• Title/Summary/Keyword: test slabs

Search Result 369, Processing Time 0.037 seconds

Estimation of impact characteristics of RC slabs under sudden loading

  • Erdem, R. Tugrul
    • Computers and Concrete
    • /
    • v.28 no.5
    • /
    • pp.479-486
    • /
    • 2021
  • Reinforced concrete (RC) slabs are exposed to several static and dynamic effects during their period of service. Accordingly, there are many studies focused on the behavior of RC slabs under these effects in the literature. However, impact loading which can be more effective than other loads is not considered in the design phase of RC slabs. This study aims to investigate the dynamic behavior of two-way RC slabs under sudden impact loading. For this purpose, 3 different simply supported slab specimens are manufactured. These specimens are tested under impact loading by using the drop test setup and necessary measurement devices such as accelerometers, dynamic load cell, LVDT and data-logger. Mass and drop height of the hammer are taken constant during experimental study. It is seen that rigidity of the specimens effect experimental results. While acceleration values increase, displacement values decrease as the sizes of the specimens have bigger values. In the numerical part of the study, artificial neural networks (ANN) analysis is utilized. ANN analysis is used to model different physical dynamic processes depending upon the experimental variables. Maximum acceleration and displacement values are predicted by ANN analysis. Experimental and numerical values are compared and it is found out that proposed ANN model has yielded consistent results in the estimation of experimental values of the test specimens.

Experimental studies of headed stud shear connectors in UHPC Steel composite slabs

  • Gao, Xiao-Long;Wang, Jun-Yan;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • v.74 no.5
    • /
    • pp.657-670
    • /
    • 2020
  • Due to the high compressive and tensile strength of ultra-high performance concrete (UHPC), UHPC used in steel concrete composite structures provided thinner concrete layer compared to ordinary concrete. This leaded to the headed stud shear connectors embedded in UHPC had a low aspect ratio. In order to systematic investigate the effect of headed stud with low aspect ratio on the structural behaviors of steel UHPC composite structure s this paper firstly carried out a test program consisted of twelve push out specimens. The effects of stud height, aspect ratio and reinforcement bars in UHPC on the structural behaviors of headed studs were investigated. The push out test results shows that the increasing of stud height did not obviously influence the structural behaviors of headed studs and the aspect ratio of 2.16 was proved enough to take full advantage of the headed stud strength. Based on the test results, the equation considering the contribution of weld collar was modified to predict the shear strength of headed stud embedded in UHPC. The modified equation could accurately predict the shear strength of headed stud by comparing with the experimental results. On the basis of push out test results, bending tests consisted of three steel UHPC composite slabs were conducted to investigate the effect of shear connection degree on the structural behaviors of composite slabs. The bending test results revealed that the shear connection degree had a significantly influence on the failure modes and ultimate resistance of composite slabs and composite slab with connection degree of 96% in s hear span exhibited a ductile failure accompanied by the tensile yield of steel plate and crushing of UHPC. Finally, analytical model based on the failure mode of composite slabs was proposed to predict the ultimate resistance of steel UHPC composite slabs with different shear connection degrees at the interface.

Strengthening Effects of Slabs by Aramid Fiber Sheet (아라미드섬유 쉬트에 의한 슬래브의 보강효과)

  • Yeon, Kyu-Seok;Kang, Young-Sug;Kim, Hyung-Woo;Lee, Youn-Su;Kim, Nam-Gil
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.105-113
    • /
    • 1999
  • This study was conducted to evaluate the structural behaviors of Aramid fiber sheet reinforced slabs. Seven concrete slabs with $45{\times}8.5{\times}200cm$ were made for this experiment one slab with out being reinforced completely loaded until failure and the maximum load was obtained from this test. 70% of the maximum load was applied to 3 Aramid fiber sheet reinforced slabs after cracking and to the rest of 3 Aramid fiber sheet reinforced slabs without loading and cracking. Test results shows that maximum loading flexural rigidity and ductility for the Araimid fiber sheet reinforced slabs after initial cracking are similar as those for the Armied fiber sheet reinforced slabs without loading and cracking.

Impact resistance of polypropylene fiber reinforced concrete two-way slabs

  • Al-Rousan, Rajai Z.;Alhassan, Mohammed A.;Al-Salman, Harith
    • Structural Engineering and Mechanics
    • /
    • v.62 no.3
    • /
    • pp.373-380
    • /
    • 2017
  • Concrete structures are often subjected to long-term static and short-term dynamic loads. Due to a relatively low tensile strength and energy dissipating characteristics, the impact resistance of concrete is considered poor. This study investigates the feasibility of using polypropylene fibers to improve the impact resistance of reinforced concrete slabs. Fourteen polypropylene fiber reinforced concrete slabs were fabricated and tested using a drop weight test. The effects of slab thickness, fiber volume fractions, and impact energy on the dynamic behaviors were evaluated mainly in terms of impact resistant, crack patterns, and failure modes. The post impact induced strains versus time responses were obtained for all slabs. The results showed that adding the polypropylene fiber at a dosage of 0.90% by volume of concrete leads to significant improvement in the overall structural behavior of the slabs and their resistance to impact loading. Interestingly, the enhancement in the behavior of the slabs using a higher fiber dosage of 1.2% was not as good as achieved with 0.90%.

