• Title/Summary/Keyword: temperature inversion

Search Result 300, Processing Time 0.027 seconds

Transient Change of Electrocardiogram in Two Young Women With Salicylate Intoxication - Two Cases Report - (아스피린 중독에 의한 심전도 변화 2례)

  • You Je-Sung;Park Jong-Woo;Choi Young-Hwan;Cho Young-Soon;Cho Kwang-Hyun;Park Jun-Seok;Chung Sung-Pil;Lee Hahn-Shick
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.4 no.1
    • /
    • pp.44-47
    • /
    • 2006
  • Symptoms of aspirin overdose may vary from acid-base disturbance, electrolyte abnormality, non-cardiogenic pulmonary edema, chemical hepatitis, seizure to cardiac toxicity. Cardiac adverse effects from aspirin are uncommon but there are reports of arrhythmia, cardiopulmonary arrest, and myocardial infarction. We report 2 cases of young women with aspirin overdose who exhibited ischemic changes on their ECGs a few hours after the ingestion with spontaneous recovery in a few days. First case, a 29 year old woman, presented to the emergency department 6 hours after ingesting 250 tablets of aspirin (325 mg/T). On examination, the temperature was $36.3^{\circ}C$: blood pressure, 105/72mmHg; Pulse, 111/min and respiratory rate, 24/min. Second case, a 27 year old woman, an hour after ingesting 60 tablets (325mg/T). On examination, the temperature was $36.0^{\circ}C$: blood pressure, 102/72 mmHg; pulse, 89/min and respiratory rate, 25/min. In both cases, ECG after 6 hours of ingestion had sinus tachycardia and developed T wave inversion on the anterior leads in the following ECGs. Their initial serum salicylate levels after 6 hours of ingestion were 71.2 mg/dL and 28.4 mg/dL respectively. These salicylate levels were resolving when these ECGs were observed. The ECG changes resolved in the following days and they were discharged without any further symptoms. Further studies are needed, but for the time being, when dealing with salicylate overdose, transient cardiac depression should be kept in mind to avoid adverse ischemic cardiac events.

  • PDF

The Adsorption and Desorption of $NH_3$ on Rutile $TiO_2(110)-1{\times}1$ Surfaces

  • Kim, Bo-Seong;Li, Zhenjun;Kay, Bruce D.;Dohnalek, Zdenek;Kim, Yu-Gwon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.265-265
    • /
    • 2012
  • The adsorption of molecular $NH_3$ on rutile $TiO_2(110)-1{\times}1$ surfaces was investigated using a temperature-programmed desorption (TPD) technique combined with a molecular beam apparatus. A quantitative investigation into the TPD spectra of $NH_3$ was made for $NH_3$ adsorbed on two kinds of rutile $TiO_2(110)-1{\times}1$ surfaces with the oxygen vacancy ($V_O$) concentration of ~0% (p-$TiO_2(110)$) and ~5% (r-$TiO_2(110)$), respectively. On both surfaces, non-dissociative adsorption of $NH_3$ was inferred from a quantitative analysis on the amount of adsorbed $NH_3$ and those desorbed. With increasing coverage, the monolayer desorption feature shifted from 400 K toward lower temperatures until it saturates at 160 K, suggesting a repulsive nature in the interaction between $NH_3$ molecules. At the very low coverage regime, the desorption features were found to extend up to 430 K and 400 K on p-$TiO_2(110)$ and p-TiO(110), respectively. As a result, the saturation coverage of monolayer of $NH_3$ was higher on the p-$TiO_2(110)$ surface than on the p-TiO(110) by about 10%. The desorption energy ($E_d$) of $NH_3$ obtained by inversion of the Polanyi-Wigner equation indicated that the difference between the $E_d$'s of $NH_3$ (that is, $E_d(on\;p-TiO_2(110)$) - $E_d$(on p-TiO(110)) was 14 kJ/mol at ${\theta}(NH_3)=0$ and decreased to 0 as the coverage approached to a monolayer. The observed adsorption behavior of $NH_3$ was interpreted using an interaction model between $NH_3$ and surface defects on $TiO_2$ such as VO's and $Ti^{3+}$ interstitials.

