• Title/Summary/Keyword: the plate waste

Search Result 191, Processing Time 0.026 seconds

Selection and Characterization of Pseudomonas aeruginosa EMS1 Mutant strain Showing Enhanced Biosurfactant Production

  • Cha, Mi-Sun;Lee, Kuen-Hee;Lee, Na-Eun;Lee, Sang-Joon
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.434-437
    • /
    • 2003
  • A new bacterial strain, was isolated from activated sludge, identified and named P. aeruginosa EMS1. The new strain produced surface-active rhamnolipids by batch cultivation in mineral salts medium with waste flying oils. The mutant strain KH7, designated P. aeruginosa EMS1, derived by random mutagenesis with N-methyl-N-nitro-N-nitrosogoanidine treatment producing high levels of the biosurfactants was selected by an ion-pair plate assay. The mutant strain KH7 showed 4-5 times more hydrocarbon emulsification as compared to the parent when grown on waste frying oils and various hydrocarbons. Furthermore, P. aeruginosa EMS1 and mutant strain KH7 was also able to use whey as a co-substrate for growth and biosurfactant production. As results of this study, mutant strain KH7 is a very efficient biosurfactant producer, and its culture conditions are relatively inexpensive and economical. Rhamnolipid is synthesized by the rhlAB-encoded rhamnosyltransferase. To be convinced of these genes, we performed PCR based on P. aeruginosa PAO1 whole-genome database. rhl gene cluster nucleotide and amino acid sequences were compared for both parent and mutant. Comparison of nucleotide sequence of rhlAB, there were usually terminal's codons exchange.

  • PDF

A Study on the Cementation Reaction of Copper-containing Waste Etching Solution to the Shape of Iron Samples (철 샘플에 따른 구리 함유 폐에칭액의 시멘테이션 반응에 대한 연구)

  • Kim, Bo-Ram;Jang, Dae-Hwan;Kim, Dae-Weon
    • Clean Technology
    • /
    • v.27 no.3
    • /
    • pp.240-246
    • /
    • 2021
  • The waste etching solution for chip on film (COF) contained about 3.5% copper, and it was recovered through cementation using iron samples. The effect of cementation with plate, chip, and powder iron samples was investigated. The molar ratio (m/r) of iron to copper was used as a variable in order to increase the recovery rate of copper. As the molar ratio increased, the copper content in the solution rapidly decreased at the beginning of the cementation reaction. Before and after the reaction, the copper content of the solution was determined by Inductively Coupled Plasma (ICP) using copper concentration according to time. After cementation at room temperature for 1 hour, the recovery rate of copper had increased the most in the iron powder sample, having the largest specific surface area of the samples, followed by the chip and plate samples. The recovered copper powder was characterized for its crystalline phase, morphology, and elemental composition by X-ray diffraction (XRD), scanning electron microscopy (SEM), and Energy-dispersive X-ray spectroscopy (EDS), respectively. Copper and unreacted iron were present together in the iron powder samples. The optimum condition for recovering copper was obtained using iron chips with a molar ratio of iron to copper of 4 giving a recovery rate of about 98.4%.

Utilization of Waste Tires as Soil Reinforcement; (1) Soil Reinforcing Effect (지반보강재로서 폐타이어의 활용; (1) 지반보강 효과)

  • 윤여원;최경순;윤길림;김방식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.107-117
    • /
    • 2004
  • This paper is to investigate the reinforcing effects of newly devised Tire-cell mat made of waste tires in sand. Parametric study on number of connection bolts between Tirecells, relative density of sand, embedded depth, number of reinforced layers and width of Tirecell mat was made by using plate loading tests. It is found that the number of connection bolt was enough to maintain the given pressure. The bearing capacity ratio(BCR), which is defined as the rate of ultimate bearing capacity of reinforced soil to that of unreinforced soil, is the highest at the lowest density. And the reinforcing effect can be obtained in case of embedded depth within 1.0B, where B is loading width. Also settlement reduction is the highest at the lowest density of sand. The effect of number of Tirecell reinforced layers with 0.4B to 0.5B interval is limited to 2 layers and further reinforcing effects can not be obtained beyond 3 layers. Especially, the bearing capacity increased remarkably at 1 layer of reinforcement and the degree of increase was small from 1 layer to 2 layers of reinforcement. The effect of mat width of Tirecell was not significant because of high stiffness of Tirecell although the maximum bearing capacity was shown at the 2.0B mat width and the reinforcing effects of Tirecell, in general, was prominent compared with those of commercial Geoweb.

