• Title/Summary/Keyword: tensile Strength

Search Result 7,711, Processing Time 0.029 seconds

Fatigue Strength Evaluation of Adhesive Bonded and Mechanical Pressed Joints of Cold Rolled Steel Sheet (냉간압연강판 접착 및 기계적 프레스 접합부의 피로강도 평가)

  • Kim, Ho-Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • The tensile and fatigue experiments were conducted with tensile-shear specimens for investigating the strength of adhesive bonded and mechanical press joints of SPCC steel sheet used in the field of the automobile industry. The optimal punch press force was evaluated 50kN for combining epoxy adhesive bonding and mechanical press joining with a diameter of 8.3mm using SPCC sheet with a thickness of 0.8mm. The combining epoxy adhesive bonding and mechanical press joining exhibits the maximum tensile force of 750N. The fatigue strengths of the combination of adhesive bond and mechanical press joint and pure adhesive joint were evaluated 370N and 320N at 106cycles, respectively. These values correspond to 22% and 20% of their maximum tensile forces, respectively. However, the fatigue strength of the combination of adhesive bond and mechanical press joining was much lower than that of pure mechanical press joining.

Numerical Simulation of Tensile Strength Test by Ring-type Specimen (링 시험편에 의한 인장강도시험의 수치해석)

  • 진연호;양형식;박철환
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.63-66
    • /
    • 2000
  • Stress variation due to size variation and the eccentricity of ring type tensile specimen was analyzed by FLAC program. To get the stable tensile strength the ratio of inner to outer ring diameter should be within a certain range. Diameter ratio of 0.3 was suggested to be adequate. It seemed to be difficult to determine the tensile strength because of stress distortion if eccentricity exceeded home limit. To limit the error in 10%, lateral and axial eccentricity was analyzed to be in the limits of 3% and 10%, respectively.

  • PDF

Numerical Simulation of Tensile Strength Test by Ring-type Specimen (링 시험편에 의한 인장강도시험의 수치해석)

  • 진연호;양형식;박철환
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.316-319
    • /
    • 2000
  • Stress variation due to size variation and the eccentricity of ring type tensile specimen was analyzed by FLAC program. To get the stable tensile strength the ratio of inner to outer ring diameter should be within a certain range. Diameter ratio of 0.3 was suggested to be adequate. It seemed to be difficult to determine the tensile strength because of stress distortion if eccentricity exceeded some limit. To limit the error in 10%, lateral and axial eccentricity was analyzed to be in the limits of 3% and 10%, respectively.

  • PDF

Mechanical strengths of self compacting concrete containing sawdust-ash and naphthalene sulfonate

  • Elinwa, Augustine U.;Mamuda, Mamuda;Ahmed, M.
    • Advances in concrete construction
    • /
    • v.2 no.4
    • /
    • pp.301-308
    • /
    • 2014
  • The present research work is on the effect of sawdust ash (SDA) on the mechanical strengths of self compacting concrete (SCC) using naphthalene sulfonate (NS) as a plasticizer. Experiments on compressive, flexural and splitting tensile strengths are conducted and the data analyzed using the Minitab 15 software. The results showed that SDA can defer the reaction of cement hydration and prolong the setting times of cement paste. This was very much pronounced on the flexural and splitting tensile strengths at 90 days of curing which are 36 % and 33 % higher than the control strengths, respectively. The study has proposed strength relations of mortar compressive strength with the flexural and splitting tensile strengths and these are, 5 and 7 times respectively. The flexural strength is 1.5 times that of the splitting tensile. Finally, linear models were developed on these relationships.

Statistical Properties for Tensile strength of Composite Materials Patched with AFRP on 2024-T3 Aluminum Alloy plate (Al 2024-T3 판에 AFRP를 접착한 복합재료의 인장강도에 대한 통계적 특성)

  • Yun, Han-Gi;An, Won-Gi;Heo, Seon-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.7 s.178
    • /
    • pp.1810-1816
    • /
    • 2000
  • A hybrid composite APAL(Aramid Patched Aluminum alloy) , consisting of Al 2024-T3 aluminum alloy plate sandwiched between two aramid/epoxy laminates, was developed. The characteristics of tensile s trength were investigated and statistical properties of tensile strength were studied in terms of Weibull distribution probability with number of AFRP laminates. The tensile strength of APAL was inproportional to number of AFRP laminates and followed the two-parametic Weibull distribution.

Failure analyses of friction welded Al/Cu joints (Al/Cu 마찰용접부의 파단분석)

  • 박재현;권영각;장래웅
    • Journal of Welding and Joining
    • /
    • v.12 no.1
    • /
    • pp.80-93
    • /
    • 1994
  • The microstructure and fractography of the friction welded joint of Al to Cu have been investigated in order to understand the formation of intermetallic compounds and their effects on the failure in tensile test of the joint. The variation of welding pressure did not affect significantly the tensile strength of joint. However, the tensile strength of joint decreaed as welding time increased. The thickness of reaction layers of welded joints was several micro-meters and mainly composed of intermetallic compounds of $CuAl_2$, $Cu_9Al_4$ and Al+$CuAl_2$. The thickness of $CuAl_2$, $Cu_9Al_4$ was increased with welding time. However, $CuAl_2$ was gradually changed to $Cu_9Al_4$ which caused the decrease of tensile strength . Even though the morphology of fractured surfaces depended upon the welding time, the failure occurred along $CuAl_2$ intermetallic compound itself or between $CuAl_2$ and $Cu_9Al_4$ in most cases.

  • PDF

Analysis of Tensile Strength Characteristics of ACSR due to White Rust (백화현상에 따른 ACSR 송선선로의 인장강도 특성 분석)

  • Park, Dae Keun;Ahn, Jung Hwan;Kwak, Minjun;Jung, Mihee;Choi, Cheol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2022
  • In this study, a tensile test, one of the mechanical tests, was performed with the collected natural aging ACSR. In order to be used as basic data for predicting the replacement cycle of ACSR, the tensile strength with the normal cables was compared for cables which was caused white rust due to exposure of the hard-drawn aluminum wire surface. Among the ACSR wires collected from various regions, white rust was found on the surface of the small wire, and by checking the tensile strength of them, we would like to suggest the criteria for the ACSR replacement cycle, focusing on changes in mechanical properties.

A STUDY ON TENSILE STRENGTH AND PHYSICAL ALTERATION OF THERMALLY RECYCLED METAL BRACKETS (열처리한 재생금속 bracket의 인장강도와 물리적 변화에 관한 연구)

  • Park, Chang-Gee
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.261-269
    • /
    • 1985
  • The purpose of this study was to measure and compare tensile strength for 3 types of new direct-bond brackets and the same brackets after recycling and to evaluate recycled brackets to determine the extent of physical alteration after recycling. Three types of new direct-bond brackets were bonded to recently extracted human premolar teeth and the tensile strength was measured by Universal Testing Machine. The brackets were recycled by thermal process and the tensile test was repeated. To determine the extent of physical alteration after recycling, the slot width and the hardness of metal brackets were measured and to analyze the microstructure of the brackets, photographs of the bracket microstructure were taken. Following results were obtained: 1. The tensile strength of recycled brackets was lower than that of new brackets, but there was no statistically significant difference. (p>0.05) 2. In the new and recycled brackets, the tensile strength of mini-mesh base bracket was statistically higher than that of conturlok base bracket, $(p\leq0.05)$ but there was no statistically significant difference between production of other companies. (p>0.05) 3. The slot width of metal bracket was enlarged from 0.459mm to 0.469mm as a result of the recycling process. (p>0.005) 4. As temperature was increased in thermal treatment, the grains of bracket metal gradually became coarser and the hardness was decreased.

  • PDF

Analysis of RC beam with unbonded or exposed tensile steel reinforcements and defective stirrup anchorages for shear strength

  • Wang, Xiao-Hui;Liu, Xi-La
    • Computers and Concrete
    • /
    • v.10 no.1
    • /
    • pp.59-78
    • /
    • 2012
  • Although the effect of corrosion of reinforcing bar on the shear behavior of the reinforced concrete (RC) beam had been simulated by tests of the beam with unbonded, half-exposed or whole-exposed tensile steel reinforcements as well as defective stirrup anchorages, theoretical methods to accurately predict remaining capacity of this kind of RC beams, especially shear capacity, are still lacking. Considering the possible position of the critical inclined crack, the actual pattern of strains in the concrete body within the partial length and the proposed compatibility condition of deformations of the RC beam, shear strength of the RC beam with unbonded or exposed tensile steel reinforcements and/or defective stirrup anchorages is predicted. Comparison between the model's predictions with the experimental results published in the literature shows the practicability of the proposed model. Influence of the length of unbonded or exposed tensile steel reinforcements and the percentage of stirrups lacked end anchorages on the shear strength of the RC beam is discussed. It is concluded that, the shear strength of the RC beam with unbonded or exposed tensile steel reinforcements and/or defective stirrup anchorages is greatly influenced by the length of unbonded or exposed tensile steel reinforcements and the percentage of stirrups lacked end anchorages, this influence can be adverse, insignificant or even favourable, dependent on the given parameters of the corresponding normal bonded RC beam.

Analysis of Tensile Strength Changes by Outdoor Exposure of Scaffolding PP Fiber Rope (달비계용 PP섬유로프의 야외노출에 따른 인장강도 변화 분석)

  • Sung-Yun Kang;Kihyo Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.3
    • /
    • pp.31-36
    • /
    • 2023
  • The use of hanging scaffolding for exterior wall painting and cleaning in building construction and maintenance carries the inherent risk of fall accidents. While periodic rope replacement is crucial for preventing accidents resulting from rope breakage, current regulations lack specificity in determining appropriate disposal period for fiber ropes. This study analyzed the tensile strength of the most commonly used PP fiber ropes with different diameters (16 mm, 20 mm) in the domestic construction industry. Additionally, the effect of outdoor exposure was examined by measuring the tensile strength of new ropes and ropes exposing to outdoor conditions for 30 days and 90 days. The results showed that the new ropes and those exposed to outdoor for 30 days met the KS (Korean Standards) criteria for tensile strength. However, a significant decrease in tensile strength was observed in ropes exposed to outdoor for 90 days compared to both the new ropes and those exposed for 30 days. Furthermore, the ropes exposed for 90 days did not meet the KS criteria. These findings indicate the degradation of PP fiber ropes due to UV (Ultra Violet) radiation, highlighting the importance of considering this factor when determining the replacement period for fiber ropes used in scaffolding work.