• Title/Summary/Keyword: thawing methods

Search Result 244, Processing Time 0.024 seconds

Effect of Cryopreservation Day on Pregnancy Outcomes in Frozen-thawed Blastocyst Transfer (동결 해동한 포배 이식에 있어서 동결시기가 임신결과에 미치는 영향)

  • Kim, Hyun-Jung;Kim, Chung-Hyon;Lee, Joong-Yeup;Kwon, Jae-Hee;Hwang, Do-Yeong;Kim, Ki-Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • Objectives: Likewise fresh cycle, it is also important to select right blastocysts for transfer in purpose of improving the pregnancy and implantation rates in frozen-thawed embryo transfer (ET) cycles. To investigate the relationship between the developmental velocity at the time of cryopreservation and pregnancy rates, we compared pregnancy rates between the day 5 cryopreservation group and the day 6 cryopreservation group. Methods: Transfers of frozen-thawed blastocysts which had been cryopreserved by vitrification on day 5 or day 6 were performed between January 2006 and June 2007. Ethylene glycol, DMSO, and pull and cut straws were used for vitrification and artificial shrinkage was done in expanded blastocysts. Thawing was performed on the day before transfer and thawed blastocysts were cultured in for 15~18 hrs in Quinn's blastocyct media. Blastocyst survival was assessed before transfer and post-thaw survival was defined as >50% of cells remaining intact and blastocoele re-expansion by the time of transfer. Results: Transfers of thawed blastocyst had been cryopreserved on day 5 were 52 cycles and 41 transfer cycles were cryopreserved on day 6. Patient characteristics, the number of transferred embryos and the survival rate of thawed blastocysts were not different in each cryopreservation day. But the biochemical pregnancy, clinical pregnancy, ongoing pregnancy, and implantation rate were significantly high in transfer of frozen-thawed blastocyst which were cryopreserved on day 5. Conclusions: The clinical pregnancy and implantation rate of day-5 blastocyst showed significantly higher than those of day-6 blastocyst in frozen-ET cycles. This result indicated that developmental rate of blastocyst at cryopreservation time in frozen-thawed cycle is discriminative marker of pregnancy outcome as like in fresh cycle.

Factors Required to Sustain Pastoral Farming Systems and Forage Supply In Winter-Cold Zones in Canada (캐나다의 동계한냉지역에 있어서 초지개발과 조사료 공급의 활성화에 필요한 요인)

  • Kunelius, H.T.;Fraser, Joanna
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.12 no.3
    • /
    • pp.3-12
    • /
    • 1992
  • Forage grasses and legumes ar$\varepsilon$ the mam component of livestock diets in Canada. There are over 30 million ha of grassland in Canada and there is a large, undeveloped land base in fringe areas suitable for forage production. The short growing s season limits the grassland farming to the southern p parts of Canada. The win!er season is long and in most parts of Canada cold temperatures, fr$\varepsilon$ezmg, and thawing, and diseases exert sever$\varepsilon$ stress on overwintering forage plants. The development of persistent cultivars is essential for sustained production particularly in the fringe areas with short growmg s$\varepsilon$ason. The seasonality of dry matter production is a result of high growth rates in early summ$\varepsilon$r and low dry matter accumulation in late summer and fall. Innovative management practIces a and cultivars with improved regrowth capacity are n necessary to overcome such skewed production pattern and to extend effiectlVe grazmg season l Improved pasture production is an important part of reducing costs in livestock operations and remaining competitive. It is suggested that applying available technology would increase pasture productivity and reduce d$\varepsilon$pendence on stored feeds thus improving profitability of small producers in particeular. Reducing nutrient losses during harv$\varepsilon$stmg, s storage, and feeding is essential for improved production efficiency during confinement. The devclopment of low cost and labor saving methods of ensiling is critical for improved efficiency and profitability of forage based enterprises Livestock industries must respond to consumer preferences for low fat and cholesterol foods. Research and development of entire production systems is emphasized for dev$\varepsilon$loping viabl$\varepsilon$ enterprises. It is increasingly difficult to secure resources for r$\varepsilon$search, education, and extension, and alliane$\varepsilon$s and cooperation must expand among organizations with interests in forage based livestock systems.

  • PDF

EVALUATION OF THE VIABILITY OF PERIODONTAL LIGAMENT CELL IN RAT TEETH USING SLOW CRYOPRESERVATION METHOD WITH MAGNETIC FIELD (자기장 저속 냉동보관법을 이용한 쥐 치아 치주인대세포의 활성도 검사)

  • Ahn, Hyun-Jung;Kim, Eui-Seong;Kim, Jin;Kim, Duck-Won;Kim, Ki-Yeol;Lee, Chan-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.332-340
    • /
    • 2008
  • The purpose of this study was to evaluate the viability of periodontal ligament cell in rat teeth using slow cryopreservation method with magnetic field through MTT assay and TUNEL test. For each group, 12 teeth of 4 weeks old white female Sprague-Dawley rat were used for MTT assay, and 6 teeth in TUNEL test. The Maxillary left and right, first and second molars were extracted as atraumatically as possible under tiletamine anesthesia. The experimental groups were group1 (immediately extraction), group 2 (cold preservation at 4$^{\circ}C$ for 1 week), group 3 (rapid cryopreservation in liquid nitrogen), group 4 (slow cryopreservation with magnetic field of 1 G), and group 5 (slow cryopreservation). F medium was used as preservation medium and 10% DMSO as cryoprotectant. After preservation and thawing, the MTT assay and TUNEL test were processed. One way ANOVA and Scheffe method were performed at the 95% level of confidence. The value of optical density obtained after MTT analysis was divided by the value of eosin staining for tissue volume standardization. In both MTT assay and TUNEL test, it had showed no significant difference among group 3, 4, and 5. And group 3 had showed higher viability of periodontal ligament cell than group 2. From this study, slow cryopreservation method with magnetic field can be used as one of cryopreservation methods.

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF