• 제목/요약/키워드: tensile resistance

Search Result 1,473, Processing Time 0.023 seconds

Effect Boron and Silicon on Various Properties of Dental Cobalt-Chromium Alloys (치과용 Co-Cr 합금의 제성질에 미치는 Boron과 Silicon의 영향)

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.14 no.1
    • /
    • pp.119-132
    • /
    • 1992
  • This paper aims to investigate the effect of B and Si upon the mechanical properties, microstructure and corrosion resistance of Co-Cr base alloy. Ten groups of alloy ingot ingot with various contents of B and Si were remelted by high frequency electrical induction furnace and cast into tensile specimen of ADA Specification No. 14 Tensile and hardness test were carried out by Amsler and Rockwell hardness tester(R-30N), respectively. The microstructures of specimen were observed by SEM. The results obtained are summarized as follows : 1. As B content is increased, tensile strength, yield strength and Rockwell hardness number(R-30N) are also increased significantly, while the elongation is decreased significantly. 2. As Si contect os increased, no significant chang in tensile strength is noticed, yield strength is slightly decreased, but Rockwell hardness number(R-30N) is moderately in creased, Elongation marks maxium value with 1% Si content while with more than 1% Si it is decreased. 3. As B content is increased corrosion resistance is decreased and is at best with 1.5% B content. Corrosion resistance is increased with the increase of Si content and the alloys with Si over 3.0% showed corrosion resistance. 4. As B content increased, precipitates are increased in number at grain boundaries. The grain size tends to become coarse with the increase of Si content. 5. Co rich-Cr alloy is present through matrix whereas at the grain boundaries Cr base precipitates are primarily formed.

  • PDF

Evaluation on Strength Characteristics of Automobile Steel Sheet by Electrode Resistance Spot Weld (전기저항 점용접한 자동차 강판의 강도특성평가)

  • Yoon, Han-Ki;Hu, Kwan-Do;Ryu, Deok-Seang
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.115-119
    • /
    • 2013
  • The resistance spot welding of high strength steel degrades the weldability because of its high strength with rich chemical composition and coating layer to protect from corrosion. And the weld Expulsion is prone to occur and severely affect the nugget guality when the initial gap between automatic borrowing galvanied steel sheets(SGARC35) and Zn-coateel trip steels(GA580TRIP and GA980 TRIP) exist in resistance spot welding(RSW). RSW is one of the most popular welding processes used to join sheet metals. but weld guality sometimes do creases due to welding condition. in this paper to verity tue weldability using spot welding with the hemispherically concaved electrode, tensile shear strength and cross-tensile strength were measured by a universal test machine. in addition, the nugget size on cross-sectional area of the weld was observed by optical and electron microscopy. As a result, the nugget size of this specimen is increased with increasing welding current and Max load of tensile-shear strength is increased with welding current is increasing.

Monitoring Failure Behaviour of Pultruded CFRP Composites by Electrical Resistance Measurement

  • Mao, Yaqin;Yu, Yunhua;Wu, Dezhen;Yang, Xiaoping
    • Carbon letters
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2004
  • The failure behaviours of unidirectional pultruded carbon fiber reinforced polymer (CFRP) composites were monitored by the electrical resistance measurement during tensile loading, three-point-bending, interlaminar shear loading. The tensile failure behaviour of carbon fiber tows was also investigated by the electrical resistance measurement. Infrared thermography non-destructive evaluation was performed in real time during tensile test of CFRP composites to validate the change of microdamage in the materials. Experiment results demonstrated that the CFRP composites and carbon fiber tows were damaged by different damage mechinsms during tensile loading, for the CFRP composites, mainly being in the forms of matrix damage and the debonding between matrix and fibers, while for the carbon fiber tows, mainly being in the forms of fiber fracture. The correlation between the infrared thermographs and the change in the electrical resistance could be regarded as an evidence of the damage mechanisms of the CFRP composites. During three-point-bending loading, the main damage forms were the simultaneity fracture of matrix and fibers firstly, then matrix cracking and the debonding between matrix and fiber were carried out. This results can be shown in Fig. 9(a) and (b). During interlaminar shear loading, the change in the electrical resistance was related to the damage degree of interlaminar structure. Electrical resistance measurement was more sensitive to the damage behaviour of the CFRP composites than the stress/time curve.

  • PDF

Surface Resistance and Tensile Strength of Polyester Resin by Anti-static Agents (대전방지제에 의한 폴리에스테르 수지의 표면저항과 인장강도 특성)

  • Lee, Jeon-Kyu;Choi, Hwan-Oh;Kim, Eun-Bong;Kim, Si-Young;Ju, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.638-642
    • /
    • 2010
  • In order to develope anti - static polyester resin which may be employed to dangerous circumstance with high organic vapor content, the effect of anti - static agents on the surface resistance and tensile strength of polyester resin were studied. Three organic anti - static agents and a conductive carbon black were adapted and used separately and together. The effects of anti - static agents, their contents, and synergic effect of anti - static agents were experimentally examined. Surface resistance and tensile strength of the polyester resin were decreased with the content of anti - static agents, and polyester resin with low surface resistance and relatively high tensile strength could be prepared by synergic effect of organic anti - static agent and carbon black.

Effect of Al2Ca on Oxidation Resistance and Tensile Property of Al-5Mg Alloy (Al-5Mg 합금의 내산화성 및 인장특성에 미치는 Al2Ca의 영향)

  • Ha, Seong-Ho;Yoon, Young-Ok;Kim, Shae K.
    • Journal of Korea Foundry Society
    • /
    • v.34 no.6
    • /
    • pp.194-199
    • /
    • 2014
  • The effect of $Al_2Ca$ on the oxidation resistance and tensile property of Al-5Mg alloys was investigated. According to the TGA (Thermogravimetric analysis) result at $550^{\circ}C$ after 24hrs, the Al-5Mg alloy showed parabolic behavior with weight gain. On the other hand, there was almost no difference in the weight changes of the $Al_2Ca$ added Al-5Mg alloys during the oxidation. It was thought that the improvement of oxidation resistance in $Al_2Ca$ added Al-5Mg alloys might be due to the formation of a protective oxide layer with CaO and MgO on the surface. The microstructures of the alloys showed grain refinement with an increasing $Al_2Ca$ content. From the tensile test, the yield strength of the alloys were improved with an increasing $Al_2Ca$ content. The 0.07 mass%$Al_2Ca$ added Al-5Mg alloy showed similar elongation and increased strength, simultaneously. It was considered that the addition of $Al_2Ca$, which was superior in the oxidation resistance of Al, reduced the formation of Mg oxides and inclusions during the alloying. This, partly led to the improvement of tensile properties.

Effects of Treatment of Cellulase and Alkali on Physical Properties and Dyeability of Ramie/Man-Made Fiber Mixture Fabrics (셀룰라아제와 알칼리 처리에 의한 저마/인조섬유 교직물의 물성과 염색성 변화)

  • 김순심;최종명
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.5
    • /
    • pp.891-900
    • /
    • 2001
  • The purpose of this study were to evaluate the physical properties and dyeability of cellulase and alkali(NaOH, KOH) treated ramie/man-made fiber mixture fabrics. The mixture fabrics were plain weave made by rayon and polyester fiber as warp yarn, and ramie as weft yarn. The crease resistance, drape, tensile strength, and water absorbancy were measured for test fabrics. The K/S value of dyed fabrics were calculated using color difference meter. Also colorfastness to washing and sunlight of dyed fabrics were evaluated. The results obtained from this study were as follows: Thickness and weight per unit area of alkali treated two mixture fabrics(rayon/ramie, polyester/ramie) increased compared to those of untreated fabrics, but cellulase treated fabrics did not changed a little. And alkali treated rayon/ramie mixture fabrics showed more change than polyester/ramie mixture fabrics on the thickness and weight. Tensile strength and water absorbancy of cellulase treated fabrics decreased compared to those of untreated, but crease resistance increased. Crease resistance, tensile strength(warp direction), water absorbancy and drape of NaOH treated rayon/ramie mixture fabrics decreased compared to those of untreated, but tensile strength(weft direction) increased. Water absorbancy and drape of NaOH treated polyester/ramie mixture fabrics decreased compared to those of untreated, but crease resistance and tensile strength(weft direction) increased. Tensile strength of KOH treated two mixture fabrics increased compared to that of untreated, but water absorbancy and drape decreased. Total hand of cellulase and alkali treated rayon/ramie mixture fabrics was improved compared to untreated. Dyeability of treated mixture fabrics was increased compared to untreated.

