• 제목/요약/키워드: temperature calibration

검색결과 516건 처리시간 0.026초

Calibration of Stellar Isochrones for G- and K-type Dwarfs based on High-Resolution Spectra

  • Lim, Yeseul;An, Deokkeun
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.56.3-57
    • /
    • 2016
  • We present a recent progress on calibration of stellar isochrones based on a set of high-resolution spectra for 170 G- and K-type dwarfs in the solar neighborhood. We compare observed magnitudes of these stars in a number of broad passbands [UB(B_T)V(V_T)RIJHK] with model magnitudes generated using ATLAS9 synthetic library at the previously derived set of spectroscopic parameters. We find systematic offsets in colors from these passbands, which are mainly revealed as a function of effective temperature of stars. In order to remove these systematic color mismatches, we derive correction functions and apply them to the model spectra.

  • PDF

공기 중 휘발성 유기화합물의 측정을 위한 열탈착-분석시스템의 구성 및 평가 (Composition and Evaluation of the Thermal Desorption-Gas Chromatographic System for the Measurement of Volatile Organic Compounds in Air)

  • 이수형;송희남;김희갑
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권1호
    • /
    • pp.63-71
    • /
    • 2002
  • The thermal desorption-gas chromatographic (TD-GC) system has been constructed for the measurement of volatile organic compounds. The thermal desortion unit is composed of four major parts: 1) the control part; 2) the thermal desorption part; 3) the focusing part; and 4) the injection part. The peltier element was introduced to the focusing part for the temperature of the focusing tube to reach-35$^{\circ}C$. The system was tested for the linearity of the calibration curves and reproducibility of instrumental analyses using some disinfection by-products (DBPs) and BTXs (benzene, toluene and p-xylene). The coefficients of determination (r$^2$) for all the calibration curves made were higher than 0.998, and the coefficients of variation (CV) for triplicate measurements were all within 10%. The system also has been tested for field applicability. The analysis of field samples showed that there was no breakthrough problem in the sampling system and that the system could be applied to field measurements.

공작기계의 오차요소 측정을 통한 3차원 위치정밀도 향상 (The enhancement of 3-dimensional positioning accuracy by measuring error factors for CNC machine tools)

  • 손진욱;서석환;정세용;이응석;위현곤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.260-265
    • /
    • 1994
  • Efforts have been devoted to developing rapid and accurate methods for measuring the errors of machine tools. The method os measurement and calibration of machine tool errors should be general and efficient. The objective of this study is to show in detail the full sequence from the measurement of errors factors to the verification of the positioning accuracy after compensation for the volumetric error. In this paper, we described the steps in measuring the volumetric error parameters, a general error model composed of error parameters, temperature, and the desired position. The validity of the error calibration methods proposed in this paper was tested using a vertical 3-axis CNC machine with a laser interferometer and a ball bar.

  • PDF

The Off-Axis Properties of Solar X-Ray Telescopes: I. Evaluation of the Vignetting Effect

  • 신준호
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.35.1-35.1
    • /
    • 2011
  • The solar X-ray telescopes, the Yohkoh SXT and the Hinode XRT, have observed for a couple of decades a variety of coronal structures in the range of wide field-of-view (FOV) covering the full solar disk. It has been emphasized that the optical structure of solar telescopes should be designed with care for improving the uniformity over the full FOV. The vignetting effect is one of the important optical characteristics for describing the performance of a telescope, which reflects the ability of collecting the incoming light at different locations and different photon energies. The correction of this vignetting effect would be an important calibration step that should be performed in advance, especially when the observed images are to be used for photometric purposes. Since the vignetting effect of solar X-ray telescopes shows wavelength dependence, a special care should be taken when, for example, performing the temperature analyses with thin and thick filters for flaring activities observed at the periphery of the full FOV. The results of analysis of pre-launch calibration data for the evaluation of vignetting effect will be introduced in detail.

  • PDF

So, You Need Reliable Magnetic Measurements You Can Use With Confidence? How the Magnetic Measurement Capabilities at NPL Can Help

  • Hall, Michael;Harmon, Stuart;Thomas, Owen
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.339-341
    • /
    • 2013
  • The magnetic field standards, facilities and capabilities available at NPL for the calibration of magnetometers and gradiometers and the measurement of the magnetic properties of materials will be introduced. The details of the low magnetic field facility will be explained and the capabilities this facility enables for the characterisation and calibration of ultra-sensitive room temperature magnetic sensors will be presented. Building on core material capabilities that are compliant with the IEC 60404 series of written standards, the example of a standard permeameter that has been modified for the measurement of strips for real world conditions is discussed. This was incorporated into a stress machine to measure the DC properties of the soft magnetic materials used by the partners of a collaborative industry led R&D project at stress levels of up to 700 MPa. The results for three materials are presented and the changes in the properties with applied stress compared to establish which material exhibits favourable properties.

현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정 (Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design)

  • 조명환;김낙석;심재필
    • 대한토목학회논문집
    • /
    • 제31권3D호
    • /
    • pp.433-439
    • /
    • 2011
  • 도로의 동상방지층을 설치하기 위하여 동결심도(동결관입깊이)를 산정하는데, 동결지수는 $0^{\circ}C$ 이하의 기온과 영하온도의 지속시간을 곱한 값을 연간을 통하여 누계한 수치로 표시된다. 따라서, 일평균 대기 온도를 구하는 방법이 동결지수에 영향을 미칠 수 있다. 기상청의 경우 1999년을 기점으로 이전에는 1일 4회 평균 대기온도 제공하였으며, 현재는 1일 8회 평균 대기온도를 제공하고 있다. 본 연구에서는 이러한 일평균 대기온도를 산정하는 방법이 동결지수의 산정결과에 미치는 영향을 확인하기 위하여 한반도 남부(동결지수 $350^{\circ}C{\cdot}$일 미만) 6개 지역을 현장조건(저성토부, 절성경계부 및 절토부)에 따라 구분하여 15개소에 대하여 현장계측시스템을 구축하였다. 그리고 현장계측시스템으로부터 얻어진 대기온도를 통하여 동결지수를 산정하고 상호 비교분석 하였다. 비교분석 결과 일반적으로 1일 4회 평균 대기온도를 사용한 경우가 1일 8회 평균 대기온도를 사용하는 경우보다 약 3% 전후 큰 것으로 나타났으며, 본 연구 지역에 대한 동결지수를 결정할 때 동결지수를 보정할 수 있는 보정식을 제안하였다.

적외선 검출기 검보정을 위한 대구경흑체 설계, 제작 및 검증 (Full Aperture Black Body Design, Fabrication and Validation for Infrared Detector Calibration)

  • 조혁진;서희준;김근식;박성욱;문귀원
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.40-45
    • /
    • 2013
  • 적외선 영상을 획득하는 인공위성의 적외선 검출기는 임무 궤도에서 정확한 성능을 보장받기 위해 발사 전 지상에서 흑체를 이용한 검보정 환경시험을 거쳐야 한다. 적외선 탑 재체의 검보정 기준이 되는 대구경흑체는 궤도환경 지상시험을 위해 진공환경에 적합한 재질로 구성되어야 하며, $-40^{\circ}C$에서 $+40^{\circ}C$까지의 온도 범위에서 중심 80 %의 영역에 대해 $2^{\circ}C$ 이하의 표면 온도 균일도와 0.95 이상의 방사율을 가져야 한다. 열유동해석 결과로 도출된 대구경흑체는 $1m{\times}1m{\times}8mm$의 크기의 구리판에 방사율을 높이기 위한 알루미늄 하니콤 코아를 부착하고, 블랙페인트를 도포하여 제작되었으며, 온도 조절을 위해 뒷면에는 질소가스 흐름을 위한 구리튜브가 용접되었다. 한국항공우주연구원의 광학열 진공챔버에서 수행된 대구경흑체 검증시험에서 20개의 저항온도센서와 적외선카메라를 이용하여 표면 온도 분포를 측정하여 ${\pm}40^{\circ}C$의 온도 범위에서 약 $1^{\circ}C$의 온도 균일도를 가짐을 확인하였다. 표면방사율은 대기압, $40^{\circ}C$에서 0.975로 측정되었다.

