• Title/Summary/Keyword: test instruments

Search Result 1,297, Processing Time 0.023 seconds

Equating Two Health-related Quality of Life Instruments Applied to Cancer Survivors Who Underwent Palliative Care

  • Bongsam Choi;Heesu Kim;Sunhwi Bang;Byunggwan Kim;Jaekwang Shim
    • Physical Therapy Korea
    • /
    • v.30 no.1
    • /
    • pp.32-40
    • /
    • 2023
  • Background: Equating is a statistical procedure used to create a common measurement scale across two instruments. Item-level information should be taken into consideration so that scores can communicate interchangeably across the instruments. Objects: To investigate a common measurement scale across two health-related quality of life questionnaires (HRQOL) applied to various cancer survivors who underwent palliative care in healthcare institutions. Methods: A total of 139 cancer survivors who underwent palliative care were recruited from two rehabilitation hospitals and an oriental medicine hospital. Participants consisted of various cancer survivors who presented to the sites for palliative care. They were asked to fill out Korean versions of the World Health Organization Quality of Life (WHOQOL-BREF) and EuroQOL-5 dimension (EQ-5D) questionnaires following the palliative care. For the item level comparison, the Rasch rating scale model was used to investigate how participants regarded individual test items of two instruments in relation to item difficulty calibrations. Results: All items except the three items fit the Rasch model. One item (anxiety/depression) of the EQ-5D and two items (dependence on medical aids and negative feelings) of the WHOQOL-BREF are misfit. The WHOQOL-BREF targets the survivors well, while the EQ-5D is able to target the survivors with lower HRQOL levels with some ceiling effects. By inspecting the item difficulty calibrations of the two instruments, five items of the WHOQOL-BREF are selected as common items in relation to the EQ-5D. These five items are considered compatible with each other. Differential item functioning (DIF) analysis reveals that the healthcare item of the WHOQOL-BREF vs the self-care item of the EQ-5D exhibits significant DIF. Conclusion: Findings suggest that one paired item should be taken into consideration when equating the WHOQOL-BREF and the EQ-5D applied to cancer survivors who underwent palliative care.

Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study

  • Liliana Machado Ruivo;Marcos de Azevedo Rios;Alexandre Mascarenhas Villela;Alexandre Sigrist de Martin;Augusto Shoji Kato;Rina Andrea Pelegrine;Ana Flavia Almeida Barbosa;Emmanuel Joao Nogueira Leal Silva;Carlos Eduardo da Silveira Bueno
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.49.1-49.8
    • /
    • 2021
  • Objectives: To evaluate the fracture incidence of Reciproc R25 instruments (VDW) used during non-surgical root canal retreatments performed by students in a postgraduate endodontic program. Materials and Methods: From the analysis of clinical record cards and periapical radiographs of root canal retreatments performed by postgraduate students using the Reciproc R25, a total of 1,016 teeth (2,544 root canals) were selected. The instruments were discarded after a single use. The general incidence of instrument fractures and its frequency was analyzed considering the group of teeth and the root thirds where the fractures occurred. Statistical analysis was performed using the χ2 test (p < 0.01). Results: Seven instruments were separated during the procedures. The percentage of fracture in relation to the number of instrumented canals was 0.27% and 0.68% in relation to the number of instrumented teeth. Four fractures occurred in maxillary molars, 1 in a mandibular molar, 1 in a mandibular premolar and 1 in a maxillary incisor. A greater number of fractures was observed in molars when compared with the number of fractures observed in the other dental groups (p < 0.01). Considering all of the instrument fractures, 71.43% were located in the apical third and 28.57% in the middle third (p < 0.01). One instrument fragment was removed, one bypassed, while in 5 cases, the instrument fragment remained inside the root canal. Conclusions: The use of Reciproc R25 instruments in root canal retreatments carried out by postgraduate students was associated with a low incidence of fractures.

Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files

  • Charlotte Gouedard;Laurent Pino;Reza Arbab-Chirani;Shabnam Arbab-Chirani;Valerie Chevalier
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.16.1-16.9
    • /
    • 2022
  • Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermos-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and Methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

A Study of Magnetic Fluid Seals for Blood Sealing

  • Tomioka, Jun;Fukaishi, Akira;Ohba, Takashi
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.373-374
    • /
    • 2002
  • Magnetic fluid seals are used in a wide variety of gas and dust sealing applications. However, it is difficult to seal for liquid because of its characteristic. This study will be a basic guide for a magnetic fluid seal for liquid, especially for blood to be practically used in medical instruments such as rotary blood pumps by clarifying its seal properties. Sealing pressure test, durability test, and hemolysis test have been conducted for this seal. In this study, magnetic fluid, sealing fluid, eccentricity ratio, revolution speed were selected as parameters. As results of the tests, it has been found that the properties of magnetic fluid seal depend on the solvent and the saturation magnetization of magnetic fluid. Therefore, the selection of magnetic fluid is important for this seal. It also has been found that eccentricity ratio of the shaft caused harmful effect for seal properties. In conclusion, it has been showed that magnetic fluid seals could be possibly used in medical instruments such as blood pumps when blood come in contact with magnetic fluids.

