• 제목/요약/키워드: test case generation

검색결과 339건 처리시간 0.03초

음주운전자 275명 혈액 중 마약류 및 남용약물의 분석 (Distribution of Abused Drugs in 275 Alcohol-positive Blood Samples of Korean Driver)

  • 최혜영;이주선;최상길;김은미;김재균;김영운;임미애;정희선
    • 약학회지
    • /
    • 제52권2호
    • /
    • pp.137-146
    • /
    • 2008
  • Even though driving under the influence of drug (DUID) is a worldwide problem, we, Korea has no regulation system yet except for alcohol, and there are little cases reported related to DUID. In order to investigate the type of abused drugs for drivers in Korea, we tried to analyze controlled and non-controlled drugs in alcohol-positive blood samples. 275 whole bloods, which were positive for alcohol on the roadside test, were collected from the police for two months ($Nov.{\sim}Dec.$ 2006). The analytical strategy was constituted of three steps: First, alcohol in blood samples were confirmed and quantified by gas chromatography. Second, controlled drugs were screened by $Evidence_{investigator}\;^{TM}$ (Randox, U.K.) as preliminary test. It was based on immunoassay by biochip array analyzer. Nine groups of drug abuse were screened: amphetamines, methamphetamines, cannabis, cocaine, opiates, barbiturates, methadone, benzodiazepines I (oxazepam) & II (lorazepam). Finally, confirmation of these drugs was performed by GC-MS. Blood samples were extracted by solid-phase extraction by $RapidTrace^{TM}$ (Zymark, U.S.A.). After trimethylsilyl (TMS) derivatization, eluates were analyzed to GC-MS. Total 49 drugs were investigated in this study including controlled drugs, antidepressants, 1st generation antihistamines, dextromethorphan, nalbuphine, ketamine, etc. For rapid detection, we developed the automated identification system. It was made up a new software, "DrugMan", modified Chemstation data analysis menu and newly developed macro modules. A series of peak selection, identification and reporting of the results were performed automatically by this system. Concentrations of alcohol in 275 blood samples were ranged from 0.011 to 0.249% (average, 0.119%). Among 149 blood samples, just six samples (4.0%) were showed positive results to the immunoassay: one methamphetamine and five benzodiazepines group I. By GC-MS confirmation, only benzodiazepines were detected and methamphetamine was not detected from immunoassay positive blood sample. Besides these drugs, 5 chlorpheniramines, dextromethorphan, diazepam, doxylamine, ibuprofen, lidocaine and topiramate were also detected in whole bloods by GC-MS. Conclusively, the frequency of drug abuse for Korean drivers was relatively low. There was none case which illegal drug was detected. However these results were limited to alcohol positive blood samples, so it is necessary to analyze more samples including alcohol negative blood.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

응결시간조정에 의한 매트기초 매스 콘크리트의 온도균열저감 공법적용의 Mock-up Test (Mock-up Test of Temperature Crack Reduction Method Application by Setting Time Control of Mat Foundation Mass Concrete)

  • 한천구;이재삼;노상균
    • 한국건축시공학회지
    • /
    • 제9권4호
    • /
    • pp.55-61
    • /
    • 2009
  • 현재 국내의 건설공사현장에서는 도심부에 대형 건설사를 중심으로 초고층 건축물의 시공이 진행 중에 있다. 그런데 이러한 초고층 건축물의 기초는 상부의 큰 하중을 지지하기 위해 매우 두꺼운 매트 콘크리트가 필수적이다. 그러나 이와 같은 매스 콘크리트는 현장여건상 다량의 콘크리트를 동시에 타설할 수 없기 때문에 일체성에 의문이 제기되는 것은 물론이고 수화발열시간의 서로 다름에 따른 내응력에 의한 균열발생 가능성이 증가한다. 따라서 본 연구에서는 상기의 문제점을 해소시키고자 국내 모처에 건설되고 있는 초고층 건축물을 대상으로 초지연제의 응결시간차를 활용한 수평분할타설 건축 매스 콘크리트의 수화열 조정공법을 실제 건축현장에 적용하고자 Mock-up test를 통하여 그 효율성을 확인하였다. 실험결과 초지연제 투입 전 후슬럼프 플로우는 목표 지연시간이 길어질수록 다소 증가하였고, 공기량은 큰 차이는 없는 것으로 나타났으며, 응결시간은 목표 지연시간이 길어질수록 지연되었다. 목표 지연시간이 길어질수록 초기재령에서는 압축강도가 작게 나타났으나, 재령이 경과할수록 강도증진 폭이 크게 되어 재령 28일에서는 보통 콘크리트보다 동등 혹은 그 이상을 나타내었다. 또한 2단 및 4단으로 초지연제에 의한 응결시간차공법을 활용한 경우 하부와 상부간 콘크리트의 일체화 및 온도차를 낮추고, 수화열 피크시점이 후기로 늦어짐에 따라 균열발생가능성을 저하시키는 효과를 확인할 수 있었는데, 특히 4단 타설에서 가장 양호한 효과가 나타남을 확인할 수 있었다.

FAH gene novel mutation을 가진 만성형 Hereditary tyrosinemia 1형 (Chronic Hereditary Tyrosinemia Type I with Novel Mutation in FAH Gene)

  • 양성민;최효원;강윤구;이진성;남궁미경
    • 대한유전성대사질환학회지
    • /
    • 제20권2호
    • /
    • pp.55-62
    • /
    • 2020
  • HT-1은 FAH의 돌연변이에 의한 FAH의 결함으로 타이로신 대사의 중간산물인 FAA, SA가 간세포, 신세뇨관 세포에 축적되어 증상을 일으키는 대사이상 질환의 일종이다. 생후 6개월 내에 증상이 발현되는 급성형의 경우 간기능 저하에 따른 간부전, 응고장애, Fanconi 증후군, FAA 축적에 의한 델타-아미노레부릭산 탈수효소의 기능 저하에 의한 포르피린증 유사 증상이 발생한다. 증상이 생후 12개월 이후 발현되는 만성형의 경우 간경화, 간세포암종, 저인산혈증 구루병, 인지기능 저하와 같은 증상이 발생할 수 있다. 본 증례는 생후 20개월 경 간비장비대, 내반슬, 대상산증으로 대사이상질환 감별을 위하여 시행한 탠덤매스 분석에서 특이 소견이 보고되지 않았으나, 57개월에 시행한 복부 초음파 검사에서 간경화, 소변 유기산 분석에서 SA 상승, NGS에서 FAH 돌연변이 c.107T>C (p.Ile 36Thr), c.614T>C (pPhe205Ser)가 확인되어 HT-1이 진단된 증례로, 환아는 현재까지 NTBC 및 단백제한식이를 유지하며 특이 합병증 없이 외래 추적관찰 중이다. HT-1은 혈장 타이로신 농도가 증가하지 않는 경우도 있으며, 만성형의 경우 임상양상이 생후 12개월 이후에 나타나므로 탠덤매스 검사에서 음성 소견이 보고되어도 임상적으로 의심되는 경우 소변 유기산 분석과 같은 추가적 검사가 필요하다. 또한 기존의 탠덤매스 분석을 통하여는 HT-1이 진단되지 않는 경우가 있을 수 있어, 신생아 선별검사에서 혈장 타이로신 농도뿐 아니라 SA 농도도 추가로 확인하는 것의 비용 편익에 대한 추가적 연구가 필요하다.

EEG 신호 및 사물인터넷 기반 실내 환경 제어 시스템 (Indoor Environment Control System based EEG Signal and Internet of Things)

  • 정해성;이상민;권장우
    • 재활복지공학회논문지
    • /
    • 제11권1호
    • /
    • pp.45-52
    • /
    • 2017
  • EEG 신호는 신체적으로 불편함을 가지고 있는 사용자에게서도 동일하게 발생되는 신호로써 차세대 인터페이스로 각광받고 있다. 본 논문에서는 사용자의 EEG 신호를 이용하여 감성적인 정보처리와 논리적인 정보처리를 보조하는 실내 환경을 제어하는 사물인터넷 시스템을 제안한다. 제안된 시스템은 EEG 측정 장치, EEG 시뮬레이션 소프트웨어, 실내 환경 제어 장치로 구성된다. 실험 데이터로는 편안한 상태에서 발생되는 감성적인 정보처리에 대한 EEG 신호 데이터와 집중 시에 발생되는 논리적인 정보처리에 대한 EEG 신호 데이터를 사용한다. 측정된 신호에서는 ICA 알고리즘이 적용하여 잡음이 제거되고 베타파만을 추출한다. 이후 SVM을 통한 학습 및 테스트 과정을 거치게 된다. 피험자는 EEG 시뮬레이션 소프트웨어를 통해 EEG 신호 정확도 향상 훈련을 거친 결과 평균 82.69%의 정확도를 보였다. EEG 측정 장치로부터 입력되는 EEG 신호는 Serial 통신을 통해 EEG 시뮬레이션 소프트웨어로 전송되며 감성적인 정보처리와 논리적인 정보처리를 분류하여 제어 명령이 생성된다. 이후 생성된 제어 명령은 Zigbee 통신을 통해 실내 환경 제어 장치로 전달되어 감성적인 정보처리일 경우 은은한 조명과 클래식 음악이 출력되고 논리적인 정보처리일 경우 밝은 조명과 함께 학습용 백색소음이 출력된다. 제안한 시스템은 BCI 기반 소프트웨어 및 디바이스 제어에 응용될 수 있어 몸이 불편한 사용자가 자신의 신체적인 한계를 극복하는 것을 가능하게 한다.

