• Title/Summary/Keyword: the Unit

Search Result 29,249, Processing Time 0.051 seconds

Cost Analysis Model with Minimal Repair of Spare Unit Repair Policy under Periodic Maintenance Policy (정기보전 제도에서 응급수리를 고려한 대체품 수리정책에서의 비용분석 모델)

  • Kim Jae-Joong
    • Journal of Applied Reliability
    • /
    • v.6 no.2
    • /
    • pp.151-161
    • /
    • 2006
  • This article is concerned with cost analysis model in periodic maintenance policy. The repair policy is differently applied according as unit importance during an item being used and unit restoration during an item being failed. So in this paper the repair policy with minimal repair is considered as follow : as the occurrence of failure between minimal repair and periodic interval time, unit is replaced by a spare unit until the periodic maintenance time arrived. Then total expected cost per unit time is calculated according to scale parameter of failure distribution in a view of customer's. The total expected costs are included repair and usage cost : operating, fixed, minimal repair, periodic maintenance and spare unit cost. Numerical example is shown in which failure time of item has Erlang distribution.

  • PDF

AIMS-MUPSA software package for multi-unit PSA

  • Han, Sang Hoon;Oh, Kyemin;Lim, Ho-Gon;Yang, Joon-Eon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1255-1265
    • /
    • 2018
  • The need for a PSA (Probabilistic Safety Assessment) for a multi-unit at a site is growing after the Fukushima accident. Many countries have been studying issues regarding a multi-unit PSA. One of these issues is the problem of many combinations of accident sequences in a multi-unit PSA. This paper deals with the methodology and software to quantify a PSA scenarios for a multi-unit site. Two approaches are developed to quantify a multi-unit PSA. One is to use a minimal cut set approach, and the other is to use a Monte Carlo approach.

Novel Driving Scheme to remove residual image sticking in AMOLED

  • Parikh, Kunjal;Choi, Joon-Hoo;Cho, Kyu-Sik;Huh, Jong-Moo;Park, Kyong-Tae;Jeong, Byoung-Seong;Park, Yong-Hwan;Kim, Tae-Youn;Lee, Baek-Woon;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.553-556
    • /
    • 2008
  • We hereby report novel driving scheme to eliminate effect of "residual" image sticking (RRI) problem which arises due to hysteresis problem in Thin Film Transistor (TFT) in AMOLED Displays. The driving scheme applies "black" voltage after every data voltage period in order to drive AMOLED in uni-direction. The system can be easily implemented with 120 Hz driving scheme which is well matured in AMLCD industries. Our analyses show systematic evaluation of the problem and thereby solving it by simple methods which will be significantly effective of driving OLED towards mass manufacturing stage.

  • PDF

A study on the derivation of Dimensionless Unit Hydrographs by the Linear model in the small watersheds (선형 Model에 의한 소류역에 있어서의 무차원 단위도 유도에 관한 연구)

  • 이순혁;한중석
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.23 no.3
    • /
    • pp.78-87
    • /
    • 1981
  • This study was attempted to get dimensionless unit hydrograph by linear model which can be used to the estimation of flood for the development of Agricultural water resources and laid emphasis on the application of dimensionless unit hydrographs for the ungaged watersheds by applying linear model. The results summarized through this study are as follows. 1.Peak discharge is found to be Qp= CAR (C =0. 895A-o.145) having high significance between peak discharge, Qp and effective rainfall, R within the range of small watershed area, 84 to 470km2. consequently, linearity was acknowledged between rainfall and runoff. Reasonability is confirmed for the derivation of dimensionless unit hydrograph by linear model. 2.Through mathematical analysis, formula for the derivation of dimensionless unit hydrograph was derived. qp--p=(tp--t)n-1[e-(n-1)](tp--t-1) 3.Moment method was used for the evaluation of storage constant, K and shape parameter, n for the derivation of dimensionless unit hydrograph. Storage constant, K is more closely related with the such watershed characteristics as length of main stream and slopes. On the other hand, the shape parameter, n was derived with such watershed characteristics as watershed area, river length, centroid distance of the basin and slopes. 4.Time to peak discharge, Tp could be expressed as Tp=1. 25 (√s/L)0.76 having a high significance. 5.Dimensionless unit hydrographs by linear model stood more closely to the observe dimensionless unit hydrographs On the contrary, dimensionless unit hydrographs by S.C. S. method has much difference in comparison with linear model at the falling limb of hydrographs. 6.Relative errors in the q/qp at the point of 0.8 and 1.2 for the dimensionles ratio by linear model and S. C. S. method showed to be 2.41, 1.57 and 4.0, 3.19 percent respectively to the q/qp of observed dimensionless unit hydrographs. 7.Derivation of dimensionless unit hydrograph by linear model can be accomplished by linking the two empirical formulars for storage constant, K, and shape parameter, n with derivation formular for dimensionless unit hydrograph for the ungaged small watersheds.

