• 제목/요약/키워드: tension control

검색결과 853건 처리시간 0.025초

다중 동흡진기를 이용한 장력구배를 갖는 박판의 진동 제어 (Vibration Control of Membrane with Tension Gradient Using Multiple Dynamic Absorber)

  • 박종현;김성대;김원진
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.595-603
    • /
    • 2005
  • In this work, the multiple dynamic absorber( MDA ) is introduced to reduce several vibration modes of shadow mask simultaneously and its design method is developed from the theory of the simple dynamic absorber. When designing the dynamic absorber, there are three significant design parameters such as mass, damping ratio and tuning frequency. Therefore the sensitivity analysis for those parameters has been executed in order to find out the design criteria of multiple dynamic absorber using the finite element model of shadow mask. The multiple dynamic absorber(MDA) designed by the proposed method is tested theoretically and experimentally to estimate the efficiency of vibration reduction. From the results, it is verified that the method is feasible to apply the system having the multiple nitration modes and more efficient than the thin wire-type damper used commercially to reduce the vibration of shadow mask.

초음파 직물수세기의 구성 및 구동 특성 (Assemblage and Driving Characteristics of a Ultrasonic Fabric Washing Machine)

  • 이춘길;이광수
    • 한국염색가공학회지
    • /
    • 제12권3호
    • /
    • pp.207-217
    • /
    • 2000
  • A new, high-efficiency ultrasonic fabric washing machine was developed to be an energy-efficient washing machine and to enhance fabric washing quality in washing processes of the dyeing and finishing process in the textile industry. This system is composed of ultrasonic wave generator, air blowing nozzle, torque motor for fabric tension control, and enclosed washing bath, multi-tube type exchanger, noiseless heater, air cylinder, expander roller, mangle upper and lower rollers, bend bar, dancer, shower spray nozzle, and solenoid valve, and so on. These elements are synergised for fabric washing. One of the very important principles is the low tension fabric running system. For an efficient washing effect, a counter flow system is also adopted. The new system also adopts the dancer and torque motor to control fabric tension and prevent fabric creasing. Shower spray nozzle, counter flow and overflow apparatus, and air-blowing apparatus are adopted to enhance the fabric washing effect. In this study, peach yoryu, exter, and moss crepe fabrics were washed by the general and ultrasonic washing systems under different conditions respectively. The washing efficiency was affected by the fabric running speed and characteristics of fabrics. Size content after washing increased with increasing the fabric running speed. The values in the general washing system were higher than those of the ultrasonic washing system. The changes of conductivity in the ultrasonic and the cooling bath were affected by the running time under the ultrasonic generating. The values of conductivity decreased as the experimental time passed.

  • PDF

광배근 근피판 거상 후 점진적 긴장 봉합술의 유용성 (The Effectiveness of Progressive Tension Suture at Latissimus Dorsi Muscle Harvest)

  • 문주봉;박정민;권용석;이근철;김석권;조세헌
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.611-616
    • /
    • 2007
  • Purpose: The latissimus dorsi muscle flap is a versatile flap used in a variety of reconstructive procedures. The most common complication of LD muscle flap is donor site seroma, reported to occur in 20 to 79 percent of cases. The formation of dead space under the flap is intimately associated with seroma formation. The authors think that the use of progressive tension suture at closing donor site can decrease the formation of dead space and ultimately reduce the incidence of donor site seroma. Methods: A retrospective review was performed with 38 patients who underwent latissimus dorsi muscle harvest for breast reconstruction from March 2003 to September 2004. Progressive tension sutures were used during donor site closure in 22 patients. This group was compared with controls group(16 patients) who underwent latissimus dorsi muscle harvest without using this technique. Operation time, length of hospital stay, period of drainage, complication, and satisfaction about postoperative scar of donor site were examined. Results: The average length of hospital stay was 10.2 days and 12.7 days, and the mean duration of drainage were 7.3 days and 11.7 days in each progressive suture group and control group. These results were statistically significant (p<0.05). In the 22 patients who underwent progressive tension suture, none had seroma, hematoma or skin necrosis. In control group(16 patients), there happened one seroma formation and one partial skin necrosis. These complications were healed by aspiration of seroma and wound revision. The patients' satisfaction was not statistically significant, but the higher points were given by the patients who underwent progressive tension suture. Conclusion: This technique, progressive tension suture, is an effective method to reduce or eliminate donor site seroma, which is the most common complication associated with latissimus dorsi muscle harvest.

Introduction of Automation and Control Issues for Hot Rolling Mill Processes

  • Lee, Duk-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.175.1-175
    • /
    • 2001
  • This paper handles main automation facilities and important control issues for hot rolling mill processes. Starting from the general procedures of production cycle, detailed tension control applications are handled based on field experiences and published research papers. Nowadays, quality control and delivery time control for products is becoming more and more important as the client demand is tighter than any other period. In this respect, control technology in steel making process takes very important position. Therefore, the objective of this paper is to share control problems with the people in academic field and by doing so, to get new and striking solution for the problems.

  • PDF

대입재수생의 두경부 동통 발생 양상과 인성 특성 (The Craniofacial Pain and the Personality Characteristics in the Students who Failed the College-Entrance Examination)

  • 구자윤;기우천;최재갑
    • Journal of Oral Medicine and Pain
    • /
    • 제23권1호
    • /
    • pp.57-64
    • /
    • 1998
  • Personality characteristics were studied by means of SCL-90-R test, Behavioral problem and pain site was studied Isleep disturbance, irregular eating habit, decreased physical activity, decreased social activity, increased emotional tension) by examination sheets. This study was conducted to examine the mature and extent of psychological difference between the students who failed the college-entrance examination and freshment and to determine whether psychological distress acts as a precipitate for craniocervical pain. 96students who failed the college-entrance examination (examination-failed student) and 86 freshmen were included in this study. The obtained results were as follows : Mean T-score of SCL-90-R primary scaled and global Indies in examination-failed students were significantly higher than the freshmen group. In comparison with examination-failed student group, the prevalence of neck and shoulder pain was significantly higher than the freshmen group. When the study and control group were compared in behavioral problem the study group had not more sound sleep than the control group. The study group had more irregular eating habit than control group. The study group had the lower physical activity than control group. The study group had poor social activity than control group. There was no significant difference in emotional tension.

  • PDF

냉각압연 가공용 자동 형상제어장치의 특성에 관한 연구 (A Study on the Characteristics of Automatic Flatness Control System for Cold Rolling)

  • 김문경;전언찬;김순경
    • 대한기계학회논문집A
    • /
    • 제20권9호
    • /
    • pp.2901-2907
    • /
    • 1996
  • Flatness of cold rolled strip is vital to the quality of the product and productivity of the mill. Therefore, in recent year requirement for flatness control in strip rolling have become increasingly severe. The necessity for more accurate automatic gauge control and automatic flatness control(AFC) has increased by customer's requirement for cold rolled steel sheets with thinner gauge and better flatness quality. In this paper, the performance and functions of AFC system installed on the 4 hi-reversing mill has been investigated under actual conditions. The test results are as follows : The more strip thickness is thick, the smaller the I-value. The I-value is a strain measured by stressometer. Complex distributions of strip tension are controlled to remove not only a quarter buckle but also a simple center wave and edge wave. The defects caused by poor flatness have been drastically decreased. And a proper coolant temperature for work roll cooling system on the AFC system is about $50~55^{\circ}C$.

Turret location impact on global performance of a thruster-assisted turret-moored FPSO

  • Kim, S.W.;Kim, M.H.;Kang, H.Y.
    • Ocean Systems Engineering
    • /
    • 제6권3호
    • /
    • pp.265-287
    • /
    • 2016
  • The change of the global performance of a turret-moored FPSO (Floating Production Storage Offloading) with DP (Dynamic Positioning) control is simulated, analyzed, and compared for two different internal turret location cases; bow and midship. Both collinear and non-collinear 100-yr GOM (Gulf of Mexico) storm environments and three cases (mooring-only, with DP position control, with DP position+heading control) are considered. The horizontal trajectory, 6DOF (degree of freedom) motions, fairlead mooring and riser tension, and fuel consumptions are compared. The PID (Proportional-Integral-Derivative) controller based on LQR (linear quadratic regulator) theory and the thrust-allocation algorithm which is based on the penalty optimization theory are implemented in the fully-coupled time-domain hull-mooring-riser-DP simulation program. Both in collinear and non-collinear 100-yr WWC (wind-wave-current) environments, the advantage of mid-ship turret is demonstrated by the significant reduction in heave at the turret location due to the minimal coupling with pitch mode, which is beneficial to mooring and riser design. However, in the non-collinear WWC environment, the mid-turret case exhibits unfavorable weathervaning characteristics, which can be reduced by employing DP position and heading controls as demonstrated in the present case studies. The present study also reveals the plausible cause of the failure of mid-turret Gryphon Alpha FPSO in milder environment than its survival condition.