질소 분위기에서 저잔사 플럭스를 사용한 마이크로 솔더링에 관한 연구 (The Study on Micro Soldering Using Low-Residue Flux in $N_2$Atmosphere)

  • 최명기;정재필;이창배;서창제;황선효
    • 마이크로전자및패키징학회지
    • /
    • 제7권4호
    • /
    • pp.7-15
    • /
    • 2000
  • 질소분위기 중에서 솔더 접합부의 특성 및 solderability을 검토하기 위하여 대기분위기와 질소분위기에서의 젖음성을 평가하였다. 또한 솔더접합부의 브리지결함(bridge defect)을 대기와 질소분위기 중에서 비교 검토하였다. 이 결과, 질소분위기 중에서 Cu표면을 사포로 연마한 시편, Cu표면에 Sn-Pb 및 Sn으로 도금한 시편에서 젖음성이 향상되었다. 대기분위기에 비해 젖음시간은 약 0.2~0.45초 정도 시간이 감소하였고, 최대젖음력 ($F_{max}$)도 대기중에 비해 약 1.8~2.8 N 정도가 커졌다. 질소유량에 따른 젖음시간($t_2$)과 젖음력을 측정한 견과 질소유량이 10 1/min에서 30 1/min으로 증가함에 따라 대기중 분위기에 비해 젖음시간($t_2$)는 약 0.25초 정토 감소하였고, 젖음력은 2.3 N 정도 상승하였다. 따라서, 질소분위 기에서 무세정용 플럭스를 사용해도 젖음성이 떨어지는 것을 보완 할 수 있다. 질소분위기에서는 젖음성을 향상시키고 산화물(dross)를 억제시켜주어 대기 중 보다 브리지 (Bridge)발생률이 25~76%정도 떨어졌다. 브리지 발생률은 피치간격이 미세할수록 질소분위기가 대기 중 보다 감소하였다.

  • PDF

고로수쇄(高爐水碎)슬래그 혼합(混合)시멘트의 알칼리 자극제(刺戟劑)로 부산소석회(副産消石灰)의 활용(活用) (Use of By-product Hydrated Lime as Alkali Activator of Blast Furnace Slag Blended Cement)

  • 조진상;유영환;최문관;조계홍;김환;연규석
    • 자원리싸이클링
    • /
    • 제19권3호
    • /
    • pp.33-44
    • /
    • 2010
  • 본 연구에서는 아세틸렌가스 제조 공정에서 배출되어 나오는 부산소석회에 대한 고로수쇄슬래그의 알칼리 활성화제로서의 활용 가능성을 조사하고자 하였다. 부산소석회의 물리 화학적 분석을 실시하였으며, 알칼리 활성화제로서의 특성분석을 위하여 세 가지 형태로 부산소석회를 사용하였다. 부산소석회는 고로수쇄슬래그에 0, 10, 20, 30 wt.% 첨가하였으며, 소석회가 혼합된 고로수쇄슬래그를 보통포틀랜드시멘트에 0, 10, 30, 50 wt.%첨가하여 수화 및 물리적 특성을 조사하였다. 수화특성 분석결과 $800^{\circ}C$에서 열처리 후 재수화 시킨 소석회를 사용한 경우 다른 시료들 보다 높은 수화율을 보였다. 압축강도실험결과 325 mesh 이하크기의 부산소석회와 열처리 후 재수화시킨 소석회를 사용한 경우 수화 7일부터 OPC 보다 높은 강도 값을 나타내었으며, 325 mesh 이하크기 부산소석회를 활성화재로 사용한 OPC50 wt.%-BFS 45 wt.%-AA5 wt.%계에서 가장 높은 압축강도를 보였다.