  • PDF

Characteristics Analysis on the Unit Plans of Apartment Houses in Jeon-ju City - Spacial tendency was focused on the unit size of $69.42-115.70m^2$ - (전주시 아파트 주거의 평면적 특성 분석 - 21-35평형을 중심으로 변화 추이 -)

  • Choi Byung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.102-110
    • /
    • 2006
  • The purpose of this study was to find out the spacial characteristics from the $69.42-11.70m^2$ unit plans of the apartment houses in Jeon-ju city, and to check up on the general spacial principles of Korean apartment unit plans. The content analysis method and the survey method were used for this study. The data of apartment unit plans and the questionnaires were collected from apartment offices or real estate agency offices. The data of 157 unit plans and 190 questionnaires were analyzed. The results of this study were as follows; 1) The general spacial principles of Korean apartment unit plans, the tendency of front 3-bay unit plan, the openness of living room, the Anbang with a bathroom and a dressroom, the utility room as a kitchen support space, and the addition of balconies, were showed in those of Jeon-ju city. 2) There was a new tendency, the front room arrangement of Anbang-living room-bedroom was changed into Anbang-living room-bathroom or kitchen, in them. 3) The characteristics of L-DK floor plans that the closeness of DK from exterior space and the interior openness and exterior privacy of L were showed in them. 4) The entrance was needed a intermediate space as a balcony or a former space, in them. These tendencies on unit plans of the apartment houses in Jeon-ju city were followed the general spacial principles of Korean apartment unit plans.

The Case Study on The Introduction and Practical Application of the Budget Management System -On the Performance Measurement of Standard Work Unit- (예산관리제도의 도입과 실제적 운용에 관한 사례연구 -표준적인 작업의 성과측정을 중심으로-)

  • 윤용운
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.39-51
    • /
    • 1979
  • In introducing and applying the budget management system, the question of how to establish management structure(skelton) representing budget management responsible unit is significantly related to the degree of accuracy and analysis on the performance measurement of standard work unit. We have the following rational process of establishing performance measurement of budget management System ; 1) Standardization of work method 2) Establishment of management structure 3) Institution of budget management system. Especially, this system is based on a premise of efficiency of objectives management, it is assumed that performance measurement in the standard work unit must be enforced according to the basis and categories of performance evaluation based on the evaluating work unit. Therefore, most of all, the following three detail questions(subjects) are to be determined in order to rationalize these above principles to a maximum possible extent of performance measurement system. First, we established respective performance standard unit with respect to such detailed work unit, performance standard unit of which were accurately applicable directly from using the budget ana objectives account data and their supplementary data of the work measurement techniques. Second, by using the above mentioned question, over all evaluation and suggestion are made based on the study of the recording for each work unit development, budget management and production nit (volume of production) Third, the measurement of performance of budget management system is based on the principle of standard work unit, compared with the standard basis and actual work unit by period and activities unit and calculated percentage effectiveness according to the above procedure. and so evaluated the efficiency of performance measurement on the budget management system.

