• Title/Summary/Keyword: temperature falling

Search Result 216, Processing Time 0.023 seconds

A Study on the Electrodepositic Preparation of Lead Peroxide Anode (電着過酸化鉛陽極製造에 關한 硏究)

  • Nam, Chong-Woo;Kim, Hark-Joon
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.3
    • /
    • pp.229-235
    • /
    • 1970
  • Electrodeposition of lead peroxide on the graphite core was studied. The results are following; 1) At more noble potential than 1.6V vs. S.C.E. and lower temperature than $40^{\circ}C$, $PbO_2$ deposited current efficiency is increased but deposited layer falls off easily from graphite core. 2) Oxygen overvoltage of $PbO_2$ deposited layer on the graphite core is largely with increasing $PbO_2$ depositing anodic potential and with lowlying electrolytic temperature. 3) To obtain the $PbO_2$ deposited layer without falling off from the graphite core, it is necessary to change the electrolytic conditions, anodic potential and electrolytic temperature, in four stages successively.

  • PDF

An Experimental Study on the Prediction of Concrete Compressive Strength by the Maturity Method Using Embedded Wireless Temperature and Humidity Sensor (콘크리트 매립형 무선 온습도 센서 기반 적산온도법을 이용한 콘크리트 압축강도 예측에 관한 실험적 연구)

  • Mun, Dong-Hwan;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.94-95
    • /
    • 2018
  • Prediction of compressive strength of concrete by Maturity Method is applied in construction site. However, due to the use of wired type high-priced equipment, economic efficiency and workability are falling. In this study, a newly developed concrete embedded wireless sensor is used to perform a mock-up test. Next, the concrete compressive strength of the Maturity Method is predicted using Saul and Plowman's function as measured temperature data. The predicted concrete strength at the beginning of the age was the actual strength and stiffness, but the error rate was less than 1% at 28th day.

  • PDF

Filling in Water Temperature Data of Aquatic Environments using a Pre-constructed Relationship

  • Lee, Khil-Ha
    • Journal of Environmental Science International
    • /
    • v.26 no.10
    • /
    • pp.1125-1133
    • /
    • 2017
  • In this study a method for filling in missing data of river water temperature using a pre-constructed mathematical relationship between air and water temperatures is presented. A regression between water temperatures at individual stations and ambient air temperatures at nearby weather stations can provide a practical method for representing missing water temperature data for an entire region. Air and water temperature data that were collected from two test sites (one coastal and, one inland) were individually fitted to a nonlinear regression model. To consider seasonal hysteresis effects, separate functions were fitted to the data in the rising and falling limbs. A single-criterion, multi-parameter optimization technique was used to determine the optimal parameter sets. This method minimizes the differences between the time series of the measured and estimated data. The constructed air-water temperature relationship was subsequently applied to represent missing water temperature data. It was found that the RMSEs(MBEs) were in the range of $1.843-1.976^{\circ}C(-0.329-0.201^{\circ}C)$ and the coefficient of determination were in the range of 0.92-0.96. The results demonstrate that the predicted water temperatures using the regression equations were reasonably accurate.

Heat and mass transfer characteristics in a vertical absorber (수직형 흡수기내 열 및 물질 전달 특성)

  • 서정훈;조금남;최기봉
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.835-845
    • /
    • 1999
  • The objective of the present study was to investigate heat and mass transfer characteristics in a vertical falling film type absorber using LiBr-$H_2O$ solution with 6owt%. The experimental apparatus consisted of an absorber with inner diameter of 17.2 mm and length of 1150mm, a generator, an evaporator/condenser, a solution tank, a sampling trap etc. The parameters were solution temperature of 45 and $50^{\circ}C$, coolant temperature of 30 and $35^{\circ}C$, and film Reynolds numbers from 50 to 150. Pressure drop in the absorber increased as solution and coolant temperatures decreased. Pressure drop in the absorber increased up to the film Reynolds number of 90, and then decreased at the further increase of the Reynolds number above 90. The maximum absorption mass flux observed at the film Reynolds number of 90. Absorption mass flukes increased as coolant temperature decreased. Absorption mass fluxes and heat transfer coefficients under subcooled condition were larger than those under superheated condition. Heat transfer coefficients were affected by solution temperature more than coolant temperature. The maximum absorption effectiveness under the subcooled condition was 23% for coolant temperature of $30^{\circ}C$ and 31% for coolant temperature of $35^{\circ}C$ under the present experimental conditions.

  • PDF

Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (2nd. Report, Characteristics of Heat Transfer) (수직관내(垂直管內)를 흘러내리는 액막식(液膜式) 흡수기(吸收器)의 흡수(吸收) 및 열전달특성(熱傳達特性)(제(第)2보(報) 열전달특성(熱傳達特性)))

  • Ohm, K.C.;Rie, D.H.;Choi, G.G.;Kasiwagi, Takao;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.257-264
    • /
    • 1993
  • This is the second report of a three part study on the absorption and heat transfer characteristics of absorber, the correlation of refrigerating capacity and heating capacity. The 2nd report deals with the heat transfer characteristics of a vertical falling film type absorber of inner copper tube. The solute is LiBr-Water solution(60wt%) and the solvent is water vapor. The film Reynoles numbers are varied in the range of 35~130. The states of LiBr solution at the top of absorber are supercooled liquid and superheated liquid. The results are summarized as follows ; Heat transfer results reveal that for the absorption of falling film, the state of LiBr solution appears to be influential in determining the heat transfer. Thus, for the state of supercooled liquid, heat transfer coefficient decreases with increasing the film Reynolds number, but in the condition of superheated liquid, it increases conversely. The mass transfer coefficients that were presented in the 1st.report and heat transfer coefficients of this paper are presented as the dimensionless correlation. The optimum water flowrate which brings about maximum value of heat flux in the film exists, and that increases with increasing the cooling water temperature.

  • PDF

Impact of Wearing Functional Supporters that Prevent Seniors from Falling on Muscle Function, Sense of Balance, and Overcoming Fatigue (시니어 낙상예방을 위한 기능성 서포터 착용에 따른 근기능 및 균형감각과 피로회복에 미치는 영향 연구)

  • Um, Sungheum;Jang, Seonu;Park, Munhwan;Lee, Seongjae
    • Fashion & Textile Research Journal
    • /
    • v.24 no.1
    • /
    • pp.156-163
    • /
    • 2022
  • Loss of leg muscle and muscle weakness, which are caused by aging, affect muscle function and sense of balance. As a way of preventing seniors from falling, we developed the idea of wearing functional supporters based on graduated compression technique and in the form of a taping supporter. Their impact on power, sense of balance, overcoming fatigue, and subjective wearing sensation was investigated. The following results were obtained. After wearing functional compression supporters, body temperature increased from 24.5 ± 0.5℃ to 26.3 ± 0.6℃. Calf size, which assesses the level of edema, decreased from 26.1 ± 1.8cm to 25.7 ± 1.8cm. The result of dynamic balance test, which helps estimate the fall prevention effect, increased from 6.4 ± 0.9sec to 7.1 ± 0.6sec. Lactate level, which indicates the level of fatigue, decreased from 8.1 ± 0.6mmol/L to 7.3 ± 0.8mmol/L. Standing long jump record, which assesses power, increased from 110.1 ± 3.1cm to 112.0 ± 2.8cm. Standing on one leg with eyes closed, which assesses sense of balance, increased from 4.2 ± 1.1sec to 6.5 ± 0.8sec. Ankle angle, which assesses joint stability, increased from 75.3 ± 4.0° to 80.1 ± 1.7°. In metabolism and physical performance testing, which assesses keep, the score increased from 26.3 ± 1.7 to 28.8 ± 1.2. Muscle supporting score, which assesses joint stability, increased from 7.3 ± 0.6 to 7.8 ± 0.4. In the category of body type, which assesses wearing sensation and body shaping function, the score increased from 5.7 ± 1.4 to 6.4 ± 1.2

Joint Stiffness Evaluation in Jointed Plain Concrete Pavement (줄눈 콘크리트 포장의 줄눈강성 산정 연구)

  • Chon, Beom Jun;Lee, Seung Woo;Kwon, Soon-Min;Kim, Seong-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.49-54
    • /
    • 2009
  • The excellent load transfer at transverse joints ensures the high performance of jointed plane concrete pavements(JPCP). Load transfer efficiency(LTE) is affected by dowel-bars, aggregate interlock and types of underlying layers, and these factors have to be modelled adequately for a reasonable analysis of JPCP. Generally, the joint stiffness has been represented by a spring model for the shear transfer by aggregate interlock or dowels. However dowel-bars, aggregate interlock and types of underlying layers have not been considered together in the design of joints. In this study, the joint stiffness that considered those factors was presented by comparing LTE obtained using FWD(Falling Weight Deflectometer) with theoretical results obtained using the finite element analysis. In addition, the effects of temperature and concrete age, on the joint stiffness were investigated.

A Study on the Thermal Characteristics of the Large Low Temperature Vacuum Dryer for Biological Drying (생체 건조용 대형 저온진공건조기의 열적 특성에 관한 연구)

  • 김경근;성부용;정한식;최순열;문수범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.427-434
    • /
    • 2000
  • In tradition, there have been two kinds of drying methods, which are sun drying and artificial drying. The sun drying method which has been adopted traditionally has been replaced by the hot-air drying method which is one of the most general methods of artificial drying, with its simple drying system, low initial cost of drying plant, and easy operating method. But the hot-air drying method has some defects; (1) much energy loss happens due to the discharge of hot air during the drying process, (2) control of drying rate is not easy on account of changing relative humidity of inlet air for uniform hot air temperature, (3) high temperature of foods in drying process brings about the production of low-grade drying products. Vacuum drying takes advantage of energy saving and mass production because it reduces the drying time by increasing the drying rate under low temperature condition. The aim of this paper is to develop the low temperature vacum dryer, with low initial investments and operating costs, easy operating method and trouble-free operation.

  • PDF

Effects of Maesil Extract on the Quality Characteristics of Yellow Layer Cake(I) - Rheology Characteristics of Cake Batter - (매실 엑기스 첨가가 Yellow Layer Cake의 품질 특성에 미치는 영향(I) - 케이크 반죽의 리올로지 특성 -)

  • Choi, Bong-Soon;Nam, Yoon-Joo;Hwang, Seong-Yun;Kang, Kun-Og
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.4
    • /
    • pp.539-546
    • /
    • 2008
  • This study was conducted in order to investigate the effects of maesil extract on medium and cake flour using the falling number and RVA tests, as well as farinography, and alveography. The maesil extract were added on the medium and cake flour bases, 3% and 5% each. The falling numbers of the medium and cake flour with maesil extract were increased due to alteration of the protein in the flour. Analysis of the RVA characteristics showed that the addition of maesil extract did not have a significant effect on the initial pasting temperature. Peak viscosity, holding strength, final viscosity, and the breakdown and setback values of the medium flour were not consistent, but those of the cake flour decreased. Farinography demonstrated that the addition of maesil extract decreased water absorption and improved the stability of the medium and cake flour. The characteristics of the alveogram showed that the addition of maesil extract increased the extensibility and swelling index. Based on the experimental data, the processing rheology may be good when using maesil extract to make yellow layer cake.

  • PDF

Microbiological Hazard Analysis of Non-Heating Process Menus Served at Foodservice Operations and Hygienic Improvements by Implementing HACCP (급식소에서 제공되는 비가열조리 음식의 위해요인 분석과 HACCP 적용 후 위생개선효과)

  • Lee, Mi-Ra;Kim, Heh-Young
    • Korean journal of food and cookery science
    • /
    • v.23 no.5
    • /
    • pp.749-760
    • /
    • 2007
  • The purpose of this study was to evaluate the microbiological quality of non-heat-processed foods and the effects of HACCP implementation. Here, cabbage salad and cucumber&onion salad were selected and we investigated HA(Hazard Analysis) by checking microbiological quality, time and temperature, pH, and water activity at each processing stage. Thus, the receiving of spices and dressings, washing and sterilizing, cutting, cooking, and serving stages were all considered CCPs. Before implementing HACCP, microbial analysis showed that standard plate counts and coliform counts were higher than standard levels in most of the raw ingredients of each menu, as well as during the production process. The microbiological quality of the utensils and employee's hands used during cooking indicated levels requiring direct management. Evaluations of falling bacteria-in the foodservice establishment work areas ranged from $2{\sim}12CFU/plate$. However, after HACCP implementation, microbiological levels improved to standard levels fly sanitation education. Also, the number of falling bacteria were lower than before implementing HACCP. Therefore, it is essential the foodservice operations make efforts to implement HACCP, so that microbiological hazard levels are lowered and hygienic status improved.