• Title/Summary/Keyword: testing data

Search Result 4,735, Processing Time 0.034 seconds

Morphological Characteristics and Classification Criteria for Azalea Cultivars for Landscaping in Korea (조경용 철쭉재배품종의 형태적 특성 및 분류기준)

  • Choi, Jae-Jin;Park, Seok-Gon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.2
    • /
    • pp.77-85
    • /
    • 2014
  • This study was conducted to examine the morphological characteristics of those Azalea Cultivars(hereinafter, Azalea Cultivars) that are mainly used for landscaping in Korea in order to prepare classification criteria. As testing materials, major Azalea Cultivars cultivated in large quantities by its producing companies were collected. Thereafter, the qualitative and quantitative characteristics of the traits of Azalea Cultivars were investigated in the way of characteristic investigation for new cultivars of azalea used by the Korea Seed and Variety Service in order to classify them and prepare the classification criteria. Since cultivar names have not been established for Azalea Cultivars for landscaping thus far, the data were compiled using the names used by cultivating companies. According to the results, Azalea Cultivars cultivated in Suncheon, Jeonnam mainly for landscaping were 10 in number; Beni, Daewang, Three, Zasanhong, Hancheol, Sancheoljuk, Gyeobsancheoljuk, Baekcheoljuk, Akado, and Seok-am. Among them, the cultivars Beni, Daewang, and Three could not be easily distinguished from each other because they are commonly called Yeongsanhong by cultivating companies and the shapes of their leaves and flowers are similar to each other. In particular, the flower color of Beni was 'bright red', that of Daewang was 'vivid purple', and that of Three was 'bright purple'. In addition, Zasanhong and Hancheol were similar to each other in shape the degree of expression of spots on the flowers and the gloss on the front side of the leaves of Hancheol were higher and stronger compared to that of Zasanhong. Sancheoljuk flowered in early April, earlier compared to other Azalea Cultivars. Gyeobsancheoljuk is an elementary species of Sancheoljuk and it had double flowers although all other traits were similar to those of Sancheoljuk. Although Baekcheoljuk was easily distinguished because it had white flowers, its leaves were similar to those of Akado the reason why these two cultivars could not be easily distinguished from each other. The cultivar Akado flowered early May later compared to other Azalea Cultivars and its flowers were relatively large in diameter as with Baekcheoljuk and Sancheoljuk. Finally, the cultivar Seok-am was easily distinguished because it had smaller leaves compared to other cultivars and it flowered late as with the cultivar Akado.

A Study on the Factors Affecting the Success of Technology Marketing (기술마케팅 성공에 영향을 미치는 요인에 관한 분석)

  • Hwang, Nam-Gu;Oh, Young-Ho;Kim, Kyoung-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2358-2370
    • /
    • 2010
  • This research aims to empirically analyze the factors that affect the success of technology marketing by Korean universities. The total of 207 universities which successfully made technology transfers from 2006 to 2008 was examined to test the nine hypotheses. For the purpose of testing the hypotheses, technology infrastructure (research costs and the number of SCIE papers), the compensation system for the patents (application and registration), the number of patents (application and registration), TLO staff (the number of people in charge of technology transfer and the job experience in industries), the compensation system for technology transfers (researchers and contributors), and attitudes of university management and industries were analyzed with structural equation methods to figure out their effects on the revenues of technology transfer. The results of this research are summarized as follows. First, technology infrastructures of universities were found to have positive effects on securing patents. As the university research costs in the field of science and technology are increases, the research capabilities are enhanced and this a larger number of researchers are conducted. Second, this research shows that compensation systems for patent application and registration in universities have motivated researchers to take out patents for the outputs of their research. Third, the number of patents universities possess was found to have a positive effect on technology transfer. An increase in the number of patents universities possess implies an increase in the diversity and excellence of the target technologies for transfer. Fourth, the number of patents universities possess turned out to have a positive effect on TLO staff. The number of experts in charge of technology transfer including technology dealers, valuation analysis and patent attorneys should be increased as target technologies for transfer increase according to the increase of patents possessed. Because the technologies are transferee from universities to businesses, businesses (job) experience of TLO staff in industries are also important. This research is meaningful because it has identified the factors affecting the results of technology transfer by employing structural equation methods. In particular, an official governmental survey data for the academic-industrial cooperation were analyzed systematically in terms of technology infrastructure, compensation systems related to patents, the number of patents, TLO staff, compensation systems for technology transfer, and attitudes of university management and industries. All these facts might could differentiate this study from the previous studies.

Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin (광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구)

  • Choi, Yong-Hoon;Bae, Ji-Hyun;Son, Ho-Hyun;Lee, In-Bog;Um, Chung-Moon;Baek, Seung-Ho;Kim, Oh-Young;Kim, Chang-Keun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives : This study investigated the hypothesis that increasing light-curing time would leave the oxygen-inhibited layer (OIL) of the adhesive thinner, and in turn, result in lower shear bond strength (SBS) than those obtained by the routine curing procedures. Methods:120 human extracted posterior teeth were randomly divided into three groups for bonding with three adhesives:All Bond 2/sup (R)/, One Step/sup (R)/, and Adper Prompt/sup (R)/. They were subsequently divided into four subgourps with different light-curing time (10, 20, 30 and 60s). The assigned adhesives were applied on superficial occlusal dentin according to the manufacturer's instructions and cured with one of the four curing times. Composite resin cylinder, 2.35㎜ in diameter, were built on the cured adhesive and light-cured for 40s. SBS were measured after 24h from the bonding using a universal testing machine (crosshead speed 1.0 ㎜/min). The relative thickness of the OIL and the degree of conversion (DC) were determined from the adhesive on a slide glass using FT-NIR in an absorbance mode. Data were analysed with One-way ANOVA and Duncan's multiple test (p〈0.05), Results:With increasing cure time, although there were no significant difference in th SBS of One-step and Adper Prompt (p〉0.05), those of All Bond 2 decreased significantly (p〈0.05). The relative thicknesses of the OIL on each adhesive were not affected by the cure time (p〉0.05). Although the DC of All-Bond 2 were statistically not different with increasing cure time (p〉0.05), those of One-Step and Adper Prompt showed an increasing trends with increasing cure time (p〈0.05). Conclusions:Increasing light-curing time did not affect on the relative thickness of the OIL of the adhesives, and in turn, on the SBS to dentin.

THE BONDING DURABILITY OF RESIN CEMENTS (레진시멘트의 접착 내구성에 관한 연구)

  • Cho, Min-Woo;Park, Sang-Hyuk;Kim, Jong-Ryul;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.343-355
    • /
    • 2007
  • The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ($12\;{\times}\;12\;{\times}\;6\;mm^3$). It's surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted witk $20\;-\;50\;{\mu}m$ alumina oxide. According to each manufacturer's instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at $37^{\circ}C$ for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using all Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to $1.0\;{\times}\;1.0\;mm^2$ composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm/min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan's multiple comparison test at $p\;{\leq}\;0.05$ level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). 4. Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement.

Development and Application of the High Speed Weigh-in-motion for Overweight Enforcement (고속축하중측정시스템 개발과 과적단속시스템 적용방안 연구)

  • Kwon, Soon-Min;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.69-78
    • /
    • 2009
  • Korea has achieved significant economic growth with building the Gyeongbu Expressway. As the number of new road construction projects has decreased, it becomes more important to maintain optimal status of the current road networks. One of the best ways to accomplish it is weight enforcement as active control measure of traffic load. This study is to develop High-speed Weigh-in-motion System in order to enhance efficiency of weight enforcement, and to analyze patterns of overloaded trucks on highways through the system. Furthermore, it is to review possibilities of developing overweight control system with application of the HS-WIM system. The HS-WIM system developed by this study consists of two sets of an axle load sensor, a loop sensor and a wandering sensor on each lane. A wandering sensor detects whether a travelling vehicle is off the lane or not with the function of checking the location of tire imprint. The sensor of the WIM system has better function of classifying types of vehicles than other existing systems by detecting wheel distance and tire type such as single or dual tire. As a result, its measurement errors regarding 12 types of vehicle classification are very low, which is an advantage of the sensor. The verification tests of the system under all conditions showed that the mean measurement errors of axle weight and gross axle weight were within 15 percent and 7 percent respectively. According to the WIM rate standard of the COST-323, the WIM system of this study is ranked at B(10). It means the system is appropriate for the purpose of design, maintenance and valuation of road infrastructure. The WIM system in testing a 5-axle cargo truck, the most frequently overloaded vehicle among 12 types of vehicles, is ranked at A(5) which means the system is available to control overloaded vehicles. In this case, the measurement errors of axle load and gross axle load were within 8 percent and 5 percent respectively. Weight analysis of all types of vehicles on highways showed that the most frequently overloaded vehicles were type 5, 6, 7 and 12 among 12 vehicle types. As a result, it is necessary to use more effective overweight enforcement system for vehicles which are seriously overloaded due to their lift axles. Traffic volume data depending upon vehicle types is basic information for road design and construction, maintenance, analysis of traffic flow, road policies as well as research.

