• Title/Summary/Keyword: the brain power

Search Result 301, Processing Time 0.036 seconds

DEVELOPMENT OF THE GRAFTING ROBOT FOR CUCUMBER SEEDLINGS

  • Suzuki, Masato;Onoda, Akihiko;Kobayashi, Ken
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.859-866
    • /
    • 1993
  • With the object of doing mechanical grafting of cucurbitaceous vegetables, the grafting robot was developed in 1989. This robot consists of the following components : feeding wheels, grippers, conveying wheels, cutters , fixing clipper, discharger , controller and power supply. One cycle time to produce a grafted plant is about 3 seconds, Results of some cucumber grafting tests : successful grafting rate of 98 percent and after acclimation, a successful agglutination rate of 95 percent. These techniques are now transferring to the private company. The commercial robot will come into the market in this year.

  • PDF

Changes of Electroencephalogram according to Contraction Training Methods of Tibialis Anterior Muscle in Healthy Women (정상 여성에게서 앞 정강근의 수축훈련방법에 따른 뇌파의 변화)

  • Lee, Jeong-Woo;Kim, Moon-Jeong;Yoon, Se-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.127-133
    • /
    • 2012
  • Purpose: This study aims to examine the power changes in eletrocenphalogram (EEG) detected from the tibialis anterior muscle, during repetitive contraction exercise in normal female adults. Methods: The subjects of this study were 24 normal adult females, with no musculoskeletal or nervous system disorders. The 24 female subjects were divided into two groups: 12 subjects comprised a voluntary stimulation training group, and the other 12 subjects comprised an electrical stimulation training group. A total of thirty contractions were made repetitively by each woman, with maximal voluntary contraction exercise for six seconds, and a resting time of three seconds. During the experiment, their EEG was measured at eight positions. The eight positions were Fpz, Fz, Cz, CPz, C3, C4, P3, and P4, in accordance with the international 10~20 system. Results: The relative alpha power and beta power showed no statistically significant differences between the two groups. But the relative gamma power of the CPz, C3, C4, P3, and P4 areas showed statistically significant differences between the two groups (p<0.05). The relative theta power of the C4 area showed statistically significant differences between the two groups (p<0.05). Conclusion: Our findings show that tibialis anterior muscle contraction by electrical stimulation and by voluntary repeated contraction differentially affected brain activation. In particular, the CPz, C3, C4, P3 positions of relative gamma power showed brain activation in voluntary contraction. The C4 position of relative theta power showed different brain activation between the two groups.

The Characteristics on the Change of Cerebral Cortex using Alternating Current Power Application for Transcranial Magnetic Stimulation

  • Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.197-204
    • /
    • 2014
  • A transcranial magnetic stimulation device is a complicated appliance that employs a switching power device designed for discharging and charging a capacitor to more than 1 kV. For a simple transcranial magnetic stimulation device, this study used commercial power and controlled the firing angle using a Triac power device. AC 220V 60 Hz, the power device was used directly on the tanscranial magnetic stimulation device. The power supply device does not require a current limiting resistance in the rectifying device, energy storage capacitor or discharge circuit. To control the output power of the tanscranial magnetic stimulation device, the pulse repetition rate was regulated at 60 Hz. The change trigger of the Triac gate could be varied from $45^{\circ}$ to $135^{\circ}$. The AVR 182 (Zero Cross Detector) Chip and AVR one chip microprocessor could control the gate signal of the Triac precisely. The stimulation frequency of 50 Hz could be implemented when the initial charging voltage Vi was 1,000 V. The amplitude, pulse duration, frequency stimulation, train duration and power consumption was 0.1-2.2T, $250{\sim}300{\mu}s$, 0.1-60 Hz, 1-100 Sec and < 1 kW, respectively. Based on the results of this study, TMS can be an effective method of treating dysfunction and improving function of brain cells in brain damage caused by ischemia.

Constrained Independent Component Analysis Based Extraction and Mapping of the Brain Alpha Activity in EEG

  • Ahn, S.H.;Rasheed, T.;Lee, W.H.;Kim, T.S.;Cho, M.H.;Lee, S.Y..
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.355-363
    • /
    • 2008
  • In order to extract only the alpha activity related signals from EEG recordings, we have applied Constrained Independent Component Analysis (cICA), a new extension of ICA in which some a priori knowledge of the alpha activity is utilized to extract only desired components. Its extraction (or filtering) performance has been compared to that of the conventional band-pass filtering via the scalp alpha power maps and cortical source maps of the alpha activity. Our results demonstrate that the alpha power maps and cortical source maps from the cICA-extracted alpha signals reveal more focalized alpha generating regions of the brain than those from the band-pass filtered alpha EEG signals. Furthermore they match more closely the activated regions of the brain mapped using fMRI, validating our results. We believe that the cICA-based filtering approach of EEG signals is a more effective means of extracting a specific brain activity reflected in EEG signals that will result in more accurate source localization or imaging maps.

EEG Based Brain-Computer Interface System Using Time-multiplexing and Bio-Feedback (Time-multiplexing과 바이오 피드백을 이용한 EEG기반 뇌-컴퓨터 인터페이스 시스템)

  • Bae, Il-Han;Ban, Sang-Woo;Lee, Min-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.236-243
    • /
    • 2004
  • In this paper, we proposed a brain-computer interface system using EEG signals. It can generate 4 direction command signal from EEG signals captured during imagination of subjects. Bandpass filter used for preprocessing to detect the brain signal, and the power spectrum at a specific frequency domain of the EEG signals for concentration status and non-concentration one is used for feature. In order to generate an adequate signal for controlling the 4 direction movement, we propose a new interface system implemented by using a support vector machine and a time-multiplexing method. Moreover, bio-feed back process and on-line adaptive pattern recognition mechanism are also considered in the proposed system. Computer experimental results show that the proposed method is effective to recognize the non-stational brain wave signal.