LTPP 구간에서 TDR 방식 함수량계를 이용한 현장함수비 보정모델 개발과 함수비 분석 연구 (Development of Calibration Model and Analysis of Soil Water Content using Time-Domain Refelctometry Probe in LTPP Sections)

  • 김부일;전성일
    • 한국도로학회논문집
    • /
    • 제7권4호
    • /
    • pp.103-112
    • /
    • 2005
  • 도로포장구조체에서 하부구조의 함수비는 포장공용성에 중요한 영향을 미칠 수 있다. 최근 들어 많은 연구자들이 현장 계측을 통한 포장하부구조의 함수비를 주기적으로 측정하기 위해서 TDR(Time-Domain Reflectometry) 함수량계를 사용하고 있다. 일반적으로 TDR 함수량계는 흙의 타입, 입도, 밀도, 온도 등에 의해 오차가 유발된 수 있기 때문에, 현장의 흙을 사용하여 TDR 함수량계의 실내보정실험을 반드시 수행해야 한다. 본 연구에서는 LTPP(Long Term Pavement Performance) 구간의 노상재료와 보조기층재료에 대하여 TDR 함수량계(CS616) 실내보정실험을 수행하였으며, 이 결과로부터 TDR 함수량계의 보정모델을 개발하였다. 또한 현장데이터의 분석을 통해, 함수량계가 동결의 발생여부, 부동수의 양, matric suction 등을 판단하는데 활용될 수 있음을 확인하였다.

  • PDF

순복사계의 야외 상호 비교 및 보정 (Field Intercomparison and Calibration of Net Radiometers)

  • Byung-Kwan Moon;Sang-Boom Ryoo;Yong-Hoon Youn;Jonghwan Lim;Joon Kim
    • 한국농림기상학회지
    • /
    • 제5권2호
    • /
    • pp.128-137
    • /
    • 2003
  • 순복사는 지표 에너지 수지의 가장 근본적인 요소 중 하나이다. 순복사의 정확한 관측을 위해, 주기적이고 지속적인 순복사계 보정이 요구된다. 플럭스 관측에 널리 사용되는, 두 가지 타입의 대표적인 순복사계 (Q-7.1과 CNR1)의 상호 비교 및 보정 실험이 약 4개월 간격으로 두 차례 시행되었다. Q-7.1과 CNR1 간의 차이는 7.7% 이내였고, 표준 기기와의 보정 후 오차는 3.2%이내였다. 순복사계의 반응 차이와 보정 계수는 대기 상태, 특히 계절 변화에 따른 온도 차이에 따라 다르게 나타났다. 결론적으로, 주기적으로 보정된 Q-7.1은 CNR1을 대체하여 장기 관측에 사용될 수 있고, 보정 주기로는 4-6개월이 권장된다.

A 4-Channel Multi-Rate VCSEL Driver with Automatic Power, Magnitude Calibration using High-Speed Time-Interleaved Flash-SAR ADC in 0.13 ㎛ CMOS

  • Cho, Sunghun;Lee, DongSoo;Lee, Juri;Park, Hyung-Gu;Pu, YoungGun;Yoo, Sang-Sun;Hwang, Keum Cheol;Yang, Youngoo;Park, Cheon-Seok;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.274-286
    • /
    • 2016
  • This paper presents a 4-channel multi-rate vertical-cavity surface-emitting laser (VCSEL) driver. In order to keep the output power constant with respect to the process, voltage, temperature (PVT) variations, this research proposes automatic power and magnitude. For the fast settling time, the high-speed 10-bit time-interleaved Flash-successive approximation analog to digital converter (Flash-SAR ADC) is proposed and shared for automatic power and magnitude calibration to reduce the die area and power consumption. This chip is fabricated using $0.13-{\mu}m$ CMOS technology and the die area is $4.2mm^2$. The power consumption is 117.84 mW per channel from a 3.3 V supply voltage at 10 Gbps. The measured resolution of bias /modulation current for APC/AMC is 0.015 mA.