  • PDF

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.

A Seroepidemiologic Study of Hepatitis A Virus in the Healthy Children and Adolescent in Kyonggi-do Province (경기도 지역의 건강한 소아와 청소년에서 A형 간염 바이러스의 항체 보유율에 대한 역학 조사)

  • Roh, Hye Ok;Sohn, Young Mo;Park, Min Soo;Choi, Boyoul;Bang, Keum Nie;Ki, Moran;Kim, Ji Hee
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.232-239
    • /
    • 1997
  • Purpose: The incidence of hepatitis A virus(HAV) infection has markedly decreased in the last 20 years due to industrialization and improvements in the standard of living and hygiene in Korea. The reduction in seroprevalence rates indicates infection potential for young adult population, and a need for vaccinations in high-risk adults and children groups has been suggested. In this study we evaluated the seroprevalence rates and natural infection rates of hepatitis A in children and adolescent to obtain the basic data for vaccination of hepatitis A. Methods: A total of 334 children and adolescent subjects below 20 years old in Kyonggi-do province were examined for HAV antibody and seroprevalence rates in each age group was investigated. In 584 elementary school students residing in Kyonggi-do province, serum samples collected in 1993 and 1996 from the same subjects for investigation of natural seroconversion rates. Method of testing antibody was enzyme immunoassay. Results: 1) The seropositive rate of HAV in 334 subjects aged below 20 years old was 5.4%. According to age, the seropositive rates were 27.3% in infant group, 0.0% in 1~4 year-old group, 0.0% in 5~9 year-old group, 2.9% in 10~14 year-old group and 15.0% in 15~19 year-old group. 2) In the study of 584 elementary school children, only one subject showed seropositive in 1993, and in 1996 three different subjects showed seropositive results(0.5%); the natural seroconversion rate during 3 years was 0.5%. 3) The seroprevalence rates of below 20 year-old subjects reported in previous studies were 63.8% in 1979 and 47.3% in 1989 while the present study showed the rate at 5.4%. Conclusion: Since natural antibody formation is rarely occurring, there is a high risk for apparent hepatitis A infection in adults. Therefore vaccination in high risk groups is essential at present, and in order to reduce the chance for hepatitis A infection in adults, vaccination in children may be needed.

  • PDF

A Comparative Study of the Handicaps in and Satisfaction with the Ordinary Life before and after the Plastic Operation for Artificial Joint Replacement-Centering around Those Who suffer from Joint Diseases (인공관절 전치환 성형 수술 전후의 일상활동 장애정도 및 삶의 만족도 비교연구 - 관절 질환 환자를 중심으로 -)

