• 제목/요약/키워드: tensioning

검색결과 253건 처리시간 0.026초

Long term health monitoring of post-tensioning box girder bridges

  • Wang, Ming L.
    • Smart Structures and Systems
    • /
    • 제4권6호
    • /
    • pp.711-726
    • /
    • 2008
  • A number of efforts had been sought to instrument bridges for the purpose of structural monitoring and assessment. The outcome of these efforts, as gauged by advances in the understanding of the definition of structural damage and their role in sensor selection as well as in the design of cost and data-effective monitoring systems, has itself been difficult to assess. The authors' experience with the design, calibration, and operation of a monitoring system for the Kishwaukee Bridge in Illinois has provided several lessons that bear upon these concerns. The systems have performed well in providing a continuous, low-cost monitoring platform for bridge engineers with immediate relevant information.

모델 실험체를 이용한 공동주택 바닥충격음 저감에 관한 실험적 연구 (An Experimental Study on the Reduction of Floor Impact Sound in Apartment Houses by using Model Test)

  • 김항;기노갑;박현구;송민정;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1044-1047
    • /
    • 2004
  • This aim of this study is is an experimental study to introduce the Reduction method of Floor Impact Sound in Apartment Houses by using Model Test, We are measured the floor impact sound in Rahamen and Apartment with Shear Wall and Post-tensioning. There is comparison between Rahmen Structure and Apartment with Shear Wall. The main results from this study are effective in reduction of heavt-weight The slab was constructed by rahamen structure. Heavy-weight can reduced by upgrading naturial frequency of floor impact sound in rahmen structure.

  • PDF

Modeling of post-tensioned one-way and two-way slabs with unbonded tendons

  • Kim, Uksun;Huang, Yu;Chakrabarti, Pinaki R.;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • 제13권5호
    • /
    • pp.587-601
    • /
    • 2014
  • A sophisticated finite element modeling approach is proposed to simulate unbonded post-tensioned concrete slabs. Particularly, finite element contact formulation was employed to simulate the sliding behavior of unbonded tendons. The contact formulation along with other discretizing schemes was selected to assemble the post-tensioned concrete system. Three previously tested unbonded post-tensioned two-way and one-way slabs with different reinforcement configurations and boundary conditions were modeled. Numerical results were compared against experimental data in terms of global pressure-deflection relationship, stiffness degradation, cracking pattern, and stress variation in unbonded tendons. All comparisons indicate a very good agreement between the simulations and experiments. The exercise of model validation showcased the robustness and reliability of the proposed modeling approach applied to numerical simulation of post-tensioned concrete slabs.

Interface slip of post-tensioned concrete beams with stage construction: Experimental and FE study

  • Low, Hin Foo;Kong, Sih Ying;Kong, Daniel;Paul, Suvash Chandra
    • Computers and Concrete
    • /
    • 제24권2호
    • /
    • pp.173-183
    • /
    • 2019
  • This study presents experimental and numerical results of prestressed concrete composite beams with different casting and stressing sequence. The beams were tested under three-point bending and it was found that prestressed concrete composite beams could not achieve monolith behavior due to interface slippage between two layers. The initial stress distribution due to different construction sequence has little effect on the maximum load of composite beams. The multi-step FE analyses could simulate different casting and stressing sequence thus correctly capturing the initial stress distribution induced by staged construction. Three contact algorithms were considered for interaction between concrete layers in the FE models namely tie constraint, cohesive contact and surface-to-surface contact. It was found that both cohesive contact and surface-to-surface contact could simulate the interface slip even though each algorithm considers different shear transfer mechanism. The use of surface-to-surface contact for beams with more than 2 layers of concrete is not recommended as it underestimates the maximum load in this study.