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • v.11 no.3
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

Tests of concrete slabs reinforced with CFRP prestressed prisms

  • Liang, Jiongfeng;Yu, Deng;Yang, Zeping;Chai, Xinjun
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.355-366
    • /
    • 2016
  • This paper reports the testing of concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) on the flexural behavior. Four concrete slabs were tested, a reference slab reinforced with steel bars, and three slabs reinforced with CFRP prestressed concrete prisms (PCP). All slabs were made with dimensions of 600mm in width, 2200mm in length and 150 in depth. All concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) exhibited CFRP bar rupture failure mode. It was shown that the application of the CFRP prestressed prisms can limit service load deflections and crack width, the increased level of prestress in the CFRP prestressed prism positively affected the maximum crack width. The deflection of concrete slabs reinforced with CFRP prestressed prisms decreased as prestress in the CFRP prestressed prism increased.

Performance Evaluation of Vertical Vibration of Precast Concrete Slabs (프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가)

  • Heo, Seok-Jae;Lee, Sang-Hyun;Cho, Seung-Ho;Chung, Lan;Kim, Sung-Bae;Park, Sung-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

Static Test on Aged RC Bridge Slabs Strengthened With TYFO Glassfibers (TYFO 유리섬유로 보강된 노후교량 상판에 대한 정적실험)

  • 송재필;김철우;김기봉;정영수;이광명
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.621-626
    • /
    • 1997
  • Recently, TYFO glassfibers have been used for strengthening n aged RC bridge slabs because of low material cost and easy repairing work. The purpose of this study is to experimentally and analytically investigate the effect of TYFO glassfibers for enhancing the capacity of aged RC bridge slabs. Tes result shows that yield and ultimate strength of RC slabs with TYFO are increased as 11~18% and 25~35% comparing with those for RC slabs without TYFO, respectively, Also, ductility of RC slabs strengthened with TYFO have been significantly increased. Further tests have been performing on aged RC bridge slabs strengthened with carbon fiber strips.

  • PDF

Behavior of reinforced lightweight aggregate concrete hollow-core slabs

  • Al-Azzawi, Adel A.;Al-Aziz, Basma M. Abdul
    • Computers and Concrete
    • /
    • v.21 no.2
    • /
    • pp.117-126
    • /
    • 2018
  • This research investigate the behavior of reinforced normal and lightweight aggregate concrete hollow core slabs with different core shapes, shear span to effective depth (a/d). The experimental work includes testing seven reinforced concrete slabs under two vertical line loads. The dimensions of slab specimens were (1.1 m) length, (0.6 m) width and (0.12 m) thickness. The maximum reduction in weight due to aggregate type was (19.28%) and due to cross section (square and circular) cores was (17.37 and 13.64%) respectively. The test results showed that the decrease of shear span to effective depth ratio from 2.9 to 1.9 for lightweight aggregate solid slab cause an increase in ultimate load by (29.06%) and increase in the deflection value at ultimate load or the ultimate deflection by (17.79%). The use of lightweight aggregate concrete in casting solid slabs give a reduction in weight by (19.28%) and in the first cracking and ultimate loads by (16.37%) and (5%) respectively for constant (a/d=2.9).The use of lightweight aggregate concrete in casting hollow circular core slabs with constant (a/d=2.9) (reduction in weight 32.92%) decrease the cracking and ultimate loads by (12%) and (5.18%) respectively with respect to the solid slab. These slab specimens were analyzed numerically by using the finite element computer program ANSYS. Good agreements in terms of behavior, cracking load (load at first visible crack) and ultimate load (maximum value of testing load) was obtained between finite element analysis and experimental test results.

Experimental investigation on the behaviour of UHPC-steel composite slabs under hogging moment

  • Gao, Xiao-Long;Wang, Jun-Yan;Bian, Chen;Xiao, Ru-Cheng;Ma, Biao
    • Steel and Composite Structures
    • /
    • v.42 no.6
    • /
    • pp.765-777
    • /
    • 2022
  • Ultra high performance concrete (UHPC) can be used in the UHPC-steel composite structures especially for bridge structures to achieve high stiffness and high fatigue resistance with low self-weight. The structural performances of UHPC-steel composite slabs subjected to hogging moment have a significant influence on the global stiffness and durability of UHPC-steel composite structures. In order to study the structural behaviors of non-steam-cured UHPC-steel composite slabs subjected to negative moment, five composite slabs combined the thin UHPC layers to steel plates via shear stud connecters with the diameter of 16mm were fabricated and tested under negative moment. The test program aimed to investigate the effect of stud spacing and longitudinal reinforcement ratios on the failure mode, load-deflection behaviors, cracking patterns, bond-slips, and carrying capacities of composite slabs subjected to negative moment. In addition, direct tensile tests for the dog-bone UHPC specimens with longitudinal reinforcement bars were carried out to study the effect of reinforcement bars on the tensile strength of UHPC in the thin structure members. Based on the experimental results, analytical models were also developed to predict the cracking load and ultimate load of UHPC-steel composite slabs subjected to negative moment.