• 제목/요약/키워드: temperature type

Search Result 8,999, Processing Time 0.038 seconds

A Study on the Three-Dimensional Steady State Temperature Distributions and BOR Calculation Program Development for the Membrane Type LNG Carrier (Membrane Type LNG선의 3차원 정상상태 온도분포 및 BOR 계산 프로그램 개발에 관한 연구)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.140-149
    • /
    • 1999
  • This study is on the development of the computer program that calculates a 3-D hull temperadistribution and analyzes BOR(Boil off rate) to be important to the heat design of a membrane type LNG carrier. The quarter of a tank is taken as an calculation model. And the thermal conductivity of insulation is assumed to be the function of a temperature. In the present steady state calculation, the temperature of LNG in a cargo tank is assumed to be -$162^{\circ}C$ and the air temperature of a cofferdam, to be +$5^{\circ}C$. The lowest air temperature in compartments is calculated as $21.39^{\circ}C$ under the USCG condition ($T_{air}=-18^{\circ}C,\;T_{sw}=O^{\circ}C)$ and B.O.R value is O.0977%/day under the maximum boil-off condition, IMO IGC ($T_{air}=45^{\circ}C,\;T_{sw}=32^{\circ}C$), which satisfies the requirement by KOGAS. The calculated temperature distribution over tank panels at each condition is maximum 3% less than GTT's results. From the results of this study, it can be concluded that the present design of LNG cargo tank satisfies the requirement by KOGAS.

  • PDF

The Study on Electrical and Optical Properties in LED Module by the Environment Temperature (LED Module의 주위 온도에 따른 전기적 광학적 특성 연구)

  • Lee, Seung-Min;Lee, Seong-Jin;Yang, Jong-Kyung;Yim, Youn-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.222-223
    • /
    • 2006
  • In this paper, we manufactured high flux LED module with Through Hole type. and we measured electrical, optical and thermal properties by driving type. LED module was composed with 8*8 arrangement form by using the glass epoxy PCB. Also, we measured the most suitable driving type with static voltage driving type and static current driving type. As a result, the LED Module of static voltage driving type showed high luminance characteristic than the static current driving type by suppling enough bias. However, the static current driving type showed more stable driving properties because of fast decreasing properties about brightness by increasing the surrounding temperature in the static voltage driving type. Also, due to Quantum confined Stark effect from piezoelectric field, the wavelength of bule peak shifted to long wavelength direction by increasing the surrounding temperature in the static voltage driving type.

  • PDF

Growth and Yield of Barley as affected by Accumulated Temperature (보리 생육기간중 적산온도가 생육 및 수량에 미치는 영향)

  • 구본철;이춘우;이춘기;김재철;박문웅
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.6
    • /
    • pp.468-472
    • /
    • 2001
  • In order to know the relationship between the accumulated temperature distribution and barley growth characteristics, average, early and late heading years were analyzed. Among 24 year's crop situation test 1976, 1979, 1989, 1990, 1998 were sorted to early heading years and 1977, 1980, 1984, 1996 to late heading years. About $650^{\circ}C$ of accumulated temperature from October to December was enough to get average year's heading date in barley. While 62$0^{\circ}C$ of accumulated temperature were not enough for average heading, 67$0^{\circ}C$ of accumulated temperature accelerated barley heading. 78$0^{\circ}C$ of accumulated temperature from October to February, were enough to get average year's heading date in barley. while $650^{\circ}C$ of accumulated temperature were not enough to, 78$0^{\circ}C$ of accumulated temperature accelerated barley heading. Temperature pattern types in early heading years were distinguished by three types : high temperature type before winter(I), high temperature type in winter-regrowth stage(II), high temperature type in tillering stage(III). On the other hands, temperature pattern types in late heading years were divided to two types : low temperature type in winter-regrowth stage(I), low temperature type in tillering stage(II). Barley heading was mainly influenced by temperature before winter and winter-regrowth stage. Yields of early heading years were higher than that of late heading years and yield was heavily influenced by the number of spikes per square meter.

