온도측정 기반의 최적전압을 이용한 PV 시스템의 TMOV MPPT 제어 (TMOV MPPT Control of PV System with Temperature Measurement based Optimal Voltage)

  • 고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.30-39
    • /
    • 2012
  • The characteristics of I-V and P-V of solar cell nonlinearly changes according to irradiation, temperature and load. Therefore, to use efficiently PV system, operating point must be always operating at maximum power point. Also, PV system is semiconductor, so it generates loss by temperature. But because of conventional MPPT methods are not considering temperature, it has problem which decrease efficiency. This paper proposes temperature measurement based optimal voltage(TMOV) MPPT algorithm using temperature measurement based optimal voltage. It analyzes characteristics of solar cell according to irradiation and temperature and conventional MPPT methods. The TMOV control algorithm proposed in this paper is compared and analyzed conventional MPPT methods. The validity of this paper proves using this result.

외기온도와 환수온도를 이용한 보일러의 공급수온도설정 (Boiler Supply Water Temperature Setting by Outside Air Temperature and Return Water Temperature)

  • 한도영;유병강
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2009
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a boiler unit, the effective operation is necessary. In this study, the supply water temperature algorithm of a condensing gas boiler was developed. This includes the setpoint algorithm and the control algorithm of the supply water temperature. The setpoint algorithm was developed by the fuzzy logic and the control algorithm was developed by the proportional integral algorithm. In order to analyse the performance of the supply water temperature algorithm, the dynamic model of a condensing gas boiler system was used. Simulation results showed that the supply water temperature algorithm developed for this study may be practically applied for the control of the condensing gas boiler.

  • PDF

유전알고리즘을 이용한 열전소지 기반 히팅 시스템의 최적 온도 제어기 구현 (Implementation of Optimal Temperature Controller for Thermoelectric Device-based Heating System Using Genetic Algorithm)

  • 공정식
    • Design & Manufacturing
    • /
    • 제17권3호
    • /
    • pp.41-47
    • /
    • 2023
  • This paper presents the development of a controller that can control the temperature of an heating system based on a thermoelectric module. Temperature controller using Peltier has various external factors such as external temperature, characteristics of an aluminum plate, installation location of temperature sensors, and combination method between the aluminum plate and heating element. Therefore, it is difficult to apply the simulation and simulation results of heating system using Peltier at control algorithm. In general, almost temperature controller is using PID algorithm that finds control gain value heuristically. In this paper, it is proposed mathematical model that explain correlate between the temperature of the heating system and input voltage. And then, optimal parameter of estimated thermal model of the aluminum plate are searched by using genetic algorithm. In addition, based on this estimated model, the optimal PID control gain are inferred using a genetic algorithm. All of the sequence are simulated and verified with proposed real system.

Implementation of Fuzzy Logic Control for Air Conditioning Systems

  • Mongkolwongrojn, M.;Sarawit, V.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1264-1267
    • /
    • 2005
  • Fuzzy logic control has been widely applied for handling the system which has uncertainty or high robust system. Since the dynamic behaviors of the systems contain complexity and uncertainty in its parameters, several fuzzy logic controllers have been implemented to control room temperature in the field of air conditioning system. In this paper, the fuzzy logic control has been developed to control both in door temperature and humidity in the air conditioning systems. The manipulating variables are speed of compressor, heater and supply air flow rate. The microcomputer was used to interface with in system. The experimental results show the superior of multivaiable fuzzy logic control to keep room temperature and humidity in air conditioning system for the best comfortable.

  • PDF

컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구 (An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer)

  • 조진호;이대우
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

자기센서를 이용한 위치검출 실린더의 온도변화에 따른 성능평가 (Evluation of Sensing Performance of Stroke Sensing Cylinder under Various Temperature Conditions)

  • 김성현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.215-219
    • /
    • 1996
  • We developed a part of hydraulic stroke sensing cylinder for te purpose of position controlbyusing magnetic sensor and evaluated variously its performance its performance. In this paper, for the evaluation of the developed cylinder under various temperature change, thermal control systems are designed and controlled. It is composed of an heater case, temperature sensor, and interface circuits which included SCR(silicon controlled rectifier) for the control of the voltage's phase. To obtain various temperature conditions, the thermal systems are controlled by using Ziegler-Nichols PED tuning method. The thermalcontrol systems are used to experiment to evaluate whether the developed cylinder can obtain a stable output signal for detecting a stroke of the cylinder under the controlled temperature condition.

  • PDF

배기 가스 유량 제어를 이용한 버너방식 디젤 입자상물질 제거 장치의 재생 (Regeneration of Burner Type Diesel Particulate Trap System Through Active Exhaust Gas Feeding)

  • 김재업;박동선;이만복;김응서
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-13
    • /
    • 1997
  • The key point that guarantees the durability of the ceramic monolith filter is to lower peak temperature and temperature gradient inside filter during regeneration. The control of the exhaust gas flow rate into the filter, by the bypass technique of the exhaust gas, enables the gas temperature in filter to be constant for regeneration. A couple of methods, which are the ON/OFF and PID control of the bypass valve, were used for feedback control of the gas temperature. These techniques showed that the ceramic filter was regenerated perfectly under the peak temperature and peak temperature gradient limitations for durability.

  • PDF

열처리용 단상 PWM인버터시스템의 히터온도 및 인버터 출력전압 제어기법 (Control Strategies of Both the Heater Temperature and the Inverter Output Voltage of a Single-Phase PWM Inverter Systems for Heat Treatment)

  • 양시경;전태원
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1047-1054
    • /
    • 2018
  • This paper proposed the strategies for controlling both the heater temperature and the output voltage of a single-phase inverter for the heat treatment. The single-phase inverter system for the heat treatment controls the heater temperature to its reference one, and also it limits the inverter output voltage to 60 V for safety. The stability may be deteriorated due to the large time constant difference between the heater temperature and inverter output voltage. In order to ensure the stability, a hysteresis on/off control approach for the heater temperature control is adapted, and both the open-loop and the closed-loop control strategies of the output voltage are suggested. The performances for the proposed strategies are demonstrated with the experiments.

사출 금형의 능동형 온도제어에 따른 사출특성에 관한 연구 (A Study on Injection Characteristic using Active Temperature Control of Injection mold)

  • 조창연;신홍규;홍남표;서영호;김병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.302-305
    • /
    • 2007
  • In recent years, many researches on new storage media with high capacity and information are developing. For manufacture of optical storage with high capacity, the injection molding process is generally used. In order to increase the filling ratio of the injection molding structure, the injection molding process required for high injection pressure, packing pressure and temperature control of the mold. However, conventional injection molding process is difficult to increase the filling ratio using injection master with the range of several nanometers and high aspect ratio. In order to improve and increase filling ratio of nano-structure with high aspect ratio, the active temperature control of injection mold was used. Experimental conditions were used injection pressure, time and temperature. Consequently, by using the peltier device into injection mold, we carried out the efficient and active temperature control of mold at low cost.

  • PDF

퍼지로직 과열도 재설정 알고리즘을 사용한 멀티형 냉방시스템의 전자팽창밸브 제어 (The EEV Control of the Multi-type Air-conditioning System by using a Fuzzy Logic Superheat Temperature Setpoint Reset Algorithm)

  • 한도영;이상원
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.382-388
    • /
    • 2003
  • Refrigerant flow rates of the multi-type air-conditioning system can be regulated by electronic expansion valves (EEV). The performance of the multi-type air-conditioning system may be improved by lowering the superheat at the compressor suction side. In this study, a superheat temperature setpoint reset algorithm was developed by using fuzzy logics, and a PI algorithm was applied to control the superheat temperature near setpoints. Experimental results showed energy savings and stable operations at a multi-type air-conditioning system. Therefore, the developed setpoint reset algorithm may be effectively used for the EEV superheat temperature control of the multi-type air-conditioning system.