• Title/Summary/Keyword: test circuit

Search Result 1,839, Processing Time 0.032 seconds

Electrochemical Impedance Study on the Rebar Corrosion in Cement Mortar Containing Chloride Ions (전기화학적 임피던스법을 이용한 염함유 시멘트 모르터내의 철근부식 연구)

  • Nam, Sang Cheal;Paik, Chi-Hum;Cho, Won Il;Cho, Byung Won;Yun, Kyung Suk;Chun, Hai Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.811-816
    • /
    • 1998
  • Rebar corrosion in cement mortar containing chloride ions was investigated by electrochemical AC impedance spectroscopy. Corrosion of mild steel bar was accelerated by an acceleration test equipment in short period. Impedance values obtained from AC-impedance method could be adapted to the proposed electrochemical equivalent circuit model and they were consistent with calculated values obtained by CNLS fitting method. The weight loss of rebar could be calculated by charge transfer resistance($R_2$) with time and it was close to real value.

  • PDF

Design and Implementation of the Hi인 Power Ka-band Waveguide Diplexer with an E-plane T-junction (고전력 전송이 가능한 Ka 대역 E-평면 T형 분기 도파관 다이플렉서의 설계 및 구현)

  • Yun So-Hyeun;Uhm Man-Seok;Yom In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.732-739
    • /
    • 2005
  • In this paper, the design and implementation of the Ka-band(20/30 GHz) waveguide diplexer with an E-plane T-junction are described. The waveguide diplexer consists of a transmit filter and a receive filter combined to the antenna port via an E-plane T-junction. The reason why the E-plane T-junction structure was selected is to reduce PIM(Passive Intermodulation) level as the split-plane is located in the low electrical current zone. The optimization was performed using the equivalent circuit so that the computation time might reduce. The structure of the diplexer was designed to handle high power and the multipaction analysis was performed. The multipaction margin was greater than 12 dB and satisfied with ESA/ESTEC recommendation. The manufactured diplexer shows minimum return loss of 22 dB, maximum insertion loss of 0.20 dB and maximum isolation of -40 dB for both transmitted receive bands. Those mean the analysis results of the waveguide diplexer were well agreed with the electrical performance test.

Analysis Of Dielectric Recovery Characteristics for $SF_6$ Gas-Blast AFC ($SF_6$아크의 절연회복특성 해석)

  • Song, Gi-Dong;Lee, Byeong-Yun;Park, Gyeong-Yeop;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.273-284
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the dielectric recovery characteristics of two types of double-flow nozzles. A commercial CFD Program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of BBC. In order to investigate the state of the arc region after current zero, the simulation was carried out with four steps. They are cold gas flow analysis, steady state arc simulation, transient arc simulation before current zero, transient hot gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl′s mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The streamer criterion was introduced to evaluate the dielectric recovery characteristics after current zero. Compared with the results obtained by assuming the current zero state in the former studies, it has been found that the results obtained by considering the state before current zerowere more accurate.

A Study on the Tele-controller System of Navigational Aids Using Hybrid Communication (하이브리드 통신을 이용한 항로표지의 원격관리 제어시스템에 관한 연구)

  • Jeon, Joong-Sung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.842-848
    • /
    • 2011
  • A fabricated hybrid control board using multi-communication is designed with a low power 8-bit microcontroller, ATxmega128A1. The microcontroller consists of 8 UART (Universal asynchronous receiver/transmitter) ports, 2 kbytes EEPROM, 128 kbytes flash memory, 8 kbytes SRAM. The 8 URAT ports are used for a multi-communication modem, a GPS module, etc. The EEPROM is used for saving a configuration for running programs, and the flash memory of 128 kbytes is used for storing a F/W (Firm Ware), and the 8 kbytes SRAM is used for stack and for storing memory of global variables while running programs. If we use the multi-communication of CDMA, TRS and RF to remotely control Aid to Navigation, it is able to remove the communication shadow area. Even though there is a shadow area for an individual communication method, we can select an optimal communication method. The compatibility of data has been enhanced as using of same data frame per communication device. For the test, 8640 of data have been collected from each buoy during 30 days in every 5 minutes and the receiving rate of the data has shown more than 85 %.

