• Title/Summary/Keyword: test valve

Search Result 804, Processing Time 0.019 seconds

Anatomical Structures of the Aortic Root in Koreans (한국인 대동맥 근부의 해부학적 구조)

  • Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Kim, Si-Wook;Kim, Su-Il;Chung, In-Hyuk;Na, Myung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.321-328
    • /
    • 2007
  • Background: It is very important to determine the surgical anatomy of the aortic root when performing spreading aortic root preserving heart surgery. This study focuses on the surgical aspect of the aortic root anatomy by performing dissection of Korean cadavers. Material and Method: The subjects were 62 cadavers. We measured the intercommissural distances, heights of the sinuses and the circumference of the sinotubular junction and the aortic annulus. Result: The mean age of death was 61.3 years. The intercommissural distance for the right coronary sinus was $0.73{\pm}2.23mm$, that for the non coronary sinus was $19.34{\pm}2.03mm$, and that for the left coronary sinus was $18.58{\pm}2.15mm$. The height of sinus was $20.59{\pm}2.48mm$ for the right coronary sinus, $18.61{\pm}2.26mm$ for the non coronary sinus and $17.95{\pm}19mm$ for the left coronary sinus. The circumference of the sinotubular junction was $70.73{\pm}5.94mm$ and that of the aortic annulus was $77.94{\pm}5.63mm$. There is no correlation between age and STJ, aortic annulus and the ratio of STJ of aortic annulus respectively (p=0.920, p=0.111, p=0.073). The tilting angle of the sinotubular junction and aortic annulus is from $2.03^{\circ}$ to $7.77^{\circ}$ $(mean=4.90^{\circ})$. Conclusion: The intercommissural distance and the height of the sinus were largest in the right coronary sinus, and the position of the sinotubular junction to the aortic annulus is obliquely tilted levo-posteriorly.

Quality Changes of Commercial Kimchi Products by Different Packaging Methods (소포장 김치의 포장방법별 품질특성 변화)

  • Hong, Seok-In;Park, Jin-Sook;Park, Noh-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.112-118
    • /
    • 1995
  • The effect of various packaging methods on kimchi quality was investigated in order to develop the packaging techniques for preventing commercial kimchi products from inflation and explosion, due to fermentative gas evolved during storage and distribution. Kimchi was packaged in different methods; 1) atmospheric packaging(AP), 2) check valve packaging(CV), 3) double packaging(DP), and 4) vacuum packaging(VP). The quality of kimchi during storage at $10^{\circ}C$ was evaluated in terms of gas composition, free volume, pH, titratable acidity color index and sensory properties. The gas composition inside packages showed different curves according to the packaging methods. Due to fermentative gas accumulation in both AP and CV, $CO_2$ concentration increased by 2 stepwise pattern, while $O_2$, concentration decreased exponentially. In DP, $O_2$ concentration remained constant, but $CO_2$ concentration increased by 2 stepwise pattern and then decreased. In contrast, VP produced low $O_2$ and high $CO_2$ concentrations only at the end of storage. The free volume in both AP and CV showed typical sigmoidal curves similar to $CO_2$ concentration changes. It remained constant in DP, but started to increase at the late stage of storage in VP. There was no significant effect of packaging methods on pH changes of kimchi. In titratable acidity, DP maintained relatively higher than others. Regarding to the color change of crushed kimchi juice in all packages, L and b values decreased exponentially but a value remained constant during storage. Color index(L b/a) of crushed kimchi juice decreased exponentially and remained constant at the end of storage. The growth of lactic acid bacteria was VP, CV, AP, DP in increasing order. In sensory test, the sourness scores of DP were fairly higher than those of others, but the texture was not significantly affected by the packaging methods. The preference for kimchi showed VP>AP, CV>DP in order of score. In this study, it could be proposed to employ DP and VP method as the effective packaging techniques for preventing commercial kimchi products from inflation.

  • PDF

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Changes in Immunogenicity of Preserved Aortic Allograft (보존된 동종동맥편 조직의 면역성 변화에 관한 연구)

  • 전예지;박영훈;강영선;최희숙;임창영
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1173-1181
    • /
    • 1996
  • The causes of degenerative changes in allograft cardiac valves are not well known to this day. Today's preserved allografts possess highly viable endothelial cells and degeneration of allografts can be facilitated by immune reaction which may be mediated by these viable cells. To test the antigenicity of endothelial cells, pieces from aortic wall were obtained from fresh and cryo-preserved rat allograft. Timings of sampling were prior to sterilization, after sterilization, after 1, 2, 7, 14 days of fresh preservation and cryopreservation. Endothelial cells were tested by immunohistochemical methods using monoclonal antibodies to MHC class I(MRC OX-18), class II(MRC OX-6) and ICAM-1 antigens. After transplantation of each group of aortic allograft at the subcutaneous layers of rats, population of CD4$^{+}$ T cell and CD8$^{+}$ T cell were analyzed with monoclonal antibodies after 1, 2, 3, 4, 6 and 8 weeks. MHC class I expression was 23.95% before preservation and increased to 35.53~48.08% after preservation(p=0.0183). MHC Class II expression was 9.72% before preservation and 10.13~13.39% after preservation(P=0.1599). ICAM-1 expression was 15.02% before preservation and increased to 19.85~35.33% after preservation(P=0.001). The proportion of CD4$^{+}$ T-cell was 42.13% before transplantation. And this was 49.23~36.8% after transplantation in No treat group (p=0.955), decreased to 29.56~32.80% in other group(p=0.0001~0.008). In all the groups, the proportion of CD8$^{+}$ T-cell increased from 25.57% before transplantation to 42.32~58.92% after transplantation(p=0.000l~0.0002). The CD4$^{+}$/CD8$^{+}$ ratio decreased from 1.22~2.28 at first week to 0.47~0.95 at eighth week(p=0.0001). The results revealed that the expression of MHC class I and ICAM-1 in aortic allograft endothelium were increased but that of MHC class II were not changed, despite the different method of preservation. During 8 weeks after transplantation of aortic allograft, the subpopulations of CD4$^{+}$ T cell were not changed or only slightly decreased but those of CD8$^{+}$ T cell were progressively increased.ely increased.

  • PDF