  • PDF

Needle Type of Hybrid Temperature Probe for Both Diagnosis and Treatment of Musculoskeletal Pain Syndrome (근골격계 통증질환의 진단과 치료를 위한 주사바늘형 복합온도 프로브의 개발)

  • Nam, Sung-Ki;Kim, Hyung-Il;Byun, Chang-Ho;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.4
    • /
    • pp.359-364
    • /
    • 2014
  • This paper describes the development of needle type probe that measures temperature and injects medicine for both diagnosis and treatment of musculoskeletal pain syndrome (MPS). The size of trigger points is from several micrometers to millimeter. Therefore, it is required to develop a medical device that is capable of not only finding the trigger points by temperature measurement, but also injecting medicine at the exact location for treatment. To challenge these difficulties, thermocouple was fabricated on the surface of a needle using metal deposition process. Special type of stainless-constantan thermocouple was achieved from the stainless body of a needle itself and deposited constantan metal film. In particular, parylene coating enables to limit the temperature sensitive area to the end of the needle tip. Fabricated needle type probe produces $3.25mV/^{\circ}C$ of thermoelectric sensitivity and compared its performance with commercial T-type thermocouple in animal muscle sample.

Greenhouse environment analysis -Distributions and Variations of Temperature , Relative humidity Illumination , Carbon dioxide and Wind Velocity-

  • Kim, Y.B;Park, J.C.;Song, H.K.;Paek, Y.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.478-486
    • /
    • 1993
  • For satisfactory greenhouse culture, environmental factors must be kept in proper conditions. Therefore, it is important to know relations between environmental conditions and greenhouse systems. In this study, the environment variations and distributions in different types of greenhouses were measured and analyzed. The elements of environment analyzed were temperature , relative humidity, illumination, carbon dioxide and wind velocity. The analyzed greenhouse types were three different types. One of them, A type, was propagation model type by government and the other one, B type, was multiple continuous arches type which was made by farmers himself. The last one, C type, was single arch type which has no environment control system without manual temperature keeping method. The results of this study can be used for reasonable greenhouse environments managements and control.

  • PDF

Studies on Synthesis of X-type Zeolite from the Natural Mordenite (천연 Mordenite로부터 X-형 제올라이트 합성에 관한 연구)

  • 이미재;조재훈;허혜경;최병현
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.12
    • /
    • pp.1570-1576
    • /
    • 1994
  • Effect of Na2O/SiO2 molar ratio, calcining temperature and addition of NaCl were investigated on the hydrothermal formation of X-type zeolite from the natural mordenite, which is a kind of rock deposited abundantly in kuryong po. Pulverized mordenite was first mixed with NaOH or NaOH-NaCl solution, and crystallized under hydrothermal condition at 90~10$0^{\circ}C$ for 10 hrs. Optimum condition for synthesis of the X-type zeolite were \circled1 the ratio Na2O/SiO2, NaCl/Al2O3 and H2O/Na2O:0.68, 11.4 and 40, respectively, \circled2 calcining temperature of starting materials: 90$0^{\circ}C$, \circled3 aging time: 48 hrs. and \circled4 crystallization temperature: 10$0^{\circ}C$. The yield of X-type zeolite under the optimum condition was about 55~60%, and the major crystallized X-type zeolite was faujasite phase. Zeolite of then type X was crystallized when NaCl was added to treating solution with in the limit 14.25 of NaCl/Al2O3 molar ratio. As the calcination temperature (from 50$0^{\circ}C$ to 95$0^{\circ}C$) of starting materials increases, yield of zeolite x increase.

  • PDF

Analysis of Surface Temperature on Urban Green Space Using Unmanned Aerial Vehicle Images - A Case of Sorasan Mt. Nature Garden, Iksan, South Korea - (무인항공 영상을 활용한 도심녹지 표면온도 특성 분석 - 익산 소라산 자연마당을 대상으로 -)

  • CHOI, Tae-Young;MOON, Ho-Gyeong;CHA, Jae-Gyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.90-103
    • /
    • 2017
  • This study analyzed the surface temperature characteristics of urban green spaces under high summer temperatures to clarify the functions of green spaces in reducing urban temperatures. We obtained accurate surface temperature data using highresolution unmanned aerial vehicle images of the survey site, which was an isolated green space in the city. We analyzed differences in the surface temperature by land cover type, vegetation type, species type, and the relationship between surface temperature and vegetation volume. Based on the results, among the land cover types, wetlands and forests had low temperatures and paving areas had very high temperatures. Regarding vegetation type, broad-leaved trees had lower temperatures than coniferous trees in forests. However, in planted areas, coniferous trees had lower temperatures than broad-leaved trees. The temperature of long grass was higher than that of short grass, which suggested that the volume of grass affected the temperature. Regarding forest species type, the temperature of broad-leaved Robinia pseudoacacia forest and mixed broad-leaved forest was lower than coniferous Pinus densiflora forest. There was a slight difference in temperature between R. pseudoacacia forest and mixed broad-leaved forest. The analysis of the relationship between vegetation volume and temperature by forest species type indicated a negative correlation, where the temperature decreased with increasing vegetation volume, similar to the results of previous studies. However, we found a weak positive correlation in R. pseudoacacia forest; therefore, an increase in volume may not reduce the surface temperature depending on the dominant species.

Distribution Pattern of Principal Species in the Mantle Community (임연군락의 주요종 분포양식)

  • Jung, Yong-Kyoo;Jong-Won Kim
    • The Korean Journal of Ecology
    • /
    • v.17 no.4
    • /
    • pp.513-521
    • /
    • 1994
  • Distribution patern of 30 species that are occurring predominantly in the mantle communities (Mantelgesellschaften) in South Korea was studied. The study was arried out by geographic and bioclimatic analysis on 368 releves obtained from the Zurich-Montpellier School's method, which involves direct analysis on the latitude, altitude, annual mean temperature and the lowest temperature of the site. Rosa multiflora and Pueraria thunbergiana which are regarded as repersentative pioneer species to the mantle community has the highest frequency, 70.1% and 60.3%, respectively. Three distribution patterns were recognized, i.e. northern type, central type and southern type, and each type was characterized by horizontal and altitudinal amplitude. Their concetrate distribution ranges on the annual mean temperature were 8~11℃, 9~12℃ and 10~13℃, respectively. It was recognized that tendencies of overlapping and continuous distribution pattern of the types and species exist. Geographically, the souther limit f the northern type is 35.5。N and the northern limit of the southern type 37.0。N. The central type is located at an coincided with the previous study in which cool-temperate forests were synchorologically indentified into northern/altimontane, certral/montane and southern/submontane type. The subsidiary knowledges from this study will provide practical information on the constructuin of the fence plant community for environmental conservation.

  • PDF

Experimental Study on Heat Exchange Efficiency of Combined Well & Open-Closed Loops Geothermal System (지하수정호와 결합한 복합지열시스템의 열교환 효율에 대한 실험적 연구)

  • Song, Jae-Yong;Lee, Geun-Chun;Park, Namseo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.5
    • /
    • pp.43-50
    • /
    • 2018
  • The temperature of underground water generally remains constant regardless of the season. therefore, it is possible to get plenty of energy if we use characteristics of underground water for both cooling and heating. This study evaluates efficiency of real size coaxial and U-tube type complex geothermal system which is combined with underground water well. This study also evaluates relative efficiency/adaptability through comparison with existing geothermal systems(vertical closed loop system, open loop system(SCW)). The heat exchange capacity of complex geothermal system according to temperature difference between circulating water and underground water shows very high significance by increasing proportionally. The temperature change of underground water according to injection energy, shows very high linear growth aspect as injection thermal volume heightens. As a result of evaluation of heat exchange volume between complex geothermal system and comparative geothermal system, coaxial type has 26.1 times greater efficiency than comparative vertical closed type and 2.8 times greater efficiency than SCW type. U-tube type has 26.5 tims greater efficiency than comparative vertical closed type and 2.8 times greater than SCW type as well. This means complex geothermal system has extremely outstanding performance.

The Characteristics of Air Temperature Distribution by Land-use Type -A case study of around Automatic Weather Station in Seoul- (토지이용 유형에 따른 기온 특성 -서울시 자동기상관측지점 주변을 사례로-)

  • Kwon, Young-Ah;Lee, Hyoun-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.4
    • /
    • pp.281-290
    • /
    • 2003
  • The influence of land-use type on surrounding temperature was studied the relationships between land-use types and the air condition analyzing AWS (Automatic Weather Station) data of Seoul from KMA (Korea Meteorological Administration). The distribution of air temperature by land-use type has been influenced by the different heating and cooling rates. The difference of heating rates depending on the land-use type was largest at 2~3hours after sunrise and the difference of cooling rates was largest from 2hours before sunset to 2hours after sunset with its maximum at sunset. The difference of cooling rates is greatest in a clear and calm weather situation and the large difference in cooling rates between the green areas and built-up area is up to $1.5^{\circ}C/h$. By season, the difference of cooling rates is largest in fall and in turn spring, winter and summer. In a cloudy or rainy day, the difference in heating and cooling rates on land-use type is not distinct but the tendency is similar to a clear day. In all seasons, the rate of difference occurrence of the daily range of temperature between the green areas and built-up area was large, especially fall. In a fall with a clear and calm day, the magnitude of the daily range of temperature between the green areas and built-up area was largest.