Apparatus for Comparing Thermal Conductivity of Nanofluids and Base Fluid Using Simultaneously Measured Resistance Variation Signals from Two Hot Wire Sensors (동시에 측정된 두 열선센서의 저항변화 신호를 이용한 나노유체와 기본유체의 열전도율 비교장치)

  • Lee, Shin Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Exact comparisons of the thermal conductivities of the base fluid and a nanofluid are very important in the early stages of nanofluid development. A simple procedure of measuring the thermal conductivity of the two fluids by the transient hot wire method and numerically dividing these values is used for this purpose. However, because the experiments are not performed simultaneously and the physical properties of the measurement system are sometimes not properly known, large errors are incurred during the evaluation process. This article proposes a new apparatus for thermal conductivity comparison where the working principle is mainly based on relative measurement rather than absolute measurement. The measuring circuit and data processing steps are explained in detail; a validation test was performed using the well-known glycerine and engine oil.

Experimental and Analytical Studies on the Characteristics of Fast Switch in Combinations of Various Superconducting Tapes (다양한 선재 조합에 따른 이종 초전도 스위치의 특성 실험 및 분석)

  • Lee, Ji-Ho;Kim, Young-Jae;Na, Jin-Bae;Choi, Suk-Jin;Jang, Jae-Young;Hwang, Young-Jin;Kim, Jin-Sub;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.31-35
    • /
    • 2011
  • A Hybrid Fault Current Limiter(FCL) which has more advantages in fast response and thermal characteristics than a simple resistive FCL had been proposed by our group. The Hybrid FCL consists of a resistive FCL for the magnitude of the first peak of fault current, and a fast switch for detecting fault current and generating the repulsive force within a cycle in fault situation. In ideal case, the impedance of the fast switch wound with two other kinds of HTS tape is negligibly zero in normal operation. But, during the fault situation, each HTS tape has different quench characteristics because of asymmetric current distribution. And this phenomenon causes effective flux and this flux opens the switch through the repulsive force applied to a metal plate of the fast switch. The magnitude of the repulsive force affects the switching characteristics of the fast switch. It should be large enough to raise the metal plate up. Otherwise the arc re-out break which are caused by not enough repulsive force to raise the metal plate up can cause unintended operation of the fast switch. In this paper, the numerical calculation of the repulsive force applied to the metal plate of the fast switch in various combinations of HTS tapes was performed by using the short-circuit test and finite element method.

An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities (정보통신설비용 뇌서지 보호장치의 효과적인 설치기법)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.90-96
    • /
    • 2002
  • The AC power lines and signal lines of info-communication networks are muted on overhead poles and are exposed to lightning strikes. Due to the potential difference between groundings of the AC power lines and telecommunication lines, the electronic equipments connected to the telecommunication lines can easily be damaged by lightning surges. In this work, in order to develop the reliable ways to protect information and communication facilities from lightning surges, the reliability and performance of surge protective devices were experimentally investigated in actual-sized test circuit. The operation behaviors of surge protective devices against lightning surges from the AC power lines and telecommunication lines and the coordination effects of SPD installation method were evaluated. As a consequence, it was confirmed that the bypass arrester and common grounding system is very effective.

A Study on the Metallic Ion Migration in PCB (PCB의 금속 이온 마이그레이션 현상에 관한 연구)

