• Title/Summary/Keyword: the joint angle

Search Result 1,437, Processing Time 0.029 seconds

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

Normal Range of Shoulder Motion and Fluoroscopic Analysis of Motion Fraction (정상인의 견관절 운동범위 및 방사선 투시기를 이용한 운동분율측정)

  • Choi Chang-Hyuk;Yun Gi-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.221-229
    • /
    • 1998
  • We measured, with manual goniometer, the active and passive arc of motion of the shoulder in 31 healthy male subjects who were right-hand dominant and who ranged in age from twenty to thirty-one years. Among ten directions through the four motion plane, the range of motion on the dominant side were significantly smaller than those on the non-dominant side in the motion of six directions. We also measured the motion fraction of the glenohumeral and scapulothoracic movement using fluoroscope in 30-degree intervals of arm elevation in the scapular plane. The ratio of glenohumeral to scapulothoracic movement(θGH/θST) was 1.6 for the full range of motion in scapular plane. At the lower angles of abduction, scapulothoracic movement was slight compared with glenohumeral movement. The motion fraction of scapulothoracic joint was increased from 60-degree to 150 degree of arm angle especially between 120 to 150 degree. During arm elevation, scapula was also extended from 42 degrees to 20 degrees tilting as well as internal rotation. The measuring technique of glenohumeral to scapulothoracic movement(θGH/θST) with fluoroscopy could be applied to the simple radiographic measurement at the out-patient clinic in order to identify the pathology and recovery of shoulder motion after treatment.

  • PDF

Effect of Different Drop Heights and Load on Lower Extremity Kinetics in Landing Task (착지 과제에서 낙하높이와 중량이 하지역학에 미치는 영향)

  • Hyun, Seunghyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.3
    • /
    • pp.115-121
    • /
    • 2021
  • Human's landing strategies have been explained through lower extremity kinetics in various conditions. However, how lower extremity kinetics respond when the two conditions between a load and landing height are combined is not yet understood. To achieve the purpose of this study, a total of 20 men and women were subjected to drop landing according to a load(No load, 10%, 20%, 30% of the body weight) at various landing heights(0.3 m, 0.4 m, 0.5 m). As a result of the study, the main effect of a load was not statistically significant in all variables. But increasing of the landing heights showed more flexion angle which was statistically significant in knee joint. In addition, as the landing height increased, the medial-lateral, anterior-posterior, vertical force, and loading rate increased, while time to peak vertical force decreased which was statistically significant. Thus, humans can successfully perform the landing motion even if the load is changed at various heights. However, it reacted more sensitively to the change in landing height than that load condition. The landing height can be prepared for recognition and shock absorption through visual information, but the weight level is difficult for the body to perceive and explains why it is more difficult to apply it to the landing strategy mechanism for shock absorption.

Strength Anisotropy through Artificial Weak Plane of Mudstone (인공연약면을 따른 이암의 강도이방성에 관한 연구)

  • Lee, Young-Huy;Jeong, Ghang-Bok
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.111-120
    • /
    • 2008
  • The characteristic of induced anisotropy is investigated in this study for the Pohang mudstone involving the cut plane discontinuity. The uniaxial and triaxial compression tests are performed for anisotropic rocks with artificial joint to look into anisotropic strength characteristics. Both the uniaxial compressive strength and triaxial compressive strength show the lowest value at the angle of cut plane, ${\beta}=30^{\circ}$ and the shoulder type of anisotropy is obtained. Anisotropy ratio (Rc) in uniaxial compression measures 9.0, whereas Rc=1.29-1.98 in triaxial compression is appeared. A series of analyses are made with the test results to derive the suitable parameter values when it is applied to the Ramamurthy (1985) failure criterion. The result of uniaxial compression test is analyzed by introducing the n-index into Ramamurthy failure criterion. The result shows that, n=l is suitable for ${\beta}=0^{\circ}{\sim}30^{\circ}$ and n=3 is suitable for ${\beta}=30^{\circ}{\sim}90^{\circ}$. To analyze the result of triaxial compression test by Ramamurthy failure criterion, anisotropy ratio in uniaxial compression test is added to Ramamurthy's equation and material constants are estimated by modified Ramamurthy's equation. When these values are applied back to Ramamurthy failure criterion, the predicted values are well fitted to the test results. And strength anisotropy for failure criteria of Jaeger (1960), McLamore & Gray (1967) and Hoek & Brown (1980) are also investigated.

A Study on the Interfacial Bonding in AlN Ceramics/Metals Joints: I. Residual Stress Analysis of AlN/Cu and AlN/W Joints Produced by Active-Metal Brazing (AlN 세라믹스와 금속간 계면접합에 관한 연구 : I. AlN/Cu 및 AlN/W 활성금속브레이징 접합체의 잔류응력 해석)

  • Park, Sung-Gye;Lee, Seung-Hae;Kim, Ji-Soon;You, Hee;Yum, Young-Jin
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.962-969
    • /
    • 1999
  • Elastic and elasto-plastic stress analyses of AlN/Cu and AlN/W pints produced by active-metal brazing method using Ag-Cu-Ti insert-metal were performed with use of Finite-Element-Method(FEM). The results of stress analyses were compared with those from the pint strength tests and the observations of fracture behaviors. It was shown that a remarkably larger maximum principal stress is built in the AlN/Cu pint compared to the A1N/ W joint. Especially, the stress concentration with tensile component was confirmed at the free surface close to the bonded interface of AlN/Cu. The elasto-plastic analysis under consideration of stress relaxation effect of Ag-Cu-Ti insert possessing a so-called 'soft-metal effect' showed that the insert leads to a lowering of maximum principal stress in AlNiCu pint, even though an increase of the insert thickness above 100$\mu\textrm{m}$ could not bring its further decrease. The maximum pint strengths measured by shear test were 52 and 108 MPa for AlNiCu and AlN/W pints. respectively. Typical fractures of AlN/Cu pints occurred in a form of 'dome' which initiated from the free surface of AlN close to the bonded interface and proceeded towards the AlN inside forming a large angle. AlN/W pints were usually fractured at AlN side along the interface of AlN/insert-metal.

