델 스캐너로 스캔하여 3D 프린터로 주모형을 출력하였다. 첫 번째 실험으로 세 종류(A, B, C)의 구내 스캔바디를 준비하여 각 그룹마다 다음과 같은 실험을 하였다: 36번 부위에 임플란트를 이상적인 위치로 식립 후 스캔바디를 15 N으로 체결하였다. 스캔바디가 체결된 주모형을 모델 스캐너로 스캔하여 master reference file (대조군)을 STL (Standard Tessellation Language) file로 생성하였다. 이후 구강 스캐너로 10회의 연속적인 스캔을 시행하여 10개의 STL file (실험군)을 생성하였다. 3D 측정 소프트웨어를 이용하여 대조군과 실험군들의 STL file들을 중첩한 후 좌표계 상에서 다음과 같은 값들을 도출하였다: 1) 스캔바디 상 특정 point의 거리 편차 2) 스캔바디 장축의 각도 편차. 두 번째 실험으로는 스캔바디의 구강내 노출 높이에 따른 라이브러리 중첩 정확도를 비교하기 위해 스캔바디 스캔 데이터를 7, 4.5, 2.5, 1.5, 1.0, 0.5 mm 총 6 가지 높이로 준비하여 라이브러리 파일과 중첩하였다. 전체가 노출된 7 mm 데이터를 대조군으로 하여 거리 편차와 각도 편차를 계산하였다. 결과: 첫번째 실험에서 A, B 스캔바디 간(P = .278), B, C 스캔바디 간(P = .568), C, A 스캔바디 간(P = .711) 스캔 파일의 거리 편차 모두 유의한 차이가 나타나지 않았다. A, B 스캔바디 간(P= .568), B, C 스캔바디 간(P = .546), C, A 스캔바디 간(P = .112) 스캔 파일의 각도 편차 또한 모두 유의한 차이가 나타나지 않았다. 또한 스캔바디는 구강 내 노출 높이가 높은 실험군(GH, Gingival Height = 4.5)의 라이브러리 중첩 정확도가 높이가 낮은 실험군(GH = 0.5)보다 통계적으로 유의하게 높았다 (P < .05). 결론: 스캔바디의 각기 다른 형태에 따른 스캔 정확도는 유의한 차이가 없었으며, 스캔바디의 구강 내 노출 높이에 따라 라이브러리 중첩의 정확도는 증가한다. 추후 in vivo 환경에서 더 다양한 형태의 스캔바디를 이용한 후속연구가 필요할 것이다.

고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구 (A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.487-494
    • /
    • 2020
  • 선원과 검출기 사이의 거리, 검출기 지름, 방사선원의 부피 효과 등에 의해 검출기 입사면에서 입체각(solid angle)의 변화가 생기고 이는 검출기 내부에서의 경로 길이(path length) 차이를 유발하여 검출효율 결정에 영향을 미친다. 유효입체각 계산을 위한 일반적인 분석 방법은 단순한 기하학적 구조를 가진 선원 (60Co)에만 유용하여 본 실험에서는 검출기와 선원 간 거리 window cap 0.5 cm 기준점으로 하여 25 cm 까지 이동 시 켜면서 측정하였다. 또한 표준부피선원 450 ㎖, 1000 ㎖ 마리넬리 비이커는 검출기에 밀착 시켜 측정하였다. 검출기와 동축인 원형 점선원의 경우, 검출기 창으로부터의 거리에 대한 입체 각도의 변화를 측정치와 몬테카를로 시뮬레이션으로 계산 분석 관계의 결과 검출기의 반지름이 선원의 반지름보다 작을 경우, 입체 각도는 선원의 제곱 반지름 대 검출기의 제곱 반지름의 절반과 같다. 입체 각도의 차이는 0.53가 되므로 몬테카를로의 결과는 허용된다. 검출기-선원 간 거리의 역수와의 관계를 나타내었다. 입체각도는 거리에 따라 급격하게 감소함을 확인하였다. 부피선원에 대한 측정치와 시뮬레이션 결과는 거리 0 cm에서 1.01 %이며 거리가 5 cm, 10 cm로 멀어지면 4 % 미만의 차이를 보인다. 거리가 10 cm 일 때 처음으로 계산결과가 측정 결과보다 작아진다. 이는 거리가 멀어질수록 입체각이 작아지고, 에너지가 낮아질수록 감쇠효과가 지수 함수적으로 증가하는 원리가 효율의 계산에 반영되는 것을 확인할 수 있다. 따라서 검출효율은 고체 각도 및 몬테카를로 코드를 사용하기에 충분함을 입증하였다.