• Title/Summary/Keyword: the standard of reference

Search Result 2,150, Processing Time 0.034 seconds

Cone-beam computed tomographic analysis of the alveolar ridge profile and virtual implant placement for the anterior maxilla

  • Lim, Hyun-Chang;Kang, Do-Uk;Baek, Hyehyeon;Hong, Ji-Youn;Shin, Seung-Yun;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.299-309
    • /
    • 2019
  • Purpose: To analyze the ridge profile of the anterior maxilla using cone-beam computed tomography and to assess the clinical significance of the ridge profile by performing virtual implant placement. Methods: Thirty-two cone-beam computed tomography scans of anterior maxillae were included. For each tooth, a vertical line was made along the longitudinal axis, and 3 horizontal lines at 1-, 3-, and 5-mm levels below the labial bone crest were drawn perpendicularly to the vertical reference. At these levels, the thickness of the alveolar ridge (RT), and the labial (LT) and palatal bone plate (PT) were measured. Then, virtual implant placement using standard and tapered implants was performed. A generalized linear mixed model was used for statistical analysis. Results: The teeth were located labially based on the proportion of LT and PT with respect to RT. At the 1-mm level, the value of LT was between $1.0{\pm}0.4mm$ for central incisors and $1.3{\pm}0.6mm$ for canines. A large number of teeth had area(s) with less than 1-mm-thick labial bone between the 1- and 5-mm levels below the crest. The mean PT was generally thicker than the LT in all tooth types. The greatest mean value of labial concavity was observed for canines, compared to other tooth types. Men had a greater RT than did women, but had a comparable LT. Less apical fenestration was observed when tapered implants were used. Conclusions: Most teeth in the anterior maxilla had a thin labial bone plate, with no significant difference between sexes. Tapered implants may be advantageous for the anterior maxilla.

Estimating soils properties using NIRS to assess amendments in intensive horticultural production

  • Pena, Francisco;Gallardo, Natalia;Campillo, Carmen Del;Garrido, Ana;Cabanas, Victor Fernandez;Delgado, Antonio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1615-1615
    • /
    • 2001
  • During the past ten years, Near Infrared Spectroscopy has been successfully applied to the analysis of a great variety of agriculture products. Previous works (Morra et al., 1991; Salgo et al., 1998) have shown the potential of this technology for soil analysis, estimating different parameters just with one single scan. The main advantages of NIR applications in soils are the speed of response, allowing the increase of the number of samples analysed to define a particular soil, and the instantaneous elaboration of recommendations for fertilization and soil amendment. Another advantage is to avoid the use of chemical reagents at all, being an environmentally safe technique. In this paper, we have studied a set of 129 soil samples selected from representative glasshouse soils from Southern Spain. The samples were dried, milled, and sieved to pass a 2 mm sieve and then analysed for organic carbon, total nitrogen, inorganic nitrogen (nitrate ammonium), hygroscopic humidity, pH and electrical conductivity in the 1:1 extract. NIR spectra of all samples were obtained in reflectance mode using a Foss NIR Systems 6500 spectrophotometer equipped with a spinning module. Calibration equations were developed for seven analytical parameters (ph, Total nitrogen, organic nitrogen, organic carbon, C/N ratio and Electric Conductivity). Preliminary results show good correlation coefficients and standard errors of cross validation in equations obtained for Organic Carbon, Organic Nitrogen, Total Nitrogen and C/N ratio. Calibrations for nitrates and nitrites, ammonia and electric conductivity were not acceptable. Calibration obtained for pH had an acceptable SECV, but the determination coefficient was found very poor probably due to the reduced range in reference values. Since the estimation of Organic Carbon and C/N ratio are acceptable NIIRS could be used as a fast method to assess the necessity of organic amendments in soils from Mediterranean regions where the low level of organic matter in soils constitutes an important agronomic problem. Furthermore, the possibility of a single and fast estimation of Total Nitrogen (tedious determination by modifications of the Kjeldahl procedure) could provide and interesting data to use in the estimation of nitrogen fertilizer rates by means of nitrogen balances.

