• Title/Summary/Keyword: test strip

Search Result 444, Processing Time 0.03 seconds

Comparison of visual colorimetric Analysis and neural network algorithm in urine strip classification (뇨 스트립 분류에서 육안비색법과 신경회로망 알고리즘 비교)

  • Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1394-1397
    • /
    • 2020
  • The urine test used as a basic test method of in vitro diagnosis for health care has been used for a long time to be simple and convenient. The urine test method is using a color that appears depending on the change in the ion concentration that reacts over time buried in the standard color test paper(Strips) with a urine sample applied to some reaction reagents. In this paper, it was proposed a neural network algorithm to obtain a suitable and reproducibility and accuracy classifier suitable for the urine analysis system. The experimental results were compared with the visual colorimetric analysis, and the neural network algorithm showed better results.

Experimental Study on Long-Term Performance Evaluation of Geosynthetic Strip Reinforcement (띠형 섬유보강재의 장기성능 평가를 위한 실험적 연구)

  • Lee, Kwang-Wu;Kim, Ju-Hyeung;Cho, Sam-Deok;Han, Jung-Geun;Yoon, Won-Il;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.4
    • /
    • pp.75-84
    • /
    • 2010
  • In this study, the long-term performance tests, which have extensibility, creep deformation, installation resistance and durability characteristic, is conducted to apply geosynthetic strip in field. The strength reduction factors using the test results are evaluated in order to calculate long-term design tensile strength. First, the creep deformation was evaluated by both the stepped isothermal method(SIM) and the time-temperature superposition(TTS) method. The creep reduction factor is reasonable to apply 1.6. Second, the result of installation damage test had little damage of yarn, which affected strength of reinforcement. Therefore, it can be analyzed that the installation damage of geosynthetic strip has little effect of long-term design tensile strength. Finally, the durability reduction factor considering chemical, biological and outdoor exposure resistance is reasonable to apply 1.1, which is considered the stability and economic efficiency of reinforced earth wall using geosynthetic strip.

  • PDF

Counter-Current Gas-Liquid Two-Phase Flow in Narrow Rectangular Channels with Offset Strip Fins (휜이 있는 협소 사각 유로에서 대향류 기/액 2상 유동)

  • Sohn, B.H.;Kim, B.J.;Jeong, S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.229-234
    • /
    • 2001
  • An adiabatic counter-current vertical two-phase flow of air and water in narrow rectangular channels with offset strip fm was investigated experimentally. Tests were systematically performed with downward liquid superficial velocities and upward gas velocities covering 0 to 0.06 m/s and 0 to 2.5 m/s ranges, respectively. Two-phase flow regimes were classified by examining the video images of flow patterns in transparent test sections of 760 mm long and 100 mm wide channel with gaps of 3.0 and 5.0 mm. The channel average void fraction was measured by the quick-closing valve method. Unlike the flow regimes in the channels without fin, where bubbly, slug, chum, and annular flow were identified, only bubbly and chum flow regimes were found for the channels with offset strip fin. However the existence of fin in the channels showed negligible effects on the void fraction. Instead counter-current flow limitations were found to happen at lower air superficial velocity once offset strip fin was introduced in narrow rectangular channels.

  • PDF

A Study on the High Efficiency PR Strip technology by using the Ozone Process (오존공정을 이용한 고효율 PR 제거기술 연구)

  • Son, Young-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.1
    • /
    • pp.22-27
    • /
    • 2007
  • we have been studied on the realization of the boundary layer controlled ozone process and related facilities in order to apply for the photo-resist strip process in the semiconductor and flat panel display manufacturing. By means of developing the technology for the high concentration ozone production, it was possible to realized the boundary layer control ozone process by vapor. As a result of the silicon wafer PR strip test, we obtained the strip rate of about 400nm/min at the ozone concentration of 16wt% and flow rate of 8[liter/min.].

The Effect of Oxide Layer Thickness to the Scale Defects Generation during Hot finish Rolling (열연사상 압연시 스케일 결함발생에 미치는 산화피막 두께의 영향)

  • 민경준
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.412-422
    • /
    • 1999
  • Scale defects generated on the strip surface in a tandem finishing mill line are collected from the strip trapped among the production mills by freezing the growing scale on the strip by the melt glass coating and shutting down the line simultaneously. The samples observed of its cross sectional figure showed the process of scale defect formation where the defects are formed at the base metal surface by thicker oxidized scale during each rolling passes. The properties of the oxidized layer growth both at rolling and inter-rolling are detected down sized rolling test simulating carefully the rolling condition of the production line. The thickness of the oxidized layer at each rolling pass are simulated numerically. The critical scale thickness to avoid the defect formation is determined through the expression of mutual relation between oxidized layer thickness and the lanks of the strip called quality for the scale defects. The scale growth of scale less than the critical thickness and also to keep the bulk temperature tuning the water flow rate and cooling time appropriately. Two units of Inerstand Cooler are designed and settled among the first three stands in the production line. Two units of scale defect is counted from the recoiled strip and the results showed distinct decrease of the defects comparing to the conventionaly rolled products.

