• 제목/요약/키워드: temperature prediction model

검색결과 1,361건 처리시간 0.035초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

보성 종합기상탑 자료를 활용한 국지기상 특성 연구 (Study on the Local Weather Characteristics using Observation Data at the Boseong Tall Tower)

  • 황성은;이영태;신승숙;김기훈
    • 한국지구과학회지
    • /
    • 제41권5호
    • /
    • pp.459-468
    • /
    • 2020
  • 본 연구에서는 2016-2017년 봄철(3-5월) 동안 보성 지역에서의 해풍 발생 시 연직 기상 특성을 분석하기 위해, 해풍 발생에 대한 선정 기준을 마련하였다. 이를 위해 지상에서 측정된 강수량, 운량, 풍향과 지상과 해상 기온의 차이, 1km 고도에서의 윈드프로파일러 및 수치모델 자료를 이용한 풍속 값이 사용되었다. 선정 기준에 따라 보성지역에서의 해풍일을 분류하였고, 해풍 발생 시간 및 고도와 풍속의 크기 분석을 통해 해풍의 시공간적 특성을 파악하였다. 해풍의 발생일은 총 183일 중 23일(12%)로서, 보성지역의 경우 봄철 10일 중 최소 1.2일은 해풍이 나타났다. 해풍은 1200 LST부터 1800 LST로 낮 시간에 지상에서부터 700 m 고도까지 주로 발생하였다. 또한, 최대 풍속은 평균 4.9 m s-1로 1600 LST에 40 m 고도에서 나타나, 선행연구보다 비교적 낮은 값을 보였다. 이는 해안지형이 복잡하여 지형 효과에 따른 풍속 감소로 인한 것으로 보인다.

Molecular characterization and docking dynamics simulation prediction of cytosolic OASTL switch cysteine and mimosine expression in Leucaena leucocephala

  • Harun-Ur-Rashid, Md.;Masakazu, Fukuta;Amzad Hossain, Md.;Oku, Hirosuke;Iwasaki, Hironori;Oogai, Shigeki;Anai, Toyoaki
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.36-36
    • /
    • 2017
  • Out of twenty common protein amino acids, there are many kinds of non protein amino acids (NPAAs) that exist as secondary metabolites and exert ecological functions in plants. Mimosine (Mim), one of those NPAAs derived from L. leucocephala acts as an iron chelator and reversely block mammalian cell cycle at G1/S phases. Cysteine (Cys) is decisive for protein and glutathione that acts as an indispensable sulfur grantor for methionine and many other sulfur-containing secondary products. Cys biosynthesis includes consecutive two steps using two enzymes-serine acetyl transferase (SAT) and O-acetylserine (thiol)lyase (OASTL) and appeared in plant cytosol, chloroplast, and mitochondria. In the first step, the acetylation of the ${\beta}$-hydroxyl of L-serine by acetyl-CoA in the existence of SAT and finally, OASTL triggers ${\alpha}$, ${\beta}$-elimination of acetate from OAS and bind $H_2S$ to catalyze the synthesis of Cys. Mimosine synthase, one of the isozymes of the OASTLs, is able to synthesize Mim with 3-hydroxy-4-pyridone (3H4P) instead of $H_2S$ for Cys in the last step. Thus, the aim of this study was to clone and characterize the cytosolic (Cy) OASTL gene from L. leucocephala, express the recombinant OASTL in Escherichia coli, purify it, do enzyme kinetic analysis, perform docking dynamics simulation analysis between the receptor and the ligands and compare its performance between Cys and Mim synthesis. Cy-OASTL was obtained through both directional degenerate primers corresponding to conserved amino acid region among plant Cys synthase family and the purified protein was 34.3KDa. After cleaving the GST-tag, Cy-OASTL was observed to form mimosine with 3H4P and OAS. The optimum Cys and Mim reaction pH and temperature were 7.5 and $40^{\circ}C$, and 8.0 and $35^{\circ}C$ respectively. Michaelis constant (Km) values of OAS from Cys were higher than the OAS from Mim. Inter fragment interaction energy (IFIE) of substrate OAS-Cy-OASTL complex model showed that Lys, Thr81, Thr77 and Gln150 demonstrated higher attraction force for Cys but 3H4P-mimosine synthase-OAS intermediate complex showed that Gly230, Tyr227, Ala231, Gly228 and Gly232 might provide higher attraction energy for the Mim. It may be concluded that Cy-OASTL demonstrates a dual role in biosynthesis both Cys and Mim and extending the knowledge on the biochemical regulatory mechanism of mimosine and cysteine.