비부착 포스트텐션 정착구역 설계를 위한 파열력 산정 방법 (Bursting Force Equation for Design in Unbonded Post-Tensioned Anchorage Zone)

  • 노경민;이영학
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.21-26
    • /
    • 2018
  • For evaluating equations of bursting force in different codes, comparative study of the formulas was conducted. Because the equations does not consider variables such as shape of anchorages and duct, a relation between the bursting forces and the variables has to be analyzed. In this paper, the bursting forces equation was proposed by finite element analysis. As evaluation through comparison of the proposed equation with the previous ones and an experiment, it was figured out that bursting force computed by the proposed equation could be used for design of reinforcement in the anchorage zone.

Effects of tensioning forces on the structural behavior of cable-stayed bridges

  • Lam, Pauline Lin Li;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.457-464
    • /
    • 2022
  • Optimization in distribution of stay cable forces is one of the most difficult aspects in the design of cable-stayed bridges. This article attempts to examine tension force influence on structural behavior of cable-stayed bridges. For the examination, finite element modeling using nonlinear static and nonlinear modal analyses was completed and compared to structural experimental results. Variables analyzed in this parametric study were: 1) Number of stay cables; 2) Tension of the stay cables, and 3) Stay cable pattern - harp and semi-fan patterns. Though the findings from the analysis are limited to the tested models, the study gives insight on the structural behavior of actual cable stayed bridges.

EVALUATION OF NONDESTRUCTIVE TESTS ANALYSIS TO ESTIMATE INPLACE STRENGTH OF CONCRETE

  • Parviz Ghoddousi;Mohsen Tadayon;Pedram H. Mojarad
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.672-680
    • /
    • 2005
  • There are a lot of reasons to use In-place tests. Construction schedules often require that operations such as form removal, post-tensioning, termination of curing, and removal of reshores be carried out as early as possible. To enable these operations to proceed safely as soon as possible requires the use of reliable in-place tests to estimate the in-place strength. In-place test results are not reliable for engineering judgment. These results should be interpreted and correlated to standard compressive strength, based on the test method. In this paper some of these test procedures and their limitations are discussed. In this study we will go on for Rebound number, Pullout, Ultrasonic pulse velocity, and Cast-in-place cylinder methods which are most useful methods in the Asia.

  • PDF

포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동 (Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems)

  • 한상환;기성훈;강현구;조종;이리형
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.595-602
    • /
    • 2006
  • 본 연구의 목적은 중력 하중에 저항하도록 설계된 플랫 플레이트 외부 접합부의 이력 거동을 평가하는 데 있다. 이러한 목적을 위하여 2/3의 크기가 조정된 PT 슬래브-기둥 외부 접합부 2개와 RC 슬래브-기둥 외부 접합부 1개를 대상으로 실험적 연구를 수행하였다. 여기서 각각의 PT 실험체는 서로 다른 강선 배치 형태를 띄고 있다. 중력 하중은 동일하게 설정하였고, 지속적인 정적 하중 하에서 유사 정적 횡하중을 적용하였다. 한편 모든 실험체는 ACI 318-05과 ACI 352.1R-89에 근거하여 기둥 폭 내에 하부 철근을 배근 하였다. 또한 PT 외부 접합부의 이력 거동에 대한 일반적인 결론을 얻기 위하여 기존 연구자들의 실험 결과와 함께 비교하였다. 이번 연구를 통하여 강선의 배치는 PT 접합부의 이력 거동을 결정하는 중요한 변수임을 확인하였다. 즉 횡변형 성능, 에너지 소산 능력, 파괴 메커니즘, 그리고 연성 능력이 강선의 배치에 따라 다르게 나타났다. 또한 ACI 352.1R-89에서 구조적 일체성을 위해 제공된 하부 철근의 양은 모멘트 역전에 의해 발생된 정모멘트를 저항하는데 있어서도 적절하다는 것이 밝혀졌다. 또한 실험체의 전단 강도는 강선의 포스트 텐션에 의한 평균 콘크리트 압축 응력($f_{pc}$)의 효과가 고려된 식이 그렇지 않은 식보다 전단 강도를 정확히 예측하는 것으로 나타났다.

고강도 전단보강철근을 사용한 포스트텐션 프리스트레스트 콘크리트 보의 전단거동 평가 (Shear Behavior of Post-tensioning PSC Beams with High Strength Shear Reinforcement)

  • 전병구;이재만;임혜선;이정윤
    • 콘크리트학회논문집
    • /
    • 제28권1호
    • /
    • pp.33-40
    • /
    • 2016
  • 현재, 국내외 전단 설계기준에서 RC 및 PSC 부재의 전단보강철근의 최대항복강도를 제한하고 있다. 이는 고강도 전단보강철근을 사용한 RC 부재의 전단거동평가에 대한 선행 연구들에 근거한 것이다. 이에 비해 고강도 전단보강철근을 사용한 PSC 부재의 전단거동평가에 대한 연구는 미흡하며, PSC 부재는 긴장력에 의한 축압축력에 의해 RC 와는 다른 전단거동을 나타내므로 국내 기준에 대한 검증이 필요하다. 또한 이러한 제한으로 인해 고강도 철근을 PSC 부재에 적용할 경우 강도의 추가적인 상승분을 내력에 포함시킬 수 없어 고강도 재료의 사용을 저해시키는 요인으로 작용한다. 본 연구에서는 총 8개의 고강도 재료를 사용한 포스트텐션 PSC 보 전단실험을 실시하여 KCI-12 기준 및 ACI 318-14 기준의 항복강도 및 사인장균열의 폭을 검토하였다. ACI 318-14에서 요구하는 전단보강철근의 항복강도 제한값(420 MPa) 이상인 모든 PSC 실험체의 전단보강철근이 항복한 이후에 최대 내력에 도달하였으며, 실험 전단내력 또한 KCI-12 기준식의 전단강도 이상인 것으로 나타났다. 사용성 측면에서도 고강도 전단보강철근을 사용한 모든 실험체가 ACI 224위원회의 허용 균열폭(0.41 mm)을 초과하지 않았다. 본 연구의 실험결과에 근거하여 KCI-12 기준에서 제한하는 전단보강철근의 항복강도는 PSC 부재에 대해서 전단내력 및 균열의 사용성 측면을 모두 만족하는 것으로 판단되며 ACI 318-14의 전단보강철근 제한 기준은 다소 안전측에 속하는 것으로 사료된다.

강연선의 국부적 손상에 따른 응력 회복길이 분석 연구 (Study on Stress Recovery Length of 7-Wire Strand due to Local Damage)

  • 서동우;김병철;정규산;나원기;박기태
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.150-156
    • /
    • 2017
  • 본 연구는 PSC(Post Tensioned Concrete) 교량 및 사장교(Cable Stayed Bridge) 등에 많이 적용되는 강연선의 국부적 손상에 따른 응력 회복길이를 분석하였다. 강연선은 PC 강선(Prestressing Strand)을 여러 줄을 꼬은 강재이며, 재료의 특성상 준공후 지속적으로 손상이 발생하며 부식 등이 주요 손상원인이다. 이에 따른 손상에 따른 성능저하가 발생하지만, 구조적인 특성상 케이블 내부의 손상 정도 및 응력 변화 패턴을 파악하기 어렵다. 교량에 적용된 케이블의 경우 설치 형상에 따라 채수 등에 따라 부식에 취약한 부분이 발생하며, 이로 인해 국부적인 손상이 발생할 수 있다. 본 연구는 교량 Post-Tensioning 또는 케이블 사장재에 주로 적용되는 강연선(7-Wire Strand)의 국부적 손상에 따른 성능저하 경향 및 응력 회복길이를 FEA 해석을 통하여 분석하였다. 향후 본 연구에서 구축하고자 하는 해석모델을 활용하여 PSC 교량 및 사장교 케이블 등의 안전성 평가 및 잔존수명 예측에 활용될 수 있을 것으로 사료된다.