• Title/Summary/Keyword: the magnetic wall cavity

Search Result 8, Processing Time 0.023 seconds

A Study on the Flow Analysis for Natural Convection of Magnetic Fluid in a Cubic Cavity (밀폐공간내 자성유체의 유동특성에 관한 연구)

  • Ryu, Shin-Oh;Park, Joung-Woo;Seo, Lee-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.142-147
    • /
    • 2001
  • Natural convection of a magnetic fluid is different from that of Newtonian fluids because magnetic body force exists in an addition to gravity and buoyancy. In this paper, natural convection of a magnetic fluids(W-40) in a cubic cavity is examined by numerical and experimental method. One side wall was kept at a constant temperature($25^{\circ}C$), and the opposite side wall was also held at a constant but lower temperature($20^{\circ}C$). Under above conditions, various magnitudes of the magnetic fields were applied up. GSMAC scheme is used for a numerical method, and the thermo-sensitive liquid crystal film(R20C5A) is utilized in order to visualize wall-temperature distributions as an experimental method. This study has resulted in the following fact that the natural convection of a magnetic fluids is controlled by the direction and intensity of the magnetic fields.

  • PDF

Experimental Analysis on the Heat Transfer Characteristics of Magnetic Fluids in a Cubic Cavity (자성유체의 밀폐공간내의 열전달 특성에 관한 실험적 연구)

  • Park, Joung-Woo;Seo, Lee-Soo;Chen, Chel-Ho;Park, Gil-Moon
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.3
    • /
    • pp.127-132
    • /
    • 2003
  • Natural convection of a magnetic fluid is different from that of Newtonian fluids because magnetic-body force exists in addition to gravity and buoyancy. In this paper, natural convection of a magnetic fluids (W-40) in a cubic cavity was examined by experimental method. One side wall was kept at a constant temperature (25 $^{\circ}C$), and the opposite side wall was also held at a constant but lower temperature (20 $^{\circ}C$). The magnetic fields of various magnitude were applied up and down by permanent magnets. We measured temperatures at 5 points which are the most suitable places in cavity by the analysis record. The thermo-sensitive liquid crystal film (R20C5A) was utilized in order to visualize wall-temperature distributions. Several kinds of experiments were carried out in order to clarify the influence of direction and intensity of magnetic fields on the natural convection. It was found that the natural convection of a magnetic fluids could be controlled by the direction and intensity of the magnetic fields.

Effect of a Magnetic Field on Mixed Convection of a Nanofluid in a Square Cavity

  • Sheikhzadeh, G.A.;Sebdani, S. Mazrouei;Mahmoodi, M.;Safaeizadeh, Elham;Hashemi, S.E.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.321-325
    • /
    • 2013
  • The problem of mixed convection in a differentially heated lid-driven square cavity filled with Cu-water nanofluid under effect of a magnetic field is investigated numerically. The left and right walls of the cavity are kept at temperatures of $T_h$ and $T_c$ respectively while the horizontal walls are adiabatic. The top wall of the cavity moves in own plane from left to right. The effects of some pertinent parameters such as Richardson number (ranging from 0.1 to 10), the volume fraction of the nanoparticles (ranging 0 to 0.1) and the Hartmann number (ranging from 0 to 60) on the fluid flow and temperature fields and the rate of heat transfer in the cavity are investigated. It must be noted that in all calculations the Prandtl number of water as the pure fluid is kept at 6.8, while the Grashof number is considered fixed at 104. The obtained results show that the rate of heat transfer increases with an increase of the Reynolds number, while but it decreases with increase in the Hartmann number. Moreover it is found that based the Richardson and Hartmann numbers by increase in volume fraction of the nanoparticles the rate of heat transfer can be enhanced or deteriorated compared to the based fluid.

MRI Findings of Obstructed Hemivagina and Ipsilateral Renal Agenesis (OHVIRA syndrome) with a Blind Megaureter: Case Report

  • Cho, Yun Hee;Sung, Deuk Jae;Han, Na Yeon;Park, Beom Jin;Kim, Min Ju;Sim, Ki Choon;Cho, Sung Bum
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.196-199
    • /
    • 2015
  • Obstructed hemivagina and ipsilateral renal anomaly (OHVIRA) syndrome is an uncommon congenital abnormality of the female urogenital tract characterized by the triad of uterine didelphys, obstructed hemivagina, and ipsilateral renal agenesis. A 13-year-old female presented with acute lower abdominal pain. Magnetic resonance imaging (MRI) revealed uterine didelphys, hematometrocolpos, obstructed hemivagina, and right ipsilateral agenesis, consistent with OHVIRA syndrome. Also, a well-defined mass with fluid signal intensity, mimicking adnexal neoplasm was seen in the right lower pelvic cavity adjacent to the posterior wall of the bladder. Vaginal septotomy and drainage of hematometrocolpos were done initially, but unilateral hysterectomy was later performed to relieve the patient's symptoms. The cystic mass in the right lower pelvic cavity was also excised and confirmed as a blind megaureter.