  • PDF

일본 서식 외래 담수어종의 서식확률 평가를 위한 통계기법 연구 (Statistical Methods to Evaluate the Occurrence Probability of Exotic Fish in Japan)

  • 한미덕;정욱진
    • 생태와환경
    • /
    • 제44권2호
    • /
    • pp.195-202
    • /
    • 2011
  • 본 연구에서는 일본전국을 연구대상지로 선정하고 대상지에 서식하고 있는 대표 외래어종인 배스와 블루길의 공간적 서식분포 특성을 평가하였다. 또한 GAM, GLM, CTA 등의 세가지 통계 기법을 이용하여 일본전국에서의 해당 어종에 대한 공간적 분포패턴을 예측하였다. 그 결과 배스와 블루길 등의 외래어종은 인구 및 댐 풍의 인위적인 환경인자와 유의한 정의 관계를 보임에 따라 외래어종의 확산에 미치는 인간활동의 부정적인 영향이 확인되었다. 또한 회귀모델을 통한 해당어종의 서식확률 예측을 통한 배스와 블루길의 서식 분포는 각각 GAM (AUC: 0.88, Kappa: 0.42)과 CTA (AUC: 0.92, Kappa: 0.44)에 의해서 가장 정확하게 예측되는 것으로 평가되었고, 가장 유의한 환경인자는 연평균기온으로 나타났다. 따라서 각 생물종별로 서식확률을 추정하고 예측하는데 있어서 적합한 통계모델에 대한 검증은 생물종별로 선행되어야 할 필요가 있을 것으로 판단된다. 비록 본 연구의 연구대상지는 일본이지만 국내의 경우도 최근 들어 어류를 포함한 생물조사가 다수의 조사연구에서 광역적으로 시행되고 있기 때문에 본 연구와 같은 다량자료를 이용한 광역 스케일에서의 생물종의 서식확률 및 출현종수에 대한 연구가 충분히 가능할 것으로 판단된다.

유동층 코팅 처리한 Ascorbic acid의 흡습특성 및 저장기간 예측 (Shelf-life Estimation and Sorption Characteristics of Coated Ascorbic Acid by Fluidized Bed Coating)

  • 박수정;윤광섭
    • 한국식품저장유통학회지
    • /
    • 제15권3호
    • /
    • pp.332-339
    • /
    • 2008
  • 가공이나 저장 중 쉽게 산화하는 특성을 갖는 ascorbic acid의 안정성을 확보하기 위해 Zein-DP와 HPMC-FCC를 코팅제로 유동층 코팅을 실시하여 ascorbic acid의 저장기간을 예측하고자 하였다. 단분자층 수분함량은 BET식보다 GAB식이 높은 유의성을 나타내었으며, 등온흡습곡선은 ascorbic acid 분말을 제외한 유동층 코팅된 분말의 경우 sigmoid 형태를 나타내었다. 등온흡습곡선의 적합도는 Halsey, Caurie, Oswin Kuhn 모델이 높은 적합도를 보였다. 평형상대습도 예측모델식은 시간과 수분활성도를 변수로 하여 모델식을 수립할 수 있었다 유동층 코팅분말한 ascorbic acid의 DPPH 소거능 변화를 품질지표로 하여 온도와 저장기간에 따른 품질변화 특성을 알아본 결과, DPPH 소거능은 온도가 높을수록 더 큰 영향을 받고 저장기간이 길어질수록 감소하는 경향을 나타내었다. 저장말기에서는 ascorbic acid의 소거능이 유동층 코팅한 분말보다 더 빠르게 감소되는 것으로 보아 유동층 코팅으로 품질 변화를 막을수 있음을 확인하였다. 1차 반응속도식에 따라 반응속도상수를 구하여 10, 20, 30, 50 및 $70^{\circ}C$에서의 반응속도상수를 예측한 결과 온도가 높을수록 높은 반응속도상수를 가져 품질변화가 빠르게 진행되는 것을 알 수 있었다. DPPH 소거능이 50%를 유지하는 저장기간을 예측한 결과 Zein-DP로 코팅한 경우 $20^{\circ}C$에서 45.83일, $10^{\circ}C$에서 63.19일이었고, HPMC-FCC로 코팅한 경우 $20^{\circ}C$에서 28.84일, $10^{\circ}C$에서 36.14일로서, 코팅하지 않은 ascorbic acid보다 저장기간이 연장됨을 확인하였으며 Zein-DP로 코팅한 분말의 경우가 저장기간이 가장 연장될 수 있는 것으로 나타났다.

MODIS 적외 자료를 이용한 한반도 지역의 대기 안정도 지수 산출 (Estimating Stability Indices from the MODIS Infrared Measurements over the Korean Peninsula)

  • 박성희;정의석;;손병주
    • 대한원격탐사학회지
    • /
    • 제22권6호
    • /
    • pp.469-483
    • /
    • 2006
  • Terra 위성에 탑재된 MODIS 적외채널의 밝기온도 자료를 이용하여 한반도 지역에 대해 안정도 지수를 산출하는 알고리즘을 개발하였다. 안정도 지수는 정역학 평형 상태하에서 연직 변위에 대한 대기의 안정도로 정의되며, 대류성 폭풍우의 가능성을 나타내는 지수로 사용된다. RDAPS의 온도와 습도 연직분포 자료를 비선형 물리적 방법에 필요한 초기 추정 자료로 사용하여 KI, KO, LI, MB 지수를 산출하였고, RTTOV-7을 이용하여 물리적 복원 방법에 요구되는 긴 계산 시간을 단축하였다. 복사전달 모의를 통해 추정된 밝기온도는 관측값과 잘 일치하는 것으로 나타났다 단기 예보에 대한 유용성을 살펴보기 위해 안정도 지수 산출 알고리즘을 급격히 발달하는 대류성 폭풍우 사례에 적용하였다. RDAPS로부터 계산된 안정도 지수와 NASA에서 산출한 안정도_ 지수에 비해 대류운의 발달이 예상되는 지역을 보다 정확하게 예측하는 것으로 나타났다. 따라서 본 연구에서 개발된 알고리즘을 사용하여 순간 예보와 단기 예보를 향상시킬 수 있을 것으로 판단된다.

태양광 발전소 건설부지 평가 및 선정을 위한 선형회귀분석 기반 태양광 발전량 추정 모델 (Multiple Linear Regression Analysis of PV Power Forecasting for Evaluation and Selection of Suitable PV Sites)

  • 허재;박범수;김병일;한상욱
    • 한국건설관리학회논문집
    • /
    • 제20권6호
    • /
    • pp.126-131
    • /
    • 2019
  • 최근 태양광의 발전 효율성과 경제성이 높은 발전소 부지를 확보하기 위해 특정 지역을 대상으로 태양광 발전량을 정확히 예측하기 위한 연구들이 수행되었다. 하지만 국내의 경우 기존 발전량 데이터가 부족함에 따라 정확한 발전량 추정에 문제가 발생할 수 있으며, 우리나라 기준으로 어떠한 기상조건을 나타내는 변수가 태양광발전에 어느 정도의 영향을 미치는지에 대한 연구가 부족한 실정이다. 따라서 본 연구는 지형 효과를 충분히 고려하여 제작된 태양복사에너지 지도와 미세먼지와 같은 기상조건을 추가하여 태양광 발전량 추정 회귀모델을 제시하고, 추정된 발전량과 실제 발전량을 비교 분석하였다. 그 결과, 습도를 제외한 태양복사에너지, 온도, 풍속, 운량, 강수량, 일조시간, 미세먼지가 발전 효율에 통계적으로 유의미한 영향을 미치는 것으로 나타났으며, 회귀 분석모델을 통해 추정된 발전량과 실제 발전량을 비교 분석하여 RMSE는 48.261(h), nRMSE는 1.592(%), MAPE는 11.696(%), 그리고 는 0.979이 도출되었다. 이러한 결과는 국내 태양광 발전 부지를 평가함에 있어서 고려해야 하는 중요한 기상 조건 등 태양광 발전량 추정 모델을 설계하는데 활용할 수 있으며, 이를 바탕으로 태양광 발전소 건설 부지를 선정함에 있어 중요한 지표인 발전량을 정확히 추정하는데 기여할 것으로 사료된다.

최대 절대값 기반 시계열 데이터 예측 모델 평가 기법 (Estimation Method of Predicted Time Series Data Based on Absolute Maximum Value)

  • 신기훈;김철;남상훈;박성재;유성수
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.103-110
    • /
    • 2018
  • 본 논문에서는 Mean Absolute Percentage Error (이하 MAPE)와 Symmetric Mean Absolute Percentage (이하 sMAPE)의 새로운 접근법을 이용한 시계열 예측 모델의 평가 방법을 소개한다. MAPE, sMAPE에는 다음과 같은 문제점이 있다. 데이터 집합에서 관측 값이 0일 경우 평가할 수 없고, 관측 값이 0에 매우 가깝다면 과도한 평가 값을 측정한다. 관측 값과 예측 값 간에 동일한 오차를 가지더라도 다른 값으로 평가하는 문제도 가지고 있다. 동일한 오류 값이 과대 예측되었는지 아니면 과소 예측되었는지에 따라 다른 평가 값을 측정하거나 관측 값의 부호와 예측 값의 부호가 서로 다르면 그 오차는 평가 값에 반영되지 않는다. 이러한 문제는 Maximum Mean Absolute Percentage Error (이하 mMAPE)에 의해 해결하였다. 우리는 MAPE 평가 방법의 분모에서 관측 값을 사용하는 대신 최대 절대 값을 사용했다. 최대 절대 값이 1보다 작으면 분모를 제거하여 0 값이 정의되지 않은 문제와 미세한 값일 경우 과대 측정되는 문제를 해결하였다. Beijing PM2.5의 온도 데이터와 시뮬레이션 데이터를 통해 mMAPE와 다른 평가 방법들의 결과 값을 비교하였으며, 위의 문제들을 해결할 수 있음을 검증하였다.

역학적 모델과 딥러닝 모델을 융합한 대청호 수온 예측 (Water temperature prediction of Daecheong Reservoir by a process-guided deep learning model)