  • PDF

Effect of Non-ionic Additive on Morphology and Gas Permeation Properties of Polysulfone Hollow Fiber Membrane (비이온계 첨가제에 의한 폴리술폰계 중공사 막의 모폴로지 조절과 기체투과 특성)

  • Lee, Hye Jin;Koh, Mi Jin;Kim, Duek Ju;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.22 no.3
    • /
    • pp.224-233
    • /
    • 2012
  • To improve permeation performance of gas separation membrane, polysulfone hollow fiber membrane was prepared by wet-dry phase inversion method using Triton X-100 as non-ionic additive. And variation of gas permeation behavior by additive was investigated. Various spinning conditions such as air gap, concentration of polymer, dope tank temperature were controlled and these effects were studied. The morphology and gas permeation property of hollow fiber membranes were investigated using scanning electron microscope (SEM) and bubble flow meter respectively. We confirmed that the membranes added with Triton X-100 had a smooth external skin at various air gap length conditions. The macrovoids of these hollow fiber membranes were more developed with increase of air-gap from 4 to 90 cm and that induced higher permeance. The permeance of polysulfone membranes has the higher value at comparatively lower concentration polymer (30 wt% polysulfone) and lower concentration of additive (15 wt% Triton X-100). When temperature in dope tank was controlled, the membranes prepared at $100^{\circ}C$ showed low permeance because of volatilization of additive and solvent.

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

A Case Study of Strong Wind Event over Yeongdong Region on March 18-20, 2020 (2020년 3월 18일-20일 영동지역 강풍 사례 연구)

  • Ahn, Bo-Yeong;Kim, Yoo-Jun;Kim, Baek-Jo;Lee, Yong-Hee
    • Journal of the Korean earth science society
    • /
    • v.42 no.5
    • /
    • pp.479-495
    • /
    • 2021
  • This study investigates the synoptic (patterns of southern highs, northern lows, and lows rapidly developed by tropopause folding), thermodynamic, and kinematic characteristics of a strong wind that occurred in the Yeongdong region of South Korea on March 18-20, 2020. To do so, we analyzed data from an automatic weather station (AWS), weather charts, the European Centre for Medium-range Weather Forecasts (ECMWF) reanalysis, rawinsonde, and windprofiler radars. The daily maximum instantaneous wind speed, exceeding 20 m s-1, was observed at five weather stations during the analysis period. The strongest instantaneous wind speed (27.7 m s-1) appeared in the Daegwallyeong area. According to the analysis of weather charts, along with the arrangement of the north-south low-pressure line, the isobars were moved to the Yeongdong area. It showed a sine wave shape, and a strong wind developed owing to the strong pressure gradient. On March 19, in the northern part of the Korean Peninsula, with a drop in atmospheric pressure of 19 hPa or more within one day, a continuous strong wind was developed by the synoptic structure of the developing polar low. In the adiabatic chart observed in Bukgangneung, the altitude of the inversion layer was located at an altitude of approximately 1-3 km above the mountaintop, along with the maximum wind speed. We confirmed that this is consistent with the results of the vertical wind field analysis of the rawinsonde and windprofiler data. In particular, based on the thermodynamic and kinematic vertical analyses, we suggest that strong winds due to the vertical gradient of potential temperature in the lower layer and the development of potential vorticity due to tropopause folding play a significant role in the occurrence of strong winds in the Yeongdong region.

The Limnological Survey of a Coastal Lagoon in Korea (2): Lake Hyangho (동해안 석호의 육수학적 조사(2): 향호)