Material Analysis and Provenance Interpretation for Rock Properties of the Gwangjueupseong (Gwangju Town Wall), Korea (광주읍성 축성암석의 재질분석과 산지해석)

  • Lee, Myeong-Seong;Chun, Yu-Gun;Seo, Jeong-Seog;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.1
    • /
    • pp.61-76
    • /
    • 2009
  • Gwangjueupseong (Gwangju Town Wall) has been found in the site of the Asian Culture Complex (former Provincial Government of Jeonnam) by archaeological field survey. The length of the remaining wall is 85.1m, and the Town Wall consists of ten kinds of rock type. The major rock types are dacite (41.1%) and andesite (35.7%). Dacite composes main rock blocks of the wall, and andesite is used to fill the cavity between main rock blocks. These rocks look very similar to basement rocks of the Mudeung Mountain on the basis of occurrence features, magnetic susceptibility, petrological, mineralogical and geochemical properties. Also, quarrying traces were found on the southwestern slope of the mountain along the Jeungsimsa Temple valley. Thus, it is probable that the rock materials of the Gwangju Town Wall were supplied from the Mudeung Mountain and that they were transported along the Gwangju river.

  • PDF

A Numerically Efficient Full Wave Analysis of Circular Resonators Microbandes Stacked Involving Multimetallisations

  • Chebbara, F.;Fortaki, T.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.314-319
    • /
    • 2015
  • The conventional geometry of a plate microstrip resonator is made up of a single metallic patch, which is printed on a monolayer dielectric substrate. Its arrangement is simple and easy to make, but it is limited in its functional abilities. Many searches have been realized to improve the bandwidth and the gain of the microstrip resonators. Among the various configurations proposed in the open literature, the stacked geometry seems to be very promising. By appropriate design, it is able to provide the operation in dual frequency mode, wide bandwidth enough and high gain. The theoretical investigations of structures composed of two stacked anti-reflection coatings, enhanced metallic coatings are available in the literature, however, for the stacked configurations involving three metallic coatings or more, not to exact or approximate analysis was conducted due to the complexity of the structure.

Left Ventricular Pseudo-pseudoaneurysm with Hemopericardium

  • Kim, Hye-Seon;Kim, Kyung-Hwan;Hwang, Ho-Young
    • Journal of Chest Surgery
    • /
    • v.44 no.3
    • /
    • pp.247-249
    • /
    • 2011
  • We report a case of pseudo-pseudoaneurysm, which is a very rare complication of myocardial infarction. A 69-year-old man was admitted to our clinic with chest tightness and dyspnea. He had undergone aortic valve replacement with a pericardial bioprosthetic valve, ring mitral annuloplasty, and reconstruction of an aortic annular defect due to infective endocarditis with bovine pericardium 4 years prior. Echocardiography and computed tomography showed pericardial effusion and a 16-mm cavity at the anterolateral wall of the left ventricle. Magnetic resonance imaging suggested either pseudo-pseudoaneurysm or myocardial abscess. We successfully repaired the myocardial defect using a patch made from a vascular graft with pledgeted horizontal mattress sutures under cardiopulmonary bypass.

New Landmark for the Endoscopic Endonasal Transsphenoidal Approach of Pituitary Surgery

  • Kim, Young Ha;Kim, Ju Eun;Kim, Min Joo;Cho, Jin Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.4
    • /
    • pp.218-222
    • /
    • 2013
  • Objective : To clarify the anatomical correlations of the sphenoid sinus with surrounding structures in the normal Korean population, and to identify surgical landmarks for safe sellar floor dissection in the anterior skull base by endoscopy and microscopy. Methods : We reviewed the 196 brain magnetic resonance imaging findings showing a normal appearance, and measured the distances between anatomical landmarks. Results : The mean distances from the base of the columella to the anterior wall of the sphenoid sinus and the sellar floor were $69.71{\pm}4.25$ mm and $86.26{\pm}4.57$ mm, respectively in the over 15 age group, and showed the smallest degree of variation among the measurements. The mean angles between the floor of the nasal cavity and the straight line connecting the base of the columella and the sellar floor were $29.45{\pm}3.25^{\circ}$ and $24.75{\pm}4.00^{\circ}$ in the over 15 and under 15 age groups, respectively. The mean values of both distances and angles increased with age until 15 years after which no further increases were evident. There were no significant differences in the measurements between males and females or among subjects with different degrees of pneumatization in the over 15 age group. Conclusion : The distances from the base of the columella to the sellar floor and the anterior wall of the sphenoid sinus, which were consistent among individuals, could be used as a surgical indicator to investigate the sellar floor in endoscopic or microscopic transsphenoidal approaches.