  • PDF

Kinematical Analysis of Lopez Motion in Horse Vault: Comparison between Successful and Failed Trials (도마 Lopez 동작의 운동학적 분석: YHS 선수의 성공과 실패 사례 비교)

  • Park, Cheol-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.167-174
    • /
    • 2020
  • The purpose of this study was to investigate the kinematic comparison between successful and failed trials of Lopez vault techniques in male gymnastics. The subject, an Olympic gold medalist, was YHS (age: 27 years, height: 1.6 m, and mass: 53 kg) and fourteen high speed motion capturing cameras were used for data collection. The 26 reflective sensors were attached on major anatomical positions and 15 segment-body model was used to calculate the kinematic variables. According to results, the contact duration of the spring-board for successful trial(ST) was longer and that of failed trial(FT) and the range of motion of knee joint for ST was greater than that of FT. The movement times during pre-flight between ST and FT were same, but the movement time of horse contact period for ST was shorter than that of FT. The ST showed a longer movement time during post-flight and the longer horizontal distance than those of FT. Conclusively, YHS needs to approach the horse with a higher position of the body and higher incidence angle, as well as make faster twist angular velocity in an attempt to achieve ST.

Influence of internal connection length on screw loosening in internal connection implants (내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향)

  • Kim, Ji-Sun;Park, Young-Bum;Choi, Hynmin;Kim, Sungtae;Kim, Hyeon Cheol;Kim, Sun Jai;Moon, Hong-Seok;Lee, Jae-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.251-257
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate whether the internal abutment length affected screw stability in an internal connection implant. Materials and methods: Twenty long internal connection implants (Replus system, $4.7{\times}11.5mm$) were selected for this investigation. Abutments were assigned to four groups depending on the length of the internal connection (abutments with internal lengths of 1, 2, 3, and 4 mm, respectively). Each implant fixture specimen was embedded in resin medium and connected to an abutment with an abutment screw. A load of 100 N, applied at an angle of $30^{\circ}$ to the long axis of the implant, was repeated for $1.0{\times}10^6$ cycles. Reverse torque values (RTV) were recorded before and after loading, and the change in RTV was calculated. Data were analyzed with the Kruskal-Wallis test. Results: The change in RTV was not significantly different among the groups (P>.05). Screw loosening and fractures were not observed in any groups, and joint stability was maintained. Conclusion: The internal length of the abutment may not significantly affect the degree of screw loosening.

Study on Analysis for Factors Inducing the Whangryeong Mountain Landslide (황령산 산사태 원인 분석에 대한 연구)

  • 최정찬;백인성
    • The Journal of Engineering Geology
    • /
    • v.12 no.2
    • /
    • pp.137-150
    • /
    • 2002
  • Recently, plane failure mode occurred frequently along the bedding plane having low angle dip about 20 degree when cutting slopes were constructed in sedimentary rock region of the Gyeongsang Basin. Landslide of the Whangryeong Mountain which was occurred at Busan Metropolitan City in 1999 belongs to the category mentioned above. Reconstruction for cutting slope of the Whangryeong Mountain has finished in 2000 and final grade of reconstructed cutting slope is 1:2.0. To analyze slope failure mode for landslide of the Whangryeong Mountain, various analyses were performed such as in-situ investigation and test, drilling, laboratory test, aerial photograph interpretation, X-ray diffraction analysis, and slope stability analysis using Stereographic Projection and Limit Equilibrium methods. As the result, it is identified that tension cracks had been developed one year before the landslide took place. The tension crack semis to be formed by merging several joint sets. It appears that failure blocks broke down along the sliding planes of different layers. Risk of plane failure is conformed as a result of stability analysis using Stereographic Projection and Limit Equilibrium methods in case that greenish gray tuffaceous shales, regared as sliding planes, are weathered. From now on, a detailed investigation is needed for the thin layers which is sensitive to weathering, and stability analysis for this layer is performed at cut slope construction site having similar geological condition.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

A study on the sleeve-shaped platform of POF-based joint angle sensor for arm movement-monitoring clothing (인체동작 모니터링 위한 광섬유 기반 의류 소매형 동작센서 연구)

  • Kang, Da-Hye;Lee, Young-Jae;Lee, Jeong-Whan;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.221-226
    • /
    • 2011
  • Although diverse researches on sensing method of human movement have been performed, there are still many limitations to the existing methods. As a part of supplementing the limitations to the existing motion sensing methods, this study aimed to execute an exploratory examination on a POF-based sleeve-shaped motion sensor for less restrictive sensing of human movement. In this study, a set of POF-based motion sensor, which was embedded in a sleeve-shaped platform was devised, and a set of exploratory experiments was performed on the possibility of sensing of human movement as diverse as in daily life, through this device. The scope of this research was limited to an exploration on the possibility and basic elements of POF-based sleeve-shaped motion sensor, while the influence of sleeve patterns, those of wearer's somatotype, those of sewing method were not studied in this study. When compared to the pre-existing methods, the POF-based motion sensor platformed on sleeve in this study, which was purposively devised to be applied to the motion sensing clothing shows some beneficial characteristics : more sensitive measurement on human motion, low cost, no timely restriction in sensing, no request for gigantic apparatus and space for sensing.

  • PDF