  • Kwon, Sang-Yong;Lee, Jae-Il;Kim, Dong-Jin;Kim, Bom-Chul;Heo, Woo-Myung
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.1-11
    • /
    • 2004
  • The limnological characteristics of a coastal lagoon were studied in Lake Hyangho, one of a series of brackish lagoons along the eastern coast of Korea. Phytoplankton community structure, physical factors, and chemical factors were surveyed from May 1998 through November 2002 on a two-month interval basis. Temperature, salinity, Secchi disc transparency, TN, TP, organic matter content of sediment, chlorophyll a concentration, dominant phytoplankton species, and phytoplankton cell density were measured. Salinity gradient was formed between the overlying freshwater stream water and the permeated seawater at the bottom. The chemocline was persistent at the depth of 2 ${\sim}$ 5 m that caused discontinuities of salinity, DO, and temperature profiles. The inversion of vertical temperature profiles with higher temperature in deeper layer was observed in early winter. Secchi disc transparency was very low with the range of 0.1 to 1.1m. TP, TN, and Chl. a concentration in the epilimnion was 0.011 ${\sim}$ 0.238 mgP $L^{-l}$, 0.423 ${\sim}$ 2.443 mgN $L^{-l}$, and 0.7 ${\sim}$ 145.2 mg $m^{-3}$, respectively. Sediment was composed of silt and coarse silt. COD, TP, and TN content of dry sediment were 19.7 ${\sim}$ 73.3 mg$O_2\;g^{-1}$, 0.61 ${\sim}$ 1.32 mgP $g^{-l}$ and 0.64 ${\sim}$ 0.88 mgN $g^{-l}$, respectively. Dominant phytoplankton species were chlorophytes (Ankistrodesmus falcatus) and cyanobacteria (Oscillatoria sp. and Merismopedia tennuissima). The total cell density was in the range of 560 ${\sim}$ 35,255 cells $mL^{-l}$.

A Study of Carbonaceous Aerosols Measurement in Metropolitan Area Performed during KORUS-AQ 2016 Campaign (수도권 지역의 탄소 성분 에어로졸 측정 연구: KORUS-AQ 2016 캠페인 기간을 중심으로)

  • Jeong, Byeongju;Bae, Min-Suk;Ahn, Junyeong;Lee, Jeonghoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.205-216
    • /
    • 2017
  • Carbonaceous aerosols such as the equivalent black carbon (eBC), the elemental carbon (EC) and the organic carbon (OC) were monitored at the Seoul Olympic Park site ($37.521^{\circ}N$, $127.124^{\circ}E$) during the KORUS-AQ 2016 campaign using a Multi Angle Absorption Photometer (MAAP) and an OCEC Analyzer. Averaged mass concentrations of eBC, EC and OC were presented as $2.46{\pm}1.52{\mu}g/m^3$, $1.01{\pm}0.60{\mu}g/m^3$ and $4.85{\pm}2.60{\mu}g/m^3$, respectively. OC/EC ratio and mass absorption cross-section (MAC) of light absorbing aerosols were calculated as 2.32 and $14.8m^2/g$, respectively. Diesel OC concentrations were estimated from a source profile of diesel vehicles as well. eBC mass concentrations measured from May $26^{th}$ to May $27^{th}$, 2016 showed 40% higher than averaged eBC mass concentrations during campaign period. $PM_{2.5}$ concentrations measured in this period were also higher than average $PM_{2.5}$ concentrations. High eBC concentrations were observed from May $29^{th}$ to May $31^{st}$, 2016 and from June $9^{th}$ to June $11^{th}$, 2016, possibly due to morning rush hour and the effect of temperature inversion at night. Diurnal variations of eBC, EC and Diesel OC showed a typical pattern of metropolitan area. In the weekend, however, diurnal variations of eBC, EC and Diesel OC mass concentrations were different from those measured in the weekday. It is expected that this study can help to understand the relationship between carbonaceous aerosols in a metropolitan area.

Electrochemical Characteristics of Microporous Polymer Electrolytes Based on Poly(vinylidene-co-hexafluoropropylene) (PVdF계 미세기공 고분자 전해질의 전기화학적 특성)

  • Jung Kang-Kook;Kim Jong-Uk;Ahn Jou-Hyeon;Kim Ki-Won;Ahn Hyo-Jun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.4
    • /
    • pp.183-188
    • /
    • 2004
  • In order to develop polymer electrolyte for lithium/sulfur batteries, highly microporous P(VdF-HFP) membranes were prepared by phase inversion method. Porous structure was controlled by extracting NMP with mixture of deionized water and methanol. Porous structure of the membranes was observed with SEM. Polymer electrolytes were prepared by soaking the porous membranes in 1M $LiCF_3SO_3-TEGDME/EC$. The ionic conductivity of polymer electrolyte was found to be at high as $2\times10^{-3}S/cm$ when the polymer membrane extracted by $80\%$ methanol was used. The microporous polymer electrolyte optimized in this work displayed high ionic conductivity, uniform pore size, low interfacial resistance and stable ionic conductivity with storage time. The ionic conductivity of polymer electrolytes was measured with various lithium salts, and the conductivity showed $3.3\times10^{-3}S/cm$ at room temperature when $LiPF_6$ was used as a lithium salt.

