• 제목/요약/키워드: the independent film

Search Result 234, Processing Time 0.022 seconds

The Satisfaction Factors Affect the Recommendation Intention and Rewatching Intention of Watching Musicals through Online Platforms : Focus on the Moderating Effects of Audience's Degree of Involvement to Musicals (온라인 플랫폼 뮤지컬 관람 방식의 추천 의도 및 재관람 의도에 영향을 미치는 만족 요인 : 뮤지컬 관여도의 조절 효과를 중심으로)

  • Yoon, Hyeong-Yeol
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.131-143
    • /
    • 2021
  • In this study, the factors influencing the satisfaction of the online platform musical viewing method were investigated, and the effect of the satisfaction factors on the recommendation intention and rewatching intention of the online platform viewing method for musicals was investigated. In addition, the effect of the survey subjects' degree of involvement to musicals between the satisfaction of the online platform-based musical viewing method and recommendation intention, and rewatching intention was investigated. Satisfaction factors of online platform musicals, which are independent variables, were classified into image quality, convenience, economy, and interactivity, and dependent variables were classified into recommendation intention and rewatching intention of online platform musicals, and moderator variable was set to degree of involvement to musicals, and a total of 20 hypotheses were established. An online survey was conducted on 1,454 audiences who had experience watching musicals through the online platform from August 28 to September 7, 2021, and a total of 1,418 answers were used as valid samples. As a result of the analysis, the factors that make up the satisfaction of online platform musicals appeared in the order of convenience, video quality, economics, and interactivity. It was found that the satisfaction level of watching online platform musicals had a positive effect on the intention to recommend and rewatching online platform musicals in the path of all satisfaction factors. It was found that the moderating effect of the audience's involvement in musicals between online platform musical viewing satisfaction and recommendation intention and rewatching intention had a significant effect only between image quality and recommendation intention. It shows that audiences with high involvement in musicals have intention to recommend only when they are satisfied with the video quality of online platform musicals. Particularly important point is that the convenience factor was found to have the greatest influence on the satisfaction of online platform musical viewing method, but the image quality factor was found to have the greatest influence on the recommendation intention and rewatching intention of online platform musicals.

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

Dose Verification Study of Brachytherapy Plans Using Monte Carlo Methods and CT Images (CT 영상 및 몬테칼로 계산에 기반한 근접 방사선치료계획의 선량분포 평가 방법 연구)

  • Cheong, Kwang-Ho;Lee, Me-Yeon;Kang, Sei-Kwon;Bae, Hoon-Sik;Park, So-Ah;Kim, Kyoung-Joo;Hwang, Tae-Jin;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • Most brachytherapy treatment planning systems employ a dosimetry formalism based on the AAPM TG-43 report which does not appropriately consider tissue heterogeneity. In this study we aimed to set up a simple Monte Carlo-based intracavitary high-dose-rate brachytherapy (IC-HDRB) plan verification platform, focusing particularly on the robustness of the direct Monte Carlo dose calculation using material and density information derived from CT images. CT images of slab phantoms and a uterine cervical cancer patient were used for brachytherapy plans based on the Plato (Nucletron, Netherlands) brachytherapy planning system. Monte Carlo simulations were implemented using the parameters from the Plato system and compared with the EBT film dosimetry and conventional dose computations. EGSnrc based DOSXYZnrc code was used for Monte Carlo simulations. Each $^{192}Ir$ source of the afterloader was approximately modeled as a parallel-piped shape inside the converted CT data set whose voxel size was $2{\times}2{\times}2\;mm^3$. Bracytherapy dose calculations based on the TG-43 showed good agreement with the Monte Carlo results in a homogeneous media whose density was close to water, but there were significant errors in high-density materials. For a patient case, A and B point dose differences were less than 3%, while the mean dose discrepancy was as much as 5%. Conventional dose computation methods might underdose the targets by not accounting for the effects of high-density materials. The proposed platform was shown to be feasible and to have good dose calculation accuracy. One should be careful when confirming the plan using a conventional brachytherapy dose computation method, and moreover, an independent dose verification system as developed in this study might be helpful.

Heterogeneous Oxidation of Liquid-phase TCE over $CoO_x/TiO_2$ Catalysts (액상 TCE 제거반응을 위한 $CoO_x/TiO_2$ 촉매)

  • Kim, Moon-Hyeon;Choo, Kwang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.253-261
    • /
    • 2005
  • Catalytic wet oxidation of ppm levels of trichloroethylene (TCE) in water has been conducted using $TiO_2$-supported cobalt oxides at a given temperature and weight hourly space velocity. 5% $CoO_x/TiO_2$ might be the most promising catalyst for the wet oxidation at $36^{\circ}C$ although it exhibited a transient behavior in time on-stream activity. Not only could the bare support be inactive for the wet decomposition reaction, but no TCE removal also occurred by the process of adsorption on $TiO_2$ surface. The catalytic activity was independent of all particle sizes used, thereby representing no mass transfer limitation in intraparticle diffusion. Characterization of the $CoO_x$ catalyst by acquiring XPS spectra of both fresh and used Co surfaces gave different surface spectral features of each $CoO_x$. Co $2p_{3/2}$ binding energy of Co species exposed predominantly onto the outermost surface of the fresh catalyst appeared at 781.3 eV, which is very similar to the chemical states of $CoTiO_x$ such as $Co_2TiO_4$ and $CoTiO_3$. The spent catalyst possessed a 780.3 eV main peak with a satellite structure at 795.8 eV. Based on XPS spectra of reference Co compound, the TCE-exposed Co surfaces could be assigned to be in the form of mainly $Co_3O_4$. XRD measurements indicated that the phase structure of Co species in 5% $CoO_x/TiO_2$ catalyst even before reaction is quite comparable to the diffraction lines of external $Co_3O_4$ standard. A model structure of $CoO_x$ present on titania surfaces would be $Co_3O_4$, encapsulated in thin-film $CoTiO_x$ species consisting of $Co_2TiO_4$ and $CoTiO_3$, which may be active for the decomposition of TCE in a flow of water.