  • PDF

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

Optimized DSP Implementation of Audio Decoders for Digital Multimedia Broadcasting (디지털 방송용 오디오 디코더의 DSP 최적화 구현)

  • Park, Nam-In;Cho, Choong-Sang;Kim, Hong-Kook
    • Journal of Broadcast Engineering
    • /
    • v.13 no.4
    • /
    • pp.452-462
    • /
    • 2008
  • In this paper, we address issues associated with the real-time implementation of the MPEG-1/2 Layer-II (or MUSICAM) and MPEG-4 ER-BSAC decoders for Digital Multimedia Broadcasting (DMB) on TMS320C64x+ that is a fixed-point DSP processor with a clock speed of 330 MHz. To achieve the real-time requirement, they should be optimized in different steps as follows. First of all, a C-code level optimization is performed by sharing the memory, adjusting data types, and unrolling loops. Next, an algorithm level optimization is carried out such as the reconfiguration of bitstream reading, the modification of synthesis filtering, and the rearrangement of the window coefficients for synthesis filtering. In addition, the C-code of a synthesis filtering module of the MPEG-1/2 Layer-II decoder is rewritten by using the linear assembly programming technique. This is because the synthesis filtering module requires the most processing time among all processing modules of the decoder. In order to show how the real-time implementation works, we obtain the percentage of the processing time for decoding and calculate a RMS value between the decoded audio signals by the reference MPEG decoder and its DSP version implemented in this paper. As a result, it is shown that the percentages of the processing time for the MPEG-1/2 Layer-II and MPEG-4 ER-BSAC decoders occupy less than 3% and 11% of the DSP clock cycles, respectively, and the RMS values of the MPEG-1/2 Layer-II and MPEG-4 ER-BSAC decoders implemented in this paper all satisfy the criterion of -77.01 dB which is defined by the MPEG standards.

Tumor Habitat Analysis Using Longitudinal Physiological MRI to Predict Tumor Recurrence After Stereotactic Radiosurgery for Brain Metastasis

  • Da Hyun Lee;Ji Eun Park;NakYoung Kim;Seo Young Park;Young-Hoon Kim;Young Hyun Cho;Jeong Hoon Kim;Ho Sung Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.3
    • /
    • pp.235-246
    • /
    • 2023
  • Objective: It is difficult to predict the treatment response of tissue after stereotactic radiosurgery (SRS) because radiation necrosis (RN) and tumor recurrence can coexist. Our study aimed to predict tumor recurrence, including the recurrence site, after SRS of brain metastasis by performing a longitudinal tumor habitat analysis. Materials and Methods: Two consecutive multiparametric MRI examinations were performed for 83 adults (mean age, 59.0 years; range, 27-82 years; 44 male and 39 female) with 103 SRS-treated brain metastases. Tumor habitats based on contrast-enhanced T1- and T2-weighted images (structural habitats) and those based on the apparent diffusion coefficient (ADC) and cerebral blood volume (CBV) images (physiological habitats) were defined using k-means voxel-wise clustering. The reference standard was based on the pathology or Response Assessment in Neuro-Oncologycriteria for brain metastases (RANO-BM). The association between parameters of single-time or longitudinal tumor habitat and the time to recurrence and the site of recurrence were evaluated using the Cox proportional hazards regression analysis and Dice similarity coefficient, respectively. Results: The mean interval between the two MRI examinations was 99 days. The longitudinal analysis showed that an increase in the hypovascular cellular habitat (low ADC and low CBV) was associated with the risk of recurrence (hazard ratio [HR], 2.68; 95% confidence interval [CI], 1.46-4.91; P = 0.001). During the single-time analysis, a solid low-enhancing habitat (low T2 and low contrast-enhanced T1 signal) was associated with the risk of recurrence (HR, 1.54; 95% CI, 1.01-2.35; P = 0.045). A hypovascular cellular habitat was indicative of the future recurrence site (Dice similarity coefficient = 0.423). Conclusion: After SRS of brain metastases, an increased hypovascular cellular habitat observed using a longitudinal MRI analysis was associated with the risk of recurrence (i.e., treatment resistance) and was indicative of recurrence site. A tumor habitat analysis may help guide future treatments for patients with brain metastases.

