• Title/Summary/Keyword: the health problem of the aged

Search Result 293, Processing Time 0.179 seconds

Factors affecting the Organizational Commitment of Industrial Accident Hospital Employees by Job Category (병원 구성원들의 직종별 조직몰입의 영향요인에 관한 연구)

  • Bang, Yong-Joo;Ha, Ho-Wook;Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.7 no.4
    • /
    • pp.24-56
    • /
    • 2002
  • The purpose of this study was to analyze the characteristics of socio-demographic, organizational culture, organizational conflict and organizational commitment, and to examine the interrelation of influential factors in the organizational commitment. The data for this study were collected through a self-administrated survey with a structured questionnaire to 1,027 subjects from several medical doctor staff members, nursing staff members, administration staff members, pharmacist, and technical expert of eleven hospitals. The data were collected by self-reporting questionnaire from July 29 to September 7, 2002. In this analysis frequency test, t-test, ANOVA, multiple regression were used. The main results of this research is as following; 1. According to socio-demographic characteristics the respondents' level of the organizational commitment was higher in a administration staff members than others, for males than females, and for employees aged more than forty, as working for longer time, and as higher level of the working position. 2. According to the organizational culture characteristics the progressive culture, affiliative culture, and task-focused culture among many types of organizational culture were moderately and positively correlated with the level of the organizational commitment while the hierarchical culture was negatively correlated. 3. According to the organizational conflict characteristics as the respondents who got less conflict experience in the organization, their level of the organizational commitment was higher. And, technical conflict experiences were expressed greater than hierarchical conflict experiences. 4. According to the job satisfaction characteristics as his or her satisfaction that is about the promotion, working itself, salary, and fellowship in the organizational was higher, the level of the organizational commitment was higher. The most important factor of the satisfactions was the fellowship among the respondents while the level of job satisfaction for the promotion and salary was average. 5. Overall, according to the result of Multiple Regression as older age and longer working hours, the level of the organizational commitment was higher and as a higher level of the satisfaction for the promotion, working itself, salary, and fellowship in the organization, it caused more effective factors for the organizational commitment. 6. According to the result of Multiple Regression for the doctor staff members in special hospitals rather than general hospitals the hierarchical culture and task focused culture was positively correlated with the satisfaction of working itself while hierarchical conflict factors in the organizational conflict characteristics was negatively correlated with the organizational commitment. For the nursing staff members the affiliative culture and the job satisfaction for the promotion, working itself, salary, and fellowship were positively correlated with the organizational commitment. For the administration staff members as the job satisfaction for the fellowship was positively correlated with the organizational commitment. For medical and pharmacy staff members as more working experience, correlation with the organizational commitment was positive. Besides, as he or she has a high perception of the affiliative culture, it caused statistically more effective factors for the organizational commitment. For the skill and technicians, male worker expressed greater organizational commitment in the organization than female worker. And also older age along with higher education also showed higher organizational commitment. Moreover, the job satisfaction for the fellowship was positively correlated with the organizational commitment. This study identified the major effective factors of the organizational commitment and analyzed the differences among the job category. In that respect, it is significant for the study to be able to provide a reference for managing hospital of industrial accident and organizational development. However, this study has a problem, which is not to identify a valuable model for examining the relationship between organizational factors such as organizational culture, conflict, satisfaction, and commitment. Therefore, further study is needed and strengthened in the field of organizational commitment for hospital for industrial accident.

  • PDF

Evaluation of Food and Nutrient Intake of Preschool Children in Day -Care Centers (보육시설 유아들의 식품 및 영양소 섭취상태 평가)

  • Sin, Eun-Kyung;Lee, Yeon-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.1008-1017
    • /
    • 2005
  • The purpose of this study was to evaluate the Quantity and Quality of food and nutrient intake of preschool children. The subjects were 57 children aged 3 to 6 years in Gumi day-care centers. Total daily dietary intakes were calculated by weighing food consumed at the day-care centers taken together with dietary records by children's mothers for intakes at home. This survey was conducted during 3 days including week and weekend days. Diet Quality was assessed by NAR (Nutrient Adequacy Ratio), MAR (Mean Adequacy Ratio), food group pattern and DDS (Dietary Diversity Score). The daily food intake was 992.7g, the plant food intake $(68\%)$ was higher than animal food intake $(32\%)$. The daily energy intake was 1249.2 kcal $(85\%\;RDA)$ and protein 43.8g $(153.6\%\;RDA)$. Percentage of calcium, iron, and niacin consumed below $75\%$ of RDAs were $29.8\%,\;35.1\%\;and\;28.1\%$, respectively. Proportions of energy from carbohydrate, protein and fat were $61.0\%,\;14.1\%\;and\;25.5\%$, respectively. Calorie intake proportion of breakfast, lunch, dinner and snack were $15\%,\;20\%,\;19\%\;and\;46\%$, respectively. The NAR of Ca and Fe and MAR were 0.84, 0.85 and 0.92, respectively. Thirty-one point six percent of children consumed 5 food groups (GMFVDS=110111) per day. Persons who had higher DDSs correlated positively with NAR and MAR. As a result, dietary intake of preschool children partially showed a problem of over and under nutrition in Quantity or Quality. We hope that the result of this study could be helpful for developing the nutrition education program for the health and nutrition of preschool children.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF