• Title/Summary/Keyword: temperature sensors

Search Result 1,992, Processing Time 0.035 seconds

Simultaneous Measurement of Strain and Temperature During and After Cure of Unsymmetric Composite Laminate Using Fiber Optic Sensors (비대칭 복합적층판의 성형시 및 성형후 광섬유 센서를 이용한 변형률 및 온도의 동시 측정)

  • 강동훈;강현규;김대현;방형준;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.244-249
    • /
    • 2001
  • In this paper, we present the simultaneous measurement of the fabricaition strain and temperature during and after cure of unsymmetric composite laminate uising fiber optic sensors. Fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPl) hybrid sensors are used to measure those measurands. The characteristic matrix of sensor is analytically derived and measurements can be done without sensor calibration. A wavelength-swept fiber laser is utilized as a light source. FBG/EFPI sensors are embedded in a graphite/epoxy unsymmetric cross-ply composite laminate at different direction and different location. We perform the real time measurement of fabrication strains and temperatures at two points of the composite laminate during cure process in an autoclave. Also, the thermal strains and temperatures of the fabricated laminate are measured in thermal chamber. Through these experiments, we can provide a basis for the efficient smart processing of composite and know the thermal behavior of unsymmetric cross-ply composite laminate.

  • PDF

Feasibility Study to Actively Compensate Deformations of Composite Structure in a Space Environment

  • Farinelli, Ciro;Kim, Hong-Il;Han, Jae-Hung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.221-228
    • /
    • 2012
  • An active compensation method for the deformation of composite structures using additional controllable metal parts is proposed, and its feasibility is experimentally investigated in a simulated space environment. Composite specimens are tested in a vacuum chamber, which is able to maintain pressure on the order of 10-3 torr and interior temperature in the range of ${\pm}30^{\circ}C$. The displacement-measuring interferometer system, which consists of a heterodyne HeNe laser and an interferometer, is used to measure the displacement of the whole structure. Meanwhile, the strain of the composite part and temperature of both parts are measured by fiber Bragg grating sensors and thermistors, respectively. The displacement of the composite structure is maintained within a tolerance of ${\pm}1{\mu}m$ by controlling the elongation of the metal part, which is bonded to the end of the composite part. Also, the possibility of fiber Bragg grating sensors as control input sensors is successfully demonstrated using a proper corrective factor based on the specimen temperature gradient data.

A Study on the Construction of an Urban Disaster Prevention System based on WSN/GIS

  • Lee, Jeong-Eun;Shin, Seong-Hyun;Hwang, Hyun-Suk;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.12
    • /
    • pp.1671-1678
    • /
    • 2007
  • In these days, Disaster Management Systems have still put emphasis on its recovery more than the prevention of disaster events. However, the countermeasure of restoration has limitations to prevent the caused loss because the disasters often happen and are massive. Therefore, we propose a disaster prevention system for supporting the safe urban. In this paper, we try to construct a real-time monitoring system to prevent disaster events using new technologies such as Wireless Sensor Networks (WSN) and Geographic Information System (GIS). As a prototype to simulate the fire disasters on real-time, we construct gas sensors and temperature sensors. Our system consists of a WSN system to collect data of the gas and temperature sensors and to monitor the situation information. Our contribution is to provide a prototype application to prevent the disasters from the fire by constructing a WSN system with gas and temperature sensors.

  • PDF

Performance Analysis of Self-Alignment in the Temperature Stabilizing State of Inertial Navigation System (관성항법장치 온도 안정화 상태에서의 초기정렬 성능분석)

  • Kim, Cheon-Joong;Lyou, Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.8
    • /
    • pp.796-803
    • /
    • 2011
  • It is called self-alignment or initial alignment that INS(Inertial Navigation System) is aligned using the measurements from the inertial sensors as an accelerometer and a gyroscope and the inserted reference navigation information in the stop state. The main purpose of self-alignment is to obtain the initial attitude of INS. The accuracy of self-alignment is determined by the performance grade of the used inertial sensors, especially horizontal attitude accuracy by the horizontal accelerometer and vertical attitude accuracy by the E-axis gyroscope. Therefore the uncertain errors in the inertial sensors cause the performance of self-alignment to degrade. In this paper, we analyze theoretically and through a simulation how the errors of inertial sensors in the temperature stabilizing state, one of the uncertain errors, affect the accuracy of self-alignment.

Operation result of the Cryogenic and Mechanical Measurement System for KSTAR (KSTAR 저온 및 구조 계측 시스템 운전 결과)

  • Kim, Y.O.;Chu, Y.;Yonekawa, H.;Bang, E.N.;Lee, T.G.;Baek, S.H.;Hong, J.S.;Lee, S.I.;Park, K.R.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.26-30
    • /
    • 2009
  • Korea Superconducting Tokamak Advanced Research(KSTAR) device is composed of 30 superconducting magnets, magnet structure, vacuum vessel, cryostat, current feeder system, and etc. KSTAR device is operated in the cryogenic temperature and high magnetic field. We install about 800 sensors - temperature sensors, stain gages, displacement gages, hall sensors - to monitor the thermal, mechanical, electrical status of KSTAR during operation. As a tremendous numbers of sensors should be installed for monitoring the KSTAR device, the method of effective installation was developed. The sensor test was successfully carried out to check its reliability and its reproduction in the cryogenic temperature. The sensor signal is processed by PXI-based DAQ system and communicated with central control system via machine network and is shown by Operator Interface(OPI) display in the main control room. In order to safely operate the device, any violations of mechanical & superconductive characteristic of the device components were informed to its operation system & operator. If the monitored values exceed the pre-set values, the protective action should be taken against the possible damage. In this paper, the system composition, operation criteria, operation result were presented.

A novel Fabry-Perot fiber optic temperature sensor for early age hydration heat study in Portland cement concrete

  • Zou, Xiaotian;Chao, Alice;Wu, Nan;Tian, Ye;Yu, Tzu-Yang;Wang, Xingwei
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.41-54
    • /
    • 2013
  • Concrete is known as a heterogeneous product which is composed of complex chemical composition and reaction. The development of concrete thermal effect during early age is critical on its future structural health and long term durability. When cement is mixed with water, the exothermic chemical reaction generates hydration heat, which raises the temperature within the concrete. Consequently, cracking may occur if the concrete temperature rises too high or if there is a large temperature difference between the interior and the exterior of concrete structures during early age hydration. This paper describes the contribution of novel Fabry-Perot (FP) fiber optic temperature sensors to investigate the thermal effects of concrete hydration process. Concrete specimens were manufactured under various water-to-cement (w/c) ratios from 0.40 to 0.60. During the first 24 hours of concreting, two FP fiber optic temperature sensors were inserted into concrete specimens with the protection of copper tubing to monitor the surface and core temperature change. The experimental results revealed effects of w/c ratios on surface and core temperature developments during early age hydration, as well as demonstrating that FP fiber optic sensors are capable of capturing temperature variation in the concrete with reliable performance. Temperature profiles are used for calculating the apparent activation energy ($E_a$) and the heat of hydration (H(t)) of concrete, which can help us to better understand cement hydration.

Temperature-Compensative Displacement Sensor based on a Pair of Fiber Bragg Gratings Attached to a Metal Band

  • Kim, Kwang Taek;Kim, Dong Geun
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.82-85
    • /
    • 2018
  • This paper proposes a new temperature-compensative displacement sensor with a pair of fiber Bragg gratings (FBG) attached to the inner and outer surfaces of an elastic metal band. The sensor can be also used as a temperature sensor with high sensitivity. The FBG pair shifted Bragg wavelengths in the same direction according to changes in the temperature. However, because the pressure of the metal band shifted a pair of Bragg wavelengths in the opposite direction, the displacement sensor could compensate for the effect of the temperature change in the proposed FBG pair. Results of the experiments showed that the two FBG displacement sensors responded linearly and symmetrically with respect to the displacement, and the displacement could be obtained using the difference between the two Bragg wavelengths.

Feasibility of the Defrost Control by Photoelectric Technology via Comparison with the Temperature Differential Defrosting Method (온도차 감지 제상법과의 비교를 통한 광센서 제상법의 타당성 검증을 위한 연구)

  • Jeon, Chang-Duk;Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.434-440
    • /
    • 2014
  • Experiments were performed to verify if performance and characteristic curves obtained from the temperature differential defrosting method, where surface temperature is measured to judge defrosting condition, can be reproduced by the photoelectric technology where defrosting condition is judged by photoelectric sensors. The output voltage of a phototransistor and heating capacity, power consumption, and surface temperature of the outdoor heat exchanger are compared. The results showed that the photoelectric sensors can be used as a defrost control device. On-off control timings in temperature differential defrosting method are in good agreement with those predicted by the high and low threshold output voltages of the photoelectric sensor.

Comparison of Temperature Characteristics Between Single and Poly-crystalline Silicon Pressure Sensor (단결정 및 다결정 실리콘 압력센서의 온도특성 비교)

  • Park, Sung-June;Park, Se-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.342-344
    • /
    • 1995
  • Using piezoresistive effects of single-crystal and poly-crystalline silicon, pressure sensors of the same pattern were fabricated for comparison of temperature characteristics. Optimum size and aspect ratio of rectangular sensor diaphragm were calculated by FEM. For polsilicon pressure sensor, polysilicon resistors of Wheatstone bridge were deposited by LPCVD to be used in a wide' temperature range. Polysilicon pressure sensors showed more stable temperature characteristics than single-crysta1 silicon in the range of $-20\sim125[^{\circ}C]$. To get low TCO (Temperature Coefficient of Offset), below $\pm$3 [${\mu}V/V/^{\circ}C$], it is needed for each TCR of piezoresistors to have a deviation within $\pm25[ppm/^{\circ}C]$ less than $\pm500[ppm/^{\circ}C]$ of resistors for polysilicon pressure sensor can result in low TCS(Temperature Coefficient of Sensitivity) of -0.1[%FS/$^{\circ}C$].

  • PDF