Study on Direct Tensile Properties and Reliability Review of Steel Fiber Reinforced UHPC (강섬유 보강 UHPC의 직접인장 특성 및 신뢰성 검토에 관한 연구)

  • Park, Ji Woong;Lee, Gun Cheol;Koh, Kyung Taek;Ryu, Gum Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.125-132
    • /
    • 2018
  • In this study, a direct tensile test was planned to identify the tensile performance of UHPC, and the irregularity of cracks, which is a problem of the direct tensile test, was complemented through the introduction of notches at the center of a specimen. In this regard, a number of specimens divided by batch to reduce the deviation of direct tensile test values were fabricated to present reference data with respect to highly reliable direct tensile strength values. In addition, the mechanical properties and reliability of the specimens were examined under the curing conditions of the specified design strength of 120MPa for the steel fiber reinforced concrete with 1.5% fiber volume fraction, which is most suitable for the field application. As a result, the deviation of averages by batch between compressive strength and direct tensile strength did not show a large difference, and all cracks occurred within 20mm in the direct tensile test. At the 95% confidence interval of the direct tensile strength, the range was considerably small in the mean and the standard deviation, and there was no significant difference depending on the curing conditions. The results confirmed that a stable direct tensile test was performed, and highly reliable results were obtained through the fabrication of specimens by batch and test progress.

The Value of Adding Ductography to Ultrasonography for the Evaluation of Pathologic Nipple Discharge in Women with Negative Mammography

  • Younjung Choi;Sun Mi Kim;Mijung Jang;Bo La Yun;Eunyoung Kang;Eun-Kyu Kim;So Yeon Park;Bohyoung Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.866-877
    • /
    • 2022
  • Objective: The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. Materials and Methods: From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23-75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of follow-up with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar's test or a generalized estimating equation. Results: In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). Conclusion: The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

Phytochemical, Antidiabetic, Antioxidant, Antibacterial, Acute and Sub-Chronic Toxicity of Moroccan Arbutus unedo Leaves

  • Latifa Doudach;Hanae Naceiri Mrabti;Samiah Hamad Al-Mijalli;Mohamed Reda Kachmar;Kaoutar Benrahou;Hamza Assaggaf;Ahmed Qasem;Emad Mohamed Abdallah;Bodour Saeed Rajab;Khouloud Harraqui;Mouna Mekkaoui;Abdelhakim Bouyahya;Moulay El Abbes Faouzi
    • Journal of Pharmacopuncture
    • /
    • v.26 no.1
    • /
    • pp.27-37
    • /
    • 2023
  • Objectives: Moroccan Arbutus unedo is an essential medicinal plant; however, little is known about the biological properties of its leaves mentioned in Moroccan traditional medicine. Methods: Various standard experiments were performed to evaluate the phytochemical, antidiabetic, antioxidant, antibacterial, and acute and sub-chronic toxicity characteristics of A. unedo leaves. Results: Phytochemical screening led to the identification of several phytochemical classes, including tannins, flavonoids, terpenoids, and anthraquinones, with high concentrations of polyphenols (31.83 ± 0.29 mg GAEs/g extract) and flavonoids (16.66 ± 1.47 mg REs/g extract). Further, the mineral analysis revealed high levels of calcium and potassium. A. unedo extract demonstrated significant antioxidant and anti-diabetic activities by inhibiting α-amylase (1.350 ± 0.32 g/mL) and α-glucosidase (0.099 ± 1.21 g/mL) compared to the reference drug Acarbose. Also, the methanolic extract of the plant exhibited significantly higher antibacterial activity than the aqueous extract. Precisely, three of the four examined bacterial strains exhibited substantial susceptibility to the methanolic extract . Minimum bactericidal concentration (MBC)/minimum inhibitory concentration (MIC) values indicated that A. unedo harbor abundant bactericidal compounds. For toxicological studies, mice were administered with A. unedo aqueous extract at single doses of 2,000 and 5,000 mg/kg. They did not exhibit significant abnormal behavior, toxic symptoms, or death during the 14-day acute toxicity test and the 90-day sub-chronic toxicity test periods. The general behavior, body weight, and hematological and biochemical status of the rats were assessed, revealing no toxicological symptoms or clinically significant changes in biological markers observed in the mice models, except hypoglycemia, after 90 days of daily dose administration. Conclusion: The study highlighted several biological advantages of A. unedo leaves without toxic effects in short-term application. Our findings suggest that conducting more comprehensive and extensive in vivo investigations is of utmost importance to identify molecules that can be formulated into pharmaceuticals in the future.