  • PDF

Development of an Integrated Measurement and Analysis System for DTV Field Test (DTV 필드테스트를 위한 통합 측정 및 분석 시스템 개발)

  • Kim Young-Min;Suh Young-Woo;Mok Ha-Kyun;Kwon Tae-Hoon;Lee Sang-Gil
    • Journal of Broadcast Engineering
    • /
    • v.10 no.4 s.29
    • /
    • pp.599-609
    • /
    • 2005
  • There are many test parameters in the DTV measurement, which uses several test measuring instruments and miscellaneous devices. To operate all of those devices and analyse test results is a tedious and time-consuming process with a high error rate committed by inexperienced test crews. In this paper, we propose an integrated DTV measurement and analysis system(IMAS) that remotely controls and manages any instruments with standard network interface. This system can take, organize, store the field data into an integrated database and easily produce systematic output according to user-defined form. It can also measure several types of digital broadcasting signals such as DTV, DMB, DAB with generalized measurement procedures. Proposed measurement system was applied in the DTV field test by KBS and proved that it could enhance the accuracy and efficiency of entire test sequences and also dramatically reduce measurement time compared to conventional measurement systems.

Development of Test Software Program and Digital Signal Processing Board for Array Module Signal Processing System (Array 검출 모듈 신호처리 시스템의 테스트 소프트웨어 프로그램 개발 및 디지털 신호처리 보드 개발)

  • Park, Geo;Kim, Young-kil;Lee, Jean
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.3
    • /
    • pp.499-505
    • /
    • 2018
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. In addition, it is necessary to localize the Array Detection System, which is a core component of the container search machine, to cope with the 100% pre-inspection of the container scheduled for 2018 in the United States. In this research, we propose a test software program developed by using TI-RTOS (Texas Instruments - Real Time Operating System) with a test digital signal processing board which is developed self development. We have developed a program that can test GPIO, SRAM, TCP/IP, and SDcard using M4 MCU. Also we propose a study on a self-developed Digital Signal Processing Board among the array detection systems that replace foreign products. We have developed a test board that can test M4 MCU and developed an X-Ray Detector Digital Signal Processing Board that combines MCU and FPGA.

Task-oriented Approach using Percussion Instruments in Chronic Stroke Patients Effect on Upper Limb Function: a Randomized Controlled Trial (타악기를 활용한 과제지향운동이 만성 뇌졸중 환자의 상지 기능에 미치는 영향)

  • Kim, Ju-Hak;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.4
    • /
    • pp.103-116
    • /
    • 2021
  • PURPOSE: This study examined the effects on the upper extremity function, muscle strength, and hand function of a task-oriented training approach using a percussion instrument for patients with chronic stroke. METHODS: Twenty-four chronic stroke patients accompanied with upper extremity hemiplegia were selected for research and were classified randomly into 12 experimental groups and 12 control groups. The experimental group performed a task-oriented approach, and the control group performed upper extremity occupational therapy. Stroke upper extremity test, Jebsen-Taylor Hand Function test, upper extremity muscle strength test, and hand muscle strength test were measured before and after training in the evaluation process. RESULTS: In the upper extremity test and Jebsen-Taylor test, there were no significant differences between the groups. In the upper extremity muscle strength test, there were significant differences in shoulder flexion, internal rotation, and elbow flexion in the experimental group. In the hand muscle strength test, there were significant differences in the grip, tip Pinch, lateral Pinch, and 3-jaw chuck in the experimental group and significant differences in only grip, tip pinch, and lateral pinch in the control group. In addition, there were significant differences in the lateral pinch compared to the amount of change. CONCLUSION: Task-oriented approach using percussion instruments for upper extremity rehabilitation in stroke patients is effective in the upper extremity function and strength, hand function, and strength.