  • PDF

Characteristics of Tensile Strength and Corrosion Resistance of Lead- free Brass Containing 1 wt.% of Bi (1 wt.% Bi 함유 무연황동의 인장강도와 내식특성에 대한 연구)

  • Joo, Y.S.;Lee, S.B.;Kim, S.Y.;Joo, C.S.;Jung, B.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.3
    • /
    • pp.133-139
    • /
    • 2011
  • This study has been investigated for tensile properties with lead-free brass containing 1 wt.% of Bi. And also characteristic of corrosion resistance was analyzed by polarization test. An increase of tempering temperature was found to tend to decrease tensile strength, and percentage of elongation was shown to be the lowest value at $300^{\circ}C$. On the other hand, the elongation was increased with an increase of tempering temperature after $300^{\circ}C$. The change of mechanical properties was closely related with the content and shape of acicular Witmanst$\ddot{a}$tten ${\alpha}$ formed at the interface of ${\beta}$ phase as well as in ${\beta}$ phase. Tensile strength had a tendency to be decreased with an increase of test temperature. The elongation was shown to be the lowest value at around $300^{\circ}C$, while it began to increase as test temperature rose after $300^{\circ}C$. It might be speculated that the reason that elongation was decreased was found to form bismuth film at the interface of ${\alpha}/{\beta}$ phase leading to be easily brittle when loaded by tensile stress. The lead-free brass containing 1 wt.% of Bi had similar characteristic of corrosion resistance with a free-cutting brass with 3.4 wt. % of Pb in spite of higher fraction of ${\beta}$ phase.

Nonlinear Tensile Behavior Analysis of Torque-controlled Expansion Anchors Using Finite Element Analysis (유한요소해석을 활용한 비틀림 제어 확장앵커의 비선형 인장거동 특성 분석)

  • Bang, Jin Soo;Youn, Ilro;Kwon, Yangsu;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.91-99
    • /
    • 2020
  • Post-installed anchors were widely used due to its workable benefits. Regarding the resistance performance of anchors, the critical edge distance is presented to minimize the impact of concrete splitting. In the case of actual anchors, however, it is difficult to obtain the ideal edge distance. The purpose of this study is to identify resistance performance and behavior characteristics that contain complex elements such as concrete crack occurring under tensile load. Tensile tests were conducted based on the standard method. Failure shape and the resistance characteristics that do not have the critical edge distance were derived by tensile load. Parametric analysis according to the boundary condition was performed to simulate the actual tensile behavior, through a nonlinear finite element model based on the specimen. Consequently therefore, verifying analysis results the resistance mechanism can be applied through boundary conditions.

CORRELATION BETWEEN THE TENSILE STRENGTH AND CORROSION BEHAVIOR OF HEAT TREATED ZR-1.0NB ALLOY

  • Kim, Tae-Kyu;Choi, Pyung-Sik;Yang, Sung-Ki;Lee, Chong-Tak;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.505-510
    • /
    • 2008
  • The correlation between the tensile strength and corrosion behavior of Zr-1.0wt%Nb alloy heat treated at $480^{\circ}C$ for up to 32 hours was evaluated. The tensile strength at $400^{\circ}C$ was continuously reduced with an increasing heat treatment time, mainly due to a grain growth and a decreased area fraction of the precipitates. However, the corrosion resistance in an aqueous ammonia solution at $360^{\circ}C$ was enhanced, mainly due to the formation of $\beta$-Nb precipitates. It is thus concluded that a longer heat treatment time provides a better corrosion resistance while degrading the tensile strength.

A Study on Property Change with Mixing Ratio in NBR/PVC Composites

  • Li, Xiang Xu;Jeong, Hyung Seok;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • v.53 no.2
    • /
    • pp.48-51
    • /
    • 2018
  • 10, 20, 30, and 40% of polyvinyl chloride (PVC) were added to nitrile butadiene rubber (NBR) to modify the latter. The NBR/PVC composites containing pure NBR were synthesized to investigate properties, such as crosslinking density, hardness, tensile strength, abrasion resistance, heat resistance, solvent resistance, and filler dispersion. The experimental result revealed a decrease in crosslinking density and heat resistance with increase in the PVC content. In contrast, addition of PVC to NBR resulted in enhancement of hardness, tensile strength, solvent resistance, and filler dispersion.