Public Library 2.0 기반 지역 커뮤니티지식정보시스템 개념적 설계 (A Study on Conceptual Design of Local Community Knowledge Information System Based on Public Library 2.0)

  • 박미영;승현우
    • 한국비블리아학회지
    • /
    • 제21권1호
    • /
    • pp.193-209
    • /
    • 2010
  • 도서관 서비스 혁신이란 지식정보화의 원천기술을 활용하여 '문화적 선도자로서의 변화'를 주도하고 하나의 시스템을 형성해 가면서 공유, 피드백 관계를 통해 새로운 지식을 창출, 상호작용이 활발한 특성화된 고유한 도서관을 만드는 것이다. 본 연구에서는 Public Library 2.0 서비스 모델을 기반으로 도서관의 서비스 혁신을 통한 디지털 지식정보화 시대에 공공도서관의 새로운 비전을 제공하고자 한다. 이를 위해 Public Library 2.0 기반 커뮤니티지식정보시스템 구현을 위한 개념적 설계를 목적으로 하며 연구내용과 연구방법은 다음과 같다. 첫째, 국내외 문헌조사를 통하여 Library 2.0의 정의, 원칙과 구성요소를 조사 분석하여 혁신을 주도하는 Library 2.0 서비스 모델을 제시하였다. 둘째, 국내 외 Library 2.0의 협력 기술인 블로그, 위키, 인스텐트 메세징, 포드캐스팅, 소셜네트워킹, 플리커를 중심으로 적용 사례의 유용성을 조사하였다. 셋째, Public Library 2.0의 정의와 원칙을 살펴보고 Public Librayr 2.0 기반 커뮤니티지식정보시스템 개념적 설계를 통해 공공도서관의 새로운 비전을 제시하였다. 본 연구는 차세대 공공도서관을 위한 개념적 설계를 위한 것으로 시스템 구현과 테스트를 위한 후속연구가 요구된다.

Ceftizoxime 투약 후 면역용혈빈혈 및 다발장기부전 (Ceftizoxime-induced immune hemolytic anemia associated with multi-organ failure)

  • 허진영;안아리;김형석;권석운;안수종;이재용;권병수;오은혜;박도현;허진원
    • Journal of Yeungnam Medical Science
    • /
    • 제34권1호
    • /
    • pp.123-127
    • /
    • 2017
  • Drug-induced immune hemolytic anemia (DIIHA) is a rare side effect of drugs. DIIHA may cause a systemic inflammatory response that results in acute multi-organ failure and death. Ceftizoxime belongs to the class of third generation cephalosporins, which are the most common drugs associated with DIIHA. Herein, we present a case of a 66-year-old man who developed fatal DIIHA after receiving a second dose of ceftizoxime. He was admitted to receive photodynamic therapy. He had a history of a single parenteral dose of ceftizoxime 3 months prior to admission. On the day of the procedure - shortly after the infusion of ceftizoxime - the patient's mental status was altered. The blood test results revealed hemolysis. Oliguric acute kidney injury developed, and continuous renal replacement therapy had to be applied. On the suspicion of DIIHA, the patient underwent plasmapheresis. Diagnosis was confirmed by a detection of drug-dependent antibody with immune complex formation. Although his hemolysis improved, his liver failure did not improve. He was eventually discharged to palliative care, and subsequently died.

종류식 환기 시스템에서 임계속도 도달 전 스모크 확산 영역에 관한 실험적 연구 (An experimental study on the smoke-spread region before reaching the critical velocity for the case of fires in tunnels employing longitudinal ventilation system)

  • 김영민;윤성욱;윤찬훈;김진
    • 터널과지하공간
    • /
    • 제16권6호
    • /
    • pp.526-535
    • /
    • 2006
  • 본 연구에서는 장대터널 화재 시 발생하는 스모크의 거동특성을 파악하기 위해 축소모형실험을 실시하였다. Froude 상사를 기초로 실제 터널을 1/50로 축소한 20 m 의 아크릴 터널 모형을 제작하였으며, 파라핀 기체로 만든 스모크를 터널 내부에 주입시킴으로써 20MW의 실제 화재를 모사하였다. 실험에서 화재 발생 약 2분 후에 스모크는 부력효과의 감소로 아래로 하강하였으며, 제트팬 가동 전까지 4분 동안 스모크는 약 90 m를 이동하였다. 제트팬이 가동되고 기류속도가 임계속도 (도로터널 화재 중 발생하는 스모크의 역기류를 제압하기 위한 최소 공기속도)에 가까워질수록 스모크의 제어가 효율적으로 이루어지며, 스모크의 분포는 화원에서 약 3 m 정도로 더 이상 탈출 방향으로의 스모크 전파가 이루어지지 않았다. 하지만, 제트팬 가동 초기에 스모크의 제어가 거의 이루어지지 않음을 보였고 오히려 이 단계에서 탈출자의 호흡선 차단 등의 위험요소가 내재되어 있음을 알 수 있었다.