Possibility of Local Recurrence Caused by Surgical Instruments in the Mouse Skin Cancer Model (백서 모델에서 수술 기구를 통한 피부악성종양의 국소 재발 가능성)

  • Kim, Gook-Jin;Lee, Hyoung-Suk;Kim, Nam-Gyun;Lee, Kyung-Suk;Kim, Jun-Sik;Park, Sang-Woo
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.339-344
    • /
    • 2011
  • Purpose: The goal of cancer surgery is complete removal of cancer tissue and prevention of recurrence. Surgeons can change the surgical instruments after total resection of the cancer mass. The purpose of this procedure is to prevent dissemination of the cancer cells attached to the surgical instruments. Authors hypothesize the possibility of local recurrence caused by the cancer cells attached to the surgical instruments in the skin cancer cases. Methods: Skin cancers were induced by using DMBA-TPA two-stage carcinogenesis model in 10 of Balb/c mice. In 2-weeks, skin cancer was developed in all 10 mice. cancer cell attached surgical instruments were made by pinching the removed cancer tissue using Adson tissue forcep 10, 20, 30 times each. To count number of cancer cells in each forcep with different number of pinching was done, the forceps were washed in 30 mL of the normal saline and Cytospin preparation was done. To make recurrence models from cancer cell attached surgical instrument, three incisions were made in normal skin of each mouse, and local seeding was done by pinching subcutaneous tissue in 10, 20, 30 times each by using Adson teeth forceps mentioned above as cancer cell attached surgical instrument. Results: All skin cancers were squamous cell carcinoma. Local recurrences were developed in 7 mice (3 in 10 times forceping site, 2 in 20 times forceping and 3 in 30 times forceping). In the cytospin test, the mean number of squamous cells in 100 microscope was 28.6 in 10 times, 47.2 in 20 times, 93.6 in 30 times, respectively. P value was 0.002 in Wilcoxon-Sign test. Conclusion: The number of cell count was significantly increased as number of pinching was increased. And these cells are able to induce local recurrence by local seeding. Considering this result, authors are able to confirm that the minimal handling in cancer surgery is important factor to prevent local recurrence.

Cross-cultural Validation of Instruments Measuring Health Beliefs about Colorectal Cancer Screening among Korean Americans

  • Lee, Shin-Young;Lee, Eunice E.
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.1
    • /
    • pp.129-138
    • /
    • 2015
  • Purpose: The purpose of this study was to report the instrument modification and validation processes to make existing health belief model scales culturally appropriate for Korean Americans (KAs) regarding colorectal cancer (CRC) screening utilization. Methods: Instrument translation, individual interviews using cognitive interviewing, and expert reviews were conducted during the instrument modification phase, and a pilot test and a cross-sectional survey were conducted during the instrument validation phase. Data analyses of the cross-sectional survey included internal consistency and construct validity using exploratory and confirmatory factor analysis. Results: The main issues identified during the instrument modification phase were (a) cultural and linguistic translation issues and (b) newly developed items reflecting Korean cultural barriers. Cross-sectional survey analyses during the instrument validation phase revealed that all scales demonstrate good internal consistency reliability (Cronbach's alpha=.72~.88). Exploratory factor analysis showed that susceptibility and severity loaded on the same factor, which may indicate a threat variable. Items with low factor loadings in the confirmatory factor analysis may relate to (a) lack of knowledge about fecal occult blood testing and (b) multiple dimensions of the subscales. Conclusion: Methodological, sequential processes of instrument modification and validation, including translation, individual interviews, expert reviews, pilot testing and a cross-sectional survey, were provided in this study. The findings indicate that existing instruments need to be examined for CRC screening research involving KAs.

Preference of undergraduate students after first experience on nickel-titanium endodontic instruments

  • Kwak, Sang Won;Cheung, Gary Shun-Pan;Ha, Jung-Hong;Kim, Sung Kyo;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.176-181
    • /
    • 2016
  • Objectives: This study aimed to compare two nickel-titanium systems (rotary vs. reciprocating) for their acceptance by undergraduate students who experienced nickel-titanium (NiTi) instruments for the first time. Materials and Methods: Eighty-one sophomore dental students were first taught on manual root canal preparation with stainless-steel files. After that, they were instructed on the use of ProTaper Universal system (PTU, Dentsply Maillefer), then the WaveOne (WO, Dentsply Maillefer). They practiced with each system on 2 extracted molars, before using those files to shape the buccal or mesial canals of additional first molars. A questionnaire was completed after using each file system, seeking students' perception about 'Ease of use', 'Flexibility', 'Cutting-efficiency', 'Screwing-effect', 'Feeling-safety', and 'Instrumentation-time' of the NiTi files, relative to stainless-steel instrumentation, on a 5-point Likert-type scale. They were also requested to indicate their preference between the two systems. Data was compared between groups using t-test, and with Chi-square test for correlation of each perception value with the preferred choice (p = 0.05). Results: Among the 81 students, 55 indicated their preferred file system as WO and 22 as PTU. All scores were greater than 4 (better) for both systems, compared with stainless-steel files, except for 'Screwing-effect' for PTU. The scores for WO in the categories of 'Flexibility', 'Screwing-effect', and 'Feeling-safety' were significantly higher scores than those of PTU. A significant association between the 'Screwing-effect' and students' preference for WO was observed. Conclusions: Novice operators preferred nickel-titanium instruments to stainless-steel, and majority of them opted for reciprocating file instead of continuous rotating system.