Application of Electrical Resistivity Measurement to an Evaluation of Saline Soil in Cropping Field (염류집적 농경지에서 전기비저항 탐사기법의 활용성)

  • Yoon, Sung-Won;Park, Sam-Gyu;Chun, Hyen-Jung;Han, Keung-Hwa;Kang, Seong-Soo;Kim, Myung-Suk;Kim, Yoo-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1035-1041
    • /
    • 2011
  • Salinity of soil under the plastic film houses in Korea is known as a significant factor to lower the crop production and to hamper the sustainable agricultural land management. In this study we propose a field monitoring technique to examine the methods applied to minimize the adverse effect of salts in soil based on the relationship between soil electrical characteristics and soil properties. Field experiments for 4 different treatments (water only, fertilizer only, DTPA only, and DTPA and fertilizer together) were conducted on soils at the plastic film house built for cultivating a cucumber plant located at Chunan-si, Chungchungnam-do in Korea. The electrical resistivity was measured by both a dipole-dipole and wenner multi-electrodes array method. After the electrical resistivity measurement we also measured the soil water content, temperature, and electrical conductivity on surface soil. The resulted image of the interpreted resistivity by the inversion technique presented a unique spatial distribution depending on the treatment, implying the effect of the different chemical components. It was also highly suspected that resistivity response changed with the nutrients level, suggesting that our proposed technique could be the effective tool for the monitoring soil water as well as nutrient during the cropping period. Especially, subsoils under DTPA treatment at 40 to 60 cm depth typically presented lower soil water accumulation comparing to subsoils under non-DTPA treatment. It is considered that DTPA resulted in increase of a root water uptake. However, our demonstrated results were mainly based on qualitative comparison. Further experiments need to be conducted to monitor temporal changes of electrical resistivity using time lapse analysis, providing that a plant root activity difference based on changes of soil water and nutrients level in time.

Physicochemical Characteristics of Seawater in Gamak Bay for a Period of Hypoxic Water Mass Disappearance (가막만 빈산소 수괴 소멸기의 물리화학적 특성)

  • Kim, Jeong-Bae;Park, Jung-Im;Jung, Choon-Goo;Choi, Woo-Jeung;Lee, Won-Chan;Lee, Yong-Hwa
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.3
    • /
    • pp.241-248
    • /
    • 2010
  • Hypoxic(oxygen-deficient) water masses are a key threat to the ecosystem of shallow marine coastal areas worldwide. The phenomena of hypoxia occurred at Gamak Bay, on the southeast coast of Korea, in late June 2007. In this paper, the physicochemical characteristics of seawater were surveyed for a period of hypoxic water mass disappearance. The hypoxic water mass was located between Sunso and the northwestern area of the inner bay. The dissolved oxygen(DO) concentrations of surface and bottom water were $1.3mgL^{-1}$ and less than $2mgL^{-1}$, respectively, in the hypoxic water masses, and $4.5{\sim}6.8mgL^{-1}$ and $3.8{\sim}6.0mgL^{-1}$ at the other oxygen-rich sample sites, respectively. Chlorophyll a concentrations were $4.9{\sim}25.3{\mu}gL^{-1}$ at the surface, $2.3{\sim}23.1{\mu}gL^{-1}$ in the middle, and $1.9{\sim}9.0{\mu}gL^{-1}$ at the bottom of the hypoxic water masses. When the hypoxic water mass appeared in Gamak Bay, it formed three different vertical types. The first type occurred throughout the water depth around Sunso. The second type developed from the bottom. The third type of hypoxic water mass was formed in the middle water layer when the inversion of water temperature occurred. The third type of phenomena appeared at only St. 9, St. 14 and St. 21 sites near the Hodo coast. Aquatic surface respiration of bottom-dwelling fishes such as the oriental goby(Acanthogobius flavimanus) was observed and many crustaceans were seen along the adjacent shore of the hypoxic water mass area. About 3,000 oriental gobies as well as many crustaceans died due to this event in Gamak Bay. The results of this study could provide fundamental data for the mechanism of hypoxic water masses in Gamak Bay.