  • Kang, Shin-Hwa
    • Journal of muscle and joint health
    • /
    • v.3 no.1
    • /
    • pp.37-49
    • /
    • 1996
  • The joint diseases threaten modern people's healthy life. They bring about a long pain, an anasarca, loss of joint function or even deformation and rigidity of joint, limiting people's ordinary activities much. The chronic joint patients may be subject to some hypochondria caused by anxiety for their life, social isolation, financial problem and physical disability. Therefore, this population should continue to be duely taken care of by medical personnels. In particular, nurses should adequately help these people to recover and improve their health through suitable adaptations. With such basic conceptions in mind, this study was aimed at reviewing these patients' conditions in their ordinary life before and after a plastic operation for artificial joint replacement as well as their satisfaction with their life. For this purpose, those patients who underwent some plastic operations for artificial joint replacement at university hospitals in Seoul from January 2, 1993 to June 30, 1995 were selected as the population of this study. Among them, 87 people were randomly sampled to answer a questionnaire designed specially. For the surveying tools, Jette's (1980) scale was applied to address the sample people's inconveniences experienced and supports received in their ordinary life, while the scale of Wood, Wylie & Sheafer was used to measure their satisfaction with their life. The collected data were analyzed for percentiles, means, SD, t-test and Pearson's correlations. The results of survey can be summarized as follows ; As a result of t-test the frequencies of other people's support before and after the plastic operation, it was disclosed that those who underwent the operation were supported less frequently. In addition, as a result of t-testing their satisfaction with life before and after the operation, it was found that the operation increased their satisfaction with life significantly. Meanwhile, as a result of t-test inconveniences, frequencies of supports and life satisfaction before and after the plastic operation for artificial knee replacement, it was disclosed that only the inconveniences were significantly reduced after the operation. In contrast, the t-test the variables before and after the plastic operation for artificial hip replacement, it was found that only the frequencies of other people's supports were significant reduced after the operation. Furthermore, the differences 6 months, one year and two years after the plastic operation for artificial joint replacement were t-tested on the variables. As a result, it was disclosed that people's inconvenience, frequencies of supports and life satisfaction were not improved 6 months after the operation but their frequencies of supports decreased significantly one year after, while their inconveniences and life satisfaction were significantly improved two years after. As a result of analyzing the variables with Pearson's correlations, inconveniences and frequency of supports were negatively correlated significantly with the life satisfaction. In conclusion, the plastic operation for artificial joint replacement significantly improved people's living inconveniences, reduced their frequency of other people's support and enhanced their satisfaction with life. To break don the plastic operation for artificial knee replacement improved patients' inconveniences, while the plastic operation for artificial hip replacement not only improved patients' inconveniences but reduced the frequencies of other people's support also. Finally, the finding that the plastic operation for artificial joint replacement brought about the improvement two years after suggests that this period is needed for the patients to adapt themselves to the post-operation conditions.

  • PDF

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

The Influence of AH-26 and Zinc Oxide-Eugenol Root Canal Sealer on the Shear Bond Strength of Composite Resin to Dentin (AH-26 및 산화아연유지놀 근관실러가 상아질에 대한 복합레진의 전단결합강도에 미치는 영향)

  • Cho, Ju-Yeon;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.147-152
    • /
    • 2006
  • The purpose of this study was to evaluate the influence of the AH-26 root canal sealer on the shear bond strength of composite resin to dentin. One hundred and forty four (144) extracted, sound human molars were used. After embedding in a cylindrical mold, the occlusal part of the anatomical crown was cut away and trimmed in order to create a flat dentin surface. The teeth were randomly divided into three groups; the AH-26 sealer was applied to the AH-26 group, and zinc-oxide eugenol (ZOE) paste was applied to the ZOE group. The dentin surface of the control group did not receive any sealer. A mount jig was placed against the surface of the teeth and the One-step dentin bonding agent was applied after acid etching. Charisma composite resin was packed into the mold and light cured. After polymerization, the alignment tube and mold were removed and the specimens were placed in distilled water at $37^{\circ}C$ for twenty four hours. The shear bond strength was measured by an Instron testing machine. The data for each group were subjected to one-way ANOVA and Tukey's studentized rank test so as to make comparisons between the groups. The AH-26 group and the control group showed significantly higher shear bond strength than the ZOE group (p<0.05). There were no significant differences between the AH-26 group and the control one (p>0.05). Under the conditions of this study, the AH-26 root canal sealer did not seem to affect the shear bond strength of the composite resin to dentin while the ZOE sealer did. Therefore, there may be no decrease in bond strength when the composite resin core is built up immediately after a canal filling with AH-26 as a root canal sealer.