실험적 치아 이동시 성견 치주조직의 변화에 대한 면역조직화학적 연구 (IMMUNOHISTOCHEMICAL STUDY ON THE PERIODONTAL TISSUE REACTION DURING EXPERIMENTAL TOOTH MOVEMENT IN THE ADULT DOG)

  • 김미정;양원식
    • 대한치과교정학회지
    • /
    • 제23권1호
    • /
    • pp.89-100
    • /
    • 1993
  • The purpose of this study was to evaluate the effect of orthodontic force on periodontal cellular activity by immunoperoxidase stain of epidermal growth factor, one of the tissue hormone. And supplementarily, to investigate of the changes of periodontal structures, periodontium was stained by H-E, Masson's Trichrome, P. A. S. stain after orthodontic force application. The experimental animals were four young adult dogs of average 8 month old. The fixed orthodontic appliance was cemented on mandibular right 4th premolar and 1st molar of each animal as experimental site. Mandibular left 4th premolar area of the same animal was used as control. The appliance consist of two silver crown soldered with 0.030' tube, $0.018\times0.022'$ S.S. sectional arch wire, and 0.009' open coil spring for manifestating of orthodontic force for bodily tooth movement of mandibular 4th premolar toward mesial direction. Experimental group was sacrificed at 1, 2, 3, 5 weeks from beginning of the experiment, and was investigated immunohistochemically and bistochemically by several staining methods. Findings were as follows: 1. The degree of EGF staining in control group was highest in epithelium of periodontium, and osteoclasts, osteoblasts and fibroblasts around the capillary were stained at higher level in periodontium. Generally, control group shows positive distribution of EGF all around the periodontal area. 2. The degree of EGF staining in control and 5 week group were similar, and did not show the significant different level between tension and pressure side. 3. All of 1, 2, 3 week group showed the same staining degree and distribution of EGF, and the tension side was more positive reaction of EGF stain than the pressure side. 4. The features of collagen fiber and periodontal fiber arrangement observed by H-E, Masson's Trichrome and P. A. S. stain revealed that oblique periodontal fibers were strectched in tension side, compressed in pressure side of all experimental group. Some fiber group in pressure side of 5 week group recovered the regular arrangement along the capillaries.

  • PDF

철근콘크리트 휨부재의 처짐 간접제어를 위한 한계 지간/깊이-비 연구 (Limit Span/Depth Ratio for Indirect Deflection Control in Reinforced Concrete Flexural Members)

  • 최승원;김우
    • 대한토목학회논문집
    • /
    • 제31권1A호
    • /
    • pp.35-41
    • /
    • 2011
  • 콘크리트구조설계기준에서는 일반적으로 처짐을 제어하기 위해 직접처짐제어법과 간접처짐제어법을 제시하고 있다. 이 때 처짐/깊이-비는 허용 처짐량을 초과하지 않도록 제한된다는 점에서 간접처짐제어법이 더 효과적이다. 실제 처짐량은 많은 요소에 의해 영향을 받기 때문에 실제 처짐량을 정확하게 산정하는 것은 어렵다. 이 연구에서는 철근콘크리트 부재의 사용한 계상태에서 처짐량을 직접 계산함으로써 한계 지간/깊이-비를 산정하였다. 이 때 처짐은 재료 모델로부터 산정된 휨곡률을 통해 산정하였다. 해석의 주요 변수는 인장증강효과 모델, 콘크리트 강도, 단면 크기 및 압축 철근의 유무이다. 해석 결과 2차식 형태의 인장증강효과 모델을 사용함으로써 해석의 일관성을 도모할 수 있는 것으로 나타났다. 또한 한계 지간/깊이-비는 단면 크기와 관계없이 재료 강도와 인장 및 압축 철근비에 따라 변화하는 것으로 나타났다.

The Effect of Silver Spike Point Therapy(SSP) that applied to Acupoints on the Blood Flow Rate of Internal Carotid Artery and Pain Relief of Headache Patients

  • Seo, Hyo-Seok;Lee, Yoon-Ho;Yun, Young-Dae;Moon, Ok-Kon;Kim, Ji-Sung;Choi, Suk-Ju;Choi, Yoo-Rim;Zoo, Suk-Bum;Kim, Soon-Hee
    • 국제물리치료학회지
    • /
    • 제2권1호
    • /
    • pp.251-259
    • /
    • 2011
  • The aim of this is to examine the effects of SSP therapy on the internal carotid arteries blood flow of 24 tension type headache patients(study group) and non tension type headache patients(control group), and on the reduction of their headaches, when applied to the acupuncture points. It stimulated the acupuncture point of headache 6 place with the SSP. It measured VAS and the blood flow of the internal carotid arteries with TCD. When the internal carotid arteries blood flow of study group and control group were compared by period, a significant difference was found in the 4th period(p<.05). When the Visual Analog Scale of study group and control group were compared by period, a significant difference was found in the 4th period(p<.05). The comparison of each measurement result of the internal carotid arteries blood flow of the study group found significantly increased. The comparison of each measurement result of the VAS of study group found significantly decreased. With regard to the control group, the VAS significantly decreased. The silver spike point low frequency electrical stimulation treatment, when applied to the acupuncture point, can significantly influence the internal carotid arteries blood flow of headache patients and can significantly reduce their headaches.