Effect of AlF3 on Zr Electrorefining Process in Chloride-Fluoride Mixed Salts for the Treatment of Cladding Hull Wastes (폐 피복관 처리를 위한 염소계-불소계 혼합용융염 내 지르코늄 전해정련공정에서 삼불화알루미늄의 효과 연구)

  • Lee, Chang Hwa;Kang, Deok Yoon;Lee, Sung-Jai;Lee, Jong-Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.127-137
    • /
    • 2019
  • Zr electrorefining is demonstrated herein using Zirlo tubes in a chloride-fluoride mixed molten salt in the presence of $AlF_3$. Cyclic voltammetry reveals a monotonic shift in the onset of metal reduction kinetics towards positive potential and an increase in intensity of the additional peaks associated with Zr-Al alloy formation with increasing $AlF_3$ concentration. Unlike the galvanostatic deposition mode, a radial plate-type Zr growth is evident at the top surface of the salt during Zr electrorefining at a constant potential of -1.2 V. The diameter of the plate-type Zr deposit gradually increases with increasing $AlF_3$ concentration. Scanning electron microscopy-energy-dispersive X-ray spectroscopy (SEM-EDX) and X-ray photoelectron spectroscopy (XPS) analyses for the plate-type Zr deposit show that trace amount of Al is incorporated as Zr-Al alloys with different chemical compositions between the top and bottom surface of the deposit. Addition of $AlF_3$ is effective in lowering the residual salt content in the deposit and in improving the current efficiency for Zr recovery.

Characterizations of Assimilable Organic Carbon, Biodegradable Dissolved Organic Carbon, and Bacterial Regrowth in Distribution Systems by Water Treatment (배수관망에서 수처리에 의한 AOC, BDOC및 세균성장의 특성)

  • Chang, Young-Cheol;Kweon Jung;Yoo, Young-Sik;Kang, Mi-Hye;Andrew A. Randall
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.42-52
    • /
    • 2002
  • Two full-scale distribution systems, one treating water by ozonation and another treating water by nanofiltration in parallel with lime softening, were monitored for bacterial growth. Both systems kept disinfectant residuals surf as chlorine and chloramine in their respective distribution systems. Bacterial growth was assessed by heterotrophic plate counts (HPC) on R2A agar. In the distribution systems fed by ozonated water, HPCs were correlated ($R^2$= 0.97) using an exponential model with the assimilable organic carbon (AOC) at each sampling site. Also, it was observed that ozonation caused a significant increase in the AOC concentration of the distribution system (over 100% increase) as well as a significant increase in the bacterial counts of the distribution system (average increase over 100%). The HPCs from the distribution systems fed by nanofiltration in parallel with lime-softening water also displayed an exponential correlation ($R^2$ = 0.75) with an exponential model based on AOC. No significant correlation was found between bacteria growth on R2A agar and BDOC concentrations. Therefore, in agreement with previous work, bacterial growth in the distribution systems was found to correlate with AOC concentrations.

A Study on the Perception and Attitude towards Food Waste Reduction by the Elementary School Pupils (부산지역 초등학생들의 음식물쓰레기 감량에 대한 인식 및 태도 연구)

  • 김소희;류은순
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.6
    • /
    • pp.1155-1162
    • /
    • 2002
  • Food waste in school foodservices is an important factor in managing expense or evaluating the acceptance of served meals and a serious environmental hazard factor in all countries. In this study, the perception and attitude towards food waste reduction and the recognition of environmental pollution of students from elementary school foodservices in Busan, Korea were investigated. The questionnaire was responded by 519 students (boy: 255, girl: 264) in the third and sixth grades. School lunch programs were proved to contribute to the improvement of students' food intake habits. The perception and attitude towards food waste reduction of the third grade students (3.61/3.73) were significantly higher than those of the sixth grade students (3.46/3.59) (P<0.01). Food waste education made a significant impact on the perception and attitude on food waste (p<0.01). When dislike food was supplied the students having the higher perception and attitude towards food waste reduction ate it more than those having the lower perception and attitude. The major reason for plate waste was shown to be influenced by the taste and amount of foods supplied in school lunch programs. Most of students recognized that food waste pollution (4.22) was one of the severest problems among the environmental pollutions, followed by air (4.13), tap water (4.09) soil (3.78), noise (3.55) pollution. The students separated the garbage in the house (72.6%) better than in school and the outside (55.2%). The perception of food waste was positively correlated with the attitude toward reduction of food waste and the recognition of environmental pollution (p<0.01). The attitude toward reduction of food waste was also positively correlated with meal quantity taken (p<0.01).