  • 김성진;박형석;이건호;정세웅
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.88-88
    • /
    • 2021
  • 최근 수자원과 수질관리 분야에 자료기반 머신러닝 모델과 딥러닝 모델의 활용이 급증하고 있다. 그러나 딥러닝 모델은 Blackbox 모델의 특성상 고전적인 질량, 운동량, 에너지 보존법칙을 고려하지 않고, 데이터에 내재된 패턴과 관계를 해석하기 때문에 물리적 법칙을 만족하지 않는 예측결과를 가져올 수 있다. 또한, 딥러닝 모델의 예측 성능은 학습데이터의 양과 변수 선정에 크게 영향을 받는 모델이기 때문에 양질의 데이터가 제공되지 않으면 모델의 bias와 variation이 클 수 있으며 정확도 높은 예측이 어렵다. 최근 이러한 자료기반 모델링 방법의 단점을 보완하기 위해 프로세스 기반 수치모델과 딥러닝 모델을 결합하여 두 모델링 방법의 장점을 활용하는 연구가 활발히 진행되고 있다(Read et al., 2019). Process-Guided Deep Learning (PGDL) 방법은 물리적 법칙을 반영하여 딥러닝 모델을 훈련시킴으로써 순수한 딥러닝 모델의 물리적 법칙 결여성 문제를 해결할 수 있는 대안으로 활용되고 있다. PGDL 모델은 딥러닝 모델에 물리적인 법칙을 해석할 수 있는 추가변수를 도입하며, 딥러닝 모델의 매개변수 최적화 과정에서 Cost 함수에 물리적 법칙을 위반하는 경우 Penalty를 추가하는 알고리즘을 도입하여 물리적 보존법칙을 만족하도록 모델을 훈련시킨다. 본 연구의 목적은 대청호의 수심별 수온을 예측하기 위해 역학적 모델과 딥러닝 모델을 융합한 PGDL 모델을 개발하고 적용성을 평가하는데 있다. 역학적 모델은 2차원 횡방향 평균 수리·수질 모델인 CE-QUAL-W2을 사용하였으며, 대청호를 대상으로 2017년부터 2018년까지 총 2년간 수온과 에너지 수지를 모의하였다. 기상(기온, 이슬점온도, 풍향, 풍속, 운량), 수문(저수위, 유입·유출 유량), 수온자료를 수집하여 CE-QUAL-W2 모델을 구축하고 보정하였으며, 모델은 저수위 변화, 수온의 수심별 시계열 변동 특성을 적절하게 재현하였다. 또한, 동일기간 대청호 수심별 수온 예측을 위한 순환 신경망 모델인 LSTM(Long Short-Term Memory)을 개발하였으며, 종속변수는 수온계 체인을 통해 수집한 수심별 고빈도 수온 자료를 사용하고 독립 변수는 기온, 풍속, 상대습도, 강수량, 단파복사에너지, 장파복사에너지를 사용하였다. LSTM 모델의 매개변수 최적화는 지도학습을 통해 예측값과 실측값의 RMSE가 최소화 되로록 훈련하였다. PGDL 모델은 동일 기간 LSTM 모델과 동일 입력 자료를 사용하여 구축하였으며, 역학적 모델에서 얻은 에너지 수지를 만족하지 않는 경우 Cost Function에 Penalty를 추가하여 물리적 보존법칙을 만족하도록 훈련하고 수심별 수온 예측결과를 비교·분석하였다.

  • PDF

UAV 기반 도시 공간의 열 쾌적성 평가기법 개발 (Development of a UAV-Based Urban Thermal Comfort Assessment Method)

  • 김성현;송봉근;박경훈
    • 한국지리정보학회지
    • /
    • 제27권2호
    • /
    • pp.61-77
    • /
    • 2024
  • 본 연구는 무인항공기(Unmanned Aerial Vehicle, UAV) 기반 데이터를 사용하여 도시 열 쾌적성을 신속하게 진단하는 방법을 개발하는 것을 목표로 수행하였다. 연구 대상지는 경상남도 창원시에 위치한 창원대학교 공과대학 부지 및 용지공원을 대상으로 수행하였으며, 기초자료 구축에는 현장측정 및 UAV를 활용하였다. 세부적으로 현장측정 기반 열 쾌적성 지수 PET, UTCI를 산출하였으며, UAV를 활용하여 식생지수(NDVI), 하늘시계지수(SVF) 및 지표면 온도(LST) 영상을 제작 후 분석에 활용하였다. 연구결과, UAV 기반 예측된 PET와 UTCI는 각 유의수준 1% 이내에서 0.662, 0.721의 높은 상관관계를 보이는 것을 확인하였다. 예측 모델의 설명력은 PET 43.8%, UTCI 52.6%로 도출되었으며, RMSE는 PET 6.32℃, UTCI 3.16℃로 나타나 UAV 기반 열 쾌적성 평가 시 UTCI 지수를 활용하는 것이 더 적합한 것으로 도출되었다. 본 연구에서 개발된 방법은 기존 접근 방식에 비해 상당한 시간 절약 이점을 제공하여 실시간 도시 열 쾌적성 평가 및 완화 계획에 활용될 수 있을 것으로 판단된다.