  • PDF

Modeling of Stress-strain Curve for Cold Rolled Electrical Steel (냉간 압연된 전기강판의 응력-변형률 곡선 모델)

  • Yoo, U.K.;Byon, S.M.;Lee, Y.
    • Transactions of Materials Processing
    • /
    • v.17 no.4
    • /
    • pp.272-277
    • /
    • 2008
  • A constitutive equation of the electrical steel strip used for a raw material of transformer is proposed. The stress-strain behavior of electrical steel strip is quite different from that of common carbon steel and/or alloy steel. A series of tensile tests were performed with the specimens made from cold rolled strip. Several thicknesses of the strip were produced by a two-high (with upper and lower rolls) cold rolling pilot mill as reduction ratio increases from 10% to 90%. Its initial thickness of the strip was 2.5mm. Tensile specimens are cut out from the cold rolled strips. Mechanical properties of the steel are examined through rolling direction. Ramberg-Osgood model and the proposed equation are combined to describe the total behavior of stress-strain including instability region. The stress-strain curves calculated from the present constitutive equation are compared with those from experimentally obtained at each test condition of reduction ratios of specimen. Results show that the predicted stress-strain curves are in overall in a good agreement with measured ones.

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

Development on the High Concentration Ozone Generator System for the Semiconductor Photoresist Strip Process (반도체 감광막 제거공정 적용을 위한 고농도 오존발생장치 개발)

  • Son, Young-Su;Ham, Sang-Yong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.12
    • /
    • pp.591-596
    • /
    • 2006
  • we have been developed on the ultra high concentration ozone generator system which is the core technology in the realization of the semiconductor photoresist strip process using the ozone-vapor chemistry. The proposed ozone generator system has the structure of the surface discharge type which adopt the high purity ceramic dielectric tube. We investigate the performance of the proposed ozone generator system experimentally and the results show that the system has very high ozone concentration characteristics of $19.7[wt%/O_2]$ at the flow rate of $0.3[{\ell}/min]$ of each discharge cell. As a result of the silicon wafer photoresist strip test, we obtained the strip rate of about 400[nm/min] at the ozone concentration of $16[wt%/O_2]$ and flow rate of $8[{\ell}/min]$. So, we confirmed that it's possible to use the proposed high concentration ozone generator system for the ozone-vapor photoresist strip process in the semiconductor and FPD industry.

Clinical Implications of the Glucose Test Strip Method for Early Detection of Pulmonary Aspiration in Nasogastric Tube- Fed Patients (비위관영양환자의 폐흡인 조기확인을 위한 포도당 검사지[glucose test strips] 방법의 임상적 유용성)

  • Kim Hwa-Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.7
    • /
    • pp.1215-1223
    • /
    • 2004
  • Purpose: This study was performed to test the clinical usefulness of the glucose test strip method for early detection of pulmonary aspiration in tube fed patients. Method: The subjects for the study were 36 patients who were receiving enteral feedings and 39 patients who were not given enteral feedings. For the analysis, the tube fed patients were divided into two groups (clinically significant aspiration and no aspiration) according to criteria. Result: The mean glucose concentration of tracheal secretions from non enteral fed patients was 26.35mg/dl and were lower than those concentrations found in tube fed patients (32.75mg/dl). The mean glucose concentration of the aspiration group was 45.60mg/dl and the glucose concentration of the non aspiration group was 19.93mg/dl. The difference was statistically significant (t=2.163, p=.038). More subjects in the no aspiration group ($73\%$) than the aspiration group ($56\%$) had glucose concentrations below 20mg/dl. After deleting the cases that had samples containing blood, glucose concentrations of tracheal aspirates were lower in both groups. Conclusion: The glucose level of the aspiration group was significantly lower than the no aspiration group and more subjects in the aspiration group had a glucose level higher than 101mg/dl. Therefore, the glucose test of tracheal secretions in tube fed patients could be a desirable test for screening for tracheal aspiration. Especially the patient who is showing repeatedly high glucose levels should not be given feedings until reassessment is completed.

Role of $Na^+\;-K^+$ Pump on Endothelium-dependent Relaxation

  • Sung, Sang-Hyun;Roh, Joon-Ryang;Park, Tae-Sic;Suh, Suk-Hyo;Hwang, Sang-Ik;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.199-207
    • /
    • 1993
  • To study the underlying mechanism through which the endothelium-dependent relaxation is inhibited by blocking the $Na^+\;-K^+$ pump, the effects of $Na^+\;-K^+$ pump blockade on the release of EDRF and its relaxing activity were examined, using organ bath study, bioassay technique, and cGMP measurement. Endothelium-dependent relaxation was attenuated by blocking the $Na^+\;-K^+$ pump in the vascular ring with intact endothelium. In bioassay experiment EDRF release was decreased with the blockade of the $Na^+\;-K^+$ pump in the EDRF donor strip. Endothelium-dependent increase of cGMP level was suppressed by inhibiting the $Na^+\;-K^+$ pump in the test strips. The magnitude of relaxation of test strip which was induced by the perfusate that had passed through the EDRF donor strip was decreased with the blockade of the $Na^+\;-K^+$ pump in the test strip. Therefore, it could be suggested that the attenuation of endothelium-dependent relaxation caused by inhibiting $Na^+\;-K^+$ pump activity is due to both the decreased release of EDRF from endothelial cells and the decreased sensitivity of the smooth muscle cells to EDRF.

  • PDF