  • 홍원식;송병석;김광배
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.68-68
    • /
    • 2003
  • 최근의 전자부품은 고밀도 고집적화 됨에 따라 여러 가지 문제점들이 발생되고 있다. 그 중 부품이 실장되는 부분에 사용되는 솔더나 전기적 회로를 구성하는 패턴간에 금속 이온 마이그레이션(Metallic Ion Migration)이 발생하여 전기적 단락(Short)를 유발함으로써 전자제품의 치명적 고장을 유발한다. 본 연구는 이온 마이그레이션 현상을 물방울시험(Water Drop Test)을 통하여 재현함으로써 발생 메카니즘을 확인하여 발생원인을 직접적으로 관찰하고, 각 종 패턴의 거리 및 전압에 따른 발생속도의 차이를 조사하기 위하여 수행되었다. 이러한 실험을 위하여 콤 패턴(Comb Pattern)의 FR-4 재질 인쇄회로기판(PCB : Printed Circuit Board)을 사용하였으며, 사용된 전극재질로는 Cu, SnPb, Au를 사용하였고, 패턴간 거리는 0.5, 1.0, 2.0mm의 3가지 종류로 구분하였다. 또한 패턴간에 인간 된 전압은 6.5V, 15V를 인가한 후 마이그레이션이 발생되는 시간을 측정하였다. 이러한 실험으로부터 다음과 같은 결론을 얻었다. (1) 6.5V의 인가전압에서는 Cu 패턴이 대체적으로 가장 빠르게 마이그레이션이 발생하였으며, 다음으로 Au가 발생하였고, Cu와 SnPb의 발생시간은 대체적으로 근사한 값을 나타내었다. 이것은 비슷한 평형전위를 갖는 재료는 마이그레이션 발생시간이 유사하게 나타나며, 높은 (+)전위를 갖을수록 발생시간이 지연됨을 알 수 있다. (2) 15V를 인가하였을 때 패턴간격이 0.5mm인 경우 Cu, Au, SnPb의 순으로 나타났으며, 1.0mm는 SnPb, Cu, Au, 2.0mm인 경우는 SnPb, Au, Cu의 순으로 마이그레이션이 발생하였다. 인가전압이 높은 경우 초기 발생에는 큰 차이가 없지만 수지상이 발생 후 성장하는데 많은 영향을 미치는 것으로 보인다. 이것은 초기 수지상의 형성에 큰 영향을 미치는 것은 재료의 평형전위에 의한 값이 좌우하지만, 수지상이 일정길이 이상 형성된 이후에는 성장속도가 평형전위에 따른 값과는 다소 다르게 나타남을 알 수 있다.

  • PDF

Design and implementation of ESD cable Disconnection Monitoring System (ESD 접지선 단선 모니터링 시스템 설계 및 구현)

  • Seong, Jung-Mo;Chung, Young-Suk;Park, Koo-Rack
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.77-82
    • /
    • 2017
  • In the splay manufacturing process, conveyor systems are widely used for conveying panels. In this conveyor, a large number of grounding lines are used in order to prevent a product failure due to static electricity. In many cases, the grounding line is disconnected due to the rotation of the transporting roller or curling, leading to product failure. In order to solve such a problem, there is a growing need for a system capable of detecting disconnection of a ground wire in real time. Therefore, in this paper, we propose a disconnection monitoring system of ESD (Electro-Static Discharge) ground wire caused by friction between the conveyor drive part and the panel. The proposed system is a monitoring system that can detect disconnection and disconnection of ground wire using ATmega 2560 and Wheatstone Bridge circuit. It can detect disconnection of ground wire immediately and can take measures to reduce the defect rate due to static electricity. The system proposed in this paper is expected to be applicable to the production and test equipments of all industries where the ground wire is used.

Implementation of Capacitance Measurement Equipment for Fault Diagnosis of Multi-channel Ultrasonic Probe (다중채널 초음파 프로브 고장진단을 위한 커패시턴스 측정 장치 구현)

  • Kang, Bub-Joo;Kim, Yang-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.175-184
    • /
    • 2016
  • In this paper, we propose the method to measure the capacitances using not LCR meter but capacitance to voltage(C/V) conversion. And we design the analog MUX circuits that convert 192 channels to 6 MUX channels in order to implement the diagnosis of multi-channel ultrasonic probe. This paper derives the conversion function that converts the digital voltage of each MUX channel to the capacitance using the least squares method because the circuit characteristics that convert the voltage of each MUX channel to the capacitance are different. The developed prototype illustrates the performance test results that the measure times are measured by within 4sec and the measure error rates of maximum, minimum, and average values are within 5% in terms of the repeated measurements of all 192 channels.