Korean Food Exchange Lists for Diabetes: Revised 2010 (2010 당뇨병 환자를 위한 식품교환표 개정)

  • Ju, Dal-Lae;Jang, Hak-Chul;Cho, Young-Yun;Cho, Jae-Won;Yoo, Hye-Sook;Choi, Kyung-Suk;Woo, Mi-Hye;Sohn, Cheong-Min;Park, Yoo-Kyoung;Choue, Ryo-Won
    • Journal of Nutrition and Health
    • /
    • v.44 no.6
    • /
    • pp.577-591
    • /
    • 2011
  • A food exchange system for diabetes is a useful tool for meal planning and nutritional education. The first edition of the Korean food exchange lists was developed in 1988 and the second edition was revised in 1995. With recent changes in the food marketplace and eating patterns of Koreans, the third edition of food exchange lists was revised in 2010 by the Korean Diabetes Association, the Korean Nutrition Society, the Korean Society of Community Nutrition, the Korean Dietetic Association and the Korean Association of Diabetes Dietetic Educators through a joint research effort. The third edition is based on nutritional recommendations for people with diabetes and focuses on adding foods to implement personalized nutrition therapy considering individual preferences in diverse dietary environment. Foods were selected based on scientific evidence including the 2007 Korea National Health and Nutrition Examination Survey data analysis and survey responses from 53 diabetes dietetic educators. While a few foods were deleted, a number of foods were added, with 313 food items in food group lists and 339 food items in the appendix. Consistent with previous editions, the third edition of the food exchange lists included six food categories (grains, meat, vegetables, fats and oils, milk, and fruits). The milk group was subdivided into whole milk group and low fat milk. The standard nutrient content in one exchange from each food group was almost the same as the previous edition. Korea Food & Drug Administration's FANTASY (Food And Nutrient daTA SYstem) database was used to obtain nutrient values for each individual food and to determine the serving size most appropriate for matching reference nutrients values by each food group. The revised food exchange lists were subjected to a public hearing by experts. The third edition of the food exchange lists will be a helpful tool for educating people with diabetes to select the kinds and amounts of foods for glycemic control, which will eventually lead to preventing complications while maintaining the pleasure of eating.

Performance Characteristics of PM10 and PM2.5 Samplers with an Advanced Chamber System (챔버 기술 개발을 통한 PM10과 PM2.5 시료채취기의 수행 특성)

  • Kim, Do-Hyeon;Kim, Seon-Hong;Kim, Ji-Hoon;Cho, Seung-Yeon;Park, Ju-Myon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.739-746
    • /
    • 2010
  • The purposes of this study are 1) to develop an advanced chamber system within ${\pm}10%$ of air velocity at the particulate matter (PM) collection area, 2) to research theoretical characteristics of PM10 and PM2.5 samplers, 3) to assess the performance characteristics of PM10 and PM2.5 samplers through chamber experiments. The total six one-hour experiments were conducted using the cornstarch with an mass median aerodynamic diameter (MMAD) of $20\;{\mu}m$ and an geometric standard deviation of 2.0 at the two different air velocity conditions of 0.67 m/s and 2.15 m/s in the chamber. The aerosol samplers used in the present study are one APM PM10 and one PM2.5 samplers accordance with the US federal reference methods and specially designed three mini-volume aerosol samplers (two for PM10 and one for PM2.5). The overall results indicate that PM10 and PM2.5 mini-volume samplers need correction factors of 0.25 and 0.39 respectively when APM PM samplers considered as reference samplers and there is significant difference between two mini-volume aerosol samplers when a two-way analysis of variance is tested using the measured PM10 mass concentrations. The PM10 and PM2.5 samplers with the cutpoints and slopes (PM10: $10{\pm}0.5\;{\mu}m$ and $1.5{\pm}0.1$, PM2.5: $2.5{\pm}0.2\;{\mu}m$ and $1.3{\pm}0.03$) theoretically collect the ranges of 86~114% and 64~152% considering the cornstarch characteristics used in this research. Furthermore, the calculated mass concentrations of PM samplers are higher than the ideal mass concentrations when the airborne MMADs for the cornstarch used are smaller than the cutpoints of PM samplers and the PM samplers collected less PM in another case. The chamber experiment also showed that PM10 and PM2.5 samplers had the bigger collection ranges of 37~158% and 55~149% than the theocratical calculated mass concentration ranges and the relatively similar mass concentration ranges were measured at the air velocity of 2.15 m/s comparing with the 0.67 m/s.