Fully Implantable Deep Brain Stimulation System with Wireless Power Transmission for Long-term Use in Rodent Models of Parkinson's Disease

  • Heo, Man Seung;Moon, Hyun Seok;Kim, Hee Chan;Park, Hyung Woo;Lim, Young Hoon;Paek, Sun Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.3
    • /
    • pp.152-158
    • /
    • 2015
  • Objective : The purpose of this study to develop new deep-brain stimulation system for long-term use in animals, in order to develop a variety of neural prostheses. Methods : Our system has two distinguished features, which are the fully implanted system having wearable wireless power transfer and ability to change the parameter of stimulus parameter. It is useful for obtaining a variety of data from a long-term experiment. Results : To validate our system, we performed pre-clinical test in Parkinson's disease-rat models for 4 weeks. Through the in vivo test, we observed the possibility of not only long-term implantation and stability, but also free movement of animals. We confirmed that the electrical stimulation neither caused any side effect nor damaged the electrodes. Conclusion : We proved possibility of our system to conduct the long-term pre-clinical test in variety of parameter, which is available for development of neural prostheses.

Culturing of Rat Intestinal Epithelial Cells-18 on Plasma Polymerized Ethylenediamine Films Deposited by Plasma Enhanced Chemical Vapor Deposition

  • Choi, Chang-Rok;Kim, Kyung-Seop;Kim, Hong-Ja;Park, Heon-Yong;Jung, Dong-Geun;Boo, Jin-Hyo
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1357-1359
    • /
    • 2009
  • Many researchers studied cell culturing on surfaces with chemical functional groups. Previously, we reported surface properties of plasma polymerized ethylenediamine (PPEDA) films deposited by plasma enhanced chemical vapor deposition with various plasma conditions. Surface properties of PPEDA films can be controlled by plasma power during deposition. In this work, to analyze correlation of cell adherence/proliferation with surface property, we cultured rat intestinal epithelial cells-18 on the PPEDA films deposited with various plasma powers. It was shown that as plasma power was decreased, density of cells cultured on the PPEDA film surface was increased. Our findings indicate that plasma power changed the amine density of the PPEDA film surface, resulting in density change of cells cultured on the PPEDA film surface.

Effects of Silkworm(Bombyx mori L.) Power on Oxidative Stress and Membrane Fluidity in Brain of SD Rats (뇌조직의 산화적 스트레스 및 세포막 유동성에 미치는 누에분말의 영향)

  • 최진호;김대익;박수현;김정민;조원기;이희삼;류강선
    • Journal of Life Science
    • /
    • v.11 no.2
    • /
    • pp.103-110
    • /
    • 2001
  • This study was designed to investigate the effects of silkworm(Bombyx moril L.) powder on oxidative stress and membrane fluidity in brain membranes of rats. Sprague-Dawley(SD) male rats(160$\pm$10 g) were fed basic diet(control group), and experimental diets(SWP-200 and SWP-400 groups) added 200 and 400mg/kg BW/day for 6 weeks. There were no significant differences in cholesterol levels of brain memberanes by administration of silkworm powder (SWP). Membrane fluidities were significantly increased(21.5% and 30.8%, respectively) in brain mitochondria of SWP-200 and SWP-400 groups compared with control group, but significant difference between brain microsomes could not obtained. Basal oxygen radicals (BORs) in brain mitochondria and mircrosomes were significantly inhibited(8.5% and 16.5%, 16.8%and 24.8%, respectively) by SWP-200 and SEP-400 groups compared with control group. Induced oxygen radicals(IORs) in brain mitochondria were significantly inhibited(16.6% and 21.4%, respectively)by sWP-200 and SWP-400 groups compared with control group, but IOR in brain microsome were significantly inhibited about 16.0% by SWP-400 groups only compared with control group. Lipid peroxide(LPO) levels were significantly decreaed(14.8%and 22.4%, respectively) in brain mitochondria of SWP-200 and SWP-400 groups compared with control group, but LPO level was significantly decreased about 16.0% in brain microsome of SWP-400 group only. Oxidized protein(OP) levels were remarkably decreased(about 14.8% and 16.5%, respectively) in brain mitochondria of SWP-200 and SWP-400 groups, but OP level was significantly decreased about 13.0% in brain microsome of SWP-400 group only compared with control group, Theses results suggest that administration of in brain microsome of SWP-400 group only compared with control group. These results suggest that administration of SWP may play effective role in attenuating an oxidative stress and increasing a membrane fluidity in brain membranes.

  • PDF

Arduino-based power control system implemented by the MyndPlay (MyndPlay를 이용한 Arduino기반의 전원제어시스템 구현)

  • Kim, Byeongsu;Kim, Seungjin;Kim, Taehyung;Baek, Dongin;Shin, Jaehwan;An, Jeong-Eun;Jeong, Deok-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.924-926
    • /
    • 2015
  • In this paper, we use the interface, which many countries concentrates research of Brain - Computer Interface with the device and MyndPlay based on the IoT intelligent Arduino. Finally we will make the Brain - Computer Connection environment, the purpose of Brain - Computer Interface. Recognizes the EEG of a person who wearing the equipment, analyze, classify, and we did a research to design an intelligent thing to suit user's condition. In addition, we use the XBee, and Bluetooth to communicate to other devices, such as smart phone. In conclusion, this paper check users current status via brain waves, and it allows to control the power and other objects by using the EEG(Electroencephalography).

  • PDF