  • PDF

The Development of Hemodialysis System Based on Embedded System (임베디드 시스템 기반의 혈액 투석기 시스템의 개발)

  • Ji, Jung-Ho;Lee, Kyoung-Joung;Kim, Young-Ho;Park, Kwang-Li
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.11
    • /
    • pp.521-527
    • /
    • 2002
  • The Hemodialysis system is the device for the patients who have suffered from end stage renal failure as the kidney which removes the waste products in a human body. The existing hemodialysis is based on a 8-bit micro-controller and it is not a touch-screen type but a manual type. This paper is focused on hemodialysis system based on high control and expension embedded system. The whole system consists of main control unit and sub control unit(dialysis control unit, blood control unit, monitoring control unit, networking unit). The dialysis control unit, blood control unit, monitoring control unit are processed by 3 microcontrollers and network unit is for monitoring a renal failure patient's condition. For the evaluation of the system performance, the saline was pured into blood unit and then water removal rate, conductivity and temperature of hemodialysis liquid were measured 10 times in an each state suing the UF pump in the fluid unit varing the quantity of saline to 1000cc, 2000cc, 3000cc and 4000cc. As a result, the rates of water removal are 98.6% in condition of 000cc saline, 96.9% in 2000cc, 98.9% in 3000cc and 98.3% in 4000cc. The conductivities of hemodialysis liquid are 99.6% in the first to third condition and 99.7% in the forth condition. The temperatures of hemodialysis liquid are 99.8% in the first to third condition and 99.6% in th forth condition.

A Unit Touch Gesture Model of Performance Time Prediction for Mobile Devices

  • Kim, Damee;Myung, Rohae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.277-291
    • /
    • 2016
  • Objective: The aim of this study is to propose a unit touch gesture model, which would be useful to predict the performance time on mobile devices. Background: When estimating usability based on Model-based Evaluation (MBE) in interfaces, the GOMS model measured 'operators' to predict the execution time in the desktop environment. Therefore, this study used the concept of operator in GOMS for touch gestures. Since the touch gestures are comprised of possible unit touch gestures, these unit touch gestures can predict to performance time with unit touch gestures on mobile devices. Method: In order to extract unit touch gestures, manual movements of subjects were recorded in the 120 fps with pixel coordinates. Touch gestures are classified with 'out of range', 'registration', 'continuation' and 'termination' of gesture. Results: As a results, six unit touch gestures were extracted, which are hold down (H), Release (R), Slip (S), Curved-stroke (Cs), Path-stroke (Ps) and Out of range (Or). The movement time predicted by the unit touch gesture model is not significantly different from the participants' execution time. The measured six unit touch gestures can predict movement time of undefined touch gestures like user-defined gestures. Conclusion: In conclusion, touch gestures could be subdivided into six unit touch gestures. Six unit touch gestures can explain almost all the current touch gestures including user-defined gestures. So, this model provided in this study has a high predictive power. The model presented in the study could be utilized to predict the performance time of touch gestures. Application: The unit touch gestures could be simply added up to predict the performance time without measuring the performance time of a new gesture.

Effort Analysis of Unit Testing Conducted by Non-Developer of Source Code (원개발자 부재에 따른 원시코드 기반의 단위테스트 노력 분석)

  • Yoon, Hoijin
    • Journal of Information Technology Services
    • /
    • v.11 no.4
    • /
    • pp.251-262
    • /
    • 2012
  • Unit testing is one of the test levels, which tests an individual unit or a group of related units. Recently, in Agile Development or Safety-critical System Development, the unit testing plays an important role for the qualities. According to the definition of unit testing, it is supposed to be done by the developers of units. That is because test models for the unit testing refers to the structure of units, and others but its original developers hardly can understand the structures. However, in practice, unit testing is often asked to be done without the original developers. For example, it is when faults are revealed in customer sites and the development team does not exit any more. In this case, instead of original developers, other developers or test engineers take a product and test it. The unit testing done by a non-developer, who is not the original developer, would cause some difficulties or cause more cost. In this paper, we tests an open source, JTopas, as a non-developer, with building test models, implementing test codes, and executing test cases. To fit this experiment to practical testing situations, we designed it based on the practices of unit testing, which were surveyed through SPIN(Software Process Improvement Network). This paper analyzes which part of unit testing done by non-developers needs more effort compared to the unit testing done by original developers. And it concludes that Agile Development contributes on reducing the extra effort caused by non-developers, since it implements test codes first before developing source code. That means all the units have already included their own tests code when they are released.