• 제목/요약/키워드: the ground vibrations

검색결과 162건 처리시간 0.024초

터널굴착에서 다단식 발파기에 의한 전단면 발파의 적용성 연구 (Application of Full-Face Round by Sequential Blasting Machine in Tunnel Excavation)

  • 조영동;이상은;임한욱
    • 화약ㆍ발파
    • /
    • 제13권1호
    • /
    • pp.20-31
    • /
    • 1995
  • Many methods and techniques to reduce ground vibrations are well known. Some of them are to adopt electric milisecond detonators with a sequential blasting machine or an initiating system with an adequate number of delay intervals. The types of electric detonators munufactured in Korea include instantaneous, decisecond and milisecond delays byt numbers of delay intervals are only limite from No.1 to No.20 respectively. It is not sufficient to control accurately milisecond time with these detonators in tunnel excavation. Sequential fire time refers to adding an external time delay to a detonators norminal firing time to obtain sequential initiation and it is determined by sequential timer setting. To reduce the vibration level, sequential blasting machine with decisecond detonatore was adopted. A total of 134 blasting was recorded at various sites. Blast-to-structure distances ranged from 20.3 to 42.0 meter, where charge weight varied from 0.25 to 0.75 kg per delay. The results can be summarized as follow : 1. The effects of sequential blasting machine on the vibration level are discussed. The vibration level by S.B.M. are decreased approximately 14.38~18.05 to compare to level of conventional blasting and cycle time per round can be saved. 2. The empirical equations of particle velocity were obtained in S,B.M. and conventional blastin. $V=K(D/W^{1/3})-n$. where the values for n and k are estimated to be 1.665 to 1.710 and 93.59 to 137 respectively. 3. The growth of cracks due to vibrations are found but the level fall to within allowable value.

  • PDF

철도 차량의 지반진동에 의한 주행안전성 평가 (Running Safety Analysis of Railway Vehicle Systems for Ground Vibration)

  • 최준성;조만섭;이진무
    • 터널과지하공간
    • /
    • 제16권4호
    • /
    • pp.288-295
    • /
    • 2006
  • 본 연구에서는 발파 및 지진발생으로 인한 횡방향 지반진동에 대하여 KTX 차량 및 부산지하철을 대상으로 주행안전성을 평가하였다. 이를 위하여 휠/레일 상호작용 해석 WERIA프로그램인 프로그램을 이용하여 철도차량의 동적거동을 시뮬레이션 하였다. 또한 횡방향 지반진동이 철도차량에 유발할 수 있는 차륜/레일간의 큰 상대변위를 고려하기 위하여 차륜/레일간 접촉면의 기하학적 형상과 크리프힘을 반영하였다. 입력하중은 국내의 내진규정 특성에 부합하는 인공지진과 공사중 발생하는 발파진동을 사용하였다. 해석 결과 차륜/레일간의 상대변위와 탈선계수를 산정하여 철도 차량의 주행안전성을 평가한 결과 탈선가능성은 없는 것으로 나타났다.

도심지(都心地) 발파(發破)에서의 지반진동(地盤振動) 측정(測定)에 관(關)한 연구(硏究) (A study on Measurement of Blast-Induced Ground Vibrations in Urban Areas)

  • 김웅수;이경운;임한욱;서백수
    • 산업기술연구
    • /
    • 제3권
    • /
    • pp.17-26
    • /
    • 1983
  • The blast vibrations were measured from 10 places through Seoul subway area to study their effects on the structures and to establish the safe blasting limits. For purpose of the present study, particle velocity only was recorded and analyzed, because it correlated most directly with damage. The results are as follows: (1) The proagation equation, $V=K(D/W^{1/3})^{-n}$ was obtained. Typical values could be found for n range from 1.7 to 1.5 and for k range from 48 to 138. (2) From the relationship between schmidt hammer rebound hardness and uniaxial compressive strength, $Sc=0.514{\times}(S.H)^{0.23}$, the compressive strength at any area can be assumed. (3) The use of AN-FO and other explosives with low detonation pressure may reduce vibration levels generated.

  • PDF

Nonlinear optimal control for reducing vibrations in civil structures using smart devices

  • Contreras-Lopez, Joaquin;Ornelas-Tellez, Fernando;Espinosa-Juarez, Elisa
    • Smart Structures and Systems
    • /
    • 제23권3호
    • /
    • pp.307-318
    • /
    • 2019
  • The frequently excessive vibrations presented in civil structures during seismic events or service conditions may result in users' discomfort, or worst, in structures failure, producing economic and even human casualties. This work contributes in proposing the synthesis of a nonlinear optimal control strategy for semiactive structural control, with the main characteristic that the synthesis considers both the structure model and the semiactive actuator nonlinear dynamics, which produces a nonlinear system that requires a nonlinear controller design. The aim is to reduce the unwanted vibrations in the response of civil structures, by means of intelligent fluid semiactive actuator such as the Magnetorheological Damper (MRD), which is a device with a low level of power consumption. The civil structures for which the proposed control methodology can be applied are those admitting a state-dependent coefficient factorized representation model, such as buildings, bridges, among others. A scaled model of a three storey building is analyzed as a case study, whose dynamical response involves displacement, velocity and acceleration of each one of the storeys, subjected to the North-South component of the September 19th., 2017, Puebla-Morelos (7.1M), Mexico earthquake. The investigation rests on comparing the structural response over time for two different conditions: with no control device installed and with one MRD installed between the first floor and the ground, where a nonlinear optimal signal for the MRD input voltage is determined. Simulation results are presented to show the effectiveness of the proposed controller for reducing the building's dynamical response.

VSimulators: A New UK-based Immersive Experimental Facility for Studying Occupant Response to Wind-induced Motion of Tall Buildings

  • Antony Darby;James Brownjohn;Erfan Shahabpoor;Kaveh Heshmati
    • 국제초고층학회논문집
    • /
    • 제11권4호
    • /
    • pp.347-362
    • /
    • 2022
  • Current vibration serviceability assessment criteria for wind-induced vibrations in tall buildings are based largely on human 'perception' thresholds which are shown not to be directly translatable to human 'acceptability' of vibrations. There is also a considerable debate about both the metrics and criteria for vibration acceptability, such as frequency of occurrence or peak vs mean vibration, and how these might vary with the nature of the vibration. Furthermore, the design criteria are necessarily simplified for ease of application so cannot account for a range of environmental, situational and human factors that may enhance or diminish the impact of vibrations on serviceability. The dual-site VSimulators facility was created specifically to provide an experimental platform to address gaps in understanding of human response to building vibration. This paper considers how VSimulators can be used to inform general design guidance and support design of specific buildings for habitability, in terms of vibration, which allow engineers and clients to make informed decisions with regard to sustainable design, in terms of energy and financial cost. This paper first provides a brief overview of current vibration serviceability assessment guidelines, and the current understanding and limitations of occupants' acceptability of wind-induced motion in tall buildings. It then describes how the dual-site VSimulators facility at the Universities of Bath and Exeter can be used to assess the effects of motion and environment on human comfort, wellbeing and productivity with examples of how the facility capabilities have been used to provide new, human experience based experimental research approaches.

지반 탁월주기와 지반 운동특성에 관한 연구 (A Study on Predominant Periods and Attenuation Characteristics of Ground Motion)

  • 김소구;차정식;정형식
    • 한국지반공학회지:지반
    • /
    • 제11권2호
    • /
    • pp.139-156
    • /
    • 1995
  • 지반진동특성의 지진공학적인 정밀측정의 일환으로 지반진동의 탁월주기와 지반진동의 거리에 따른 감쇠특성을 현장실험을 통하여 조사하였다. 이 조사는 세가지 부분의 실험을 통하여 결과를 얻었다. 첫째, 지반의 탁월주기는 고감도 디지탈 속도지진계-3축성분 속도계를 이용하는 Seismometer와 디지탈 Seismograph를 이용하여 지반과 건물에서 일정한 주기를 가진 연속적인 미소진동으로 부터 지반 및 건물진동의 탁월주기를 계측하였다. 지반에서의 탁월주기는 0.18~0.23 sec, 건물2층의 탁월주기는 0.26~0.31 sec였다. 둘째, 지반 구조조사는 디지탈 탄성파탐사기를 이용하여 굴절법을 이용한 탄성파탐사를 실시하였다. 실험장소인 한양대학교 안산캠퍼스의 지층구조는 상부층(표토층: surface layer)은 저속도층으로서 662m1s, 하부층(지반층: base ground)은 2210m/s의 P파 속도를 갖고, 주시곡선도로부터 표토층의 두께는 약 7m로 검측되었다. 이것은 7m두깨의 표토층(top soil)과 그 하부에 사질 점토성의 지반층(base ground)이 존재함을 암시한다. 셋째, Seisgun을 이용하여 인공적인 탄성파 에너지원을 만들어 지반의 진동 감쇠특성을 조사 하였다. 거리 감쇠상수(spatial attenuation conf$\ulcorner$icient) Y는 거리에 따른 진폭 을 계산하여 Z-성분(vertical)은 0.0137, X-성분(longitudinal)은 0.0025, Y-성분(transverse)은 0.0290이고 Spatial QP의 값은 각각 5.913~7.575, 32.371 ~41.452, 2.794~3.579의 값이 산출되었었다. 이 결과 다른 두성분에 비해서 종방향(z-성분, longitudinal)성분은 감쇠경향이 낮음을 알 수 있다. 그러므로 이 경우에 구조물 설계시 종방향(x-성분, longitudinal)성분에 대 한 내진설계가 고려 되어야 할 것이다.

  • PDF

고위력 폭약의 석회암 내 장약공 폭발에 의한 지반진동 전파특성에 관한 연구 (Propagation Characteristics of Ground Vibration Caused by Blast Hole Explosion of High Explosives in Limestone)

  • 김경규;신찬휘;김한림;양주석;배상호;윤경재;조상호
    • 화약ㆍ발파
    • /
    • 제41권4호
    • /
    • pp.17-28
    • /
    • 2023
  • 최근 연구시설 및 자원개발 등의 목적으로 지하공간 활용이 증가하고 있으며, 저심도 암반을 넘어 고심도 암반에 대한 개발이 증가하고 있다. 고심도 지하공간 개발은 높은 응력과 높은 온도 조건에서의 암반의 안정성을 고려해야 한다. 고심도의 경우 암반 구조와 불연속면의 상태 등이 안정성에 영향을 미칠 뿐만 아니라 지진 및 굴착을 위한 암반발파에 의한 지반진동 전파가 지하공동의 응력변화를 발생시켜 암반의 안정성에 영향을 미치게 된다. 발파공학 측면에서 지반진동을 예측하는 방법은 실측 데이터를 바탕으로 통계학적 회귀분석을 통한 경험적 회귀모형과 수치해석적 방법이 사용되고 있다. 본 연구에서는 단일공 발파에 의한 폭발압력 전파특성과 지반진동 전파특성에 대한 경험적 회귀모형을 획득하기 위하여 실험적 방법을 통해 연구를 수행하였다.

제어발파설계에서 자승근 및 삼승근 환산거리 기법의 적용한계에 대한 고찰 (Consideration on Limitations of Square and Cube Root Scaled Distances in Controled Blast Design)

  • 최병희;류창하;정주환
    • 화약ㆍ발파
    • /
    • 제28권1호
    • /
    • pp.27-39
    • /
    • 2010
  • 측정된 지반진동의 최대입자속도 자료에 대한 통계분석을 통해 환산거리 개념에 기초한 제어발파 설계조건식은 구할 수 있다. 이들 설계조건식들은 안전발파를 위한 다양한 허용기준에 따라 사용할 수 있는 환산거리의 최소값을 정의하는 형태로 되어 있다. 국내에서 널리 사용되는 환산거리에는 자승근 환산거리(SRSD)와 삼승근 환산거리(CRSD)의 두 가지가 있다. 따라서 SRSD와 CRSD의 설계조건식들은 각각 $D/\sqrt{W}{\geq}30m/kg^{1/2}$$D/\sqrt[3]{W}{\geq}60m/kg^{1/3}$의 형태가 된다. 제어발파 설계 시에는 이들 조건식들과 이격거리를 알고 있으므로 지반진동에 대해 구조물의 안정을 보장할 수 있는 최대 지발당장약량를 계산할 수 있다. 그러나 SRSD와 CRSD의 최대 지발당장약량은 각각 $W=O(D^2)$$W=O(D^3)$의 차원으로 나타난다. 따라서 SRSD에 비해 CRSD의 장약량은 두 회귀식의 유사한 적합도에도 불구하고 두 함수의 교점을 지나면 기하급수적으로 증가하게 된다. 따라서 본 논문에서는 CRSD의 지나치게 많은 장약량으로 인해 발생할 지도 모를 구조물의 피해를 방지하기 위해 CRSD는 어떤 특정한 거리 이내에서만 사용하도록 제한한다. 그 정확한 한계는 SRSD와 CRSD의 장약량 차가 교점 이내에서의 양자 간의 최대차를 초과하기 시작하는 점까지이다.

파시르 탄광에서의 채탄발파공법에 대한 문제점 분석 및 개선방안 연구 (A Study on the Improvement of Surface Blasting Method in Pasir Coal Mine)

  • 최병희;류동우;선우춘
    • 화약ㆍ발파
    • /
    • 제24권1호
    • /
    • pp.57-62
    • /
    • 2006
  • 인도네시아 파시르 탄광에서는 전형적으로 일자유면 발파방법이 사용되고 있다. 일자유면 발파방법은 지표면을 유일한 자유면으로 한 발파법이므로 구속이 커서 화약의 에너지가 저항선의 파괴보다는 지반진동의 유발에 더 많이 소모된다 따라서 파시르 탄광에서 현재 적용되는 일자유면 발파방법은 노천광산에서 일반적으로 적용되는 이자유면 발파인 계단발파에 비해 더 큰 지반진동을 유발시킬 수 있다. 더욱이 파시르 탄광의 경우 노천채굴적의 양안이 연약사면으로 이루어져 있어 발파진동은 이들 사면들의 안정성에 큰 영향을 미칠 수 있다. 발파진동과는 별도로 일자유면 발파는 본래 저항선이 하나뿐이므로 암반파괴의 측면에서도 발파효율이 좋지 않다. 따라서 파시르 탄광이 안고 있는 현안문제를 해결할 목적으로 진동제어와 발파효율을 동시에 향상시킬 수 있는 새로운 발파공법에 대한 연구가 착수되었다. 이 연구의 일환으로 파시르 탄광에서의 현행 발파공 법과 광산개발에 대한 현장조사가 수행되었으며 / 본 논문에서는 현장조사 과정에서 얻어진 결과들 가운데 향후 새로운 발파공법으로의 전환과정에서 반드시 준수되어야 할 공법설계의 지침을 제시하였다.

Comparing fuzzy type-1 and -2 in semi-active control with TMD considering uncertainties

  • Ramezani, Meysam;Bathaei, Akbar;Zahrai, Seyed Mehdi
    • Smart Structures and Systems
    • /
    • 제23권2호
    • /
    • pp.155-171
    • /
    • 2019
  • In this study, Semi-active Tuned Mass Dampers (STMDs) are employed in order to cover the prevailing uncertainties and promote the efficiency of the Tuned Mass Dampers (TMDs) to mitigate undesirable structural vibrations. The damping ratio is determined using type-1 and type-2 Fuzzy Logic Controllers (T1 and T2 FLC) based on the response of the structure. In order to increase the efficiency of the FLC, the output membership functions are optimized using genetic algorithm. The results show that the proposed FLC can reduce the sensitivity of STMD to excitation records. The obtained results indicate the best operation for T1 FLC among the other control systems when the uncertainties are neglected. According to the irrefutable uncertainties, three supplies for these uncertainties such as time delay, sensors measurement noises and the differences between real and software model, are investigated. Considering these uncertainties, the efficiencies of T1 FLC, ground-hook velocity-based, displacement-based and TMD reduce significantly. The reduction rates for these algorithms are 12.66%, 26.43%, 20.98% and 21.77%, respectively. However, due to nonlinear behavior and considering a range of uncertainties in membership functions, T2 FLC with 7.2% reduction has robust performance against uncertainties compared to other controlling systems. Therefore, it can be used in actual applications more confidently.