A Study on the Selection of Compaction Method in Order to Utilize the Waste Landfill Selected Soils (폐기물매립장 선별토사 활용을 위한 다짐공법 선정에 관한 연구)

  • Nam, Hong-Ki;Lee, Seung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.8
    • /
    • pp.29-40
    • /
    • 2017
  • In this study, the dynamic compaction method was selected by analyzing field situation, soil condition data and compaction test characteristics of the special selected soils, and the compaction method for using the selected soils as the site restoration soil of the ${\bigcirc}{\bigcirc}$ city non-sanitary landfill maintenance project. The N value in the standard penetration test (SPT) before and after dynamic compaction increased by an average of 89% over the range 12~18, and the allowable bearing capacity of the plate bearing test (PBT) was ranged $150{\sim}227kN/m^2$, at least 80% higher than that before test. As a result, it can be seen that the same tendency as the dynamic compaction effect applied to the existing dredging and waste landfill is shown.

Synthesis of Barium Ferrite Powder by the Coprecipitation Method using Iron Pickling Waste Acid

  • Youngjae Shim;Kim, Dong-Whan;Kim, Guk-Tae
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.401-404
    • /
    • 2001
  • Barium ferrite powders were synthesized by the coprecipitation method using iron-pickling waste acid (IPWA) and BaCl$_2$$.$2H$_2$O as raw materials. Fe$\^$2+/ ions in the IPWA, which contains both Fe$\^$2+/ and Fe$\^$3+/ ions, were oxidized into Fe$\^$3+/ ions using H$_2$O$_2$. Proper amount of BaCl$_2$$.$2H$_2$O was dissolved into the oxidized IPWA. Using NaOH, Ba$\^$2+/ and Fe$\^$3+/ ions were coprecipitated as Ba(OH)$_2$and Fe(OH)$_3$. The coprecipitated Ba(OH)$_2$and Fe(OH)$_3$were washed and dried. Barium ferrite powders were obtained by calcining the dried Ba(OH)$_2$and Fe(OH)$_3$mixture from 400$\^{C}$ to 1000$\^{C}$ with a 100$\^{C}$ interval. Barium ferrite powders were characterized by X-ray diffraction, SEM, and VSM. It was found that barium ferrite powders could be synthesized at around 630$\^{C}$. The synthesized barium ferrite powders showed hexagonal plate shapes with a fairly uniform size. The barium ferrite powder calcined at 900$\^{C}$ showed good magnetic properties, saturation magnetization of 67emu/g and maximum coercivity of 5000 Oe.

  • PDF

Source Term Characterization for Structural Components in $17{\times}17$ KOFA Spent Fuel Assembly ($17{\times}17$ KOFA 사용후핵연료집합체내 구조재의 방사선원항 특성 분석)

  • Cho, Dong-Keun;Kook, Dong-Hak;Choi, Heui-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.347-353
    • /
    • 2010
  • Source terms of metal waste comprising a spent fuel assembly are relatively important when the spent fuel is pyroprocessed, because cesium, strontium, and transuranics are not a concern any more in the aspect of source term of permanent disposal. In this study, characteristics of radiation source terms for each structural component in spent fuel assembly was analyzed by using ORIGEN-S with a assumption that 10 metric tons of uranium is pyroprocessed. At first, mass and volume for each structural component of the fuel assembly were calculated in detail. Activation cross section library was generated by using KENO-VI/ORIGEN-S module for top-end piece and bottom-end piece, because those are located at outer core with different neutron spectrum compared to that of inner core. As a result, values of radioactivity, decay heat, and hazard index were reveled to be $1.40{\times}10^{15}$ Bequerels, 236 Watts, $4.34{\times}10^9m^3$-water, respectively, at 10 years after discharge. Those values correspond to 0.7 %, 1.1 %, 0.1 %, respectively, compared to that of spent fuel. Inconel 718 grid plate was shown to be the most important component in the all aspects of radioactivity, decay heat, and hazard index although the mass occupies only 1 % of the total. It was also shown that if the Inconel 718 grid plate is managed separately, the radioactivity and hazard index of metal waste could be decreased to 20~45 % and 30~45 %, respectively. As a whole, decay heat of metal waste was shown to be negligible in the aspect of disposal system design, while the radioactivity and hazard index are important.

Analysis of Falling-film Generator in Ammonia-water Absorption System (암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석)

  • 김병주;손병후;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF